Senturion XPR04 Proximity Probe: Condition Monitoring Solutions
Senturion XPR04 Proximity Probe: Condition Monitoring Solutions
TECHNICAL
INFORMATION
CONDITION
MONITORING
SOLUTIONS
The XPR04 proximity probe system is made up of a calibrated probe, extension cable
and driver. Utilising the eddy current principle, this combination forms a tuned circuit
with the target material and variations in probe face to target distance are detected in
this circuit by the driver. This provides a linearised voltage output proportional to
target gap with a nominal sensitivity of 7.87 mV/um and a range of up to 2.5 mm. This
type of measurement system provides highly accurate (resolution typically less than
one micro-meter) vibration and relative positional measurements, for harsh
environments up to 180 °C.
The driver unit offers selectable system lengths of 5 m, 7 m or 9 m, with a front panel
green LED indicating the selected option. The gap voltage monitoring socket assists
with commissioning the probe system; a volt meter can be connected directly to the
driver through the 3.5 mm standard audio socket to display the gap voltage at the
point of installation and the probe mechanical gap can then be adjusted to suite the
application.
The cable system incorporates snap lock connectors which require no torqueing and
provide a shake proof solution important for heavy industrial applications. The double
screened cable offers robustness in combination with high immunity to interference
and optional stainless steel convoluted armour is available for applications or
environments where cable protection is paramount.
DS 1246
Measurement Range: 0.0 mm to 2.5 mm Linear voltage range: -1.0 V to -19.0 V for 0.254 mm
Standard Option Standard Option (10 mil) to 2.54 mm (100 mil)
Measurement Range: 0.0 mm to 4.0 mm Linear voltage range: -1.0 V to -16.0 V for 0.254 mm
Half Sensitivity Option Half Sensitivity Option (10 mil) to 4.064 mm (160 mil)
Interchangability: Maximum interchangability error Power supply: < 0.3 mVout / Vsupply
replacing either probe, sensitivity
extension cable or driver in
calibrated system is ± 5 %. Power consumption: 3 mA typ, 7 mA max
Reference Target Material: ANSI 4140 Storage Temp Range: -40 °C to +90 °C
Probe
Straight Mount
Reverse Mount
3
© Copyright 2015 Sensonics Ltd
XPR04
4
© Copyright 2015 Sensonics Ltd
XPR04
5
© Copyright 2015 Sensonics Ltd
XPR04
Sensonics Ltd
Northbridge Road
Berkhamsted
Herts, HP4 1EF
United Kingdom
Tel: +44 (0)1442 876833
6 Fax: +44 (0)1442 876477