NLV8.4F Variable Speed Drive Compressor R134a 115-127V 50-60Hz
NLV8.4F Variable Speed Drive Compressor R134a 115-127V 50-60Hz
NLV8.4F Variable Speed Drive Compressor R134a 115-127V 50-60Hz
4F
Variable Speed Drive Compressor
R134a
115-127V 50-60Hz
General
Code number compressor (without electronic unit) 105G5960
Code number electronic unit 105N4212
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 45 -31 to 45
Voltage range V 80 - 140 80 - 140
Max. condensing temperature continuous (short) °F 140 (158) 140 (158)
Max. winding temperature continuous (short) °F 257 (275) 257 (275)
Cooling requirements
Frequency Hz 50 60
Application LBP MBP HBP LBP MBP HBP S = Static cooling normally sufficient
O = Oil cooling
90°F F2 F2 – F2 F2 –
F1 = Fan cooling 1.5 m/s
100°F F2 F2 – F2 F2 – (compressor compartment temperature
110°F F2 F2 – F2 F2 – equal to ambient temperature)
Remarks on application: F2 = Fan cooling 3.0 m/s necessary
Features SG = Suction gas cooling normally sufficent
– = not applicable in this area
Speed range rpm 2000 - 4000
Control modes with - mech. thermostat 115V ON/OFF
integrated speed control AEO*) - 5V DC ON/OFF
External speed control - 5V DC 200-400Hz
Protections - current
- speed
- temperature
*) AEO - Adaptive Energy Optimizer
Motor
Motor type permanent magnet
LRA (rated after 4 sec. UL984), HST A electronic cut-off
Cut in Current, HST A 6
Resistance, all 3 windings (77°F) Ω 2.0
Design
Displacement cu.in 0.51
Oil quantity (type) fl.oz. 10.8 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor fl.oz. 79.7
Weight: Compressor / Electronic unit lbs. 23.8 / 1.3
Dimensions
Height inch A 7.99
B 7.76
B1 –
B2 –
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks: