0% found this document useful (0 votes)
392 views3 pages

Wind Load Calculation - ASCE7-05 Method-1, Simplified Procedure - MWFRS

This document contains a wind load calculation for a building using the ASCE 7-05 simplified procedure. It provides details on the building geometry, material properties, calculation steps and results. The key steps are: [1] Determining basic wind speed, importance factor and exposure based on ASCE 7-05 tables; [2] Calculating topographic and height/exposure adjustment factors; [3] Obtaining design wind pressures from ASCE 7-05 figures adjusted for conditions. The output is design wind pressure values for different zones of the building structure.

Uploaded by

Tariqul Islam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
392 views3 pages

Wind Load Calculation - ASCE7-05 Method-1, Simplified Procedure - MWFRS

This document contains a wind load calculation for a building using the ASCE 7-05 simplified procedure. It provides details on the building geometry, material properties, calculation steps and results. The key steps are: [1] Determining basic wind speed, importance factor and exposure based on ASCE 7-05 tables; [2] Calculating topographic and height/exposure adjustment factors; [3] Obtaining design wind pressures from ASCE 7-05 figures adjusted for conditions. The output is design wind pressure values for different zones of the building structure.

Uploaded by

Tariqul Islam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

28 Jul 2022 12:30:37 - Wind Load Calculation - ASCE7-05 Method-1, Simplified Procedure - MWFRS.

sm

ASCE 7-05 Wind Load Calculation


Method-1: Simplified Procedure
Design Wind Pressure for MWFRS Project No. 22-380

Date: July 21, 2022

Custom Functions and Units

List Matrices

Tables & Calculations

1/3
28 Jul 2022 12:30:37 - Wind Load Calculation - ASCE7-05 Method-1, Simplified Procedure - MWFRS.sm

Geometric Data
Building Length
(If Gabled, Along Ridge) L 22 ft 6 in 22.5 ft [Length of Building]

Building Width
(Perpendicular to Ridge) B 31 ft 0 in 31 ft [Width of Building]

Eve Height, hEve 10 ft 0 in 10 ft [Height of Lowest Point on


Roof above Ground Surface]
Ridge Height, hRidge 16 ft 0 in 16 ft [Height of Highest Point on
Roof above Ground Surface]
Mean Roof Height, h mean hEve , hRidge 13 ft

Roof Overhang OH 1 ft 6 in

Roof Type Gabled / Hipped

Roof Slope Angle, θ 19.44 deg [Angle of Roof Slope facing


the Wind Direction]

Calculation Steps:

Building Classification Category II [Table 1-1, ASCE 7-05]

[Figures 6.1A, B, or C,
Step 1: Basic Wind Speed, Vwind 90 mph ASCE 7-05, or follow link:
https://hazards.atcouncil.org]
Step 2: Importance Factor, I 1 [Table 6-1, ASCE 7-05]

Step 3: Exposure Category, Exposure C [Section 6.5.6.3, ASCE 7-05]

Step 4: Height and Exposure [Section 6.5.7.2, ASCE 7-05]


Adjustment Coefficient λ 1.21

Adjustment Factor for


Step 5: Topographic Factor, Kzt 1 Building Height and Exposure, λ
Roof Ht Exposure
Step 6: Wind Pressure (ft) B C D
The wind pressure acting on different zones of the 15.00 1.00 1.21 1.47
building can be obtained from figure 6-2, ASCE 7-05. 20.00 1.00 1.29 1.55
The pressures are given corresponding to Exposure B,
h = 30 ft,I = 1.0, and Kzt = 1.0. The pressures presented 25.00 1.00 1.35 1.61
therein can be linearly interpolated for roof slopes not
30.00 1.00 1.40 1.66
given in the figure.
35.00 1.05 1.45 1.70
40.00 1.09 1.49 1.74
The wind pressure values (Ps30) on different zones of the 45.00 1.12 1.53 1.78
building then can be multiplied by the factor λ obtained
from the table to adjust for height and exposure conditions 50.00 1.16 1.56 1.81
of the structure under consideration. 55.00 1.19 1.59 1.84
60.00 1.22 1.62 1.87
Figure 6-2, ASCE 7-05

2/3
28 Jul 2022 12:30:37 - Wind Load Calculation - ASCE7-05 Method-1, Simplified Procedure - MWFRS.sm

The Ps30 wind loads acting on different regions of the building as obtained from figure 6-2,
ASCE 7-05 are as follows.

Simplified Design Wind Pressure, Ps30 (psf)


(Exposure b at h = 30 ft, Kzt = 1.0, with I = 1.0)
A B C D E F G H EOH GOH
Case 1 17.61 -4.78 11.77 -2.64 -15.4 -10.63 -10.7 -8.06 -21.6 -16.9
Case 2 0 0 0 0 0 0 0 0 0 0
Ref: Figure 6-2, ASCE 7-05

Step 7: Adjusted Design Wind Pressure Ps λ Kzt I Ps30 [Eqn 6-1, ASCE 7-05]

The design wind loads, adjusted for building height and exposure are as follows

Design Wind Pressure (psf)


(Adjusted for Height & Exposure)
A B C D E F G H EOH GOH
Case 1 21.31 -5.78 14.24 -3.2 -18.63 -12.87 -12.95 -9.75 -26.14 -20.45
Case 2 0 0 0 0 0 0 0 0 0 0