Nynas AB

PRODUCT DATA SHEET


Nytro Libra

Severely Hydrotreated Insulating Oil Issuing date: 2008-03-03


Property Unit Test method Guaranteed data Typical data
IEC Min Max
1. Physical
Appearance IEC 60296 Clear, free from sediment complies
Density, 20°C ISO 12185
3
kg/dm 0,895 0,879
Viscosity, 40°C ISO 3104
2
mm /s 12,0 9,4
Viscosity, -30°C ISO 3104
2
mm /s 1800 1100
Pour point °C ISO 3016 -40 -57

2. Chemical
Acidity mg KOH/g IEC 62021 0,01 <0,01
Corrosive sulphur DIN 51353 non-corrosive non-corrosive
Corrosive sulphur ASTM D 1275 B non-corrosive non-corrosive
Corrosive sulphur IEC 62535 non-corrosive non-corrosive
Aromatic content % IEC 60590 11
Antioxidant, phenols Wt % IEC 60666 not detectable not detectable
Water content mg/kg IEC 60814 30 <20
Furfural content mg/kg IEC 61198 0,1 <0,1

3. Electrical
Dielectric dissipation factor (DDF) IEC 60247 0,005 <0,001
at 90°C
Interfacial tension mN/m ISO 6295 40 48
Breakdown voltage
- Before treatment kV IEC 60156 30 40-60
- After treatment kV 70 >70

4. Oxidation stability
At 120°C, 164 h IEC 61125 C
Total acidity mg KOH/g 1,2 0,25
Sludge Wt % 0,8 0,08
DDF/90°C 0,500 0,080

6. Health, safety and environment


Flash point, PM °C ISO 2719 135 148
DMSO extractable compounds Wt % IP 346 3 <3
PCB IEC 61619 not detectable not detectable

Nytro Libra is an uninhibited insulating oil, meeting IEC 60296 (03) General specifications.