Ethernet Communication Module: Application Manual
Ethernet Communication Module: Application Manual
Warning
Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent
damages on the device or injuries to staff.
IFD9507 is an OPEN TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity,
electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g.
key or specific tools are required for operating the enclosure) in case danger and damage on the device may occur.
IFD9507 is to be used for controlling the operating machine and equipment. In order not to damage it, only
qualified professional staff familiar with the structure and operation of IFD9507 can install, operate, wire and
maintain it.
DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check
all the wirings again before switching on the power and DO NOT touch any terminal when the power is switched
on. Make sure the ground terminal is correctly grounded in order to prevent electromagnetic interference.
Table of Contents
1 INTRODUCTION...................................................................................................................................4
1.1 Features ......................................................................................................................................4
1.2 Specifications ..............................................................................................................................4
2 PRODUCT PROFILE & OUTLINE .......................................................................................................6
2.1 Dimension ...................................................................................................................................6
2.2 Product Profiles ...........................................................................................................................6
2.3 LED Indicators.............................................................................................................................6
2.4 RJ-11 PIN Definition ....................................................................................................................7
2.5 RJ-45 PIN Definition....................................................................................................................7
2.6 RS-232 PIN Definition .................................................................................................................7
2.7 Address Switch ...........................................................................................................................7
2.8 Data Format ................................................................................................................................8
2.9 Baud Rate for Modbus Communication ......................................................................................8
2.10 Feed-through Terminal PIN Definition .........................................................................................8
3 INSTALLATION & WIRING ..................................................................................................................9
3.1 How to Install...............................................................................................................................9
3.2 How to Connect IFD9507 to Network..........................................................................................9
4 REGISTERS IN IFD9507 ....................................................................................................................10
4.1 Basic Registers (BR) .................................................................................................................10
4.2 Explanations on BR...................................................................................................................10
4.3 Alarm Registers (AL) in IFD9507 ..............................................................................................13
1 Introduction
Thank you for choosing Delta’s IFD9507 module. To correctly install and operate IFD9507, please read the
manual carefully before using the module.
IFD9507 is an Ethernet communication module for remote setting and communication through Delta’s DCISoft
1.01.
IFD9507 has 3 digital input contacts which will send messages to designated E-Mail addresses after being
triggered. IFD9507 supports Modbus TCP communication protocol and can conduct remote monitoring by using
graphic software or human machine interface. IFD9507 can be the master of Modbus TCP, sending out Modbus
TCP instructions and controlling the peripheral equipment. IFD9507 supports Ethernet/IP communication protocol
and can control device between Ethernet/IP protocols with Modbus protocol. IFD9507 can be a slave as well,
receiving Modbus instructions sent from other masters and transferring them to another Modbus communication
network or Ethernet/IP communication network through Ethernet. In addition, under MDI/MDI-X auto-detection, it
does not need to jump wire in selecting the network cable. See the contents below for more detailed instructions
on IFD9507 module.
1.1 Features
z Auto-detects 10/100 Mbps transmission speed; MDI/MDI-X auto-detection
z The monitor table temporarily stores the monitored data for the user to fast save or acquire the data.
z Supports Modbus TCP protocol (supports Master and Slave mode)
z Supports Ethernet/IP protocol (supports Master and Slave mode)
z Able to send out emails after being triggered.
z The station address, RS-485 communication format and baud rate can be set up externally
1.2 Specifications
Network interface
Item Specification
Item Specification
Item Specification
Interface RJ-11
Number of ports 1 Port
Transmission method RS-485
Transmission speed 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Communication
Modbus, User Define
protocol
Terminal block
Item Specification
Interface Feed-through terminal 10PIN
Transmission method RS-485
Transmission distance 1,200m
Transmission speed 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Communication
Modbus, User Define
protocol
Max. number of
32
stations
Environment
Item Specification
ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: ±2KV, Digital Input: ±2KV,
Communication I/O: ±2KV
RS (IEC 61131-2, IEC 61000-4-3): 80MHz ~ 1GHz, 10V/m. 1.4GHz ~ 2.0GHz,
Noise immunity 10V/m
Conducted Susceptibility Test (EN61000-4-6, IEC61131-2 9.10): 150KHz ~
80MHz, 3V/m
Surge Test (Biwave IEC61132-2, IEC61000-4-5):
Power line 0.5KV DM, Ethernet 0.5KV CM, RS-485 0.5KV CM
Operation temperature 0°C ~ 55 oC (temperature), 50 ~ 95% (humidity), pollution degree 2
Storage temperature -25°C ~ 70 oC (temperature), 5 ~ 95% (humidity)
Vibration/shock International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 &
immunity\ IEC 68-2-27 (TEST Ea)
Certificates IEC 61131-2, UL508
Electrical specifications
Item Specification
Unit: mm
1 Communication ports: RS-485, Ethernet, RS-232 6 RS-485 indicator, Reset button, Ethernet indicator
2 Power indicator 7 Module name
8 RS-485 connector, digital input points, power input
3 Address setup rotary switch。
point, earth point
4 Communication format/baud rate setup switch 9 DIN rail connector
5 Message display
PC Master
Ethernet
Human
AC motor Temperature
machine
driver controller
interface