Minerva Marine: M600Ex Intrinsically Safe Fire Detectors
Minerva Marine: M600Ex Intrinsically Safe Fire Detectors
Minerva Marine: M600Ex Intrinsically Safe Fire Detectors
MINERVA® Marine
Features:
Intelligent Universal Smoke/Heat/CO detector
Low profile, discreet and unobtrusive
Superior performance and reliability
Designed for fast, easy installation
Optional locking kit
May be used in systems that meet BS5839 Pt1
Integral and remote alarm LED
Certified to ATEX: Ex II1GD and Cenelec:
Ex ia IIC T5/Ex iaD 20 T100oC
Complies to EN54-7 for Smoke Detectors and
EN54-5 for Heat Detectors
Fire Detection
PSF122UM.qxp 02/01/2009 11:44 Page 2
General Application
Included within the range is the High Performance Optical Smoke As each type of fire detector responds to a particular ‘fire product’ the
(HPO) Detector and a combined Carbon Monoxide and Heat Detector. relative speed of response of the detector is therefore dependent upon
the type of fire being detected. The range of M600Ex detectors have
The complete range has been designed to meet the requirements of been designed to provide the earliest possible warning of a fire
BS (British Standards) and EN (European Standards) for fire condition, with a minimum possibility of false/unwanted alarms.
detectors. The detectors also carry the new CE mark.
As smoke is normally present at an early stage in most fires, smoke
M600Ex Series Conventional Detectors type detectors are therefore considered the most useful. When
The M600Ex Series provides the detector part of an automatic fire considering the type of smoke detector for the application, the
detection system, as defined in BS5839 Pt1:2002. The M600Ex probable type of fuel for the fire should be considered. For general fire
Series Conventional or two state detector is one that provides two detection, where there is an equal possibility of either a ‘fast’ or ‘slow’
output states to the controller, either ‘normal’ or a ‘fire alarm’ fire developing, the intelligent high performance optical detector
condition. provides an excellent detection response.
The detectors along with callpoints are grouped into zones, with each In situations where the installation of smoke detectors would cause an
zone being connected to the control panel, by a two wire circuit. Each unacceptable level of false alarms (i.e. kitchens, laundry areas) heat
zone having a separate zone indicator at the control panel. Safety detectors may be installed. The M600Ex series provides a selection of
barriers are used to maintain the intrinsically safe status of the circuit heat detectors, from Rate of Rise to fixed temperature.
under all conditions.
Because of the wide variety of applications that fire detectors are
expected to cover, it is recommended that reference to BS5839
Pt1:2002 is made to aid selection.
PSF122UM.qxp 02/01/2009 11:44 Page 3
Environmental Approvals
Operating Temp. Range: -20oC to +70oC These detectors have the following approvals:
-10oC to +55oC (MDU601Ex only) ABS: American Bureau of Shipping
Storage Temp.: -25oC to +80oC BV: Bureau Veritas
-20oC to +55oC (MDU601Ex only) DNV: Det Norske Veritas
Relative Humidity: 95% non condensing KRS: Korean Register of Shipping
90% non condensing (MDU601Ex only) LRS: Lloyds Register of Shipping
CCS: China Classification Society
Electrical NKK: Japanese Register of Shipping
Supply Voltage: 14 to 28Vd.c. GL: Germamischer Lloyd
Quiescent Current: 100µA typical MCA: Maritime and Coastguard Agency
Alarm Current: 48mA typical RMRS: Russian Maritime Register of Shipping
Reset Time: 0.5 - 5 seconds
Wiring Connections: SEM Terminal 2 x 1.5mm2
109mm
43mm