P2 V23079 Relay: 108-98002 Sept 06 Rev. D Ecoc: Jm10
P2 V23079 Relay: 108-98002 Sept 06 Rev. D Ecoc: Jm10
P2 V23079 Relay: 108-98002 Sept 06 Rev. D Ecoc: Jm10
108-98002
Sept 06 Rev. D
ECOC: JM10
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Index
Dimensions 4
Coil Operating Range 5
Relay Code 6
Coil Data and Ordering Information 7
UL 508 File No. E 111441 Contact Data 9
UL 60950 Insulation 10
General Data 10
IEC/EN60950 IEC Ref. Cert. No. 3271 Packing 12
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Features
• Standard telecom relay (ringing and test access)
• Slim line 15 x 7.5 mm, 0.590 x 0.295 inch
• Switching current 5 A
• 2 changeover contacts (2 form C / DPDT)
• Bifurcated contacts
• Immersion cleanable
• High sensitivity results in low nominal power
consumption 140 mW for non-latching and latching
with 2 coils 70 mW for latching with 1 coil
• For single coil version:
• Surge voltage resistance between
contact and coil for single coil version:
• 2.5 kV (2 / 10 µs) meets the Telcordia
Requirement GR-1089
• 1.5 kV (10 / 160 µs) meets FCC Part 68
Options
• 1500 Vrms between open contacts
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Dimensions Dimensions in mm
THT THT SMT long terminals SMT long terminals SMT short terminals SMT short terminals
V23079-x1xxx-B301 V23079-x2xxx-B301 V23079-x1xxx-B301 V23079-x2xxx-B301 V23079-x1xxx-B301 V23079-x2xxx-B301
standard coil overmolded coil standard coil overmolded coil standard coil overmolded coil
mm inch mm inch mm inch mm inch mm inch mm inch
L 14.5 ± 0.10 0.570 ± 0.004 14.6 ± 0.10 0.575 ± 0.004 14.5 ± 0.10 0.570 ± 0.004 14.6 ± 0.10 0.575 ± 0.004 14.5 ± 0.10 0.570 ± 0.004 14.6 ± 0.10 0.575 ± 0.004
W 7.2 ± 0.10 0.283 ± 0.004 7.2 ± 0.10 0.283 ± 0.004 7.2 ± 0.10 0.283 ± 0.004 7.2 ± 0.10 0.283 ± 0.004 7.2 ± 0.10 0.283 ± 0.004 7.2 ± 0.10 0.283 ± 0.004
H 9.8 ± 0.10 0.385 ± 0.004 9.5 ± 0.10 0.374 ± 0.004 10.4 ± 0.15 0.409 ± 0.006 9.9 ± 0.10 0.390 ± 0.004 10.4 ± 0.15 0.409 ± 0.006 9.9 ± 0.10 0.390 ± 0.004
T 3.25 – 0.25 0.128 – 0.010 3.25 – 0.25 0.128 – 0.010 N/A N/A N/A N/A N/A N/A N/A N/A
T1 N/A N/A N/A N/A 5.52 ± 0.15 0.217 ± 0.006 5.52 0.217 ± 0.006 5.52 0.217 ± 0.006 5.52 0.217 ±0.006
T2 N/A N/A N/A N/A 9.4 ± 0.15 0.370 ± 0.006 9.4 ± 0.15 0.370 ± 0.006 7.4 ± 0.15 0.291 ± 0.006 7.4 ± 0.15 0.291 ±0.006
Tw 0.5 ± 0.05 0.020 ± 0.002 0.5 ± 0.05 0.020 ± 0.002 0.5 ± 0.05 0.020 ± 0.002 0.5 ± 0.05 0.020 ± 0.002 0.5 ± 0.05 0.020 ± 0.002 0.5 ± 0.05 0.020 ±0.002
S 0.55 – 0.15 0.022 – 0.006 0.45 0.018 ± 0.002 N/A N/A N/A N/A N/A N/A N/A N/A
P2 SMT S
0,9 ±0,1
Note: Hole for pin 6 and 7 Note: Solder pad for pin 6 and 7 Note: Solder pad for pin 6 and 7
only for latching with 2 coils. only for latching with 2 coils only for latching with 2 coils
Basic grid 2.54 mm
Terminal assignment
Relay – top view
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
2.4
2.2 Uop. min. = Lower limit of the operative range of
2
1.8
the coil voltage (reliable operate voltage)
1.6 For latching relays Uset min. resp. Ureset min.
1.4
1.2
Urel. min. = Lower limit of the operative range of
1 Unom. nominal coil voltage the coil voltage (reliable release voltage)
0.8
0.6 Uop. min.
0.4
0.2
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
2.8
140 mW
2.6
Umax. at 0 A
2.4 Umax. at 2 x 1 A
2.2 Umax. at 2 x 2 A
2
Coil Voltage [U/Unom]
1.8
1.6
1.4
1.2
0.6
Uop. min.
0.4
Urel. min.
0.2
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
200 mW
2.8
2.6 Umax. at 0 A
2.4 Umax. at 2 x 1 A
2.2
Umax. at 2 x 2 A
2
Coil Voltage [U/Unom]
1.8
1.6
1.4
1.2
1
Unom. nominal coil voltage
0.8
0.6
Uop. min.
0.4 Urel. min.
0.2
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Relay Code
V 2 3 0 7 9
Identification of the
Miniature Relay P2
Relay type
Coil type
1 = standard coil; B1, E1, F1, J1, H1
2 = overmolded coil, A1*, A2, C1*, D1*, D2, E2, G1*, G2
(only monostable versions, i.e. relay type A, D, G)
*both standard and overmolded coil possible
Coil number
Monostable, 1 coil Latching, 1 coil Latching, 2 coils
008 = 3 V nominal voltage 108 = 3 V nominal voltage 218 = 2.4 V nominal voltage
011= 4.5 V 111 = 4.5 V 208 = 3 V
001 = 5 V 101 = 5 V 211 = 4.5 V
002 = 6 V 102 = 6 V 201 = 5 V
006 = 9 V 106 = 9 V 202 = 6 V
003 = 12 V 103 = 12 V 206 = 9 V
005 = 24 V 105 = 24 V 203 = 12 V
205 = 24 V
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Nominal Operate/set voltage range Release/ Coil Coil Relay Tyco part
voltage reset voltage power Resistance code number
Unom Minimum
Minimum Maximum
voltage Umin voltage Umax
Vdc Vdc Vdc Vdc mW Ω / ± 10 %
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Nominal Operate/set voltage range Release/ Coil Coil Relay Tyco part
voltage reset voltage power Resistance code number
Unom Minimum
Minimum Maximum
voltage Umin voltage Umax
Vdc Vdc Vdc Vdc mW Ω / ± 10 %
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Contact Data
resistive load
DC Voltage [Vdc]
DC current [A]
All specifications subject to change. Consult Tyco Electronics for latest specifications. of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Insulation
Standard Version High dielectric Version
Insulation resistance at 500 Vdc > 10 Ω9
> 109 Ω
Dielectric test voltage (1 min)
between coil and contacts (Relay with 1 coil) 1500 Vrms 1500 Vrms
between adjacent contact sets 1000 Vrms 1500 Vrms
between open contacts 1000 Vrms 1500 Vrms
Surge voltage resistance
according to Telcordia TR-NWT-001089 (2 /10 µs)
between coil and contacts (Relay with 1 coil) 2500 V 2500 V
between adjacent contact sets 2500 V 2500 V
between open contacts 2000 V 2500 V
according to FCC 68 (10/160 µs)
between coil and contacts (Relay with 1 coil) 1500 V
between adjacent contact sets 1500 V
between open contacts 1500 V
Insulation according to IEC / EN 60950 Basic insulation
Clearance 1.3 mm
Creepage distance 2.5 mm
General Data
Operate time at Unom typ. / max. 3 ms / 4 ms
All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
180 °C
Temperature °C
130 °C forced
cooling
100 °C
Time (s)
Infrared Soldering: Temperature/Time Profile
(Lead and Housing Peak Temperature)
All specifications subject to change. Consult Tyco Electronics for latest specifications. 11 of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Packing Dimensions in mm
Reel dimension
All specifications subject to change. Consult Tyco Electronics for latest specifications. 12 of 14
AXICOM
Telecom-, Signal and RF Relays 108-98002 Rev. D
P2 V23079 Relay
Cradle Relays
FT2 / FU2 Relays
Extremely reliable and mature relay family of 1st generation for
3rd generation non polarized, non latching 2 c/o telecom relay with various signal switching applications. Available as non polarized,
bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power polarized / latching and relay with AC coil. The benefit is the possibility
consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as of combining various contact sets from 1 up to 6 poles, single and bi-
through hole and surface mount type. Dielectric strength fulfills the furcated contacts, different contact materials with a coil voltage range
Telcordia requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected
part 68 (1,5 kV – 10 / 160 µs). The FT2/FU2 relay is tested according and hermetically sealed versions, with plug in or solder terminals
CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. and are capable to switch currents up to 5 A. Forcibly guided (linked)
Dimensions approx. 15 x 7,5 mm board space and 10 mm height. contact sets optional. Dielectric strength 500 Vrms. Dimensions from
approx. 19 x 24 to 19x35 mm board space and 30 mm height.
FP2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, Other Relays
available as non latching or latching relay with 1 or 2 coils. Nominal
We offer a variety of different relay families for maintenance and
voltage range from 3 ... 48 V, coil power consumption of 80 ... 260
replacement purposes. These relays are up to 60 years old now, such
mW for the high sensitive version, 140... 300 mW for the standard
as Card Relay SN (V23030 / V23031 series), Small General Purpose
version, latching relays with 1 coil 100 mW.. The FP2 Relay is available
Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and
as through hole type and capable to switch loads up to 60 W/62,5 VA.
V23163 ... V23167 series). Accessories like sockets, hold down springs,
Dielectric strength fulfills FCC part 68 (1,5 kV – 10 / 160 µs). The FP2
etc. optional.
is tested according CECC/IECQ approved. Dimensions approx. 14 x
9 mm board space and 5 mm height.
HF3 Relay
MT2 High performance low cost RF relay with excellent RF characteristics.
Available with an impedance of 50 and 75 Ohm. Suitable for frequen-
2nd generation non polarized, non latching 2 c/o telecom and si-
cies up to 3 GHz. Actually smallest RF relay available combining small
gnal relay with bifurcated contacts. Nominal voltage range from
size, excellent RF performance and SMD solderability. Available as non
3 ... 48 V, coil power consumption 150/200/300/400 and 550 mW.
latching or latching relay with 1 or 2 coils and a nominal coil voltage
Dielectric strength fulfills the requirements according FCC part 68
range from 3 ... 24 V, coil power consumption 140 mW, latching relays
(1,5 kV – 10 / 160 µs).
with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm.
Dimensions approx. 20 x 10 mm board space and 11 mm height.
All specifications subject to change. Consult Tyco Electronics for latest specifications. 13 of 14
Tyco Electronics Logistics AG
Werk Axicom Au
Seestrasse 295
CH-8804 Au-Wädenswil / Switzerland
Phone +41 44 782 91 11
Fax +41 44 782 90 00
E-mail: [email protected]
Tyco Electronics
Paulsternstrasse 26
D-13629 Berlin / Germany
Phone +49 30 386 38573
Fax +49 30 386 38575
E-mail: [email protected]