Transformer Test Report: Transformers Technical Data Field Service Representive
Transformer Test Report: Transformers Technical Data Field Service Representive
Transformer Test Report: Transformers Technical Data Field Service Representive
Unit
Manufacture : Rated Power : MVA
Type : Rated voltage HV : kV
Serial No. : Rated voltage LV : kV
Year : Rated current HV : A
Standard : Rated current LV : A
O
% Impedance (85 C) : No. of phase :
Temp. rise : Rated frequency : Hz
Oil in transformer : Vector group symbol :
Total mass : No. of tap :
Cooling type : Nominal Tap :
Note :
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
VISUAL INSPECTION AND MECHANICAL Field Service Representive
VISUAL INSPECTION
1 Body/Tank Condition o o o
2 Paint Condition o o o
3 Name Plate o o o
4 Rating plate o o o
5 Radiator panel/fins o o o
6 Cooling Fans o o o
7 Conservator o o o
8 Bushing HV / LV o o o
9 Termination and Cable box o o o
10 HV Cable Tightening Torque o o o
11 LV Cable Tightening Torque o o o
12 Tap Changer o o o
13 Winding Temperature indicator o o o
14 Oil Temperature Indicator o o o
15 Oil Level Indicator Main Coservator o o o
16 Leakage o o o
17 Buchholz Relay o o o
18 Pressure Relief Device Main Tank o o o
19 Radiator valve o o o
20 Oil Filling Valve o o o
21 Oil Sampling device o o o
22 Air Breather with silica Gel o o o
23 Drain Valve o o o
Name
Date
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
INSULATION RESISTANCE MEASUREMENT AND POLARIZATION INDEX (PI) Field Service Representive
HV – Ground
LV - Ground
HV – LV
Guidelines for evaluating transformer insulation using value: (STANDARD: WESTING HOUSE)
Acceptance Criteria :
Guidelines for evaluating transformer insulation using index polarization value: (STANDARD: ANSI C57.125-1991)
Test Result :
Measurement used :
Signature
Page /
TESTING AND COMMISSIONING TRANSFORMER SERVICES DIVISION
LV SIDE
R Meas (mΩ) R Dev (%) R Meas (mΩ) R Dev (%) R Meas (mΩ) R Dev (%)
TAP
A A B B C C
1
Name
Date
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
TURN TRANSFORMATION RATIO TEST / RATIO TEST & VECTOR GRUP TEST Field Service Representive
Measured Ratio
Tap HV LV Theoritical
Dev. (%) Dev. (%) Dev. (%)
Position Ratio A–B B–C C–A
Volt (± 0.5%) (± 0.5%) (± 0.5%)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Acceptance Criteria : Deviation between theoritical ratio and measured ratio within 0.5%
Result :
Equipment used :
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
TURN TRANSFORMATION RATIO TEST / RATIO TEST & VECTOR GRUP TEST Field Service Representive
Signature
Page /
Tan Delta
Signature
Page /
Page 0
TRANSFORMER TEST REPORT SERVICES DIVISION
Auxiliary Function Test Field Service Representive
1. SPECIFICATION
NO Material Type / Specification Result
1 Oil Level Indicator Main Conservator
2 Oil Temperature Indicator
3 Winding Temperature Indicator
4 Buchholz Relay
5 Pressure Relief Device 1
6 Relay OLTC Trip
2. VISUAL INSPECTION
NO Construction Installed/ Not Installed Result
1 Panel Control Box
2 Teminal Block
3 Thermal Relay
4 MCB
5 Selector Switch
6 Cable Conection
3. ELECTRICAL FUNCTION
No Description Result
1 Bucholz Alarm / Trip
2 Oil Temperature Alarm / Trip
3 Winding Temperature Alarm / trip
4 Pressure Relief Device 1 Contact Trip
5 Relay OLTC Trip
6 Oil Level Indicator Main Consevator/OLTC
7 Fans Operation ON/AUTO
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
Differential Transformer Stability Test Field Service Representive
STABILITY TEST
Technical Data Protection Relay
Device Identification Main Protection Relay
Identification
Manufacture
Device Type
Serial Number
Ratio CT HV
Ratio CT HV
Stability Diagram
MVA
KV KV
RELAY
400 V
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
SFRA Analyzer Field Service Representive
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
SFRA Analyzer Field Service Representive
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
SFRA Analyzer Field Service Representive
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
BDV Test OIL Field Service Representive
WATER CONTENT
Tem OLI °C Ppm / %
Result :
Equipment used :
Signature
Page /
TRANSFORMER TEST REPORT SERVICES DIVISION
DGA Test OIL Field Service Representive
Signature
Page /