0% found this document useful (0 votes)
65 views6 pages

Senturion XPR04 Proximity Probe: Condition Monitoring Solutions

Uploaded by

Nguyen Luan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views6 pages

Senturion XPR04 Proximity Probe: Condition Monitoring Solutions

Uploaded by

Nguyen Luan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Senturion XPR04 Proximity Probe

TECHNICAL
INFORMATION

CONDITION
MONITORING
SOLUTIONS

 Switch selectable system cable lengths 5m, 7m and 9m.


 LED indication of selected length.
 3.5mm socket for gap voltage monitoring.
 Double screened cable for high noise immunity.
 Snap lock and shake proof cable connection.
 Low profile driver for easy local integration to machine (Din rail mount opt).
 Excellent repeatability on replacement of probe, extension or driver.
 Compliant with standard API 670.

The XPR04 proximity probe system is made up of a calibrated probe, extension cable
and driver. Utilising the eddy current principle, this combination forms a tuned circuit
with the target material and variations in probe face to target distance are detected in
this circuit by the driver. This provides a linearised voltage output proportional to
target gap with a nominal sensitivity of 7.87 mV/um and a range of up to 2.5 mm. This
type of measurement system provides highly accurate (resolution typically less than
one micro-meter) vibration and relative positional measurements, for harsh
environments up to 180 °C.

The driver unit offers selectable system lengths of 5 m, 7 m or 9 m, with a front panel
green LED indicating the selected option. The gap voltage monitoring socket assists
with commissioning the probe system; a volt meter can be connected directly to the
driver through the 3.5 mm standard audio socket to display the gap voltage at the
point of installation and the probe mechanical gap can then be adjusted to suite the
application.

The cable system incorporates snap lock connectors which require no torqueing and
provide a shake proof solution important for heavy industrial applications. The double
screened cable offers robustness in combination with high immunity to interference
and optional stainless steel convoluted armour is available for applications or
environments where cable protection is paramount.

DS 1246

1 1 © Copyright 2015 Sensonics Ltd


XPR04

System Performance Driver

Measurement Range: 0.0 mm to 2.5 mm Linear voltage range: -1.0 V to -19.0 V for 0.254 mm
Standard Option Standard Option (10 mil) to 2.54 mm (100 mil)

Measurement Range: 0.0 mm to 4.0 mm Linear voltage range: -1.0 V to -16.0 V for 0.254 mm
Half Sensitivity Option Half Sensitivity Option (10 mil) to 4.064 mm (160 mil)

Linearity: ± 1%, -1.0 V to -19.0 V System length selection: Internal switch 5 m, 7 m or 9 m


(% of FS) ± 2%, 0 °C to +150 °C @ -10.0V
System length indication: Green LED lamp
Std Sensitivity: 7.87 V/mm (200 mV/mil) ± 1 %
Power supply range: -16.0 Vdc to -28.0 Vdc
Half Sensitivity: 3.94 V/mm (100 mV/mil) ± 1 % Note: Output voltage is limited
to 1.2 V below supply voltage
Resolution: <0.001 mm when supply is < -21.5 V.

Interchangability: Maximum interchangability error Power supply: < 0.3 mVout / Vsupply
replacing either probe, sensitivity
extension cable or driver in
calibrated system is ± 5 %. Power consumption: 3 mA typ, 7 mA max

Available system lengths: 5 m, 7 m and 9 m Output impedance: 75 Ohms

Cable length tolerance Monitor Output Impedance: 10 KOhm


Probe (1 metre): 1.0 m to 1.5 m
Cable Extension (4 metre): 4.0 m to 4.4 m Sensor Connector type: Self Locking Miniature Male
Cable Extension (6 metre): 6.0 m to 6.6 m Coaxial
Cable Extension (8 metre): 8.0 m to 8.8 m
Monitor Connector type: 3.5 mm audio jack
Frequency Response: DC to 10 kHz
Mounting: Din Rail or Plate
Maximum Cable Length: 330 m based on 120 pF/m at
<10 kHz and 500 um pk-pk. Mass: 250 grams
3000 m based on 120 pF/m at
<1 kHz and 500 um pk-pk. Operating Temp Range: -30 °C to +90 °C

Reference Target Material: ANSI 4140 Storage Temp Range: -40 °C to +90 °C

Probe

Probe tip diameter: 8.0 mm

Probe tip material: PPS 40 % Glass Filled

Probe body material: Stainless steel

Available probe body lengths: 20 mm to 250 mm


0.8 in to 9.6 in

Cable type: Triaxial 75Ohm Coaxial


FEP outer jacket
3.2 mm outer diameter

Armoured option: Convoluted Stainless Steel


6.4 mm outer diameter
Typical 5m system performance
25 °C
Probe Resistance : 3.1 Ohms ± 0.2 Ohm
50 °C
150 °C or 0 °C
Operating Temp Range: -30 °C to +180 °C

Storage Temp Range: -40 °C to +180 °C

Minimum target diameter: 16 mm

Effect of target curvature: +2 % for shaft diameter 150 mm


+5 % for shaft diameter 25 mm

Magnetic field effect: <1 % at 110 mT

Connector Female Miniature Coaxial

Typical 5m system performance


2
© Copyright 2015 Sensonics Ltd
XPR04

Probe Mechanical Configuration

Straight Mount

Reverse Mount

Extension Cable Mechanical Drawing

3
© Copyright 2015 Sensonics Ltd
XPR04

Driver Mechanical Configuration

4
© Copyright 2015 Sensonics Ltd
XPR04

Probe Ordering Information

5
© Copyright 2015 Sensonics Ltd
XPR04

Driver Ordering Information

Extension Cable Ordering Information

Sensonics Ltd
Northbridge Road
Berkhamsted
Herts, HP4 1EF
United Kingdom
Tel: +44 (0)1442 876833
6 Fax: +44 (0)1442 876477
© Copyright 2015 Sensonics Ltd www.sensonics.co.uk