9100 UV-Vis Spectrophotometer

Palintest 9100 UV-Vis Spectrophotometer

UV-Vis spectroscopy from Palintest Ltd utilises the full range of


formulated applications for drinking water, wastewater and industrial
process applications

The Palintest 9100 UV-Vis Spectrophotometer provides the full power of spectroscopic analysis with
the convenience of the Palintest range of prepared tablet and liquid reagents. Designed to operate in
stand-alone mode or controlled via dedicated software, the Palintest 9100 UV-Vis Spectrophotometer
delivers superior technical performance within a compact footprint.

Supplied complete with all required accessories, the spectrophotometer is operating and reporting
accurate and reliable data within minutes. The Palintest reagent calibration data is automatically loaded
either via the software or the program card/PCMA slot.

Every Palintest 9100 UV-Vis Spectrophotometer is delivered with a full validation ensuring compliance
with local standards for GLP. Technical support and training are available either directly from Palintest
Ltd or our international network of dedicated distributors.
Palintest Spectrophotometer Software

The Palintest 9100 UV-Vis Spectrophotometer


features RS 232 communication to a local pc
running the dedicated Palintest Spectrophotometer
Software suite.
Offering full remote control of all spectrophotom-
eter functionality, the software includes data
manipulation and reporting tools. Setting of
parameters for operation of photometric, quanti-
tation, kinetic and spectral modes is simple and
intuitive.

Data manipulation such as arithmetic processing,


peak picking, spectral overlay and three dimension-
al graphical representations allow enhanced report-
ing, either directly from the Palintest Spectropho-
tometer Software or via a seamless link to other
packages such as Microsoft Word/Excel.

Administration of users including access rights,


editing options and a comprehensive log of all
actions ensure that the software produced meets
the validation requirements of the most demanding
audit trail.

Accessories and Reagents


The Palintest 9100 UV-Vis Spectrophotometer is supplied with all accessories required to generate data
in minutes. Included in the package are the Motorized 8 Cell Holder, the Fixed Cell Holder, Palintest
Spectrophotometer Software disk, Quantitation PCMA Card and additional sundry items such as
cuvettes, cells and stopwatch.
The extensive range of Palintest reagents produce high quality results across a wide range of applica-
tion areas such as drinking water, process water, wastewater and environmental applications.
Reagents

RANGE REAGENT REAGENT


REFILL REFILL
TEST (mg/l) PACKS PACKS
(50 TESTS) (250 TESTS)

Alkalinity Total (AlkaphotTM) 0 - 500 CaCO3 PM 188 AP 188

Alkalinity M (AlkaphotTM M) 0 - 500 CaCO3 PM 250 AP 250

Alkalinity P (AlkaphotTM P) 0 - 500 CaCO3 PM 251 AP 251

Aluminium 0.02 - 0.5 PM 166 AP 166


Ammonia 0.01 - 1.0 (N) PM 152 AP 152
Bromine 0.04 - 10.0 PM 060 AP 060
Calcium Hardness (CalcicolTM) 5 - 500 CaCO3 PM 252 AP 252

Chloride (Chloridol) 0.4 - 50,000 (NaCl) PM 268 AP 268


Chlorine DPD No 1 0.01 - 5.0 PM 011 AP 011
Chlorine DPD No 2 0.01 - 5.0 PM 021 AP 021
Chlorine DPD No 1 and 3 0.01 - 5.0 PM 031 AP 031
Chlorine DPD 4 0.01 - 5.0 PM 041 AP 041
Chlorine HR (High Range) 1 - 250 PM 162 AP 162
Chlorine Dioxide (DPD) 0.02 - 10 PM 052 AP 052
Chlorine Dioxide LR (Low Range) 0.03 - 2.5 PM 064 AP 064
Chlorine Dioxide HR (High Range) 0.45 - 20 PM 065 AP 065
Chromium (VI) (Chromicol) 0.02 - 1.0 PM 281 AP 281
Copper (Coppercol) (Free, Combined and Total) 0.03 - 5.0 PM 186 AP 186
Copper (Free) 0.03 - 5.0 - AP 187
Colour/Turbidity 10 - 500 (Hazen units) PM 269 -
Cyanuric Acid 2 - 200 PM 087 AP 087
Dissolved Oxygen (0.8/vials) 0.02 - 0.8 PL 553† -
Dissolved Oxygen (2.0/vials) 0.05 - 2.0 PL 503† -
Dissolved Oxygen (20/vials) 0 - 20 PL 513† -
Fluoride 0.1 - 1.5 PM 179 AP 179*
Hardness (HardicolTM) 5 - 500 (CaCO3) PM 254 AP 254
Hydrazine 0.01 - 0.5 PM 103† AP 103•
Hydrogen Peroxide LR 0.02 - 2.0 PM 104 AP 104
Hydrogen Peroxide HR 1 - 100 PM 105 AP 105
Iron LR 0.01 -1.0 - AP 155
Iron MR 0.02 - 5.0 PM 292 AP 292
Iron HR 0.05 - 10 PM 156 AP 156
Magnesium (Magnecol ) TM
2 - 100 PM 193 AP 193
Manganese 0.001 - 0.03 PM 173 AP 173
Manganese HR 0.01 - 5.0 PM 174 AP 174
Molybdate LR 0.2 - 20 PM 258 AP 258*
Molybdate HR 0.5 - 100 PM 175 AP 175
Nickel (Nickeltest) 0.12 - 10 PM 284 AP 284*
Nitrate (Nitratest) 0.2 - 20 N PM 163 AP 163*
Nitrite (NitricolTM) 0.01 - 0.5 PM 109 AP 109
Nitrite (Nitriphot) 10 - 1500 (NaNO2) PM 260 AP 260

Organophosphonate (OP) 0.2 - 20 (PO4) PM 262 AP 262

Ozone 0.01 - 2.0 PM 056 AP 056


pH (Phenol Red) 6.8 - 8.4 PM 130 AP 130
Phenol (Phenoltest) 0.07 - 5.0 PM 287 AP 287*
PHMB 2 - 100 PM 272 AP 272
Phosphate LR 0.03 - 4.0 PM 177 AP 177*
Phosphate HR 1 - 100 PM 114 AP 114
Potassium 0.5 - 12 PM 189 AP 189
Silica LR 0.02 - 4.0 PM 181 AP 181*
Silica HR 0.5 - 150 PM 290 AP 290*
Sulphate 5 - 200 PM 154 AP 154
Sulphide 0.01 - 0.5 PM 168 AP 168*
Sulphite (Sulphitest) 5 - 500 (Na2SO3) PM 266 AP 266

Zinc 0.02 - 4.0 PM 148 AP 148


TubetestsTM - COD, Nutrients and Metals

Ammonia Nitrate and Phosphate TubetestsTM


CODE DESCRIPTION RANGE (mg/l) NUMBER OF
TESTS
PL 400 Ammonia/12N/50N (Indophenol Method) 0.15 - 12 and 0.7 - 50 mg/l (N) 25
PL 420 Ammonia/15N (Nessler Method) 0.06 - 15 mg/l (N) 25
PL 424 Ammonia/50N (Nessler Method) 0.5 - 50 mg/l (N) 25
PL 425 Ammonia/100N (Nessler Method) 1 - 100 mg/l (N) 25
PL 404 Nitrate/30N 0.3 - 30 mg/l N (or 0 - 150 mg/l NO3) 25
PL 408 Total Nitrogen/30N* 0.6 - 30 mg/l N 25
PL 412 Phosphate/12P 0.1 - 12 mg/l P (or 0.3 - 36 mg/l PO4) 25
PL 416 Total Phosphorus/12P 0.1 - 12 mg/l P 25
*for use with PL 404

Metals Tubetests TM

CODE DESCRIPTION RANGE (mg/l) NUMBER OF TESTS


PL 427 Copper 0.2 - 20 mg/l Cu 25
PL 430 Nickel 0.3 - 20 mg/l Ni 25
PL 434 Iron 0.3 - 25 mg/l Fe 25
PL 442 Zinc 0.1 - 7/0.5 - 35 mg/l Zn 25
PL 436 Total Chromium 0.2 - 10 mg/l Cr 25
PL 440 Hexavalent Chromium (VI) 0.1 - 10 mg/l Cr 25

Chemical Oxygen Demand


CODE DESCRIPTION (25 tests per carton) RANGE (mg/l) NUMBER OF TESTS

PL 450 COD/150 TubetestsTM/Mercury Free 5 - 150 25


PL 460 COD/150/M Tubetests TM
with Mercury 5 - 150 25
PL 461 COD/150/2M Tubetests TM
High Chloride 5 - 150 25
PL 481 COD/150 M/C TubetestsTM with Mercury 5 - 150 25
PL 452 COD/400 Tubetests /Mercury Free
TM
20 - 400 25
PL 462 COD/400/M Tubetests TM
with Mercury 20 - 400 25
PL 453 COD/1000 Tubetests /Mercury Free
TM
10 - 1,000 25
PL 463 COD/1000/M Tubetests /Mercury Free
TM
10 - 1,000 25
PL 468 COD/1000/2M TubetestsTM/Mercury Free 10 - 1,000 25
PL 484 COD/1,500 M/C Tubetests TM
with Mercury 50 - 1,500 25
PL 454 COD/2,000 Tubetests /Mercury Free
TM
50 - 2,000 25
PL 464 COD/2,000/M Tubetests TM
with Mercury 50 - 2,000 25
PL 465 COD/2,000/2M TubetestsTM High Chloride 50 - 2,000 25
PL 486 COD/15,000 M/C TubetestsTM with Mercury 500 - 15,000 25
PL 456 COD/20,000 Tubetests /Mercury Free
TM
500 - 20,000 25
PL 466 COD/20,000/M Tubetests TM
with Mercury 500 - 20,000 25
PL 467 COD/20,000 Tubetests TM
High Chloride 500 - 20,000 25
Technical Specifications
Photometric System Split beam

Wavelength Range 190 – 1100nm

Wavelength Accuracy ±1.0nm

Wavelength Reproducibility <


_ 0.2nm
Spectral Bandwidth 2 nm

Photometric Range -0.3 – 3.0 Abs; 0 – 200%T

Photometric Accuracy ±0.3%T


Photometric Reproducibility <
_ 0.15%T
Stray Light _ 0.05%T
<
Baseline Flatness ±0.002Abs
Noise 0%T: ±0.005%T
100%T: <
_ 0.15%T
Baseline Stability <0.001Abs/hr
Light Source Tungsten lamp, Deuterium lamp
Detector Silicon photodiode
Interface Options PC via RS232 interface
Multi function instrument keypad
PCMA program card

Dimensions 476 x 362 x 225mm


Weight 11kg
Voltage 230V AC

Ordering Information
PT 9100 Palintest 9100 UV-Vis Spectrophotometer Set
Palintest 9100 UV-Vis Spectrophotometer
Motorized 8-cell changer
Fixed cell holder
PCMA program card
RS 232 cable
Palintest Spectrophotometer Software (requires activation code)
Two square cells
Five round cells
Crushing rods
Lint free cloths
Stopwatch
Manuals and validation certificates
Palintest Ltd
Palintest House, Kingsway, Team Valley, Distributed by:
Gateshead, Tyne & Wear, NE11 0NS,
England
Tel: +44 (0) 191 491 0808
Fax: +44 (0) 191 482 5372
E-mail: [email protected] (Mainland UK)
[email protected] (International)

Palintest Australia and Asia Pacific


1/53 Lorraine Street,
Peakhurst Business Centre,
Peakhurst, NSW 2210,
Australia
Tel: +61 1300 131516
Fax: +61 1300 131986
E-mail: [email protected]
All the information within this brochure was correct at
the time of printing. Palintest reserve the right to make
changes to their products to improve their performance or
appearance.
Palintest USA
21 Kenton Lands Road,
Erlanger, Kentucky 41018,
USA Palintest Middle East
Tel: + 1 859 341 7423 P.O. Box 27709, Engomi 2432,
Toll Free: 800 835 9629 Nicosia, Cyprus
Fax: +1 859 341 2106 Tel: +357 22666080
E-mail: [email protected] Fax: +357 22660355
E-mail: [email protected]

Palintest China
Room 1601, Kun Tai International Mansion,
12B Chao Yang District,
Beijing, 100020,
PRC
Tel: +86 10 5126 1868
Fax: +86 10 58790155
E-mail: [email protected]

www.palintest.com
www.palintestusa.com
www.palintest.com.au
www.palintest.cn
www.palintest.fr
www.palintest.es
www.palintest.de
www.palintest.it

Visit your local site for more information on Palintest products