100% found this document useful (1 vote)
152 views6 pages

Varicon e

The document describes the VARICON variable-speed drive unit with field bus or PLC connection. It has integrated interference suppression and requires no additional components. It provides easy installation and configuration via PLC, InterBus-S or Profibus-DP interfaces. The drive parameters are pre-adjusted for optimal efficiency with the motor type.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
152 views6 pages

Varicon e

The document describes the VARICON variable-speed drive unit with field bus or PLC connection. It has integrated interference suppression and requires no additional components. It provides easy installation and configuration via PLC, InterBus-S or Profibus-DP interfaces. The drive parameters are pre-adjusted for optimal efficiency with the motor type.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

VARICON: the variable-speed drive unit with

field bus or PLC connection

There is no longer any need for long leads between the Advantages:
frequency inverter and the motor. External line and • Easy installation
motor filters are also unnecessary, since complete inter- • 16 kHz switching frequency for low-noise operation
ference suppression is already integrated. • Direct PLC or InterBus-S connection
The effort required for installation is comperable with • High protection system IP 54
that of a simple motor. • Coordinated ventilation system
The efficiency characteristics have been optimized for • No additional components required for
the Type of motor concerned in each case. conformity to EMC regulations
• Conforms to CE standards
The drives are available with PLC, InterBus-S or Profibus-
DP-Interface as a standard feature. • Possibility of changing quickly from one set of drive
parameterisation to another via master computer
The drive parameters are pre-adjusted.
• Network via serial interface

PLC interface
In addition to the 24 V control inputs, the PLC interface
also includes an analog input and a serial data inter-
face (RS 485) Optional: special interface with fan
control and actual speed output interface.
The signal relays are configurable. 13 functions are
available.
All control ports, including the serial Interface, are electri-
cally isolated. The power is supplied from either internal
or external sources.

Advantages for the user:


• Analog input
• Configurable outputs
• Potential-free 24 V and 10 V power source for the
input
• Adaption to the specific application via the Control
unit

VARICON with Fieldbus profile


InterBus-S or Profibus-DP
The effort required for installation is negligible: simply
plug in the bus cable and connect to the power supply.
It goes without saying that VARICON with InterBus-S
Interface supports the DRIVECOM profile 21.

Advantages for the user:


• Easy installation
• Low installation costs
• Plug-in bus cable
• Direct connection to the fieldbus

Technical modifications reserved.

2
Block circuit diagram

M External fan
Line filter Line-Side rectifierBuffer Storage Powerinverter

M Encoder
N 3
L1
Temp
3-phase Load
PE
motor

UZK+
Safe isolation see
AUS1
VDE 0160
STRCHOP
Chopper

CPU / PWM
Power inverter control

PLC control interface


Relay outputs
Auxiliary Isolation to Seriel- Analog-
voltage VDE standards Interface Interface

24V 10V
70mA 10mA

S7 S2 S8

1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
EN

Optional A1
A2
operator
terminal

RS 485 ext. A-IN Out Out


ext. Vcc 13-30 V Relay 2 Relay 1

PLC-Interface with SIO RS 485


PLC control interface
Relay outp.
Auxiliary Isolation to Seriel- Analog-
voltage VDE standards Interface Interface

24V 10V
70mA 10mA

S2 S8

1 2 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 16 1718 19 20
GNDINT

F-Quit
GNDEXT
+24V

A-GND

RL1/M
RL1/S
D-IN0
D-IN1
ST-RE
ST-LI

B
A

+10V
A-IN

RL1/
24VSIO
EN

GNDEX2
B_OUT
VCCEX

A1
Encoder

A2
Line B

RS 485 ext. A-IN Out


ext. Vcc 13-30 V Relais 1

PLC-Interface with fan control

3
Typ code: Options:
• Control unit
• InterBus-S-, Profibus-Interface, other Bus-systems on request
• Interface adapter RS 485/RS 232
• Braking resistor
• Brake
• PC operating program
• Drive control
• dual track incremental encoder
• indication of actual speed
• Gear
• Setpoint potentiometer
• Mains switch

Technical data:

4
Motor data

* Shaft dimension 24 x 50 mm 1)
in just prepared 2)
without separate fan

Dimensions and available flange to DIN 42948

3)
0,18 kW Motor p1 = 0

You might also like