Aegis® Shaft Grounding Ring Bearing Protection Handbook: Edition 2
Aegis® Shaft Grounding Ring Bearing Protection Handbook: Edition 2
Aegis® Shaft Grounding Ring Bearing Protection Handbook: Edition 2
AEGIS® Shaft Grounding Ring technology is the only technology that combines both contact and non-contact
nanogap technology to reliably protect bearings from electrical discharges that cause pitting, frosting and fluting
damage. AEGIS® Ring Technology uses proprietary conductive micro fibers arranged circumferentially around the
motor shaft and secured in our patented AEGIS® FiberLock™ channel which protects them during operation. The
following patents apply: 8199453, 8169766, 7193836, 7136271, 7528513, 7339777, and other patents pending.
WARRANTY
Units are guaranteed for one year from date of purchase against defective materials and workmanship. Replacement
will be made except for defects caused by abnormal use or mishandling. All statements and technical information
contained herein, or presented by the manufacturer or their representative are rendered in good faith. User must
assume responsibility to determine suitability of the product for intended use. The manufacturer shall not be
liable for any injury, loss or damage, direct or consequential arising out of the use, or attempt to use the product.
SAFETY
Follow all workplace safety policies and procedures applicable to electric motor repair and for all hazardous
operations. Wear all applicable personal protective equipment (PPE) required by the applicable law. Employees
should be informed of the relevant safety rules and employers should enforce compliance. The manufacturer
shall not be liable for any injury, loss or damage, direct or consequential arising out of the use, or attempt to use
the product or procedures described in this manual.
No part of this book may be reproduced without permission in writing from Electro Static Technology, except by a reviewer
who may quote brief passages or reproduce illustrations in a review with appropriate credit; nor may any part of this book be
reproduced, stored in a retrieval system, or transmitted in any form or by any means-electronic, photocopying, recording, or
other-without permission in writing from Electro Static Technology.
This book is generally reviewed every year and updated. Comments and suggestions are invited. Any errors or omissions in
the data should be brought to the attention of the Editor. Additions and corrections to the Handbook in print will be in the
Handbook published the following printed edition and, as soon as verified, on the Electro Static Technology Internet Web site.
Disclaimer-Application notes are intended as general guidance to assist with proper application of AEGIS® Bearing Protection Ring to
protect motor bearings. All statements and technical information contained in the application notes are rendered in good faith. User
must assume responsibility to determine suitability of the product for its intended use.
ISBN 978-0-9891315-3-7
TABLE OF CONTENTS
Introduction-New Motor and Repair Standards for Inverters 4
Testing for Shaft Voltage 25-30
Probe Tip Installation & ScopeMeter Set Up 31-35
Selecting the Correct Size Ring 36
AEGIS® Bearing Protection Ring Parts List 37-45
Engineering Specification 46
Conversion Table - Inches - Metric 47
www.est-aegis.com/bearing
Use of the EASA logo expresses membership only and not endorsement by EASA of the content in this handbook.
A ssess motors with shaft voltage testing when operated on variable frequency drives
E nsure that best practices are followed for bearing protection during the repair
Customers demand repair, testing and analysis services to ensure uptime and reliability and often
recognize the leading service providers with their business. Therefore, the value added service offerings
explained in this manual will help the motor repair and service company meet customer requirements
by offering best practices in motor repair for VFD driven equipment.
• Adding AEGIS® Ring Technology to any new motor or motor repair for VFD driven motors is the best practice for motor
shaft grounding in order to protect bearings from shaft voltages and bearing currents.
• In addition to AEGIS® rings, motors above 100 HP (75kW) should have the opposite bearing isolated to prevent high
frequency circulating currents.
• When the recommendations are followed as part of the best repair practices, customers may be assured that their
motors are repaired to the highest standards of service and reliability.
• Operations and facilities engineers and managers count on the motor service and repair shop to keep abreast of the
latest technology and best practices.
• AEGIS® Shaft Grounding Ring technology, proven in over a million installations worldwide, is an innovative and “one-
of-a-kind” technology designed specifically for VFD induced bearing currents. The concept won first prize in 2007 from
the IEEE in a paper titled “Design Aspects of Conductive Microfiber Rings for Shaft Grounding Purposes”.
Bearing Inspection Report: Cutting and inspecting every bearing in motors that come in for repair,
especially when the motor is operated on a variable frequency drive, will often provide vital information needed to make
the best repair recommendations. Detection of electrical discharge machining pits or fluting in the bearings often requires
repair services referred to in this manual.
• Installing a Shaft Grounding Ring (AEGIS® SGR or iPRO) on any motor operated on variable frequency drives (VFD)
• Machining for an internal or external mounting of AEGIS® rings
• Isolating a motor bearing with an insulated sleeve; coating bearing housing with insulating material; adding a hybrid
ceramic ball bearing or ceramic coated bearing to the repair for motors over 100 HP (75kW).
Provide Testing and Analysis Services: Offering the latest testing and analysis services for motors
operated on variable frequency drives (VFD) improves system reliability and uptime. Services include vibration analysis,
thermography, and now shaft voltage testing services.
• New - Shaft Voltage Testing: Using a portable oscilloscope like the Fluke 190 series together with the AEGIS® Shaft
Voltage Probe kit allows a trained technician to easily measure shaft voltage on any VFD driven motor and detect if
there is a potential for bearing discharges.
• Best accomplished:
At the plant or facility while the motor is operating
At initial startup to detect shaft voltages and prevent possible future problems
After the motor is repaired with AEGIS® Shaft Grounding Rings to verify their effectiveness
Periodically as part of a preventative maintenance program
• Adding shaft voltage testing services to current vibration analysis, thermography or other testing compliments the
testing portfolio with an important value added service for customers.
460 VAC
50/60Hz
• Electric induction motors are designed for operation on 3 phase sine wave
power - either 50 or 60 Hz.
• The input power is balanced in frequency, phase (120 degree phase shift) and in
amplitude.
• Common mode voltage - the sum of the 3 phases always equal zero volts when
properly balanced.
Note: Bearing protection generally not needed except for large frame motors.
• When operated by VFD, the power to the motor is a series of positive and
negative pulses instead of a smooth sine wave.
• The input voltage is never balanced because the voltage is either 0 volts, positive,
or negative with rapid switching between pulses in all three phases.
• The common mode voltage is usually a “square wave” or “6 step” voltage wave
form.
Bearing Currents
a. Virtually any motor from fractional HP to large
motors may have bearing currents from this source.
a. Voltages can discharge through the motor bearings
resulting in EDM pitting and fluting failure.
motor’s bearings.
Ref: NEMA MG1 Part 31.4.4.3
Shaft Load
• Creates electrical bearing discharge currents. Rotor
Stator
Unbalanced
output
VFD Balanced
3-phase input
Stator
tato
Rotor
Roto
© 2013 Electro Static Technology
Shaft www.est-aegis.com
Patented Technology
AEGIS® Handbook | 7
About VFD Induced Shaft Voltages and Bearing Currents
• Voltages arc through the bearings, and electrical Common Mode Shaft Voltage Arc
Supply 480 v pk-pk 30 v pk-pk
discharge machining (EDM) creates thousands of pits
Rotor
fails Unbalanced
output
EDM Pits
Burnt Grease
Ring.
Bearing Currents
a. Usually present in very large machines only.
a. Circulate through the motor bearings, shaft to frame.
AC Induction Motors
NO VFD-
VFD OPERATION 50/60 Hz line operation
Motors up to and Motors over 100hp Motors over 500hp
including 100hp to 500hp (Medium Voltage-greater than Motors over 500 Frame
(Low Voltage) (Low Voltage-up to 600 volts AC) 600 volts AC) (Medium Voltage)
Bearing Current A Bearing Current A & B Bearing Current A, B & C Bearing Current C
AEGIS® iPRO
AEGIS® SGR AEGIS® SGR AEGIS® iPRO
(may not be needed)
Install AEGIS® SGR Install AEGIS® SGR opposite Install AEGIS® iPRO opposite Install AEGIS® iPRO opposite
on DE or NDE side of bearing insulation; side of bearing insulation; side of bearing insulation;
usually DE usually DE usually DE
n/a Isolate one bearing, usually Isolate one bearing, usually the Isolate one bearing, usually
the NDE to break the NDE to break the circulating the NDE to break the
circulating current path current path circulating current path
These discharges are so frequent (millions per hour) that before long the entire
Frosted Bearing Race bearing race becomes marked with countless pits known as frosting. A
phenomenon known as fluting may occur as well, producing washboard-like
ridges across the frosted bearing race. Fluting causes excessive noise and
vibration and in heating, ventilation, and air-conditioning systems, it is
magnified and transmitted by the ducting. Regardless of the type of bearing
or race damage that occurs, the resulting motor failure often costs many
thousands or even tens of thousands of dollars in downtime and lost
production.
Failure rates vary widely depending on many factors, but evidence suggests
Fluted Outer Bearing Race that a significant portion of failures occur only 3 to 12 months after system
startup. Because many of today’s AC motors have sealed bearings to keep out
dirt and other contaminants, electrical damage has become the most common
cause of bearing failure in AC motors with VFDs.
Bearing Inspection
1. Inspect the bearing and bearing cavity and retain a sample of the
lubricant if further analysis is warranted. Look for:
a. Contamination
b. Signs of excessive heat
c. Hardening of grease
d. Abnormal coloration (blackened grease)
e. Excess grease escaping the bearing
6. Frosting: This will appear to be a grey discolored line around all or part of
the bearing race and may be evident in the inner and outer race. The
discoloration may be caused by wear or by electrical EDM. Examination
under a microscope may be required to determine if the line is EDM or
not. If the motor was operated on a VFD with no bearing protection there
is a high likelihood that the frosting is from EDM.
1000x
Grounding
The AEGIS® Ring conducts harmful shaft voltages away from the bearings to
ground. Voltage travels from the shaft , through the conductive microfibers,
through the housing of the ring, through the hardware (or conductive epoxy)
used to attach the ring to the motor, to ground. All paths must be conductive.
STOP AEGIS® Rings should not operate over a keyway because the edges are very
sharp. For proper performance:
Adjust or change spacer and screw lengths to avoid the keyway; or
Fill the keyway (in the area where the AEGIS® microfibers will be in
contact with the shaft) with a fast-curing epoxy putty such as Devcon®
Plastic Steel® 5 Minute® Putty(SF).
Ohms test:
Place the positive and negative meter leads on the shaft at a place where
the microfibers will contact the shaft. Each motor will have a different
reading but in general you should have a maximum reading of less than
2 ohms. If the reading is higher, clean the shaft again and retest.
Treating the shaft of the motor prior to installing the AEGIS® Ring:
1. Shaft must be clean and free of any coatings, paint, or other
nonconductive material. The shaft must be clean to bare metal.
2. Thoroughly stir the silver coating.
Apply a light coat of the AEGIS® Colloidal Silver Shaft Coating to the
area where the AEGIS® microfibers are in contact with the motor
Colloidal Silver shaft. Apply evenly all around the shaft. Allow to dry. Coating will
Shaft Coating cure at room temperature in 16-20 hours or in 30 minutes at 120-
PN# CS015 200˚C. A heat gun will cure the materials in seconds.
3. Apply a second coat for best coverage. Allow to dry. After coating is
dry, install the AEGIS® Shaft Grounding Ring.
Follow all safety precautions. MSDS for CS015 available for
download at www.est-aegis.com
Install the AEGIS® SGR so that the aluminum frame maintains an even
clearance around the shaft. AEGIS® conductive microfibers must be in
contact with conductive metal surface of the shaft.
STOP
Do not use thread lock to secure the mounting screws as it may
compromise the conductive path to ground.
AEGIS® SGR for Low Voltage and iPRO for Medium Voltage Motors
Description: Description:
• Design Type: AEGIS® SGR • Design Type: AEGIS® iPRO
• Circumferential Conductive MicroFiber rows in • Circumferential Conductive MicroFiber rows in
FiberLock™ Channel FiberLock™ Channel
• Rows of fiber: 2 • Rows of fiber: 6
• Fiber overlaps shaft 0.030” (.76mm) • Fiber overlaps shaft 0.030” (.76mm)
• OAL: 0.295” (7.5mm) • OAL: 0.625” (15.875mm)
• OD: listed in AEGIS® Catalog • OD: Shaft + (refer to drawing)
Mounting: Mounting:
• Internal or External • Internal or External
• Select based on shaft diameter • Select based on shaft diameter
• Split or Solid versions available • Split or Solid versions available
• Custom brackets optional • Custom brackets optional
AEGIS® SGR Current Capability Chart AEGIS® iPRO Current Capability Chart
Current (amps)
60
50 200
40 150
30
100
20
50
10
0 0
0.5" (12.5mm) 1" (25mm) 2" (50mm) 4" (100mm) 8" (200mm) 2" (50mm) 4" (100mm) 8" (200mm) 16" (400mm) 32" (800mm)
Follow all safety precautions. MSDS for CS015 and EP2400 available for download at www.est-aegis.com
Follow AEGIS® best practices for motor shaft preparation and ring installation. Use AEGIS® Colloidal Silver
Shaft Coating when installing AEGIS® rings to enhance the shaft conductivity and help prevent oxidation.
Bearing
Retainer
Common AEGIS® Ring installation internal to the motor is on the motor’s bearing
AEGIS®SGR retainer. Installation can be done with bolt through hardware or AEGIS®
Conductive Epoxy.
Shaft For epoxy installation, bearing retainer must be clean & free of any coatings,
paint, or other nonconductive material where AEGIS® SGR will be mounted. This
Rotor End
is the discharge path to ground therefore metal to metal contact is essential.
Bracket
STOP
Do not use a substitute epoxy as only the AEGIS® EP2400 has been tested
and approved for AEGIS® ring installation.
Follow AEGIS® best practices for motor shaft preparation and ring installation. Use AEGIS® Colloidal Silver
Shaft Coating when installing AEGIS® rings to enhance the shaft conductivity and help prevent oxidation.
An o-ring or “v’” slinger may be installed against the AEGIS® Ring to help prevent excessive ingress of dirt,
dust or liquid.
Severe Duty Motors: Install Garlock SGi with AEGIS® Shaft Grounding
Bearing
Technology. For technical Information visit www.klozure.com
Isolator
• Garlock SGi – Shaft Grounding Bearing Isolator may be installed into a
bearing isolator cavity
• Motor End Bracket may be bored out to allow for Garlock SGi to be
installed Garlock SGi
• Solid or Split version available with AEGIS® SGR
Motors Greater than 100 HP (75 kW) For horizontally mounted motors with single
row radial ball bearings on both ends of the
sleeve motor:
• Non-Drive end: Bearing housing must be
isolated with insulated sleeve or coating or
use insulated ceramic or hybrid bearing to
disrupt circulating currents.
• Drive end: Install one AEGIS® Bearing
Protection Ring .
• AEGIS® Ring can be installed internally on
the back of the bearing cap or externally on
the motor end bracket.
• Use AEGIS® Colloidal Silver Shaft Coating
(PN# CS015) on motor shaft where fibers
touch.
Product recommendation:
Low Voltage Motors up to 500HP:
AEGIS® SGR
Install AEGIS® Ring on opposite end of insulation Low Voltage Motors over 500HP:
AEGIS®iPRO
Medium Voltage Motors: AEGIS® iPRO
PUMP
Ground
O T
T R Protection Ring.
A C
T U • AEGIS® Ring can be installed internally on
R
O
R the back of the bearing cap or externally on
R
E
N
the motor end bracket.
T
S • Colloidal Silver Shaft Coating PN CS015 is
required for this type of application.
Product recommendation:
Low Voltage Motors: AEGIS® SGR
Medium Voltage Motors: AEGIS® iPRO
PUMP
Ground
Head Shaft
Product recommendation: AEGIS® SGR
Stator
Stator
Rotor
Hollow Shaft
Insulated
Bearing
Carrier Thrust
• Upper Bearing: Bearing carrier must be Bearing
Protection Ring.
Stator
Stator
Rotor
Driven Equipment
Application notes are intended as general guidance to assist with proper application of AEGIS® Bearing Protection Ring to protect motor bearings.
All statements and technical information contained in the application notes are rendered in good faith. User must assume responsibility to
determine suitability of the product for its intended use.
AEGIS® Shaft Grounding Rings Provide Both Contact and Noncontact Grounding
The Only Product of its Kind
The AEGIS® Bearing Protection Ring’s patented Nanogap Technology ensures effective
® SGR electrical contact even when physical contact is broken . Only AEGIS® Nanogap
BEARING PROTECTION RING Technology provides both maintenance-free contact and noncontact bearing
protection for the normal service life of the motor’s bearings as well as the most
reliable operation of any shaft grounding technology.
Proprietary Conductive Microfibers Last for the Service Life of the Motor
The AEGIS® Bearing Protection Ring’s unique design features hundreds of thousands to
millions of specially engineered conductive microfibers that encircle the motor shaft. With
so many electrical transfer points the ring provides continuous electrical contact, whether
its fibers are physically touching the shaft or not. This patented “nanogap” technology
enables both contact and noncontact shaft grounding — 100% of the time.
AEGIS®
Ring Patented FiberLock™ Channel Secures and Protects Fibers
AEGIS’s patented, protective FiberLock™ channel locks the ring’s conductive microfibers
securely in place around the motor shaft, allowing them to flex without breaking. The
Shaft channel also helps protect the fibers from excessive dirt, oil, grease, and other contaminants.
FiberLock™
Channel
This mechanism is based on the Field emission is a form of quantum This process results from the
ability of electrons to “tunnel” tunneling whereby electrons cascading effect of secondary
across an insulating barrier, and move through a barrier in the electrons released by collisions
works for gaps smaller than 2 nm. presence of a high electric field. It and the impact ionization of gas
provides grounding across gaps of ions accelerating across gaps
2 nm to 5 μm. The electric field greater than 5 μm. This ionization
from the shaft voltages creates the creates negative and positive ions
conditions for the AEGIS® ring which neutralize the shaft voltage.
fibers to take advantage of field
emission electron transfer from
the shaft.
Manufacturer’s Specification
Fiber Flexibility AEGIS® Rings are constructed with patented AEGIS® FiberLock™ channel to allow
conductive micro fibers to bend and flex within their elastic design limits. Fibers
are distributed 360 degrees inside the FiberLock™ channel to provide maximum
shaft surface contact with multiple rows. Fiber length is designed with an optimal
shaft overlap of 0.030” (0.76mm).
Fiber wear Usually less than 0.001” in 10,000 hours. Fiber wear length is designed for expected
life of 200,000+ hours based on testing. Wear rate may vary depending on
conditions in individual applications. Fibers retain contact/noncontact function.
Friction Little or no frictional axial or radial fiber pressure applied to shaft. Extremely light
contact only. Designed for minimal friction with no reduction in motor
performance.
AEGIS® Bearing Protection Ring None
Maintenance Requirements
Oil and Grease on Motor Shaft Small amounts of oil and/or grease are acceptable as long as the shaft surface
remains conductive. Fibers are designed to maintain contact with the motor shaft
and “sweep” oil away from surface.
Dirt/dust Small amounts of dust and/or small particles are acceptable. Fibers “sweep”
particles from shaft surface during operation. Shaft surface must remain
conductive.
Directional rotation Motor may be operated in clockwise or counter clockwise rotation. Motor may
change directional rotation without limitations.
Maximum surface rate/RPM No Maximum rating - There is no theoretical RPM limit as there is virtually no
frictional contact with the shaft at high RPM. Verify any specific application with
AEGIS® engineering.
Maximum temperature rating 410 F/210 C - Verify application specific temperatures with AEGIS® engineering.
Minimum temperature rating -112 degrees F/-80C - Verify application specific temperatures with AEGIS®
engineering.
Humidity 0 to 90% - Verify application specific acceptable humidity with AEGIS® engineering
RoHS Test Results All materials used in manufacture of AEGIS® Rings are in compliance with Directive
2002/95/EC, Restriction of the use of certain Hazardous Substances in electrical
and electronic equipment. No RoHS banned substances are present in excess of
Directive 2002/95/EC for the the maximum concentration values (MCV).
Restriction of the use of certain 1. Following substances were found to be less than 0.1% by weight in
Hazardous Substances in electrical homogeneous materials (required by RoHS directive):
and electronic equipment applies Lead (Pb)
Mercury (Hg)
Hexavalent chromium (Cr(VI))
Polybrominated biphenyl (PBB)
Polybrominated diphenyl ether (PDPE)
2. Following substance is less than 0.01% by weight in homogeneous materials
(required by RoHS directive):
Cadmium (Cd)
Note: Request RoHS Certification Letter from [email protected] or call 1-866-
738-1857
Hazardous areas Not certified for hazardous environments (Class 1 Division 1, Division 2 or Class 1
Zone 1, Zone 2)
CE and UL requirements AEGIS® Rings are classified as a “component” and as such are not subject to the
requirements of any Directive. The application of CE or UL Mark is not applicable
to this component.
Shaft Voltage Test Report: Measuring the shaft voltage on VFD driven
motors provides the end user with valuable information to determine if there
is a potential risk of bearing damage from electrical bearing discharges.
Surveying and documenting shaft voltage readings and wave forms will assist
in determining the appropriate mitigation or solution.
Note: The best time for shaft voltage measurements are during initial start-up
in new or repaired motors operated by the VFD. Shaft voltage measurements
should be incorporated into preventive and predictive maintenance programs
and may be combined with vibration analysis, thermography or other services.
Set Amplitude
An EDM discharge pattern will show a climb in voltage and then a sharp vertical
line. The sharp vertical line shows the moment of discharge to ground. Each
motor will have its own unique parameters.
Control the vertical span of the displayed signal by adjusting the volts per
division. The signal peak to peak should all be displayed on the screen. 5V is a
good place to start and then adjust based on the conditions.
3. Place the SVP on one of the points and the probe grounding clip
on the other point.
5. If you plan to create a report for the customer, save the image.
AEGIS® Grounding
Simulator
1. Shaft must be clean & free of any coatings, paint or other nonconductive
material.
2. Secure the probe in place with magnetic base.
3. Align AEGIS® SVP on shaft end or side ensuring continuous contact.
Avoid keyway if possible.
4. Place oscilloscope grounding lead on bare metal of motor ensuring
conductive path to ground.
5. Save the image. Please refer to page 25 for this action.
Fits Fluke Voltage Probe VPS410 and VPS200; for other sizes see our website www.est-aegis.com
SVP-TIP-3000
5. Install the AEGIS® SVP tip over the 6. Secure the tip to the probe using the
probe tip thumb screw. Be careful not to over
tighten.
Connect 10:1
probe in Input A The following pages describe the parameters we use to
capture shaft voltages. Although not all meters have the same
options, the basic concept is the same.
Press the A button for Press F2 COUPLING to toggle DC Coupling will pick up
channel A. Menu will between the DC and AC DC and AC voltages.
appear at the bottom. Coupling.
Choose DC and press ENTER.
Press CLEAR to clear menu.
Press the SCOPE button. Press F2 READING. Cursor Use up/down arrows to
A menu will appear at the to desired channel and choose Peak and press
bottom. press ENTER. ENTER.
For standard NEMA or IEC frame motors, the AEGIS® uKIT is the best option.
It avoids most shaft shoulders and slingers/seals.
AEGIS® uKit includes 4 different bracket sizes to suit most situations.
If YES or NOT SURE, then the AEGIS® uKIT is a great options because it avoids the shaft shoulder area, any slingers/seals
or irregular shaped end bracket.
If NO, the ring can be mounted directly to the end bracket using screws or conductive epoxy.
If YES and you want to mount the ring to fit the shaft shoulder then you need to measure the length of the shoulder. See
note in red below. If still applicable, measure shaft shoulder diameter then refer to parts list (as shown above) to locate the
correct SGR part number.
Custom Option for Short Shaft Shoulders: If the
shaft shoulder is between .1875” and 0.375” we
(.295” thick)
offer a custom part with fibers closer to the back
of the ring. To order this option, add an “X” or “AX”
AEGIS® Ring
to the suffix of the part.
Shaft
Motor
End Example:
Bracket Standard SGR Short Shoulder SGR
PN: SGR-6.9-0A4W PN: SGR-6.9-0A4WX
• Screw on mounting - shaft length needs PN: SGR-6.9-0AW PN: SGR-6.9-0AWX
to be a minimum of 0.375” (9.5mm). PN: SGR-6.9-1 PN: SGR-6.9-1AX
PN: SGR-6.9-1A4 PN: SGR-6.9-1A4X
• Conductive epoxy mounting - shaft length PN: SGR-6.9-3FH PN: SGR-6.9-3FHAX
needs to be a mimimum of 0.395” (10.03mm).
If the shoulder is less than 0.1875”, then refer to the uKIT.
Accessories
pg.45 SVP - AEGIS® Shaft Voltage Probe
CS015 - AEGIS® Colloidal Silver Shaft Coating
EP2400 - AEGIS® Conductive Epoxy
Split Ring
AEGIS® SGR uKit Includes: Hardware for NEMA Motors also Include: Hardware for IEC Motors also Include:
(1) AEGIS® SGR Bearing Protection Ring (4) 5-40 x 3/8” flat head screws (4) 5-40 x 3/8” flat head screws
(4) universal brackets of each size - 16 total (4) 6-32 x 3/8” socket head cap screws (4) M4 x 10 socket head cap screws
Drill and tap hardware installation AEGIS® EP2400 Conductive Epoxy installation Solid Ring with 3 bracket installation
SGR-55-UKIT SGR-55-UKIT-2A4 55mm IEC 200L (2, 4, 6, 8 pole); IEC 225S, 225M (2 pole)
SGR-60-UKIT SGR-60-UKIT-2A4 60mm IEC 225S, 225M (4, 6, 8 pole) ; IEC 250M (2 pole)
SGR-65-UKIT SGR-65-UKIT-2A4 65mm IEC 250M (4, 6, 8 pole); IEC 280M, 280S, 315S, 315M,315L (2 pole)
SGR-75-UKIT SGR-75-UKIT-2A4 75mm IEC 280S, 280M (4, 6, 8 pole); IEC 355M, 355L (2 pole)
SGR-95-UKIT SGR-95-UKIT-2A4 95mm IEC 335L, 335M, 355L, 355M (4, 6, 8, 10 pole)
Solid Ring, Split Ring, and Bolt Through Mounting Dimensions in inches
Solid Ring with Split Ring* with Solid Ring Split Ring* Bolt Through* Min. Shaft Max. Shaft Outside Thickness
Conductive Epoxy Conductive Epoxy Catalog Number Catalog Number Catalog Number Diameter Diameter Diameter Max
Solid Ring with Split Ring* with Solid Ring Split Ring* Bolt Through* Min. Shaft Max. Shaft Outside Thickness
Conductive Epoxy Conductive Epoxy Catalog Number Catalog Number Catalog Number Diameter Diameter Diameter Max
SGR-6.9-0A6 0.311 0.355 1.580 0.295 1.576 SGR-79.9-0A6 3.186 3.230 4.080 0.295 4.076
SGR- 8.0-0A6 0.356 0.395 1.580 0.295 1.576 SGR-81.1-0A6 3.231 3.270 4.080 0.295 4.076
SGR-9.0-0A6 0.396 0.435 1.580 0.295 1.576 SGR-82.1-0A6 3.271 3.310 4.080 0.295 4.076
SGR-10.1-0A6 0.436 0.480 1.580 0.295 1.576 SGR-83.1-0A6 3.311 3.355 4.080 0.295 4.076
SGR-11.2-0A6 0.481 0.520 1.580 0.295 1.576 SGR-84.2-0A6 3.356 3.395 4.080 0.295 4.076
SGR-12.2-0A6 0.521 0.560 1.580 0.295 1.576 SGR-85.2-0A6 3.396 3.435 4.580 0.295 4.576
SGR-13.2-0A6 0.561 0.605 1.580 0.295 1.576 SGR-86.3-0A6 3.436 3.480 4.580 0.295 4.576
SGR-14.4-0A6 0.606 0.645 1.580 0.295 1.576 SGR-87.4-0A6 3.481 3.520 4.580 0.295 4.576
SGR-15.4-0A6 0.646 0.685 2.080 0.295 2.076 SGR-88.4-0A6 3.521 3.560 4.580 0.295 4.576
SGR-16.4-0A6 0.686 0.730 2.080 0.295 2.076 SGR-89.4-0A6 3.561 3.605 4.580 0.295 4.576
SGR-17.6-0A6 0.731 0.774 2.080 0.295 2.076 SGR-90.6-0A6 3.606 3.645 4.580 0.295 4.576
SGR-18.7-0A6 0.775 0.815 2.080 0.295 2.076 SGR-91.6-0A6 3.646 3.685 4.580 0.295 4.576
SGR-19.7-0A6 0.816 0.855 2.080 0.295 2.076 SGR-92.6-0A6 3.686 3.730 4.580 0.295 4.576
SGR-20.7-0A6 0.856 0.895 2.080 0.295 2.076 SGR-93.8-0A6 3.731 3.770 4.580 0.295 4.576
SGR-21.7-0A6 0.896 0.935 2.080 0.295 2.076 SGR-94.8-0A6 3.771 3.810 4.580 0.295 4.576
SGR-22.8-0A6 0.936 0.980 2.080 0.295 2.076 SGR-95.8-0A6 3.811 3.855 4.580 0.295 4.576
SGR-23.9-0A6 0.981 1.020 2.080 0.295 2.076 SGR-96.9-0A6 3.856 3.895 4.580 0.295 4.576
SGR-24.9-0A6 1.021 1.060 2.080 0.295 2.076 SGR-97.9-0A6 3.896 3.935 5.080 0.295 5.076
SGR-25.9-0A6 1.061 1.105 2.080 0.295 2.076 SGR-99.0-0A6 3.936 3.980 5.080 0.295 5.076
SGR-27.1-0A6 1.106 1.145 2.080 0.295 2.076 SGR-100.1-0A6 3.981 4.020 5.080 0.295 5.076
SGR-28.1-0A6 1.146 1.185 2.080 0.295 2.076 SGR-101.1-0A6 4.021 4.060 5.080 0.295 5.076
SGR-29.1-0A6 1.186 1.230 2.080 0.295 2.076 SGR-102.1-0A6 4.061 4.105 5.080 0.295 5.076
SGR-30.3-0A6 1.231 1.270 2.080 0.295 2.076 SGR-103.3-0A6 4.106 4.145 5.080 0.295 5.076
SGR-31.3-0A6 1.271 1.310 2.080 0.295 2.076 SGR-104.3-0A6 4.146 4.185 5.080 0.295 5.076
SGR-32.3-0A6 1.311 1.355 2.080 0.295 2.076 SGR-105.3-0A6 4.186 4.230 5.080 0.295 5.076
SGR-33.4-0A6 1.356 1.395 2.080 0.295 2.076 SGR-106.5-0A6 4.231 4.270 5.080 0.295 5.076
SGR-34.4-0A6 1.396 1.435 2.660 0.295 2.656 SGR-107.5-0A6 4.271 4.310 5.080 0.295 5.076
SGR-35.5-0A6 1.436 1.480 2.660 0.295 2.656 SGR-108.5-0A6 4.311 4.355 5.080 0.295 5.076
SGR-36.6-0A6 1.481 1.520 2.660 0.295 2.656 SGR-109.6-0A6 4.356 4.395 5.080 0.295 5.076
SGR-37.6-0A6 1.521 1.560 2.660 0.295 2.656 SGR-110.6-0A6 4.396 4.435 5.580 0.295 5.576
SGR-38.6-0A6 1.561 1.605 2.660 0.295 2.656 SGR-111.7-0A6 4.436 4.480 5.580 0.295 5.576
SGR-39.8-0A6 1.606 1.645 2.660 0.295 2.656 SGR-112.8-0A6 4.481 4.520 5.580 0.295 5.576
SGR-40.8-0A6 1.646 1.685 2.660 0.295 2.656 SGR-113.8-0A6 4.521 4.560 5.580 0.295 5.576
SGR-41.8-0A6 1.686 1.730 2.660 0.295 2.656 SGR-114.8-0A6 4.561 4.605 5.580 0.295 5.576
SGR-43.0-0A6 1.731 1.770 2.660 0.295 2.656 SGR-116.0-0A6 4.606 4.645 5.580 0.295 5.576
SGR-44.0-0A6 1.771 1.810 2.660 0.295 2.656 SGR-117.0-0A6 4.646 4.685 5.580 0.295 5.576
SGR-45.0-0A6 1.811 1.855 2.660 0.295 2.656 SGR-118.0-0A6 4.686 4.730 5.580 0.295 5.576
SGR-46.1-0A6 1.856 1.895 2.660 0.295 2.656 SGR-119.2-0A6 4.731 4.770 5.580 0.295 5.576
SGR-47.1-0A6 1.896 1.935 2.660 0.295 2.656 SGR-120.2-0A6 4.771 4.810 5.580 0.295 5.576
SGR-48.2-0A6 1.936 1.980 2.660 0.295 2.656 SGR-121.2-0A6 4.811 4.855 5.580 0.295 5.576
SGR-49.3-0A6 1.981 2.020 2.660 0.295 2.656 SGR-122.3-0A6 4.856 4.895 5.580 0.295 5.576
SGR-50.3-0A6 2.021 2.060 3.080 0.295 3.076 SGR-123.3-0A6 4.896 4.935 6.080 0.295 6.076
SGR-51.3-0A6 2.061 2.105 3.080 0.295 3.076 SGR-124.4-0A6 4.936 4.980 6.080 0.295 6.076
SGR-52.5-0A6 2.106 2.145 3.080 0.295 3.076 SGR-125.5-0A6 4.981 5.020 6.080 0.295 6.076
SGR-53.5-0A6 2.146 2.185 3.080 0.295 3.076 SGR-126.5-0A6 5.021 5.060 6.080 0.295 6.076
SGR-54.5-0A6 2.186 2.230 3.080 0.295 3.076 SGR-127.5-0A6 5.061 5.105 6.080 0.295 6.076
SGR-55.7-0A6 2.231 2.270 3.080 0.295 3.076 SGR-128.7-0A6 5.106 5.145 6.080 0.295 6.076
SGR-56.7-0A6 2.271 2.310 3.080 0.295 3.076 SGR-129.7-0A6 5.146 5.185 6.080 0.295 6.076
SGR-57.7-0A6 2.311 2.355 3.080 0.295 3.076 SGR-130.7-0A6 5.186 5.230 6.080 0.295 6.076
SGR-58.8-0A6 2.356 2.395 3.080 0.295 3.076 SGR-131.9-0A6 5.231 5.270 6.080 0.295 6.076
SGR-59.8-0A6 2.396 2.435 3.580 0.295 3.576 SGR-132.9-0A6 5.271 5.310 6.080 0.295 6.076
SGR-60.9-0A6 2.436 2.480 3.580 0.295 3.576 SGR-133.9-0A6 5.311 5.355 6.080 0.295 6.076
SGR-62.0-0A6 2.481 2.520 3.580 0.295 3.576 SGR-135.0-0A6 5.356 5.395 6.080 0.295 6.076
SGR-63.0-0A6 2.521 2.560 3.580 0.295 3.576 SGR-136.0-0A6 5.396 5.435 6.580 0.295 6.576
SGR-64.0-0A6 2.561 2.605 3.580 0.295 3.576 SGR-137.1-0A6 5.436 5.480 6.580 0.295 6.576
SGR-65.2-0A6 2.606 2.645 3.580 0.295 3.576 SGR-138.2-0A6 5.481 5.520 6.580 0.295 6.576
SGR-66.2-0A6 2.646 2.685 3.580 0.295 3.576 SGR-139.2-0A6 5.521 5.560 6.580 0.295 6.576
SGR-67.2-0A6 2.686 2.730 3.580 0.295 3.576 SGR-140.2-0A6 5.561 5.605 6.580 0.295 6.576
SGR-68.4-0A6 2.731 2.770 3.580 0.295 3.576 SGR-141.4-0A6 5.606 5.645 6.580 0.295 6.576
SGR-69.4-0A6 2.771 2.810 3.580 0.295 3.576 SGR-142.4-0A6 5.646 5.685 6.580 0.295 6.576
SGR-70.4-0A6 2.811 2.855 3.580 0.295 3.576 SGR-143.4-0A6 5.686 5.730 6.580 0.295 6.576
SGR-71.5-0A6 2.856 2.895 3.580 0.295 3.576 SGR-144.6-0A6 5.731 5.770 6.580 0.295 6.576
SGR-72.5-0A6 2.896 2.935 4.080 0.295 4.076 SGR-145.6-0A6 5.771 5.810 6.580 0.295 6.576
SGR-73.6-0A6 2.936 2.980 4.080 0.295 4.076 SGR-146.6-0A6 5.811 5.855 6.580 0.295 6.576
SGR-74.7-0A6 2.981 3.020 4.080 0.295 4.076 SGR-147.7-0A6 5.856 5.895 6.580 0.295 6.576
SGR-75.7-0A6 3.021 3.060 4.080 0.295 4.076 SGR-148.7-0A6 5.896 5.935 7.080 0.295 7.076
SGR-76.7-0A6 3.061 3.105 4.080 0.295 4.076 SGR-149.8-0A6 5.936 5.980 7.080 0.295 7.076
SGR-77.9-0A6 3.106 3.145 4.080 0.295 4.076 SGR-150.9-0A6 5.981 6.020 7.080 0.295 7.076
SGR-78.9-0A6 3.146 3.185 4.080 0.295 4.076
Custom Part-No Return Custom Part-No Return
SGR-1.875-NEMA SGR-1.875-NEMA-1A4 1.875” 284T, 286T, 324TS, 326TS, 364TS, 365TS 6.30” 1 AEGIS® SGR
1 mounting plate
SGR-2.125-NEMA SGR-2.125-NEMA-1A4 2.125” 324T, 326T, 404TS, 405TS 6.60”
3 screws (inches or metric)
SGR-2.375-NEMA SGR-2.375-NEMA-1A4 2.375” 364T, 365T, 444TS, 445TS, 447TS, 449TS 6.60” 3 washers
SGR-2.875-NEMA SGR-2.875-NEMA-1A4 2.875” 404T, 405T 7.30” 3 lock washers
3 spacers*
SGR-3.375-NEMA SGR-3.375-NEMA-1A4 3.375” 444T, 445T, 447T, 449T 7.60”
SPLIT
SGR-38-IEC SGR-38-IEC-2A4 38mm IEC 132S, 132M (2, 4, 6, 8 pole) 160mm 1 AEGIS® Split Ring SGR
SGR-42-IEC SGR-42-IEC-2A4 42mm IEC 160M, 160L (2, 4, 6, 8 pole) 160mm 1 split mounting plate
3 screws (inches or metric)
SGR-48-IEC SGR-48-IEC-2A4 48mm IEC 180M, 180L (2, 4, 6, 8 pole) 160mm
3 washers
SGR-55-IEC SGR-55-IEC-2A4 55mm IEC 200L (2, 4, 6, 8 pole); IEC 225S, 225M (2 pole) 168mm 3 lock washers
SGR-60-IEC SGR-60-IEC-2A4 60mm IEC 225S, 225M (4, 6, 8 pole) ; IEC 250M (2 pole) 168mm
3 spacers*
SGR-65-IEC SGR-65-IEC-2A4 65mm IEC 250M (4, 6, 8 pole); IEC 280M, 280S, 315S, 315M, 315L (2 pole) 185mm
Each kit includes 3 spacer lengths: 1/4”,
SGR-75-IEC SGR-75-IEC-2A4 75mm IEC 280S, 280M (4, 6, 8 pole); IEC 355M, 355L (2 pole) 193mm 1/2”, and 1” for NEMA kits and 7mm,
17mm, and 27mm for IEC kits.
SGR-80-IEC SGR-80-IEC-2A4 80mm IEC 315S, 315M, 315L (4, 6, 8 pole) 193mm
Kit includes (1) mounting plate, Kit includes (1) mounting plate,
(3) 1/4” spacers with screws and washers (3) 7mm spacers with screws and washers
(3) 1/2” spacers with screws and washers (3) 17mm spacers with screws and washers
SGR sold separately
(3) 1” spacers with screws and washers (3) 27mm spacers with screws and washers
AEGIS® iPROSL
Shaft Diameter 3.00” to 30.00”
High Current Bearing Protection for Large Motors over 500hp and Generators
(Medium Voltage-greater than 600 volts AC)
Outside Diameter: Slim Line Version-Shaft Diameter + 1.86”
Drawings available upon request
3 SVP tips, probe holder with two piece extension rod, and AEGIS®
SVP-KIT-3000
Grounding Simulator.
Fits Fluke VPS410 Voltage Probe. For other probe styles, see website.
SVP-TIP-3000
Installation: Pull off the hook clip from the voltage probe. Install the SVP tip over the voltage probe
tip until seated against the probe shoulder. Secure with plastic screw. Do not over tighten screw.
Used to improve the conductivity of the steel shaft surface. Apply to any VFD driven motor shaft
prior to installing the AEGIS® Bearing Protection Ring.
Used to install the AEGIS® Bearing Protection Ring without drilling and tapping into the motor end
bell.
Engineering Specification:
1. All motors operated on variable frequency drives shall be equipped with a maintenance
free, conductive micro fiber, shaft grounding ring with a minimum of two rows of circumfer-
ential micro fibers to discharge electrical shaft currents within the motor and/or its bearings.
2. Application Note: Motors up to 100HP shall be provided with a minimum of one shaft
grounding ring installed either on the drive end or non-drive end. Motors over 100HP shall
be provided with an insulated bearing on the non-drive end and a shaft grounding ring on
the drive end of the motor. Grounding rings shall be provided and installed by the motor
pump manufacturer or contractor and shall be installed in accordance with the manufac-
turer’s recommendations.
Detail Sheet
.375 ±.010
.1875 ±.010
Shaft Grounding Ring
(.695)
Motor
Max Shaft
End Shoulder Ø
Bracket Shaft Ø + .500"
Shaft
Shaft Shoulder
Slinger / Seal
Max Slinger/Seal OD
Or Casting Boss =
Shaft Ø + 1.0"
WARRANTY: Units are guaranteed for one year from date of purchase against defective materials and workmanship. Replacement will be made
except for defects caused by abnormal use or mishandling. All statements and technical information contained herein, or presented by the
manufacturer or his representative are rendered in good faith. User must assume responsibility to determine suitability of the product for
intended use. The manufacturer shall not be liable for any injury, loss or damage, direct or consequential arising out of the use, or attempt to use
the product.
The following patents apply: 8199453, 8169766, 7193836, 7136271, 7528513, 7339777, and other patents pending.