Philips Tbs461 2Xtl5-35W HFP Ac-Mlo /: Luminaire Data Sheet
Philips Tbs461 2Xtl5-35W HFP Ac-Mlo /: Luminaire Data Sheet
Philips Tbs461 2Xtl5-35W HFP Ac-Mlo /: Luminaire Data Sheet
29.10.2018
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Operator
Telephone
Fax
e-Mail
Height of Room: 3.000 m, Mounting Height: 3.000 m, Maintenance factor: Values in Lux, Scale 1:84
0.67
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS FBS270 1xPL-C/2P18W C
1 8 294 864 18.0
+GBS271 RL (Type 1)* (1.000)
*Modified Technical Specifications Total: 2350 Total: 6912 144.0
Specific connected load: 3.16 W/m² = 9.20 W/m²/100 lx (Ground area: 45.63 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 29 4.91 34 / /
Floor 26 5.26 31 20 2.00
Ceiling 0.00 5.66 5.66 70 1.26
Wall 1 4.42 5.43 9.85 50 1.57
Wall 2 3.51 5.22 8.72 50 1.39
Wall 3 4.42 5.42 9.84 50 1.57
Wall 4 3.51 5.24 8.74 50 1.39
Specific connected load: 3.16 W/m² = 9.20 W/m²/100 lx (Ground area: 45.63 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.000 m, Mounting Height: 3.000 m, Maintenance factor: Values in Lux, Scale 1:56
0.67
Surface [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 17 1.99 60 0.116
Floor 20 15 4.52 35 0.294
Ceiling 70 2.02 1.64 2.35 0.812
Walls (4) 50 2.99 1.47 7.15 /
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS FBS270 1xPL-C/2P18W C
1 1 408 1200 36.0
+GBS271 RL (Type 1)* (1.000)
*Modified Technical Specifications Total: 408 Total: 1200 36.0
Specific connected load: 2.15 W/m² = 12.53 W/m²/100 lx (Ground area: 16.77 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 16 1.51 17 / /
Floor 13 1.88 15 20 0.98
Ceiling 0.00 2.02 2.02 70 0.45
Wall 1 0.99 1.97 2.96 50 0.47
Wall 2 1.04 1.98 3.02 50 0.48
Wall 3 0.99 1.96 2.95 50 0.47
Wall 4 1.04 1.98 3.02 50 0.48
Specific connected load: 2.15 W/m² = 12.53 W/m²/100 lx (Ground area: 16.77 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.000 m, Mounting Height: 3.090 m, Maintenance factor: Values in Lux, Scale 1:415
0.67
Surface [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 10 0.96 35 0.094
Floor 20 10.00 1.10 27 0.110
Ceiling 70 2.01 1.10 2.92 0.549
Walls (4) 50 2.90 1.03 16 /
Workplane:
Height: 0.750 m
Grid: 128 x 128 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.278, Ceiling / Working Plane: 0.199.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TBS412 2xTL5-35W HFP C6 (Type
1 45 338 470 10.0
1)* (1.000)
*Modified Technical Specifications Total: 15228 Total: 21150 450.0
Specific connected load: 0.39 W/m² = 3.85 W/m²/100 lx (Ground area: 1148.40 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 8.61 1.58 10 / /
Floor 8.40 1.59 10.00 20 0.64
Ceiling 0.00 2.01 2.01 70 0.45
Wall 1 1.72 1.67 3.39 50 0.54
Wall 2 0.01 1.53 1.54 50 0.25
Wall 3 1.72 1.66 3.38 50 0.54
Wall 4 0.01 1.45 1.46 50 0.23
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.278, Ceiling / Working Plane: 0.199.
Specific connected load: 0.39 W/m² = 3.85 W/m²/100 lx (Ground area: 1148.40 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.100 m, Maintenance factor: 0.67 Values in Lux, Scale 1:151
Surface [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 32 4.09 106 0.128
Floor 20 29 7.56 71 0.261
Ceiling 70 5.10 2.57 7.81 0.504
Walls (4) 50 10 2.74 44 /
Workplane:
Height: 0.750 m
Grid: 128 x 64 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.310, Ceiling / Working Plane: 0.160.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TBS412 2xTL5-35W HFP C6 (Type
1 6 622 864 18.0
1)* (1.000)
PHILIPS TBS412 2xTL5-35W HFP C6 (Type
2 1 622 864 10.0
2)* (1.000)
*Modified Technical Specifications Total: 4355 Total: 6048 118.0
Specific connected load: 1.40 W/m² = 4.40 W/m²/100 lx (Ground area: 84.00 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 28 4.43 32 / /
Floor 24 4.82 29 20 1.84
Ceiling 0.00 5.10 5.10 70 1.14
Wall 1 6.58 4.86 11 50 1.82
Wall 2 1.15 3.76 4.92 50 0.78
Wall 3 6.58 4.85 11 50 1.82
Wall 4 1.15 3.76 4.91 50 0.78
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.310, Ceiling / Working Plane: 0.160.
Specific connected load: 1.40 W/m² = 4.40 W/m²/100 lx (Ground area: 84.00 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.000 m, Mounting Height: 3.000 m, Maintenance factor: Values in Lux, Scale 1:206
0.67
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS FBS261 1xPL-C/4P18W HFP C
1 8 732 1200 18.0
(1.000)
Total: 5856 Total: 9600 144.0
Specific connected load: 1.11 W/m² = 3.58 W/m²/100 lx (Ground area: 129.60 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 27 4.04 31 / /
Floor 25 4.16 30 20 1.88
Ceiling 0.00 5.38 5.38 70 1.20
Wall 1 0.83 4.01 4.83 50 0.77
Wall 2 6.05 4.45 11 50 1.67
Wall 3 0.83 4.01 4.84 50 0.77
Wall 4 6.05 4.48 11 50 1.68
Specific connected load: 1.11 W/m² = 3.58 W/m²/100 lx (Ground area: 129.60 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.100 m, Mounting Height: 3.100 m, Maintenance factor: Values in Lux, Scale 1:58
0.67
Surface [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 39 2.48 128 0.064
Floor 20 34 5.58 76 0.162
Ceiling 70 4.80 2.74 6.68 0.571
Walls (4) 50 7.73 2.67 38 /
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TCS460 2xTL5-13W HFP C8 (Type
1 1 1817 2300 10.0
1)* (1.000)
*Modified Technical Specifications Total: 1817 Total: 2300 10.0
Specific connected load: 0.31 W/m² = 0.81 W/m²/100 lx (Ground area: 32.00 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 35 3.34 39 / /
Floor 30 4.32 34 20 2.19
Ceiling 0.00 4.80 4.80 70 1.07
Wall 1 4.87 4.52 9.39 50 1.49
Wall 2 0.68 3.73 4.41 50 0.70
Wall 3 4.87 4.52 9.39 50 1.49
Wall 4 0.68 3.73 4.41 50 0.70
Specific connected load: 0.31 W/m² = 0.81 W/m²/100 lx (Ground area: 32.00 m²)
Operator
Telephone
Fax
e-Mail
R. Arsip / Summary
Height of Room: 3.100 m, Mounting Height: 3.100 m, Maintenance factor: Values in Lux, Scale 1:131
0.67
Surface [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 92 17 206 0.182
Floor 20 83 28 137 0.341
Ceiling 70 15 8.62 19 0.577
Walls (4) 50 30 8.91 135 /
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TCS460 2xTL5-13W HFP C8
1 6 1817 2300 31.0
(1.000)
Total: 10902 Total: 13800 186.0
Specific connected load: 2.54 W/m² = 2.76 W/m²/100 lx (Ground area: 73.20 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 79 13 92 / /
Floor 69 14 83 20 5.30
Ceiling 0.00 15 15 70 3.33
Wall 1 19 14 33 50 5.22
Wall 2 5.56 13 18 50 2.89
Wall 3 19 14 33 50 5.20
Wall 4 5.56 13 18 50 2.89
Specific connected load: 2.54 W/m² = 2.76 W/m²/100 lx (Ground area: 73.20 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.100 m, Mounting Height: 3.100 m, Maintenance factor: Values in Lux, Scale 1:110
0.67
Surface [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 26 3.29 63 0.125
Floor 20 24 6.88 43 0.282
Ceiling 70 3.77 2.35 4.63 0.622
Walls (4) 50 6.41 2.39 21 /
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS FBS270 1xPL-C/2P18W C
1 6 408 1200 18.0
+GBS271 RL (Type 1)* (1.000)
*Modified Technical Specifications Total: 2448 Total: 7200 108.0
Specific connected load: 1.76 W/m² = 6.69 W/m²/100 lx (Ground area: 61.20 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 23 2.91 26 / /
Floor 21 3.19 24 20 1.55
Ceiling 0.00 3.77 3.77 70 0.84
Wall 1 3.52 3.49 7.01 50 1.12
Wall 2 0.92 3.19 4.10 50 0.65
Wall 3 3.52 3.49 7.01 50 1.12
Wall 4 0.91 3.19 4.10 50 0.65
Specific connected load: 1.76 W/m² = 6.69 W/m²/100 lx (Ground area: 61.20 m²)
Operator
Telephone
Fax
e-Mail
lobby 2 / Summary
Height of Room: 2.800 m, Mounting Height: 2.800 m, Maintenance factor: Values in Lux, Scale 1:124
0.67
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TCS460 H3L 2xTL5-13W HFP AC-
1 12 1702 2300 10.0
MLO (Type 1)* (1.000)
*Modified Technical Specifications Total: 20424 Total: 27600 120.0
Specific connected load: 1.30 W/m² = 0.87 W/m²/100 lx (Ground area: 92.16 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 130 19 150 / /
Floor 120 20 140 20 8.93
Ceiling 0.00 25 25 70 5.60
Wall 1 16 22 38 50 6.11
Wall 2 32 21 53 50 8.50
Wall 3 16 22 38 50 6.10
Wall 4 32 21 53 50 8.49
Specific connected load: 1.30 W/m² = 0.87 W/m²/100 lx (Ground area: 92.16 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.100 m, Mounting Height: 3.190 m, Maintenance factor: Values in Lux, Scale 1:45
0.67
Workplane:
Height: 0.750 m
Grid: 64 x 64 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.260, Ceiling / Working Plane: 0.127.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TBS415 2xTL5-35W HFP C6 (Type
1 1 4788 6650 36.0
1)* (1.000)
*Modified Technical Specifications Total: 4788 Total: 6650 36.0
Specific connected load: 2.57 W/m² = 1.33 W/m²/100 lx (Ground area: 14.00 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 167 26 193 / /
Floor 124 31 155 20 9.85
Ceiling 0.00 24 24 70 5.43
Wall 1 31 27 58 50 9.16
Wall 2 32 26 59 50 9.32
Wall 3 31 27 58 50 9.16
Wall 4 32 26 58 50 9.29
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.260, Ceiling / Working Plane: 0.127.
Specific connected load: 2.57 W/m² = 1.33 W/m²/100 lx (Ground area: 14.00 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.100 m, Mounting Height: 3.195 m, Maintenance factor: Values in Lux, Scale 1:45
0.67
Workplane:
Height: 0.750 m
Grid: 64 x 64 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.330, Ceiling / Working Plane: 0.146.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TBS463 2xTL5-35W HFP AC-MLO
1 1 3857 6650 36.0
(Type 1)* (1.000)
*Modified Technical Specifications Total: 3857 Total: 6650 36.0
Specific connected load: 2.57 W/m² = 1.79 W/m²/100 lx (Ground area: 14.00 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 121 23 144 / /
Floor 89 26 114 20 7.29
Ceiling 0.01 21 21 70 4.68
Wall 1 30 22 52 50 8.27
Wall 2 28 22 50 50 7.97
Wall 3 30 22 52 50 8.27
Wall 4 28 22 50 50 7.95
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.330, Ceiling / Working Plane: 0.146.
Specific connected load: 2.57 W/m² = 1.79 W/m²/100 lx (Ground area: 14.00 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.100 m, Mounting Height: 3.190 m, Maintenance factor: Values in Lux, Scale 1:49
0.67
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TBS411 2xTL5-13W HFP C6 (Type
1 1 1725 2300 10.0
1)* (1.000)
*Modified Technical Specifications Total: 1725 Total: 2300 10.0
Specific connected load: 0.73 W/m² = 1.02 W/m²/100 lx (Ground area: 13.68 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 62 9.40 72 / /
Floor 46 11 57 20 3.64
Ceiling 0.00 9.05 9.05 70 2.02
Wall 1 12 9.67 22 50 3.44
Wall 2 11 9.75 21 50 3.32
Wall 3 12 9.60 22 50 3.43
Wall 4 11 9.74 21 50 3.32
Specific connected load: 0.73 W/m² = 1.02 W/m²/100 lx (Ground area: 13.68 m²)
Operator
Telephone
Fax
e-Mail
Height of Room: 3.100 m, Mounting Height: 3.100 m, Maintenance factor: Values in Lux, Scale 1:56
0.67
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TBS461 2xTL5-35W HFP AC-MLO
1 1 3857 6650 36.0
(Type 1)* (1.000)
*Modified Technical Specifications Total: 3857 Total: 6650 36.0
Specific connected load: 1.63 W/m² = 1.55 W/m²/100 lx (Ground area: 22.03 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 92 13 105 / /
Floor 74 16 89 20 5.68
Ceiling 0.01 15 15 70 3.36
Wall 1 18 14 32 50 5.13
Wall 2 15 14 29 50 4.66
Wall 3 18 14 32 50 5.12
Wall 4 15 14 29 50 4.65
Specific connected load: 1.63 W/m² = 1.55 W/m²/100 lx (Ground area: 22.03 m²)