Zanasi Z1 Thermal Inkjet RemoteManager Handbuch
Zanasi Z1 Thermal Inkjet RemoteManager Handbuch
Zanasi Z1 Thermal Inkjet RemoteManager Handbuch
Manager
Instruction
Manual
Rel: 1.01
page 2
NOTE!
page 3
Table of Contents
General....................................................................... 5
Software design...................................................... 16
Functions ................................................................ 21
System settings...................................................... 42
Connections............................................................ 97
page 4
General
Information on this operating manual
This manual enables safe and effective use of the software.
The manual is a component of the software.
The manual must be available to the staff at all times near the PC
on which the software is installed.
The staff working with the software must have studied this manual
and be familiar with the content.
Compliance with all safety notes and instructions given in this
manual is a basic prerequisite for safe and efficient working.
Illustrations in this manual serve to provide a basic understanding
and may differ at times.
page 5
Explanation of symbols
Safety notes Safety notes are identified by symbols in this manual. The safety
notes are preceded by mnemonics signifying the severity of the
hazard.
It is imperative to observe the safety notes and to act with care to
avoid material damage.
CAUTION!
… points out a possibly dangerous situation which
may lead to material damage if not heeded.
page 6
Z1 Remote Manager
Limitation of liability
All the information and instructions in this manual were compiled
based on the current standards and regulations, state of the art
technology and our many years of know-how and experience.
The manufacturer is not liable for damages resulting from:
disregarding the manual
improper use
use of untrained staff
changes to the software
The obligations agreed upon in the supply agreement, the general
terms and conditions, the manufacturer’s delivery terms and the
statutory provisions applicable at the time of conclusion of the
contract are applicable.
We reserve the right to make technical changes to improve the
performance and in the course of on-going development.
Copyright
This manual is copyright protected and intended for internal use
only.
Making the manual available to third parties, any form of duplication
– fully or in part – as well as utilization and/or disclosure of
the content, except for internal use, is not permitted without the
written consent of the manufacturer.
Offenders will be liable for damages. Rights to further claims are
reserved.
Guarantee terms
The guarantee terms are specified in the General terms and
conditions of the manufacturer.
Customer service
Please refer to our customer service for technical information.
Our staff is furthermore always interested in new information and
experiences arising from the use of the product and which may be
valuable information for product improvement.
page 7
Z1 Remote Manager
Intended use
The software has been designed and implemented exclusively for
the intended use described herein.
The software serves to develop and administrate print images
which are transferred to the Z1 printing system.
Intended use also includes adherence to all the specifications in
this manual.
Any use beyond the intended use or any other use is regarded as
misuse.
Any claims arising from damages due to misuse will be rejected.
page 8
Z1 Remote Manager
Install software
The following steps imply that you have an installation file on USB-
stick.
Unser this link you’ll find always the latest Z1 Remote Manager
You’ll get the latest software update under the link, specified above
or the info button. The latest software includes also the latest
firmware versions.
page 9
Z1 Remote Manager
page 10
Z1 Remote Manager
page 11
Z1 Remote Manager
page 12
Z1 Remote Manager
NOTE!
The print systems are shown only if they are
registered previously.
page 13
Z1 Remote Manager
NOTE!
The print systems are shown only if they are
registered previously.
page 14
Z1 Remote Manager
–
Click the button in the title bar.
page 15
Z1 Remote Manager
Software design
Home page
The Z1 Remote Manager software is organized in two fields. On
the left is the navigation menu and on the right is the information
part of the software.
Navigation menu
Functions
Status messages are shown, print images and parameter are
managed and can be sent to the desired system.
Print image
Functions and settings for the print image.
Print images can be created and managed with the editor and can
send to one or more systems. Data base connections can be
configured and created automatically. Print images can load into
the system via the USB stick backup function.
Connections
The connections menu is used to configure connections to the print
systems.
Tools
The tools menu is used to make settings for the logging, user
management, the language of the software and a system-
independent terminal program.
End
To end the Z1 Remote Manager software.
page 16
Z1 Remote Manager
Information dialogue
Here you can also download the version for a software update.
page 17
Z1 Remote Manager
The illustration of the print systems in the tool bar is made with a
picture of the connected system, the name, a status LED and
connection information.
The system can be activated for editing with a click on the icon.
The frame around the icon is then wider than the other icons.
page 18
Z1 Remote Manager
Status LED
The status LED visualizes information about the operating
condition of the activated system.
NOTE!
The status signals can have different meanings,
depending on the system. For further information
have a look to the operating manual.
Alarm The system is in the „Alarm“ status and is not ready for
print.
NOTE!
System symbol blinks grey
If more than one PC access the print system,
the system flashes grey.
In this case is no configuration of the system over
Z1 Remote Manager possible.
Connection information
Depending on the type of connection the status displays two
information.
1. The name of the system, if a name has been assigned.
2. Different information, depending on the connection
Connection Meaning
page 19
Z1 Remote Manager
page 20
Z1 Remote Manager
Functions
Description of functions
The status of the connected systems can be shown.
The functions are used to manage print images and parameters
and to transfer these to available printers.
The connected printers are shown as symbols on the user
interface.
Submenu status
The status menu shows information of the system and whose
operating condition, which can call up.
The window is divided in different fields, depending on the print
system. These fields can be selected via the top tabs.
Status - Panel
The status – panel shows the status of the print system.
page 21
Z1 Remote Manager
The status list shows the actual error in form of an own status
LED, the print head, which concerns the error information and
a textual information of the error.
page 22
Z1 Remote Manager
Cartridges – panel
The cartridges - panel summarizes information for the head and
cartridges.
On the left side is a legend of the displayed information.
page 23
Z1 Remote Manager
page 24
Z1 Remote Manager
Configuration – panel
page 25
Z1 Remote Manager
System Shows the actual set system configuration Yes, see Change
configuration (Advanced, Pro) configuration
Max. Speed. Shows the maximum print speed of the Yes, see Change
system configuration
Date/Time Shows if the system supports date fields Yes, see Change
configuration
Variable fields Shows if the system supports variable fields Yes, see Change
configuration
Barcodes Shows barcode types, which are supported Yes, see Change
by the system configuration
USB Support Shows if the system supports the USB Yes, see Change
interface configuration
Interface Shows if the system supports the ethernet Yes, see Change
interface configuration
Maximum print Shows if the head coding is active in the Yes, see Change
length system configuration
IO Digital 24V Shows if the system supports the Digital IO Yes, see Change
interface configuration
page 26
Z1 Remote Manager
Inputs/Outputs – panel
The inputs/outputs – panel shows diverse graphical real-time signals
On the upper field there are control elements to control the display.
These are from left to right:
a.) Start/Stop of the signal preview
This allows a live preview of the signals
b.) Record signals
A file dialogue is shown after a click on this icon. Afterwards
the signals will be written as text in a file.
c.) Loupe 1:1
Renew the original size of the live preview.
d.) Loupe +
Zoom in in the live preview.
e.) Loupe –
Zoom out from the live preview again.
f.) Copy to Clipboard
Copies the current display of the live preview to the Windows
clipboard. This image can than paste into the image
processing software.
g.) Preview in s
The displayed value shows the maximum time interval, which
is shown in the line preview.
page 27
Z1 Remote Manager
All signals, which are provided from the system, are listed on the
left side. These signals act as legend of the live preview. The
display of the legend happen by:
a.) Signal name
b.) LED
If the signal is active (High), the LED will be light green. If the
signal is inactive (Low), the LED will be dark green.
c.) Selection-Checkbox
Via the checkbox can determine whether this signal should be
displayed in the live preview. It’s possible to display up to 10
different signals.
d.) Signal color
The signal color for all signals, which are shown in the live
preview, is assigned automatically.
page 28
Z1 Remote Manager
Submenu Printing
Print start
To select a print image for print on a specific control system, first
select a control system. Click the “Print” button in the “Functions”
selection field. Select the print image from the list field, bottom
right and select one or more print heads, which should receive the
print image. The selected print heads are marked blue.
To start printing, click the “Start print” button.
If there are variable fields in the print image, they will query now.
If a data base connection is used, a specified data set can be
selected with the search function.
Print stop
Press the „Stop print“ button to stop printing.
page 29
Z1 Remote Manager
page 30
Z1 Remote Manager
page 31
Z1 Remote Manager
Submenu Settings
Tab Print parameter
The print parameters depend on the connected type of printer.
NOTE!
Consult the printer manual to set the print
parameter.
page 32
Z1 Remote Manager
Print
Delay
The parameter print delay defines the path distance in mm
between the light barrier trigger by the product and start of printing.
By setting such a print delay, the position of the print image on the
product can be changed. The print delay can be specified for each
print head.
Adjustable values: 0 to 999 mm.
1. Press tab Printhead 1 or Printhead 2 (depends on the
number of the activated print heads) and select the desired
print head.
2. Click on the tab Print parameter.
3. To set the delay,
– Press arrow keys and set the required delay value.
NOTE!
The print start delay must not be greater than the
distance between 2 products. If a print start is
triggered before the last print is finished, it will be
ignored.
Intensity
Print image contrast. If necessary, this parameter may have to be
changed to optimize the print image to the product surface. Higher
intensity means increased density and slower drying of the ink.
1. Press tab Printhead 1 or Printhead 2 (depends on the
number of the activated print heads) and select the desired
print head.
2. Click on the tab Print parameter.
3. To set the resolution,
– Press arrow keys and set the required delay value.
Zoom
This parameter enables an increase or decrease of the number of
pixels. This renders the print image wider or narrower.
1. Press tab Printhead 1 or Printhead 2 (depends on the
number of the activated print heads) and select the desired
print head.
2. Click on the tab Print parameter.
3. To set the zoom,
– Press arrow keys and set the required delay value.
page 33
Z1 Remote Manager
NOTE!
When printing barcodes, ensure that widening or
narrowing occurs only in the correct ratio. Note the
optimal print intensity of 300 dpi. Observe the
following table!
1 100, 200
6 50, 66, 83, 100, 116, 133, 150, 166, 183, ...
Print direction
The Print direction parameter specifies the direction in which the
product moves on the conveyor belt as viewed from the Printhead
side.
1. Press tab Printhead 1 or Printhead 2 (depends on the
number of the activated print heads) and select the desired
print head.
2. Click on the tab Print parameter.
3. Set the direction of the conveyor belt in the dropdown menu
print direction.
Nozzle row
Each ink cartridge has two nozzle rows (A and B). One nozzle row
has 150 nozzles.
The nozzles in row A print the uneven numbers 1, 3, 5, 7 …
The nozzles in nozzle row B print the even numbers 2, 4, 6, 8…
Per nozzle row A ~ B, 300dpi are printed vertical.
In this mode, the nozzles are uniformly stressed and the speed
setting is not as critical as with A + B.
If, for instance, using A ~ B, every second print image is of poor
quality, nozzle row A or nozzle row B can be activated.
Both nozzle rows print simultaneously with the setting A+B. The
vertical resolution is 600 dpi. The print image is dark equal. The
speed must be exactly right, because this will cause a shadow or
blurred print when the nozzle rows are not print about each other
correctly.
page 34
Z1 Remote Manager
NOTE!
With setting A + B, the print speed must be accurately
set, to produce a good print result. Otherwise the print
image is blurred (shadow print).
Upside down
The setting Upside Down causes the print image to be printed
upside down.
To select upside down,
1. Press tab Printhead 1 or Printhead 2 (depends on the
number of the activated print heads) and select the desired
print head.
2. Click on the tab Print parameter.
3. Activate upside down in the dropdown-menu.
Encoder resolution
The encoder resolution is a pilot tool to identify the correct encoder
resolution in the print parameter menu.
The encoder resolution is called up with the additional button.
page 35
Z1 Remote Manager
page 36
Z1 Remote Manager
Repeat distance /
Print repeat number
To print several print images on one product, the number of print
images and the distance between them must be specified.
The distance between print images is measured from print start to
print start.
If you select „5“ the print image will be printed 6 times. 1 print plus
5 repeats.
998 prints 999 print images.
Endless printing can be activated with print repeat of „999“.
page 37
Z1 Remote Manager
NOTE!
These parameter is only visible if one input is set to
„print direction“.
page 38
Z1 Remote Manager
NOTA!
The head voltage and fire time will be set
automatically, depends on the ink type.
The values should be change carefully and after
instruction, otherwise the cartridge can be
damaged.
page 39
Z1 Remote Manager
page 40
Z1 Remote Manager
Tab Calibration
If a twin Printhead or a Printhead with several modules (Triple,
Quad, ...) is connected to the controller, the offset between the two
print heads must be adjusted, if necessary. If single print heads are
connected, a calibration isn’t necessary.
NOTE!
Before the print heads are calibrated, the print speed
or the rotary encoder setting must be correct.
The offset between the two print heads is compensated for by the
input of correction factors.
A negative value means that the print image of this cartridge
moves to the left side and reverse.
page 41
Z1 Remote Manager
System settings
WARNING!
These settings should change from an expert only!
The function of the system can be disrupted by an
incorrect setting.
NOTE!
Every adjustment will be send immediately to the
connected printer.
page 42
Z1 Remote Manager
Save to file
The print head- and system settings can saved on a PC. These
can be used for a later system recovery or be linked to a print
image to change system settings depends on the print image.
1. Press the Save button to save the settings.
2. Enter the file name in the dialog field.
3. Concluding click on the Save button
The settings are saved below your selected file name
The saved settings can be linked with a print image. See Editor
“connect with set of parameters“.
Load defaults
1. Press Standard value to reset all settings in the delivery
status. Head configuration, ink type and interface values won’t
be changed.
2. Confirm the dialog field with OK
To enable the printer to correctly interpret and display the texts and
graphics used in the print images, the respective fonts and logos
must be transferred to the printer’s memory.
NOTE!
Selection of the fonts and logos depends on the
connected printer.
Standard the required fonts and logos for printing will be sent to the
system automatically when a print image with fonts and logos will
be create in the Z1 Remote Manager editor.
There is the possibility to send the files manually.
page 43
Z1 Remote Manager
Send fonts 1. To send a font to the selected printer, select the “System
settings” button in the “Functions” register.
page 44
Z1 Remote Manager
Send logos 1. Select in the Function menu the System settings tab to send
a logo to the selected system manually.
page 45
Z1 Remote Manager
Shift code
Shift codes are short strings (1-4 signs), which are active,
dependent on the actually time of day, and can integrate in print
layouts.
The shift code can be print as date field with the placeholder „t“ per
sign in the layout.
To activate the shift code:
1. Activate the corresponding shift code line by clicking the
checkbox to the left.
2. Following set the start time of the shift.
(The end time is set by the software automatically)
3. Now type below code the desired marking.
3. Closing click send.
The configured shift codes will be send to the print system
page 46
Z1 Remote Manager
page 47
Z1 Remote Manager
page 48
Z1 Remote Manager
Barcode
correction in This option provides the opportunity to improve the readability of a
pixel barcode element by widening or narrowing. If, for example, the
runs heavily on a coarse fibrillate surface, the readability can be
restored by a pixel-wise reduction of the line width.
To make a barcode correction,
1. Select the Device Setup in the submenu System.
2. Press arrow keys and set the required correction
System configuration
Device name
Click on the icon in the column Device Name: to change the
system name. It opens a dialog where the new name will be asked.
Enter the new name in the text field and confirm your input with
OK.
The system name will be changed in Z1 Remote Manager.
Configuration code
It’s possible to change the system configuration, i.e. the setting if the
controller is a Advanced or Pro system.
This is possible via a configuration code. You’ll get the
configuration code from your local distributor with costs.
1. Please go to:
Settings System
Configuration code
2. Click on the right icon in the line „configuration code“
page 49
Z1 Remote Manager
Firmware Update
WARNING!
Data loss effected by update!
It can happen a data loss with an update of the
system software.
Therefore
Perform a backup before every update (see:
"Advanced settings").
page 50
Z1 Remote Manager
Online Update
NOTE!
The online update for a print system is only possible
with the latest firmware.
CAUTION!
Don’t disconnect the power supply voltage of the
system and don’t switch it off.
page 51
Z1 Remote Manager
Change IP-address
Enter the new IP address in the entry mask and confirm the input
with OK.
Following the IP address of the print system will be
changed. If the system was already connected with Z1
Remote Manager by TCP/IP, the IP address will also be
changed there,
If the system wasn’t connected by TCP/IP, you will be
asked if the system should be added by TCP/IP
Netmask
Change the netmask of the system with this function.
Gateway
Change the gateway address of the system with this function.
CAUTION!
Consult the system administrator for network
settings. Network damages can be caused by
incorrect settings.
Stitch device
Connect several Z1 Stitch with this function.
To connect the systems to one Stitch system, please proceed as
follows:
page 52
Z1 Remote Manager
NOTE!
Only one PC can have access to the Stitch system.
The systems can’t address individually, because
they exchange data among themselves.
NOTE!
Please note that all systems are registered with
different IP address.
page 53
Z1 Remote Manager
4. Both heads restart and it will displayed the first head with the
second in the system only.
page 54
Z1 Remote Manager
NOTE!
First the system should set up that the print is okay
to 99%. Then the last millimeter should be
optimized with the calibration function.
page 55
Z1 Remote Manager
page 56
Z1 Remote Manager
page 57
Z1 Remote Manager
Terminal
A direct communication with the coding systems can be done by
the terminal. The commands are sent to the system by an existing
connection. The answer of the system is shown in the lower
window.
CAUTION!
An incorrect use of the terminal can result data loss
or faults of the system.
CAUTION!
There is no checking of the correct notation of the
command by Z1 Remote Manager.
page 58
Z1 Remote Manager
i.e.
<ESC>*<CR> consists of 3 bytes: decimal. 27, 42, 13
Input of Hexcodes
It can also use hexcodes in following syntax:
i.e.:
<0x1B>*<0x0D>
page 59
Z1 Remote Manager
Send interval
If one or more commands should send continuously, it can start with
Send command
1. Type the desired command in the command window.
2. Click on Send
… The commands will be send to the coding
NOTE!
Lines, which begins with „//“ are comments and are
not send.
2. Click on Send
… The commands will be send to the coding
Load commands
1. To load already saved commands click on Open
2. Browse by the file dialog to the desired file.
page 60
Z1 Remote Manager
NOTE!
The file extension for template files is .ast
3. Open loads the data content of the file in the upper terminal
window.
4. Click on Send to send the commands to the coding system.
Save commands
1. Click on Save to save the currently shown commands in the
upper terminal window.
2. Select the file dialog, a name and a storage location and
confirm with Save.
page 61
Z1 Remote Manager
page 62
Z1 Remote Manager
Create new print image Opens a new label after the selection of the label type.
Open existing print image Opens an existing print image. A preview is displayed.
Save print image Saves the current print image. Requests a name if none
exists.
Save print image below… Saves the actual print image below the specified name.
page 63
Z1 Remote Manager
Text field Creates a text field to add static text to the print image.
Variables field Creates a variables field to add a variable to the print image
Date field Creates a date field to add a date to the print image.
Counter field Creates a counter field to add a counter to the print image.
Barcode field Creates a barcode field to add a barcode to the print image.
Ink consumption calculator Determines the number of prints of the desired label, which
can be print with a full cartridge.
page 64
Z1 Remote Manager
Enter text
page 65
Z1 Remote Manager
5. To position the text field in the print image, click on the text
field and move to required position by pressing and holding
the left mouse button.
page 66
Z1 Remote Manager
6. To create a graphic text field, click on the button True Type. All
fonts types of Windows available now.
7. Height and width are adjustable with the red handle.
page 67
Z1 Remote Manager
Date and time are embedded in the print image as a date field.
NOTE!
The function date field is not available for each
system configurations.
q Weekday 4
rr Calendar week 28
s Hour as string k
page 68
Z1 Remote Manager
Variable Meaning
a Day, tens
b Day, units
c Month, tens
d Month, ones
e Year, thousands
f Year, hundreds
g Year, tens
h Year, ones
i Hour, tens
j Hour, ones
k Minute, tens
l Minute, ones
m Second, tens
n Second, ones
q Weekday
rr Calendar week
page 69
Z1 Remote Manager
Further
Variable Meaning
B Day as character
(1-9=A, 10-19=B, 20-29=C, ...)
D Month as character
(1=A, 2=B, …, 12=M)
Q Weekday as character
(1=A, 2=B, …, 7=G)
Forward dating, for instance to print a best before date (BBD), can
be defined by the offset parameters year, month and day.
.
page 70
Z1 Remote Manager
7. Select the date field and, by holding down the left mouse
button, position as required inside the print image.
page 71
Z1 Remote Manager
NOTE!
The function is not available for each system
configurations.
Example 1:
Starting value: 01, end value: 10, step size: 2, repeats: 3
Print: 01, 01, 01, 03, 03, 03, 05, 05, 05....
NOTE!
All zeroes in front of a number are also printed.
The leading zeroes can be deselect by the checkbox.
Example 2:
Starting value: 10, end value: 1, step size 1, repeats: 0
Print: 10, 9, 8, 7....1, 10, 9, 8, 7....
Insert the counter field
page 72
Z1 Remote Manager
NOTE!
Only printer, no TrueType fonts
page 73
Z1 Remote Manager
EAN 128 Numerical commercial logistics code. Variable fields for date, counter -
and scale as options.
Code 128 Full ASCII barcode; medical-pharmaceutical technology. -
Data Matrix A 2D code for the electronics industry and pharmaceutical sector. -
EAN Data Matrix A 2D code for the electronics industry and pharmaceutical sector. -
QR Code A 2D-Code
page 74
Z1 Remote Manager
1. To create a barcode,
page 75
Z1 Remote Manager
page 76
Z1 Remote Manager
NOTE!
The function is not available for all system
configurations.
Variable fields are used if a print image contains data (e.g. batch
numbers) that change frequently. This can be automated, shortly
before the print image is released for printing.
The variable field is queried each time before a print image is
called. A dialog window appears, requesting the variable value to
be entered. A new text may then be entered, or the old text
retained. It is possible to enter several variable fields in a text.
Info text is available as an additional function. This info text (e.g.
batch numbers) is displayed during subsequent print call-up
requests, to prevent incorrect entries or, in the case of several
variable fields in a print image, confusion.
page 77
Z1 Remote Manager
NOTE!
Only printer fonts, no TrueType fonts.
Insert a logo
page 78
Z1 Remote Manager
5. Click on the logo and position in the print image whilst holding
down the left mouse button.
6. Double-click the logo to edit it.
The edit program opens.
page 79
Z1 Remote Manager
NOTE!
The graphic data with adjustable logo size will be
saved with the right format in the print image file.
The logo files of a print image with a fixed logo size
will be transfer to the system.
page 80
Z1 Remote Manager
NOTE!
The function action field is not available for all
system configurations.
NOTE!
The ID number must always be bigger than 0.
Variable Function
z counter
Z* Counter as character
page 81
Z1 Remote Manager
Example: 1:
A print image contains a text field and a barcode. Both fields are
allocated the same ID number in order to receive the same data
with print call.
1. To create the text field,
page 82
Z1 Remote Manager
page 83
Z1 Remote Manager
The text field and the barcode are now two action fields. The data
in the text field are also written to the plain text line of the barcode.
The Article no. and the barcode receive the same data.
page 84
Z1 Remote Manager
Example 2:
page 85
Z1 Remote Manager
page 86
Z1 Remote Manager
page 87
Z1 Remote Manager
Reference fields
Variable fields, date fields and counter fields can be so designed
that they are available in the label layout, but will not print.
It makes sense if you want to revert to information, like a date in a
barcode, but this date would not print.
page 88
Z1 Remote Manager
page 89
Z1 Remote Manager
NOTE!
The number of prints per cartridge is an
approximate value. The exact value can be seen
after an optimal print image selection.
page 90
Z1 Remote Manager
Database
Open file
page 91
Z1 Remote Manager
Open
ODBC
Use the “Search” button to find a specific line in the database. The
search always references the line entered in “Settings”.
The Settings tab takes you to the menu item for database settings.
.
page 92
Z1 Remote Manager
Settings
The General field determines the column used for the search
function.
page 93
Z1 Remote Manager
page 94
Z1 Remote Manager
page 95
Z1 Remote Manager
4. Select a database field for the label name in the following dialog
and confirm your choice with OK
5. Wait until the label is created and the progress window close
automatically.
NOTE!
The labels will be saved in a subfolder in the standard Z1
Remote Manager label index.
The name of the subfolder is identic with the name of the
origin label.
page 96
Z1 Remote Manager
Connections
Add system
1. Click on the Add system button in the Connections register.
NOTE!
Manual addition of connections is only required for
Ethernet connections. USB connections are
detected and shown automatically. Serial
connections must be searched for manually using
Search at Com Ports
page 97
Z1 Remote Manager
NOTE!
The connection persists until the finish of Z1
Remote Manager. The connection is reject by
closing Z1 Remote Manager.
If you want to retain the connection please use the
Save connection function.
Save connection
1. Select a system in the system tool bar.
2. Click in the tab Connections on the Save connection.
3. Enter a name for the system and confirm this with OK.
The selected connection will be saved and is after a Z1
Remote Manager restart available.
NOTE!
The saving is not for USB-stick connections of the
Z1 available.
page 98
Z1 Remote Manager
Delete connection
1. Select the system in the system tool bar.
2. Select in the Connection tab the Delete connection button.
page 99
Z1 Remote Manager
Update firmware
If there was a transmission error during the firmware update and
the systems can’t identified by Z1 Remote Manager, the firmware
update dialog can manually select with the Update firmware
menu.
2. Read the warning information and confirm the dialog with OK.
3. Select the connected system below printer type.
4. Select the port where the system is connected.
Follow the commands for Load firmware
Stop server 1. Click on the Stop server button in the Connection tab to
stop the Z1 Remote Manager server.
After the shutdown of the Z1 Remote Manager server the
gears don’t rotate in the upper bar of Z1 Remote Manager
NOTE!
The Stop server button is only selectable if the
server runs, i.e. if the gears rotate in the status bar.
page 100
Z1 Remote Manager
Start server
NOTE!
The Start server button is only selectable if the
server doesn’t run, i.e. the gears don’t rotate in the
status bar.
Interface logging
page 101
Z1 Remote Manager
Start
1. To start the real time logging,
– click on the Start logging button.
The generated system messages of Z1 Remote Manager
are shown in the upper window.
Stop
2. To deactivate the logging,
– click on the Stop logging button.
Delete screen
3. To delete the logo screen,
– click on the Delete button.
Save
1. To save the system messages of Z1 Remote
Manager in a file automatically,
– click on the Start logging button.
2. Select a folder and a file name for the log file and confirm with
Save.
NOTE!
The log file is saved in the folder „Z1 Remote
Manager/Log/“ standard.
The standard extension for log files is „.txt“
page 102
Z1 Remote Manager
NOTE!
All system-depending functions, also without a
connection to the system, can be realized with the
assistance of the virtual system function.
page 103
Z1 Remote Manager
Tools
General settings
Set up language
1. To change the actual user language, click on General
settings in the selection register Tools.
2. Select the desired language by mouse click in the list field
„user languages“. The changes come into effect partly after
restart.
NOTE!
The changes will be assumed after the Z1 Remote
Manager restart.
Configure Z1
Automatic firmware update
Remote Manager
The actually firmware version of the added control system
will be checked every time if this function is activated. The
user will be informed by a dialog if the firmware version isn’t
actual. The user is guided to the update process by request.
page 104
Z1 Remote Manager
Distributor features
This function is only available for official Zanasi distributors and
must be considered separately.
Stitch function
The option connects several Z1 Stitch to one stitch system.
page 105
Z1 Remote Manager
Query last value The counter start value will be queried from
the user. The current counter value is
displayed as default line.
page 106
Z1 Remote Manager
Terminale
The terminal in the menu Tools can contact any other system
(scanner, camera…) and test the communication.
For this a connection is necessary. The connection can be
Ethernet (TCP/IP), USB, or EIA232.
NOTE!
NOTE!
page 107
Z1 Remote Manager
3. Select the baud rate, data bits, parity and the number of stop
bits.
4. Click on Connect.
Connection status
Besides the Connect button is a LED, which displays the status of
the connection with 3 colors.
Color Meaning
Grey No connection
CAUTION!
The incorrect use of the terminal can cause data
loss and failures of the print system.
CAUTION!
Z1 Remote Manager didn’t check the correct
spelling of the commands.
Send interval
If one or more commands should send continuously, it can start
Send command
1. Type the desired command in the command window.
2. Click on Send
… The commands will be send to the coding
page 108
Z1 Remote Manager
NOTE!
The terminal allows the sending of ascii signs. This
must be specified in form <0x01> (for
<SOH>) in hexadecimal spelling.
NOTE!
Lines, which begins with „//“ are comments and are
not send.
2. Click on Send
… The commands will be send to the coding
Load commands
1. To load already saved commands click on Open
2. Browse by the file dialog to the desired file.
NOTE!
The file extension for template files is .ast
3. Open loads the data content of the file in the upper terminal
window.
4. Click on Send to send the commands to the coding system.
Save commands
1. Click on Save to save the currently shown commands in the
upper terminal window.
2. Select the file dialog, a name and a storage location and
confirm with Save.
page 109
Z1 Remote Manager
NOTE!
Drive letter of the USB-stick can be look up in the
Windows file explorer or rather below desktop
page 110
Z1 Remote Manager
NOTE!
Files and folders, which exist on the USB-stick
already and collide with the actual firmware update,
will be moved to the folder „MOP_FW_Backup”.
page 111
Z1 Remote Manager
User Management
Overview
The Z1 Remote Manager user management facilities allows for
access to dedicated features of Z1 Remote Manager based on
user name and password identifiers. In this regard, it follows the
standard approach, which most users are familiar with, from i.e.
the Windows operating system and many more.
However, because there are many different requirements on how
to manage user credentials in the field of industrial applications,
Z1 Remote Manager comes with three different flavors of user
management. The list below provides a short overview of those:
Type Characteristics
page 112
Z1 Remote Manager
page 113
Z1 Remote Manager
page 114
Z1 Remote Manager
page 115
Z1 Remote Manager
6. Now, type in the passwords for the admin user and super user.
You can leave the entries for the standard user blank. You will
note, that you need to type each of the passwords twice.
7. Tip the automatic login checkbox inside the standard user
group box.
8. Click the finish button. Z1 Remote Manager will restart.
page 116
Z1 Remote Manager
Log out
1. Press the small black arrow near the login button.
2. On the menu that will appear then, select logout.
3. You will be asked if you really want to log out. Confirm by
pressing the Ok button.
page 117
Z1 Remote Manager
Change a Password
page 118
Z1 Remote Manager
NOTE:
It is not possible to add or to remove any credentials from the
admin access level.
page 119
Z1 Remote Manager
Appendix
List of available credentials
Print Start / Stop Access to the “Print” button of the “functions” menu
Basic Device Settings Access to the “Print Parameters” settings strip in the
“settings” form of the “functions” menu.
Change Device Type Access to the “Device Setup” slider in the “settings”
form of the “functions” menu.
Change Ink Settings Access to the “Spitting and Warming” slider in the
“settings” form of the “functions” menu.
Change Head Setup Access to the “Head Setup” slider in the “settings”
forms of the “functions” menu.
Labels from DB Access to the “Create labels from DB” button in the
“Layout” menu.
Start / Stop server Access the buttons “Start server” and “Stop server”
on the “Connections” menu.
page 120
Z1 Remote Manager
page 121
Z1 Remote Manager
Event Logging
If the user management is active, all user inputs are listed in the
event logging.
Font Creator
The font creator is used to generate Zanasi print fonts from
Windows TrueType fonts. The delivered standard character set of
the print system can add with new sizes and fonts, like i.e. Cyrillic.
Procedure:
page 122
Z1 Remote Manager
1. Select the font name and height in mm. It can also select an
international character set.
2. Click on the button Next.
page 123
Z1 Remote Manager
Single font
With the option single font you have the possibility to edit the
character set with Paint.
Therefore click the button Edit.
page 124
Z1 Remote Manager
Font package
Specify a name for a new font package by enter a name code for
the first segment. A letter is therefore enough. The second
segment is provide with the height information automatically by the
creation. Following there is the possibility for an addition like, i.e. B
for bold.
NOTE!
The fonts can also save in other folder, but are
available for the print image creation.
page 125
Z1 Remote Manager
NOTE!
The new created fonts can used for the print image
creation now.
NOTE!
It isn’t necessary to copy the new fonts in the print
system manually. The new fonts will send
automatically with the print start of Z1 Remote
Manager or by sending the print image in the print
system.
page 126
Z1 Remote Manager
page 127
Z1 Remote Manager
Arrow keys
Description
page 128
Z1 Remote Manager
System functions
Function
Information of the
operation status of the
corresponding system
page 129
Z1 Remote Manager
Toogle functions
Symbol Function Description
NOTE!
If the on-screen keyboard is faded in, the status displays
are not visible.
page 130
Z1 Remote Manager
System functions
Load print image
The print image in print memory is printed on the
product surface by the print heads after each impulse
from the light barrier.
To load a print image into the print memory,
page 131
Z1 Remote Manager
The print image is loaded into print memory and displayed in the
main menu.
For systems with multiple heads, a print image can start on all
heads:
page 132
Z1 Remote Manager
page 133
Z1 Remote Manager
Menu Settings
Basic parameterization must be performed in the Settings menu
before the print system is able to print.
The Settings menu has the following submenus:
Submenu Description
page 134
Z1 Remote Manager
page 135
Z1 Remote Manager
NOTE!
The print start delay must not be greater than the
distance between 2 products. If a print start is
triggered before the last print is finished, it will be
ignored.
page 136
Z1 Remote Manager
NOTE!
When printing barcodes, ensure that widening or
narrowing occurs only in the correct ratio. Note the
optimal print intensity of 300 dpi. Observe the
following table!
page 137
Z1 Remote Manager
1 100, 200
6 50, 66, 83, 100, 116, 133, 150, 166, 183, ...
Zoom 10 900 %
To enter the print speed, the print intensity and the print width /
zoom,
– Press arrow keys and set the required value.
The values are accepted as soon as the arrow keys are
released.
or:
– Press and highlight the input field.
– Enter the values via the on-screen keyboard and confirm
with the Enter key on the keyboard.
The figures originally displayed in red are displayed in black
after confirmation with the Enter key.
Print direction
The Print direction parameter specifies the direction in which the
product moves on the conveyor belt as viewed from the Printhead
side.
1. Press tab Printhead 1 or Printhead 2 (depends on the
number of the activated print heads) and select the desired
print head.
2. Specify the direction of the conveyor in the dropdown menu
page 138
Z1 Remote Manager
Nozzle row
Each ink cartridge has two nozzle rows (A and B). One nozzle row
has 150 nozzles.
The nozzles in row A print the uneven numbers 1, 3, 5, 7 …
The nozzles in nozzle row B print the even numbers 2, 4, 6, 8…
Per nozzle row A ~ B, 300dpi are printed vertical.
In this mode, the nozzles are uniformly stressed and the speed
setting is not as critical as with A + B.
If, for instance, using A ~ B, every second print image is of poor
quality, nozzle row A or nozzle row B can be activated.
Both nozzle rows print simultaneously with the setting A+B. The
vertical resolution is 600 dpi. The print image is dark equal. The
speed must be exactly right, because this will cause a shadow or
blurred print when the nozzle rows are not print about each other
correctly.
Activate the nozzle rows as follows:
NOTE!
With setting A + B, the print speed must be accurately
set, to produce a good print result. Otherwise the print
image is blurred.
page 139
Z1 Remote Manager
page 140
Z1 Remote Manager
page 141
Z1 Remote Manager
page 142
Z1 Remote Manager
NOTE!
Please read the operator manual of the print
system to set the print parameter.
page 143
Z1 Remote Manager
page 144
Z1 Remote Manager
Tab Calibration
If a twin Printhead is connected to the controller, the offset between
the two print heads must be adjusted, if necessary. If single print
heads are connected, a calibration isn’t necessary.
NOTE!
Before the print heads are calibrated, the print speed
or the rotary encoder setting must be correct.
The offset between the two print heads is compensated for by the
input of correction factors.
A negative value means that the print image of this cartridge
moves to the left side and reverse.
page 145
Z1 Remote Manager
page 146
Z1 Remote Manager
page 147
Z1 Remote Manager
Submenu System
Following settings can be made in the submenu System:
Device Setup
Input Output Configuration
Serial interface EIA232
WARNING!
These settings should change from an expert only!
The function of the system can be disrupted by an
incorrect setting.
NOTE!
Every adjustment will be send immediately to the
connected printer.
page 148
Z1 Remote Manager
Set default
1. Press Set default to reset all settings in the delivery status.
Head configuration, ink type and interface values won’t be
changed.
2. Confirm the dialog field with OK.
.
A dialog for the text selection opens.
2. Select the desired text over the drop down menu and
confirm with OK.
The settings of the set of parameters opens.
page 149
Z1 Remote Manager
3. Confirm with OK .
Language
Language lists all the installed user languages, in which the user
interface of the print system can be displayed.
To select a user language,
1. Select the tab Device Setup in the submenu System.
2. Set the desired language in the dropdown menu.
page 150
Z1 Remote Manager
page 151
Z1 Remote Manager
Device name
Change the device name of the system.
Configuration code
It’s possible to change the system configuration, i.e. the setting if the
controller is a Advanced or Pro system.
Update firmware
WARNING!
Data loss effected by update!
It can happen a data loss with an update of the
system software.
Therefore
Perform a backup before every update (see:
"Advanced settings").
IP Address
Change the IP address of the system with this function.
Netmask
Change the netmask of the system with this function.
Gateway
Change the Gateway-address of the system with this function.
page 152
Z1 Remote Manager
CAUTION!
Consult the system administrator for network
settings. Network damages can be caused by
incorrect settings.
page 153
Z1 Remote Manager
page 154
Z1 Remote Manager
Submenu Logging
Start
1. To start the real time logging,
– click on the Start/Stop button.
The generated system messages of Z1 Remote Manager
are shown in the upper window.
page 155
Z1 Remote Manager
Delete screen
3. To delete the logo screen,
– click on the Clear button.
Menu Status
The status menu shows information of the system and whose
operating condition, which can call up.
The window is divided in different fields.
page 156
Z1 Remote Manager
Function
Create new print image Empties the editing area to create a new
print image.
Save print image as… Saves the current print image under another
name.
page 157
Z1 Remote Manager
Symbol
page 158
Z1 Remote Manager
page 159
Z1 Remote Manager
page 160
Z1 Remote Manager
2. Select the Format drop down menu and select the Date/Time
format with the scroll bar or accept the default setting.
3. Set a best before date, if required. To do this, select the
year/month/day figures using the arrow keys.
4. If necessary, adjust the font format.
5. Confirm with OK.
The date field is inserted in the print image.
6. To position the date field in the print image,
– Position your cursor on the date field and drag it across the
screen to the required position.
or:
– Select the date field and highlight.
– Select the arrow keys and move the date field to the
required position.
A date field inserted in the print image may be edited and changed
at any time:
1. Double click on the date field.
The editing window opens.
Insert a barcode
A barcode is machine-readable “text” comprising parallel lines of
various widths, and gaps.
The information content in the barcode can also be displayed in
writing legible to people in a plain text row directly below the
barcode, If the barcode cannot be read, the information can be
read manually.
The following barcode types are available:
page 161
Z1 Remote Manager
EAN 128 Numerical commercial logistics code. Variable fields for date, counter -
and scale as options.
Data Matrix A 2D code for the electronics industry and pharmaceutical sector. -
EAN Data Matrix A 2D code for the commercial and pharmaceutical sector. -
To create a barcode,
1. Select the button in the Editor menu.
The selection window opens.
2. Select the Type drop down menu and select the barcode
type and confirm with OK.
The editing window opens.
page 162
Z1 Remote Manager
page 163
Z1 Remote Manager
Example 1:
Starting value: 01, end value: 10, step size: 2, repeats: 3
Print: 01, 01, 01, 03, 03, 03, 05, 05, 05....
Example 2:
Starting value: 10, end value: 1, step size 1, repeats: 0
Print: 10, 9, 8, 7....1, 10, 9, 8, 7....
page 164
Z1 Remote Manager
2. Select the Start value input field and enter the start value
via the screen keyboard.
3. Select the End value input field and enter the end value via
the screen keyboard.
4. Select the Step width input field and enter the step size via
the screen keyboard.
5. Select the Repeats input field and enter the repeat rate via
the screen keyboard.
6. To print zeros preceding a number as well, select the
checkbox and tick.
7. If necessary, adjust the font format.
8. Confirm with OK.
The counter field is inserted in the print image.
9. To position the counter field in the print image,
– Position your cursor on the counter field and drag it
across the screen to the required position.
page 165
Z1 Remote Manager
or:
– Select the counter field and highlight.
– Select the arrow keys and move the counter field to the
required position.
A counter field inserted in the print image may be edited and
changed at any time:
1. Double click on the counter field.
The editing window opens.
2. Select Default line input field and enter the variable text via
the screen keyboard.
3. Select the Info text input field and enter the info text via the
screen keyboard.
4. If necessary, adjust the font format.
5. Confirm with OK.
The variable field is inserted in the print image.
page 166
Z1 Remote Manager
Insert a graphic
Graphics can be inserted in a print image as bitmap files.
To insert a graphic in a print image,
1. Select the button in the Editor menu.
The Open file window opens.
page 167
Z1 Remote Manager
1. Open the desired print image in the editor and touch the
button.
A dialog for text selection opens.
2. Select the desired parameter set in the drop down menu and
confirm with OK .
page 168
Z1 Remote Manager
NOTE!
If the parameter values will be changed during
printing, this have no effects for the saved parameter
set of the print image.
Data base
To use the data base function, the data base must be opened.
page 169
Z1 Remote Manager
To open a specific row from the data base press the button
by the print start. The information will be insert in the label
automatically.
2. Select the Name drop down menu and select the font type
using the scroll bar.
3. Use the arrow keys to select the font width.
4. Confirm with OK.
button.
The file dialog opens.
page 170
Z1 Remote Manager
3. Enter the file name in the File name field via the on-screen
keyboard or select the file to be overwritten in the Save file
field.
NOTE!
The file automatically receives a .00I extension.
2. In In the Open file field, press the print image and highlight.
The print image appears in the Preview window.
3. Confirm with OK.
The print image is opened.
page 171
Z1 Remote Manager
Menu Setup
The menu Setup includes following submenus:
System
Interface
Database
Directories
Submenu System
To display the System submenu,
page 172
Z1 Remote Manager
CAUTION!
Malfunctions due to incorrect Windows system
settings!
The Windows system may malfunction due to
incorrect settings in the print system.
Therefore:
– Settings may only be applied by specialized staff.
page 173
Z1 Remote Manager
User language
The User language field lists all the installed user languages.
To select a user language, go to the menu Setup, to the submenu
System
1. Select a language.
The user interface is immediately shown in the selected
user language.
mostrata nella lingua utente selezionata.
page 174
Z1 Remote Manager
Query last value The counter start value will be queried from
the user. The current counter value is
displayed as default line.
page 175
Z1 Remote Manager
Keyboard layout
The field keyboard layout list all installed keyboard layouts.
To select a keyboard layout,
1. Click in the menu Settings on the submenu System.
2. Select the desired layout.
The keyboard is shown in the desired keyboard layout
directly.
User Management
To activate the user management, please proceed as follows:
1. Click in the main menu on the button Settings and the
submenu System.
The submenu System opens.
page 176
Z1 Remote Manager
Submenu Interface
If the print system is connected to and controlled by a machine
control point or PC via an external interface, such interface must
be set up.
The following interfaces are available for selection:
Ethernet interface RJ45
Serial interface RS232
Ethernet interface
NOTE!
The selected port address must correspond to the port
address of the Windows interface. By default it is COM1.
page 177
Z1 Remote Manager
NOTE!
The selected baud rate must correspond to the baud
rate of the connected PC!
page 178
Z1 Remote Manager
page 179
Z1 Remote Manager
page 180
Z1 Remote Manager
Search
Settings
Calculate MHD offers the possibility for to have an automated
offset function for the date function which is calculated from
defined field of a database. This function takes the actual date and
adds the offset entered in “field name” Therefore the date field will
be added by the value defined in “field name” by days.
There´s a double check possibility activating the checkbox „User
inquiry“. The generated date can be controlled and changed by the
operator. If the checkbox is “active”, the option can turned on or
off.
page 181
Z1 Remote Manager
Submenu Directories
In the settings menu directories you have to register the possibility
existing label directories. Sign up is that this subdirectory is displayed
in the file selection dialog.
"Subdirectory include" means that all subdirectories of a registered
folder are also displayed for selection.
page 182
Z1 Remote Manager
page 183
Z1 Remote Manager
Appendix
Directory structure
The Z1 Remote Manager software has the following directory and sub-directories:
page 184
Z1 Remote Manager
page 185