Energy Saving Refrigerated Air Dryer High Pressure Refrigerated Air Dryers

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

High

Energy
Pressure
SavingRefrigerated
RefrigeratedAir
AirDryers
Dryer
HES
H PSEETRS
I EESR I3E7S5 03 0t ot o1 23500000 ssccffm
m ((65317 1
t ot o
5 120102 3
n8m n
3
/m
h )3 / h )
Compressed Air Treatment Solutions

H PET Series
Hankison HPET refrigerated air dryers are an integral component for high pressure
compressed air installations. A trusted brand name known since 1948, Hankison air
treatment products remove water vapor, solid particulate and oil areosls and vapor for
efficient compressed air systems. Designed for 725 psig (50 bar) operation, applications
for HPET dryers include blow molding, aeronautical valve testing, pharmaceutical
packaging and injection molding.

Hankison HPET Series dryers are built in accordance to UL/ CSA certification and offer
time-tested, field proven technology guaranteed to provide years of trouble free service.

Pr o d u c t Fe a t u r e s a n d B e n e f i t s
Supreme Craftmanship
•  16 stainless steel brazed plate heat exchangers- No pre-filtration required
3
• Rugged hermetically sealed refrigeration systems provide years of trouble free service
• Employs environmentally friendly HFC refrigerants
• Unique cabinet design promotes ease of access to perform routine maintenance
Precision hot gas bypass valve maintains evaportator temperature with freeze-ups

Filtration
• S tandard filter/separator removes bulk liquids and particles down to 3 micron in size
• Timed electric condensate drain reliably discharges contamination from system
• Optional filtration available for Normal and Severe Operation

User-Friendly Instrumentation
• Indication lights include:
Power on
Compressor on
Refrigerant fault alarm
Dew point temperature indicator
Timer drain programming mode

Options
• Dry contact for fault condition
Product Specifications

H o w i t Wo r k s : Ai r D r y i n g C i r c u i t
Compressed air, saturated with water vapor, enters the air-to-air heat exchanger (A), is precooled by
the outgoing chilled air, and then directed to the air-to-refrigerant (evaporator) heat exchanger (B)
where it is further cooled by the refrigeration system. As the air is cooled, water vapor condenses
into liquid droplets which are removed by the separator/filter (C) and discharged from the dryer by
an automatic drain (D). Dry, chilled air then returns through the air-to-air heat exchanger where it is
reheated before exiting the dryer.

H P E T S e r i e s Pr o d u c t S p e c i f i c a t i o n s

Model Rated Flow1 Pr e s s u r e D r o p M a x . Wo r k i n g Refrigeration Vo l t a g e Inlet/Outlet Height Width Depth We i g h t


Pr e s s u r e System Connections

scfm n m 3/ h r psig bar psig bar hp in in lbs

H P E T- 0 . 1 7 30 51 725 50 0.17 0.5 NPT 26 18 21 95


H P E T- 0 . 2 45 76 725 50 0.2 0.5 NPT 26 18 21 95
115/1/60
H P E T- 0 . 2 5 65 110 725 50 0.25 0.5 NPT 26 18 21 95
H P E T- 0 . 3 3 95 161 725 50 0.33 0.5 NPT 26 18 21 95

H P E T- 0 . 5 165 221 1.7 0.12 725 50 0.5 100/1/50 1.5 NPT 37.6 25.6 19.6 251
115/1/60
208-230/1/60
H P E T- 0 . 7 5 200 340 1.9 0.13 725 50 0.75 220-240/1/50 1.5 NPT 37.6 25.6 19.6 279

H P E T- 1 . 0 300 510 2.4 0.17 725 50 1.0 1.5 NPT 38.6 32.2 32.2 425
H P E T- 1 . 5 500 850 4.6 0.32 725 50 1.5 1.5 NPT 38.6 32.2 32.2 463
H P E T- 2 . 5 750 1275 4.5 0.32 725 50 2.5 1.5 NPT 58.1 32.2 41.6 691
H P E T- 3 . 5 1000 1700 3.7 0.26 725 50 3.5 460/3/60 1.5 NPT 58.1 32.2 41.6 734
H P E T- 4 1250 2125 3.1 0.22 725 50 4 380-420/3/50 3 NPT 59 52 52 889
H P E T- 6 1750 2975 6.2 0.43 725 50 6 3 NPT 59 52 52 939
H P E T- 7 . 5 2000 3400 3.6 0.25 725 50 7.5 3 NPT 59 52 52 1,204
H P E T- 1 0 3000 5100 4.6 0.32 725 50 10 3 NPT 59 52 52 1,329

1 R a t e d F l ow C a p a c i t y - C o n d i t i o n s a r e 1 0 0 ° F ( 3 8 ° C ) i n l e t t e m p e r a t u r e , s a t u r a t e d w i t h w a t e r v a p o r, 7 2 5 p s i g ( 5 0 b a r ) i n l e t p r e s s u r e , 1 0 0 ° F ( 3 8 ° C )
ambient temperature, 60Hz . 50Hz units are available.

H PET Series Optional Filtration


3 Micron 1 Micron
Selecting your Filtration
Refrigerated
Pa r t i c u l a t e Pa r t i c u l a t e When selecting filtration for your HPET system consider your operating conditions. Normal
Dryer Model
Pr e f i l t e r Af t e r f i l t e r
operating conditions utilize Grade 7 and 3 filtration. For severe opertating conditions utilize Grade
H P E T- 1 HF9-20-8-69 HF7-20-8-69
H P E T- 1 . 5 HF9-24-8-69 HF7-24-8-69 9, 7, and 3 filtration in your system.
H P E T- 2 . 5 - H P E T- 4 HF9-32-8-69 HF7-32-8-69
H P E T- 6 - H P E T- 1 0 HF9-52-24-48 HF7-52-24-48

Capacity Correction Factors


To adjust dryer capacity for conditions other than rated, use Correction Factors (multipliers) from Tables 1 and 2.
Example: What is the capacity of an HPET-3.5 when the compressed air at the inlet to the dryer is 500 psig (34.5 bar) and 110°F (43°C), the ambient temperature is 90°F (32°C), and
the operating voltage is 380/3/50? Answer: 1,000 scfm (rated flow from Product Specifications Table) x 0.83 (Correction Factor from Table 1) x 1.06 (Correction Factor from Table 2)
x 0.83 (Electrical Frequency for 50 Hz, for 60 Hz no adjustment is required) = 730 scfm (1,240 nm3/h).

Table 1 - Inlet Temperature & Pressure Table 2 - Ambient Temperature*


I n l e t Pr e s s u r e 80°F ­­9 0 ° F 100°F 110°F 120°F Am b i e n t 80°F 90°F 100°F 110°F

27°C 32°C 38°C 43°F 49°F Te m p e r a t u r e 27°C 32°C 38°C 49°C

300 psig to MWP


1.49 1.19 1.0 .83 .72 Multiplier 1.12 1.06 1.00 0.94
20 bar to MWP
* A i r - c o o l e d m o d e l s o n l y. F o r w a t e r - c o o l e d u s e a 1 . 1 5 m u l t i p l i e r i f
cooling water is less than 95°F (35°C).
3
HPET Series
30 to 300 scfm

( 5 1 t o 5 1 0 0 n m 3/ h )

Global locations
S PX F LOW U S A H A N K I S O N R E N TA L CA N A DA G E R MANY A S I A PAC I F I C

4647 SW 40th Avenue NORTH EAST 1415 California Avenue Konrad-Zuse-Str. 25 5th Floor, Park Center,
Ocala, Florida 34474-5788 U.S.A. 100 Commerce Drive, Suite 40 Brockville, ON, Canada D-47445 Moers Germany No.1568 Huashan Road,
P: (724) 745-1555 Washington, PA 15301 k6v 7h7 T: (+49) 2841-8190 Shanghai China
F: (724) 745-6040 P: (724) 225-1470 T: (800) 267-3884 F: (+49) 2841-87112 T: +86 (021) 2208-5840
E: [email protected] F: (724) 222-1317 F: (800) 318-0952 E:  [email protected] F: +86 (021) 2208-5866
E: [email protected] E: [email protected]
S PX F LOW S PX F LOW

H A N K I S O N R E N TA L S PX F LOW I N D IA KO R E A

SOUTHWE ST S O U T H A M E R I CA SPX India PVT, LTD #87, Jangansandan 9-ro,


8002 Breen Drive
Rua Joao Daprat, 231 b Manufacturing G-72/73 Jangan-eup, Gijang-gun,
Houston, TX 77064 U.S.A.
P: (800) 379-3711 09600-010-SÃ0 Bernardo Riico Industrial Area Busan, Rep. of Korea

E: [email protected] Do Campo, SP Mansarovar, RAJASTHAN T: +82 (51) 728-5360

S PX F LOW Brazil Jaipur 302 020 F: +82 (51) 728-5359


T: +55 (11) 2166-4050 India
F: +55 (11) 2166-4070 T: (+91) 141-2396759
S PX F LOW F:(+91) 141-2395048
S PX F LOW

S PX F LOW

4647 SW 40th Avenue


Ocala, Florida 34474-5788 U.S.A.
P: (724) 745-1555
F: (724) 745-6040

E: [email protected]
www.spxflow.com/hankison

SPX FLOW, Inc. reserves the right to incorporate our latest design and material changes without notice or obligation.

Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should not be relied upon unless confirmed
in writing. Please contact your local sales representative for product availability in your region. For more information visit www.spxflow.com.
The green “ ” and “ ” are trademarks of SPX FLOW, Inc.
Bulletin: HPET_US Version: 08/2018 COPYRIGHT © 2018 SPX FLOW INC.

You might also like