DG500

General Information INDICATOR DG500 RevA7

INDEX
INDEX ______________________________________________________________________________ 1 
TECHNICAL DATA ____________________________________________________________________ 3 
DIMENSIONS ________________________________________________________________________ 4 
CONFIGURATION _____________________________________________________________________ 4 

ENGLISH
KEYBOARD__________________________________________________________________________ 5 
CONNECTION SCHEME ________________________________________________________________ 7 
UNIVERSAL BOX _________________________________________________________________ 7 
SLIM BOX ______________________________________________________________________ 11 
SETTING OF THE PARAMETERS _______________________________________________________ 16 
HOW TO ENTER INTO THE PASSWORD CONFIGURATION MENU _______________________ 16 
HOW TO EXIT THE PASSWORD CONFIGURATION MENU ______________________________ 18 
LIST OF PASSWORDS THAT CAN BE SELECTED _____________________________________ 19 
PASSWORD 12: HOW TO SET THE CALIBRATION VALUE ______________________________ 20 
PASSWORD 19: SEQUENCE OF THE SETTINGS = SETTINGS MENU _____________________ 21 
PASSWORD 45: HOW TO SET THE CALIBRATION WITH A REFERENCE WEIGHT __________ 26 
PASSWORD 46 – INVERSE CALIBRATION WITH SAMPLE WEIGHT ______________________ 29 
PASSWORD 67: HOW TO MODIFY IN PERCENTAGE THE WEIGHT _______________________ 31 
PASSWORD 99: HOW TO SET THE MAXIMUM WEIGHT ________________________________ 33 
PASSWORD 155: SETTING OF THE DEFAULT VALUE _________________________________ 35 
PASSWORD 258: ACTIVATION OF THE TOTAL MIXER ON THE UNLOADING PHASE ________ 36 
PASSWORD 333: HOW TO SET THE COMPONENT ACCUMULATION MODE _______________ 37 
PASSWORD 444: HOW TO SET THE FUNCTIONING MODE _____________________________ 38 
PASSWORD 454: HOW TO SET THE UNIT OF MEASURE _______________________________ 41 
PASSWORD 456: HOW TO ENABLE THE VARIATION OF THE COMPONENT NAME/
UNLOADING POINTS _____________________________________________________________ 43 
PASSWORD 500: HOW TO SET THE END OF THE LOAD EXECUTION MODE ______________ 44 
PASSWORD 600: HOW TO SET THE WEIGHT REPEATER FUNCTION ____________________ 45 
PASSWORD 603: HOW TO ENABLE THE XL DISPLAY / EXTRA DISPLAY _________________ 46 
PASSWORD 789: CLEARING OF ALL RECIPES AND UNLOADING PROGRAMS ____________ 48 
PASSWORD 790: CLEARING OF ALL COMPONENTS AND UNLOADING POINTS ___________ 49 
PASSWORD 791: LOADING OF THE NAMES FOR DEFAULT COMPONENTS AND UNLOADING
POINTS _______________________________________________________________________ 50 
PASSWORD 800: CLEARING OF HISTORY ___________________________________________ 51 
PASSWORD 880: HOW TO BLOCK THE WEIGHING ___________________________________ 53 
PASSWORD 888: SETTING ARCHIVES AND INHIBIT PROGRAM _________________________ 54 
PASSWORD 1357: FORMATTING CARD _____________________________________________ 55 
PASSWORD 9372: SETTING OF VISUALIZATION ON THE DISPLAY ______________________ 57 
SETTING OF THE CUSTOMERS “ID” ________________________________________________ 59 
MANUAL USE OF THE INDICATOR _____________________________________________________ 60 
PARTIAL/TOTAL FUNCTION MODE _________________________________________________ 61 
NET / GROSS MODE _____________________________________________________________ 62 
TRANSFER DATA VIA USB Key (available only in some versions) _______________________ 65 

1
General information INDICATOR DG500 RevA7

SUPPLEMENTARY FUNCTIONS ________________________________________________________ 71 


PROGRAM MANAGEMENT ____________________________________________________________ 73 
HOW TO ENTER IN THE MAIN MENU TO MODIFY EACH SETTINGS ______________________73 
EDITING MENU ______________________________________________________________________ 73 
HOW TO PROGRAM THE COMPONENTS ____________________________________________73 
HOW TO PROGRAM THE RECIPES _________________________________________________75 
HOW TO SET THE ANIMALS NUMBER ______________________________________________79 
HOW TO PROGRAM THE UNLOADING POINTS _______________________________________83 
HOW TO PROGRAM THE UNLOADING PROGRAMS ___________________________________84 
EXECUTIONS MENU _________________________________________________________________ 89 
HOW TO CARRY OUT THE EXECUTION OF THE RECIPES ______________________________89 
HOW TO CARRY OUT THE EXECUTION OF THE UNLOADING PROGRAM _________________93 
SETTINGS MENU ____________________________________________________________________ 97 
PARAMETERS SUBMENU _________________________________________________________97 
CONTRAST SUBMENU ___________________________________________________________97 
ACCUMULATION MENU ______________________________________________________________ 98 
COMPONENT ACCUMULATION ____________________________________________________98 
CLEAR COMPONENT ACCUMULATION _____________________________________________98 
SERVICE MENU _____________________________________________________________________ 99 
DIAGNOSTIC SUBMENU __________________________________________________________99 
NUMBER WORKING HOURS _______________________________________________________99 
SYMBOLS _________________________________________________________________________ 100 
OPTIONAL ACCESSORIES ___________________________________________________________ 101 
PRINTER ______________________________________________________________________101 
WiNET™ MODEM _______________________________________________________________101 
CAB DISPLAY _________________________________________________________________101 
WEIGHT REPEATER ____________________________________________________________101 
XL DISPLAY ___________________________________________________________________102 
EXTRA DISPLAY _______________________________________________________________102 
Dina TEL 3_____________________________________________________________________102 
DTM™ ______________________________________________________________________103 
EASY CONTROL 2 ______________________________________________________________103 
WEIGHT TRANSMITTER 2 ________________________________________________________103 
CAN BUS Connector ____________________________________________________________104 
Activation of communication protocol J1939 ________________________________________104 
SEARCHING FOR FAULTS ___________________________________________________________ 105 
CHECK THE DAMAGED COMPONENTS ____________________________________________107 
ERROR CODES ________________________________________________________________112 
DECLARATION OF CONFORMITY __________________________________________________________ 114 
WARNINGS ________________________________________________________________________ 115 
GUARANTEE_______________________________________________________________________ 116 

2
General Information INDICATOR DG500 RevA7

TECHNICAL DATA

Range (f.s.): 0 – 999.999

ENGLISH
Resolution: 1 - 2 - 5 - 10 - 20 - 50

Accuracy: < +/- 0,015 % f.s.

-30 / +65 °C (-22 / +150 °F)


Operating temperature: (-45 °C /-49°F on request)

Power supply: 9,5 – 32 Vdc (“LOW BATTERY” alarm < 9,5 Vdc)

UNIVERSAL BOX: 233 x 230 x 112 mm (9.2 x 9.0 x 4.4


Dimensions: inches)
SLIM BOX: 220 x 190 x 80 mm (8.6 x 7.5 x 3.1 inches)

UNIVERSAL BOX: 2500gr (5.5 lbs)


Weight: SLIM BOX: 1900 gr (4.2 lbs)

Case: Specific Nylon with Glass Fiber V0

Protection grade: IP 68 *

LCD Display / Height: 6 digits (16 segments) / 45 mm (1.77 inches) **

Display view: 15 m and more (50 ft)

* Complete protection from dust and water sprinklings, guaranteed in 1 meter full immersion with
connectors closed by caps or with cables and/or accessories connected.

** Perfect visibility in any weather condition (Sunny, Cloudy, and Rainy)

3
General information INDICATOR DG500 RevA7

DIMENSIONS

CONFIGURATION

1. ON/OFF key.
2. Function and setting keys.
3. Power, sensor and accessories connectors.
4. Graphic Lower Display: number of digit variable in function of characters
visualized on 3 rows.
5. Upper Display: 6 digit LCD 45 mm to show the weight
6. Back panel.
7. Identification label.

4
General Information INDICATOR DG500 RevA7

KEYBOARD
ON – OFF Press this key in order to switching on / off the indicator

Press this key in order to enter into the main menu that contains the

ENGLISH
MENU
submenu: EDITING, EXECUTIONS, SETTINGS, ACCUMULATION,
(SELECT)
SERVICE

From the TOTAL WEIGHT mode, press this key in order to set the
ALARM
weight. When this value has been reached, the alarm will start

1- During the manual function, press this key in order to print the actual
weight value with date and time
2- The RECIPE and UNLOADING PROGRAMS that are memorized on
the weighing system can be printed through this key at the end of
each program or for a simple visualization of the program that was
memorized
BLOCK /
PRINT / SAVE 3- From the “Block Status” is possible to esc ONLY by pressing this key
4- During the Unloading Program execution it is possible to suspend the
weighing by pushing this key and resume afterwards by pushing the
same key
5- During the EDITING phase, press this key in order to save the name
of component/recipe/unloading point/unloading program.

1- During the switching on, when the message “Please Wait” appears,
press this key in order to enter in the password configuration
SETTINGS /
2- In TOTAL WEIGHT mode, press this key in order to enter in the
LEFT
SETTING MENU
3- During the EDITING phase, press this key in order to move to the left

1- During the switching on, when the message “Please Wait” appears,
press this key in order to setting the hour and the date
HOUR /
2- In TOTAL WEIGHT mode, press this key in order to display the hour
RIGHT
and the date
3- During the EDITING phase, press this key in order to move to the right

1- In the MAIN MENU, press this key in order to scroll the voices of
submenu
MINUS /
2- During the setting of the weight, press this key in order to decrease
DOWN
the value
3- During the EDITING phase, press this key in order to move down

1- In the MAIN MENU, press this key in order to scroll the voices of
submenu
PLUS / UP 2- During the setting of the weight, press this key in order to increase the
value
3- During the EDITING phase, press this key in order to move up

5
General information INDICATOR DG500 RevA7

1- In the PARTIAL FUNCTION MODE, press this key in order to zeroed


the weight that is visualized on the display
2- In the NET/GROSS MODE, press this key in order to memorize a tare
3- In the password 444, this key is used to memorize a tare, it zeroes the
PARTIAL/ display and memorizes the weight loaded until that moment,
DELETE considering it as a tare
4- During the EDITING phase, press this key in order to delete a
character
5- In the EDITING of the RECIPE, press this key in order to delete the
component

1- Press this key in order to recall in any moment the TOTAL WEIGHT
value
2- In the password 444, this key is used to visualize alternately on the
TOTAL / SET
display the net and gross weight that is the result of the net weight
CHARACTER
minus the tare previously memorized
3- During the EDITING phase, press this key in order to change the type
of character (capital letter, lower case letter, number or sign)

ENTER Press this key in order to confirm

ZERO Press this key in order to zeroed (TARE) the system

RECIPES In TOTAL WEIGHT mode, press this key in order to enter quickly in the
LIST execution of the recipes

UNLOADING
In TOTAL WEIGHT mode, press this key in order to enter quickly in the
PROGRAM
execution of the unloading programs
LIST

RESET Press once to exit any menu

SPECIAL FUNCTIONS
PARTIAL and
Press simultaneously in order to display the battery voltage
TOTAL

TOTAL and Press simultaneously in order to enter in the setting of the


ENTER customers ID

BLOCK and
Press simultaneously in order to increase the value by 100
PLUS

BLOCK and
Press simultaneously in order to decrease the value by 100
MINUS

6
General Information INDICATOR DG500 RevA7

CONNECTION SCHEME
UNIVERSAL BOX
Power and sensor connection (system with junction box)

ENGLISH

If the load cells are not all connected to the indicator, it's necessary to close the
connectors not used with the special cap.

7
General information INDICATOR DG500 RevA7

Power and sensor connection (system without junction box)

8
General Information INDICATOR DG500 RevA7

Accessories connection (system with 1 sensor connector)

ENGLISH

9
General information INDICATOR DG500 RevA7

Accessories connection (system with 4 sensor connectors)

10
General Information INDICATOR DG500 RevA7

SLIM BOX
Power and sensor connection (system with junction box)

ENGLISH

If the load cells are not all connected to the indicator, it's necessary to close the
connectors not used with the special cap.

11
General information INDICATOR DG500 RevA7

Accessories connection (system with connection box 2 accessories Hi-Tech)

12
General Information INDICATOR DG500 RevA7

Accessories connection (system without connection box 2 accessories Hi-Tech)

ENGLISH

13
General information INDICATOR DG500 RevA7

Display connection (available for UNIVERSAL BOX and for SLIM BOX)

14
Configuration INDICATOR DG500 RevA7

ENGLISH

15
Configuration INDICATOR DG500 RevA7

SETTING OF THE PARAMETERS


HOW TO ENTER INTO THE PASSWORD CONFIGURATION MENU

1 Turn on by pushing

2 Once the software revision has come


up on the lower display the message
“PLEASE WAIT”… will appear.

3 Press the setting key in order to enter


in the password configuration.

4 The first message “Config.” will


appear on the lower display;

16
Configuration INDICATOR DG500 RevA7

And afterwards

“Set password -/+”.

* Note 1

ENGLISH
5
Release the key.

It is possible increase or decrease the value by 100 units through the pressing at
the same time of the following keys:
a) BLOCK/PRINT and PLUS in order to increase by 100 units;
b) BLOCK/PRINT and MINUS in order to decrease by 100 units.

* NOTE 1

If the message “Set password -/+” does


not appear and the indicator returns in
TOTAL WEIGHT it means that the

key have not been pushed


correctly.

8 To return to the Set password -/+ mode


turn off the indicator and return to
point 1.

17
Configuration INDICATOR DG500 RevA7

HOW TO EXIT THE PASSWORD CONFIGURATION MENU

There are two ways to exit the password configuration menu:

1 Push the RESET key

After the “PLEASE WAIT” message


the indicator returns in the TOTAL
WEIGHT mode and the weight will
be seen on the display.

2 Set the password ZERO with the


PLUS and MINUS keys.

Push the ENTER key.

18
Configuration INDICATOR DG500 RevA7

After the message “PLEASE WAIT”


the indicator returns in the TOTAL
WEIGHT mode and the weight will
be seen on the display.

ENGLISH
LIST OF PASSWORDS THAT CAN BE SELECTED

12 Calibration
19 Sequence of the settings = SETTINGS MENU
45 Calibration with a reference weight
46 Inverse Calibration with sample weight
67 Modification of the weight in % (fine calibration)
99 Setting of the maximum weight (over-range)
155 Setting of the default value
258 Activation of the Total Mixer on the unloading phase
333 Component accumulation
444 How to set the functioning mode
454 Setting of kg / pounds
456 Enable the modification of the Component/Unloading Points name
500 End execution load mode
600 Functioning of the weight repeater
603 How to enable the XL display / EXTRA display
789 Clearing of all recipes and unloading programs
790 Clearing of all components and unloading points
791 Loading of the names for default components and unloading points
800 Clearing of History
880 How to block the weighing
888 Setting Archives and Inhibit Program
1357 Formatting CARD
9372 Setting of visualization on the display

19
Configuration INDICATOR DG500 RevA7

PASSWORD 12: HOW TO SET THE CALIBRATION VALUE


(Range: 1÷15000; Default: 2780)

The value must be lower then what set in the 99 password. If there are problems in
order to enter and save the calibration value, check the value set in the password
99.

1 From the modality Set password -/+,


select number 12 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

3 With the PLUS and MINUS key change


the value of this parameter if
necessary.

The calibration value depends on the


number and capacity of the load cells.
Contact dinamica generale® for
further details. If a complete system
has been bought, the DG indicators
are already calibrated.

4 Push the ENTER key to confirm the


new calibration parameter.

20
Configuration INDICATOR DG500 RevA7

5 The indicator will return to Set


password -/+.

ENGLISH
PASSWORD 19: SEQUENCE OF THE SETTINGS = SETTINGS MENU

1 It is possible enter into the SETTINGS


MENU in this way:

- From the modality Set password


-/+, select number 19 with the
PLUS and MINUS keys.

- From the modality TOTAL

WEIGHT press key

- From the TOTAL WEIGHT press

the key and selecting


the submenu
CONFIGURATIONS -
PARAMETERS.

21
Configuration INDICATOR DG500 RevA7

2 Inside this menu you could set many


values in this way:
a) Press the ENTER key in order to
select the parameter to modify.
b) Modify the number of the
parameter with the PLUS and
MINUS keys.
c) Confirm with ENTER key.

d) Press the key in order to


save the parameter.
e) Press the RESET key in order to
return back without save.

3 RESOLUTION OF THE WEIGHT


VISUALIZATION
(Default: 1)
Resolution of the weight visualization
setting that is seen on the display.

The division can be set at 1, 2, 5, 10,


20 or 50 Kg.

4 PERCENTAGE ON THE ALARM


INTERVANTION
(Range: 0-50; Default: 15)
Setting of the percentage value of the
acoustic alarm the controls the
weighing. The activation of the pre-
alarm (intermittent acoustic alarm)
corresponds to this value.

This phase is called PREALARM and Suggested value: 15.


the acoustic signal is intermittent. By
setting 15, the intermittent alarm is
activated when the value to be
loaded/unloaded is minus 15%. For
example when programming the
loading/unloading at 100 and the
percentage at 15 the value that is read
is 85 and therefore the intermittent
alarm will start.

22
Configuration INDICATOR DG500 RevA7

5 ALARM DELAY TIME


(Range: 0-60; Default: 7)
Programming of time of the acoustic
alarm at the end of a
loading/unloading.

ENGLISH
The number that is set corresponds to
the alarm time, expressed in seconds,
when the set value is reached.

The maximum programmable alarm


time is 60 seconds.

6 SETTING OF THE FILTER FOR THE


WEIGHT STABILIZATION
(Range: 0-8; Default: 4)
If the weight on the display is
unstable, the parameter has to be
increased; if, on the other hand, the
weight is too stable (slow update) the
visualization will be improved if this
value is decreased.

Once the value is been changed and


you press RESET key, the message
“Restart..PRESS ON/OFF” appears in
order to save the parameter.

7 WAY TO ADVANCE FROM ONE


COMPONENT/UNLOADING POINT TO
THE OTHER
(Default: Yes)

By setting "AUTO: Yes" the passage


from one Component/Unloading Point
to the other is automatic once the set
value has been reached and once the
alarm time has passed.
By setting "AUTO: No" the passage
from one Component/Unloading Point
to the other will have to be made
manually by pushing the ENTER key.

23
Configuration INDICATOR DG500 RevA7

8 LANGUAGE
(Default: English)
Language selection used for the
visualization of the messages. List of
the available languages:
- English
- Italian
- Spanish
- German
- French
- Russian
- Czech
- Polish

9 SET DEVICE ADDRESS


(Range: 1-255; Default: 3)

Identification code that allows the


indicator to connect, by RF, only to
those devices that have the same
address without creating problems of
interference with other devices that
use different addresses.

10 SET MOTION
(Range: 0-999; Default: 250)

Alarm that indicates sudden weight


changes that could cause damage to
the system.

If this problem is presented, verify the


installation, state of the system and
calibration values. * We advise not to change this
parameter.

24
Configuration INDICATOR DG500 RevA7

11 STABILIZATION TIME
(Default: 0)
With the PLUS and MINUS keys, you
can set the seconds that you have at
your disposition when you load a
component during the execution of the

ENGLISH
recipe.

This function is normally used for


those components that are loaded
with the loader. When the mixer is
loaded with a loader it is difficult to
put in the right amount that is
programmed on the indicator, usually
the quantity is a little less.

A count down on the upper display


advises the operator that he has N
seconds for load the component on
the mixer before the indicator is
passing on to the next component.
The weight will be saved after the
STABILIZATION TIME in order to have
the real weight.

12 READING OF THE RECIPES FROM THE MEMORY CARD


(Default: No)
With the PLUS and MINUS keys set
“Data Trans: Yes” if you want the
recipe to be read directly by the
memory card and subsequently
memorize the executions.
In this case, it is not possible modify
the recipes or the components.

If this parameter is set at “Yes”, when


the indicator is turned on without the
Data Transfer connected the message
“DT Ignored” will appear; push the
ENTER key to continue.

25
Configuration INDICATOR DG500 RevA7

With the PLUS and MINUS keys set


“Data Trans: No” if you do not want to
read the recipe directly from the
Memory Card, but only save the
executions on the internal memory of
the indicator.

Once the value is been changed and


you press RESET key, the message
“Restart..PRESS ON/OFF” appears in
order to save the parameter.

PASSWORD 45:
HOW TO SET THE CALIBRATION WITH A REFERENCE WEIGHT

1 From the modality Set password -/+,


select number 45 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

26
Configuration INDICATOR DG500 RevA7

3 The message “Calibration“ will appear


for 2 seconds, it means that the
calibration is starting.

ENGLISH
4 The message “C1 Calib Step 1“ will
appear for 2 seconds, it means that
the first step of calibration is starting.

5 The message “Set Zero“ will appear, in


this situation empty completely the
mixer and then confirm with the
ENTER key.

6 The message “Please Wait“ will


appear, the ZERO value will be saved.

7 The message “C1 Calib Step 2” will


appear for 2 seconds, it means that
the second step of calibration is
starting.

27
Configuration INDICATOR DG500 RevA7

8 Load the weight on the mixer and


insert the value of the reference
weight placed in the mixer (in Kg or
Pounds) with PLUS and MINUS keys,

then confirm with key.

* The value is only indicative


9 The message “Please Wait” will
appear, the NEW CALIBRATION value
will be saved.

10 If the message “Setting Ok!” will


appear, it means that the calibration
procedure has been finished
successfully.
If the message “E” will appear, it
means that the calibration procedure
has NOT been finished successfully;
so retry the operation from the point 1.

11 After the end of the procedure the


indicator returns to Set password -/+.

28
Configuration INDICATOR DG500 RevA7

PASSWORD 46 – INVERSE CALIBRATION WITH SAMPLE WEIGHT


This procedure allows to carry out the calibration of the weighing system on the
basis of a known weight that must be appropriately weighed on the medium in
which the weighing system is mounted.
1 From the modality Set password -/+,
select number 46 with the PLUS and

ENGLISH
MINUS keys.

2 Confirm with the ENTER key.

3 The message “Calibration“ will


appear for 2 seconds, it means that
the calibration is starting.

4 The message “C1 Calib Step 1“ will


appear for 2 seconds, it means that
the first step of calibration is
starting.

29
Configuration INDICATOR DG500 RevA7

5 Load the weight on the mixer and


insert the value of the reference
weight placed in the mixer (in Kg or
Pounds) with PLUS and MINUS keys,

then confirm with key.

* The value is only indicative


6 The message “Please Wait” will
appear, the NEW CALIBRATION
value will be saved.

7 The message “C1 Calib Step 2” will


appear for 2 seconds, it means that
the second step of calibration is
starting.

8 The message “Set Zero“ will appear,


in this situation empty completely
the mixer and then confirm with the
ENTER key.

9 The message “Please Wait“ will


appear, the ZERO value will be
saved.

10 If the message “Setting Ok!” will


appear, it means that the calibration
procedure has been finished
successfully.
If the message “E” will appear, it
means that the calibration
procedure has NOT been finished
successfully; so retry the operation
from the point 1.

11 After the end of the procedure the


indicator returns to Set password -
/+.

30
Configuration INDICATOR DG500 RevA7

PASSWORD 67: HOW TO MODIFY IN PERCENTAGE THE WEIGHT


(Range: -10.0% / +10.0%; Default: 0.0)

1 From the modality Set password -/+


select the number 67, with the PLUS
and MINUS keys.

ENGLISH
2 Confirm with the ENTER key.

3 With the PLUS and MINUS keys select


the percentage of the weight
modification.
The interval that can be set is – 10,0%
+ 10,0%.

minimum interval 0,1%.

Push ENTER key in order to confirm


4 the value of the parameter.

5 After the message SETTING OK!


appears the indicator returns to Set
password -/+.

31
Configuration INDICATOR DG500 RevA7

32
Configuration INDICATOR DG500 RevA7

PASSWORD 99: HOW TO SET THE MAXIMUM WEIGHT


(Range: 100-999999; Default: 15000)

ENGLISH
The value must be higher than what set in the password 12.

1 From the modality Set password -/+


select number 99 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

3 With the PLUS and MINUS keys


change the value of this parameter if
necessary, the range can be set at
100÷99999.

The value of this parameter is


linked to the capacity of the
machine, dinamica generale®
suggests to set the maximum
capacity of the machine.

4 Push the ENTER key in order to


confirm the value of the parameter.

5 The indicator returns to Set password


-/+.

33
Configuration INDICATOR DG500 RevA7

34
Configuration INDICATOR DG500 RevA7

PASSWORD 155: SETTING OF THE DEFAULT VALUE

1 From the modality Set password -/+


select number 155 with the PLUS and
MINUS keys.

ENGLISH
2 Confirm with the ENTER key.

3 The message “Set Default Val?” is


shown.

Press the ENTER key if you wish


restore the default values. In this case
the message “Setting OK!” appears.

Press the RESET key if you wish exit


without restore the values.

4 The indicator returns to Set password


-/+.

35
Configuration INDICATOR DG500 RevA7

PASSWORD 258:
ACTIVATION OF THE TOTAL MIXER ON THE UNLOADING PHASE
(Default: No)

1 From the modality Set password -/+


select number 258 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

3 The message “Total mixer” is shown.


Set the value with the PLUS and
MINUS keys and confirm with the
ENTER key:
- Yes: it automatically proposes, for
a few seconds, the total on the
mixer and automatically
recalculates the partition of this
total on the various unloading
points (it allows the unloading of
the real material inside of the
mixer).
- No: It NOT allows the unloading of
the real material inside of the
mixer but the material that
exceeds the value predetermined
remains inside of the mixer.
Press the RESET key if you wish exit
without save the datas.

4 The indicator returns to Set password


-/+.

36
Configuration INDICATOR DG500 RevA7

PASSWORD 333:
HOW TO SET THE COMPONENT ACCUMULATION MODE
(Default: Yes)
This function is used to save in the memory of the indicator the information about
the total loaded of the single component during the executions of all the recipes.

ENGLISH
1 From the modality PASSWORD select
the number 333 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

3 Enable and disable the COMPONENT ACCUMULATION mode

a) To enable the COMPONENT


ACCUMULATION mode, select with
the PLUS and MINUS keys
Accumul.: Yes and confirm by
pushing ENTER.

b) To disable the COMPONENT


ACCUMULATION mode, select with
the PLUS and MINUS keys
Accumul.: No and confirm by
pushing ENTER.

37
Configuration INDICATOR DG500 RevA7

4 The indicator returns to Set password -


/+.

PASSWORD 444:
HOW TO SET THE FUNCTIONING MODE
(Default: 1 - Partial/Total)

1 From the modality PASSWORD select


the number 444 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

Selection of the PARTIAL/TOTAL or GROSS/NET mode with the PLUS and MINUS
keys.

38
Configuration INDICATOR DG500 RevA7

3 In order to always visualize the loaded


weight in that precise moment, set the
function PARTIAL/TOTAL by pressing
the TOTAL key.
With the PARTIAL key it is possible to
carry out partial weighing by zeroing

ENGLISH
the display and verifying what is being
loaded in that moment.

Changing the mode from PARTIAL to


TOTAL, the previous weight will be lost
since each partial weighing will be
added to the total sum.

In this configuration it is not possible to store one tare in order to see it again, since
the system’s tare and zero coincide.
This function is indicated especially in the use of mixers or trailers in general.

PARTIAL TOTAL
UPPER LOWER
ACTION LOADED LOADED
DISPLAY DISPLAY
WEIGHT WEIGHT
200 Total Weight 0 200
Push PARTIAL 0 Partial Weight 0 200
Load 100KG 100 Partial Weight 100 300
Push TOTAL 300 Total Weight 0 300
Push PARTIAL 0 Partial Weight 0 300
Load 500KG 500 Partial Weight 500 800
Push PARTIAL 0 Partial Weight 0 800
Load 200KG 200 Partial Weight 200 1000
Push TOTAL 1000 Total Weight 0 1000
Unload everything 0 Total Weight 0 0

39
Configuration INDICATOR DG500 RevA7

By setting the function NET/GROSS,


the PARTIAL key is used to memorize
a tare, it zeroes the display and
memorizes the weight loaded until that
moment, considering it as a tare.
The TOTAL key is used to visualize
alternately on the display the net and
gross weight that is the result of the
net weight minus the tare previously
memorized.

In this function a tare value is obtained and is memorized therefore can be


visualized until the system is newly zeroed.
Such a function is indicated for fixed application with platforms in order to weigh
fruit and vegetable crates/crates by verifying the net weight and gross weight and
registering a tare without modifying the reference to the zero of the system.

UPPER LOWER NET GROSS


ACTION TARE
DISPLAY DISPLAY WEIGHT WEIGHT
200 GROSS Weight 0 200 200
Push PARTIAL 0 Set TARE 0 200 200
100 NET Weight 0 200 200
Push TOTAL 200 GROSS Weight 0 200 200
Load 100KG 300 GROSS Weight 100 300 200
Push TOTAL 100 NET Weight 100 300 200
Load 500KG 600 NET Weight 600 800 200
Push TOTAL 800 GROSS Weight 600 800 200
Unload everything 200 GROSS Weight 0 200 200
Push TOTAL 0 NET Weight 0 200 200

4 Push ENTER key in order to confirm


the value of the parameter. The
indicator will return to Set password -
/+.

40
Configuration INDICATOR DG500 RevA7

PASSWORD 454: HOW TO SET THE UNIT OF MEASURE


(Default: Kg)

1 From the modality Set password -/+


select the number 454 with the PLUS
and MINUS keys.

ENGLISH
2 Confirm with the ENTER key.

3 Selection of the unit of measure in kg or pounds with the PLUS and MINUS keys.
The same will be indicated on the tickets that come out of the printer near the
weight value.

a) By setting 0=Kg the weight will


be visualized in Kilograms.

b) By setting 1=Lb the weight will


be visualized in Pounds.

One pound = 0,454 kg

4 Push ENTER key in order to confirm the value of the parameter. The indicator
will return to Set password -/+.

41
Configuration INDICATOR DG500 RevA7

42
Configuration INDICATOR DG500 RevA7

PASSWORD 456: HOW TO ENABLE THE VARIATION OF THE


COMPONENT NAME/ UNLOADING POINTS
(Default: Yes)

1 From the modality Set password -/+


select the number 456 with the PLUS

ENGLISH
and MINUS keys.

2 Confirm with the ENTER key.

3 Possibility to enable the variation of the Component name/Unloading Points


directly on the indicator with the PLUS and MINUS keys.
a) Select Yes to enable the
Component/Unloading Points
name variation.

b) Select NO to disable the


variation of the Component/
Unloading Points name from
the indicator.

4 Push ENTER key in order to confirm


and the indicator will return to Set
password -/+.

43
Configuration INDICATOR DG500 RevA7

PASSWORD 500: HOW TO SET THE END OF THE LOAD EXECUTION


MODE

(Default: Total)
1 From the modality Set password -/+
select the number 500 with the PLUS
and MINUS keys.

2 Confirm with the ENTER key.

3 Press the PLUS and MINUS keys in


order to modify the value (Total /
Recipe / Menu).

Press ENTER key in order to confirm.

4 The indicator will immediately return


to Set password -/+.

44
Configuration INDICATOR DG500 RevA7

PASSWORD 600: HOW TO SET THE WEIGHT REPEATER FUNCTION


(Default: Menu)
1 From the modality Set password -/+
select the number 600 with the PLUS
and MINUS keys.

ENGLISH
2 Confirm with the ENTER key.

3 Select the function of the weight repeater with the PLUS and MINUS keys.

a) Select MENU in order to align the


visualization of the weight repeater
with the state of the indicator. The
weight repeater will show the
information that is visualized on the
indicator’s display.

Default value: Menu.

b) Select TOTAL in order to ALWAYS


set the visualization of the total
weight on the weight repeater
regardless of the state of the
indicator.

4 Press the ENTER key in order to


confirm the function mode and the
indicator will automatically return to
Set password -/+.

45
Configuration INDICATOR DG500 RevA7

PASSWORD 603: HOW TO ENABLE THE XL DISPLAY / EXTRA DISPLAY


(Default: Normal)
1 From the modality Set password -/+
select the number 603 with the PLUS
and MINUS keys.

2 Confirm with the ENTER key.

3 Communication authorization between the indicator and the XL Display / EXTRA


Display with the PLUS and MINUS keys.

a) Select ADVANCED to enable the


communication with the XL Display
/ EXTRA Display.

b) Select NORMAL to disable the


communication with the XL Display
/ EXTRA Display.

46
Configuration INDICATOR DG500 RevA7

c) Select FULL if there is another


device connected to the XL Display
/ EXTRA Display (ex.: Weight
Repeater, Motor Control,…) and you
want to use both.

ENGLISH
4 Press ENTER key in order to confirm
the function mode and the indicator
will automatically return to Set
password -/+.

47
Configuration INDICATOR DG500 RevA7

PASSWORD 789:
CLEARING OF ALL RECIPES AND UNLOADING PROGRAMS

1 From the modality Set password -/+


select number 789 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

3 The message “Clear all recipes,


u.prog.?” is shown.

Press the ENTER key if you wish


cancel all the datas of recipes and
unloading programs. In this case the
message “Deleted” appears.

Press the RESET key if you wish exit


without cancel the datas.

4 The indicator returns to Set password


-/+.

48
Configuration INDICATOR DG500 RevA7

PASSWORD 790:
CLEARING OF ALL COMPONENTS AND UNLOADING POINTS

1 From the modality Set password -/+


select number 790 with the PLUS and
MINUS keys.

ENGLISH
2 Confirm with the ENTER key.

3 The message “Clear all comp.


u.points?” is shown.

Press the ENTER key if you wish


cancel all the datas of components
and unloading points. In this case the
message “Memory Deleted” appears.

Press the RESET key if you wish exit


without cancel the datas.

4 The indicator returns to Set password


-/+.

49
Configuration INDICATOR DG500 RevA7

PASSWORD 791: LOADING OF THE NAMES FOR DEFAULT


COMPONENTS AND UNLOADING POINTS

1 From the modality Set password -/+


select number 791 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

The message “Set default comp.


3 u.points name?” is shown.
Press the ENTER key if you wish
loading the DEFAULT NAMES of
components and unloading points:
- Component 1
- Component 2, etc.
- Unload. Point 1
- Unload. Point 2, etc.

Press the RESET key if you wish exit


without to load the default names.

The indicator returns to Set password


4 -/+.

50
Configuration INDICATOR DG500 RevA7

PASSWORD 800: CLEARING OF HISTORY

1 From the modality Set password -/+


select number 800 with the PLUS and
MINUS keys.

ENGLISH
2 Confirm with the ENTER key.

3 With the PLUS and MINUS keys, select


the menus to zeroing:

1- N. Working Hours: it is possible


zeroing the total hours that the
indicator has worked;

2- N. Overload: it is possible zeroing


the number of overloads that are
been displayed.

4 Press the ENTER key if you wish


cancel all the datas described at point
3. In this case the messages “Confirm
deleting?” and then “Deleted”
appears.

Press the RESET key if you wish exit


without cancel the datas.

5 The indicator returns to Set password


-/+.

51
Configuration INDICATOR DG500 RevA7

52
Configuration INDICATOR DG500 RevA7

PASSWORD 880: HOW TO BLOCK THE WEIGHING


(Default: DG)
1 From the modality Set password -/+
select the number 880 with the PLUS
and MINUS keys.

ENGLISH
2 Confirm with the ENTER key.

3 Select the function of the BLOCK button with the PLUS and MINUS keys.

a) Select DG in order to enable the BLOCK


function during an execution or in Total
Weight. From the “Block Status” is possible
to esc by pressing the button:

in this case the indicator recalls the


weight that was present at the time of the block
regardless eventual changes happened during
the “Block Status”.

in this case the indicator will display the


weight considering eventual changes happened
during the “Block Status”.
b) Select M1 in order to enable the BLOCK
function ONLY during an execution (and not
in Total Weight).
From the “Block Status” is possible to esc ONLY

by pressing the button (in this case the


indicator recalls the weight that was present at
the time of the block regardless eventual
changes happened during the “Block status” ).
When the indicator returns in Total Weight will
display the weight considering eventual
changes happened during the “Block Status”.

53
Configuration INDICATOR DG500 RevA7

PASSWORD 888: SETTING ARCHIVES AND INHIBIT PROGRAM


(Default: Man+Load, FALSE, 5)

1 From the modality Set password -/+


select number 888 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

3 The first parameter is shown: SET


ARCHIVES. It is possible set one of
those values in order to save the
loading executions:
- Manual
- Load
- Man.+Load
Press the RESET key if you wish exit
without change the value.

4 To confirm and proceed on to the next


parameter, press the ENTER key.

5 The second parameter is shown:


INHIBIT PRG. It is possible enable or
disable it:
- Yes: in order to inhibit the
operator to execute the
operations on the system to
prevent loss of data;
- No: in order to deactivate the
inhibit of the operator.
Press the RESET key if you wish exit
without change the value.

54
Configuration INDICATOR DG500 RevA7

6 To confirm and proceed on to the next


parameter, press the ENTER key.

7 The third parameter is shown: SET


WARNING EXECUTION.

ENGLISH
This value corresponds to the number
of execution that miss before the card
is full. A message advises the operator
that the card is almost full.
It is possible set the value with the
PLUS and MINUS keys. Confirm it with
the ENTER key.
Press the RESET key if you wish exit
without change the value.

8 The indicator returns to Set password


-/+.

PASSWORD 1357: FORMATTING CARD

1 From the modality Set password -/+


select number 1357 with the PLUS and
MINUS keys.

2 Confirm with the ENTER key.

55
Configuration INDICATOR DG500 RevA7

3 If the card is plugged, the message


“FORMAT CARD?” appears.

Press the ENTER key in order to delete


all the datas inside of the card.

The message “Formatting..” appears


and then “Card Formatted”.

4 Press the RESET key in order to return


back without delete the datas. In this
case, the message “DT Ignored”
appears.

5 The indicator returns to Set password


-/+.

56
Configuration INDICATOR DG500 RevA7

PASSWORD 9372: SETTING OF VISUALIZATION ON THE DISPLAY


(Default: Percentual)

1 From the modality Set password -/+


select number 9372 with the PLUS and
MINUS keys.

ENGLISH
It allows to decide if and in which
mode visualize the name of the
component on the Extra Display
(Accessory that can be requested) and
on the Upper display where normally it
shows only the weight during the
executions of recipe or unloading
program.

2 Confirm with the ENTER key.

3 The message “Visual. mode” is


shown. Change the value with the
PLUS and MINUS key:

- None: NEVER, the name of the


component (unloading point) is
visualized only on the lower
graphical display.

- Percentual: the name of the


component is visualized
alternatively with the weight to
load since the value of the
weight will be increased /
decreased the % value as set in
this password.

Set the % value with the PLUS and


MINUS keys.

57
Configuration INDICATOR DG500 RevA7

- Time: the name of the


component is visualized
alternatively with the weight to
load until the seconds finish as
set in this password.

Set the value of seconds with the


PLUS and MINUS keys.

The characters will be displayed on the upper display only with standard code
ASCII characters. Any special characters will be replaced with simple
characters.

4 Press the ENTER key in order to


confirm the value of the parameter.

5 The indicator returns to Set password


-/+.

58
Configuration INDICATOR DG500 RevA7

SETTING OF THE CUSTOMERS “ID”


With this function it is possible to associate a customer “ID” with a recipe before it
is carried out.

1 Push simultaneously the TOTAL and

ENGLISH
ENTER keys.

2 Set the value of the customer ID with


the PLUS and MINUS keys.

The customer “ID” can have a


changeable value from 1 to 65000.

3 Confirm the Customer “ID” by


pushing ENTER.

4 The message “Setting Ok!” appears


on the lower display.

59
Use INDICATOR DG500 RevA7

MANUAL USE OF THE INDICATOR


TURNING ON

a) After pushing the key, on the


lower display you will see in
sequence the messages “DG500”,
the software revision number and
“Please Wait”.

b) Afterwards a weight value will appear


on the upper display and the
indication TOTAL WEIGHT on the
lower display.

The use of the indicator is


suggested 15 minutes after it has
been turned on, especially if it is
used with below zero °C * The weight value is indicative
temperatures.

The TOTAL WEIGHT value can be


recalled in any moment by pressing
the TOTAL key.

60
Use INDICATOR DG500 RevA7

PARTIAL/TOTAL FUNCTION MODE


Selected by password 444

ZEROING

ENGLISH
a) Zero with the key.
b) The message:
“Set Tare” will appear;
keep pushing the ZERO key until the
message:
“Setting Ok !” is visualized.
c) The indicator will return to the
TOTAL WEIGHT mode. * The weight value is indicative

The zeroing and the zero of the system are connected to the situation of the
machine in the moment that it is carried out. Therefore the conditions of the terrain,
temperature and mechanical solicitations are influent.
If the machine is moving on a slope or is subjected to different mechanical or
temperature conditions, it is not necessary said that at equal loads you have the
same visualization.
A visualization of 0 Kg carried out on a flat surface could be different that made on
a slope.

PARTIAL WEIGHINGS

a) By pushing the PARTIAL key the


weight that is visualized on the
display is zeroed (the value
previously visualized will be
memorized) therefore giving the
possibility to load/unload the
material by starting from a fixed
reference.

b) At the end of a load/upload another


partial weighing can be carried out
by restarting from point “a” or
visualize the total weight by pushing
the TOTAL key. * The weight value is indicative

61
Use INDICATOR DG500 RevA7

NET / GROSS MODE


Selected by password 444

ZEROING
a) Carry out the zeroing by pushing the

key
b) The message :
“Set Tare” will appear
keep pushing the ZERO key until the
message:
“Setting Ok !” is visualized.

c) The indicator will return to GROSS


WEIGHT.
After the zeroing of the system the
net and gross weight will coincide
and are equal to zero.

* the weight value is indicative

62
Use INDICATOR DG500 RevA7

NET/GROSS WEIGHT

a) In this mode the PARTIAL key is


used to memorize a tare. Push for 3
seconds and the following messages
will appear:

ENGLISH
PRESS FOR 3 SECOND
then
SETTING TARE OK
At this point the display will visualize
a zero weight and the one previously
seen will be added up to the gross
weight.

With the TOTAL key the alternate


visualization of the NET WEIGHT and
GROSS WEIGHT will be seen.
The net weight is the gross weight
minus the tare previously
memorized.

LOADING WITH ALARM (Available


in both the functioning modes.)

a) From the TOTAL WEIGHT mode push

the key until the message Set


ALARM -/+ is visualized on the lower
display.

b) Set the weight with the PLUS and


MINUS keys.

63
Use INDICATOR DG500 RevA7

c) Confirm the set weight by pushing


the PARTIAL key and proceed with
the load / unload phase.
The weight will be visualized
decreasingly on the display
independently from the fact that you
are loading or unloading.

When the programmed percentage


(SETTING MENU - PERCENTAGE ON
THE ALARM INTERVANTION) has been
reached, the alarm will start in an
intermittent way. At 100% the alarm will
change from intermittent to continuous
for the time set in the Setting Menu
(ALARM DELAY TIME).

d) At the end the indicator will pass


automatically on TOTAL weight or
GROSS WEIGHT.

UNLOADING WITH ALARM


Carry out the same procedure as
LOADING WITH ALARM. The device
automatically recognizes the unloading
phase.

If a load / unload with alarm has already


been set, and during a move the weight
varies, it can be restored by pushing
PARTIAL.
If the indicator is switched off with a set
load/unload alarm, however, this value * The alarm value is only indicative.
is suggested to the next process.

64
Use INDICATOR DG500 RevA7

TRANSFER DATA VIA USB Key (available only in some versions)

USB Port

ENGLISH
The USB port is available only in some part number. It allows to transfer data via
USB Key.

It is possible to connect or disconnect the USB Key at any time, without restarting
the indicator.

1 Connect the USB Key to the indicator


and, from TOTAL WEIGHT MODE, press

the key.
Select “USB KEY” then press the
ENTER key to confirm.

If the message “DT not enabled”


doesn’t appear, it is necessary to
enable it by entering the Configuration
Menu ( see PASSWORD 19: GENERAL
SYSTEM SETTINGS= CONFIGURATION
MENU, point 12 Recipe reading from
Memory Card).

65
Use INDICATOR DG500 RevA7

If the USB key is not connected, the


message “Please Wait” appears,
followed by the message “USB Error”.
The indicator returns to TOTAL
WEIGHT MODE.

EMPTY USB KEY

1 If the USB Key is empty, the message


“Please, Wait” followed by “card.bin
not found” appears.

2 The message “Reprogram the USB key


by the DTM” appears.

3 Next the message “Please, remove the


USB key and close the connector” will
appear on the screen. After that the
indicator creates a file card.bin on the
USB key and it goes back to TOTAL
WEIGHT MODE.

In this case it is essential to reprogram


the USB by the DTM.

66
Use INDICATOR DG500 RevA7

USB KEY NOT FORMATTED

1 If the USB Key is not formatted for this


type of indicator, the message “USB
key not Formatted!” appears.

ENGLISH
2 The message “Format USB Key?”
appears.
Press the ENTER key to confirm,
otherwise press the RESET key to
cancel the operation.

3 If you want to format the USB Key, the


message “Reprogram the USB key by
the DTM” appears.

4 Finally, the message


“Formatting…Please Wait” appears.

67
Use INDICATOR DG500 RevA7

PROGRAMMING DATA TRANSFER FROM PC (DTM)

1 Connect a USB Key to the PC and


program it with the DTM Software.

2 Connect again the USB key to the


indicator. Go to USB KEY Menu.

3 The message “Please, Wait” appears


on the screen followed by “No
executions to download” or
“Downloading Executions on the USB
key”

See next paragraph

4 The message “New programmation


available. COPY NEW DATA?” appears.

 Press the ENTER key in order to


replace all the programs
(Recipes/ Unloading Programs)
saved on the indicator with the
new ones saved on the USB key.
Copy and paste all the data from
the USB key to the memory of
the indicator.

68
Use INDICATOR DG500 RevA7

 Press the RESET key if you do


not want to delete all the
programs (Recipes/ Unloading
Programs) on the indicator.

ENGLISH
5 The indicator returns to TOAL WEIGHT
MODE.
SAVING EXECUTION DATA ON THE USB KEY

1 After the execution of recipes or


unloading programs, it is possible to
save the data entering in the “USB
KEY” menu.

If the message “Different Database: it is not possible to download the execution


data” appears on the screen, it is necessary to reprogram the USB key from the
PC/DTM.

If the message “Insufficient Memory” is shown, it is necessary to reprogram the


USB key from PC/DTM.

2 Press the ENTER key to confirm. The


message “Downloading Executions on
USB key” appears.

69
Use INDICATOR DG500 RevA7

If there aren’t any executions to


download the message “No Executions
to Download” appears.

3 The percentage of the download


appears.

Please wait the complete download


(100%)

4 The message “Executions


downloaded!” appears.

5 Finally the message “Please, remove


the USB key and close the connector”
will be shown.
The indicator goes back to TOTAL
WEIGHT MODE.

70
Use INDICATOR DG500 RevA7

SUPPLEMENTARY FUNCTIONS
BATTERY CHECK

By pushing simultaneously PARTIAL

ENGLISH
and TOTAL the battery voltage will be
visualized.

HOURS and MINUTES:


VISUALIZATION

By pushing key the date and


time are visualized.

PROGRAMMING

a) Turn on and when the message

PLEASE WAIT appears push


key and wait until this screen is
visualized.
b) By pushing the PLUS and MINUS keys
enter into the hour program menu and
set the desired value.

c) Confirm the value with the ENTER


key (the value will also be seen on
the upper display) afterward the
indicator will pass on to the next
parameters that are:
Minutes [0 – 59]
Day [1 – 31]
Month [1 - 12]
Year [0-99].

71
Use INDICATOR DG500 RevA7

Repeat the operation from point b) for


each parameter.

d) After the confirmation of the year


with the ENTER key, the message
PLEASE WAIT will appear and the
indicator will return to TOTAL
WEIGHT.

PRINT
a) In order to print the weight keep press
the BLOCK PRINT key for 3 seconds
as indicated by the message on the
display. The indicator will return to
TOTAL WEIGHT.

Verify that the printer is connected to


the indicator before performing this
operation.

a) During the manual function the actual weight value (TOTAL and/or PARTIAL)
can be printed, with date and time, by pressing the BLOCK PRINT key.
b) During the execution, the RECIPE or the UNLOADING PROGRAMS used will be
automatically printed at the end of the process. At the end of the recipe or
unloading program execution this will be automatically printed.
c) The RECIPE and UNLOADING PROGRAMS that are memorized on the weighing
system can be printed by pushing the BLOCK PRINT key at the end of each
program or for a simple visualization of the program that was memorized.
d) During the COMPONENT ACCUMULATION mode it is possible to print by
pressing the BLOCK KEY print.

72
Use INDICATOR DG500 RevA7

PROGRAM MANAGEMENT
HOW TO ENTER IN THE MAIN MENU TO MODIFY EACH SETTINGS
1
From the modality TOTAL WEIGHT press the key.

ENGLISH
The MAIN MENU contains the following voices:

2
Press the key in order to enter in Press the key in order to
the submenu. return to TOTAL WEIGHT.

EDITING MENU
HOW TO PROGRAM THE COMPONENTS
1 Enter in the EDITING MENU and select
COMPONENTS with the ENTER key.

2 Select the component name that has to be


set/modified with the PLUS and MINUS
keys from Component 1 to 48.
Push the ENTER key in order to enter into
the setting/modification of the selected
component.

73
Use INDICATOR DG500 RevA7

3 The blinking letter indicates that it is


possible to insert/change the name of the
component.
The complete list of characters will
appears (editing mould).
Press the ENTER key in order to move in
the characters table.
Use the RIGHT, LEFT, PLUS and MINUS
keys to select the desired characters.
Press ENTER in order to confirm the
character desired.

4 Press the TOTAL key in order to choose


the type of letter: capital letter, lower case
letter, number or sign.

5 Press the PARTIAL key in order to cancel


the letter in this way:
- If you are at the beginning of the
line, you delete the letter selected;
- If you are from the second letter
until the last letter, you delete the
previous letter of the letter selected.

Press the key OR the ENTER key


(for 3 sec) in order to save the name of
component.
The message “Changes Saved” appears.

Before to save, press the key if


you wish return back without change the
value.

dinamica generale® suggests to set all the components that will be used by
inserting the name.

74
Use INDICATOR DG500 RevA7

HOW TO PROGRAM THE RECIPES


1 Enter in the EDITING MENU and select
RECIPES with the ENTER key.

ENGLISH
2

If the recipe doesn’t exist the message


“There are no Recipe” appears.

3 Select the recipe number that has to be


set with the PLUS and MINUS keys from
Recipe 1 to 24.

4 If the recipe name doesn’t exist (Empty)


you could insert it.
Push the ENTER key in order to enter
into the setting of the recipe.

If the recipe name already exists you


could change it. The message “Modify
Name” appears. Press the ENTER key in
order to change it.

75
Use INDICATOR DG500 RevA7

5 The blinking letter indicates that it is


possible to insert/change the name of
the recipe.
The complete list of characters will
appears (editing mould).
Press the ENTER key in order to move in
the characters table.
Use the RIGHT, LEFT, PLUS and MINUS
keys to select the desired characters.
Press ENTER in order to confirm the
character desired.

6 Press the TOTAL key in order to choose


the type of letter: capital letter, lower
case letter, number or sign.

7 Press the PARTIAL key in order to


cancel the letter in this way:
- If you are at the beginning of the
line, you delete the letter selected;
- If you are from the second letter
until the last letter, you delete the
previous letter of the letter
selected.

8
Press the key OR the ENTER key
(for 3 sec) in order to save the name of
recipe and switch to the next step.

Before to save, push the key if


you do not wish to set the name of the
recipe but you want return back and
select another Recipe.

10 At this point, you can choose if the


recipe is by cows or by totals with the
PLUS and MINUS keys.

Press the ENTER key in order to confirm


your choice.

76
Use INDICATOR DG500 RevA7

a) If you choose RECIPE BY COWS you could pass automatically to mode where
you can set the animals number (see the next paragraph: How to set the animals
number).

ENGLISH
b) If you choose RECIPE BY TOTALS you
could set the components of the recipe.
Press the ENTER key in order to confirm
your choice.
Press the ENTER key in order to go in
the COMPONENT LIST.
Select the component with the PLUS and
MINUS keys.

Only in modify mode, push the PARTIAL key in order to delete the component.
The message “Confirm Deleting?” appears. Confirm with ENTER key.

11 Confirm with the ENTER key.

12 With the PLUS and MINUS keys set the


value of component and confirm it with
the ENTER key.

13

Repeat the operation of the points 11


and 12 for the other components but
without select the same components (in
this case the message Warning
appears).

77
Use INDICATOR DG500 RevA7

If the total amount of components exceeds the set value in the password 99,
after the error message (HHH), the indicator proposes the maximum number of
animals for which that limit will not be exceeded.

14

Press the key in order to


visualize the Total Programmed.

* The value is only indicative

15 Press the ENTER key in order to


continue and set the mixing time (value
expressed in minutes).

16 Press the ENTER key in order to confirm


and exit by the recipe.

17 It is always possible to exit from the


programming of the Recipe and return
back by pressing the RESET key; in this
case the message SAVE CHANGES?
appears.

78
Use INDICATOR DG500 RevA7

18 Do you wish to save the settings that were programmed?

ENGLISH
YES NO
If you wish to save the settings that were If you do not want to save the settings
programmed press the ENTER key. The previously programmed press the
indicator will visualize the message RESET key.
CHANGES SAVED and it will return back. The indicator, after visualizing the
message CHANGES LOST, will return
back.

dinamica generale® suggests to set all the recipes that will be used by
inserting the name.

HOW TO SET THE ANIMALS NUMBER


1 With the PLUS and MINUS keys set the
animals number until a maximum of
30000 animals.

Range: 1-30000

2 Confirm the set value by pushing


ENTER.

79
Use INDICATOR DG500 RevA7

3 Now, it is possible set the component.


Press the ENTER key in order to go in
the COMPONENT LIST.
Select the component with the PLUS and
MINUS keys.

Only in modify mode, push the PARTIAL key in order to delete the component.
The message “Confirm Deleting?” appears. Confirm with ENTER key.

4 Confirm with the ENTER key.

5 Set the value of component with the


PLUS and MINUS key.

6 Confirm the value with the ENTER key.

Repeat the operation of the points 4, 5 and 6 for set the other components.

If the total amount programmed exceeds the set value in the password 99, after
the error message (HHH), the indicator recalculates the single values of
components and proposes the max value that will coincide with the value of
password 99.

80
Use INDICATOR DG500 RevA7

Press the key in order to


visualize the Total Recipe.

ENGLISH
* The value is only indicative

9 Press the ENTER key in order to


continue and switch to Total
Programmed.

* The value is only indicative

10 Press the ENTER key in order to


continue and set the mixing time (value
expressed in minutes).

11 Confirm the end of the programming


with the ENTER key.
The indicator will return to EDIT
RECIPES.

81
Use INDICATOR DG500 RevA7

12 It is always possible to exit from the


programming of the Recipe and return
back by pressing the RESET key; in this
case the message SAVE CHANGES?
appears.

13 Do you wish to save the settings that were programmed?

YES NO
If you wish to save the settings that were If you do not want to save the settings
programmed press the ENTER key. The previously programmed press the
indicator will visualize the message RESET key.
CHANGES SAVED and it will return back. The indicator, after visualizing the
message CHANGES LOST, will return
back.

82
Use INDICATOR DG500 RevA7

HOW TO PROGRAM THE UNLOADING POINTS


1 Enter in the EDITING MENU and select
UNLOADING POINTS with the ENTER key.

ENGLISH
2 Select the Unloading Points name that has
to be set/modified with the PLUS and
MINUS keys from Unloading Points 1 to
18.
Push the ENTER key in order to enter into
the setting/modification of the selected
Unloading Points.

3 The blinking letter indicates that it is


possible to insert/change the name of the
unloading points.
The complete list of characters will
appears (editing mould).
Press the ENTER key in order to move in
the characters table.
Use the RIGHT, LEFT, PLUS and MINUS
keys to select the desired characters.
Press ENTER in order to confirm the
character desired.

4 Press the TOTAL key in order to choose


the type of letter: capital letter, lower case
letter, number or sign.

5 Press the PARTIAL key in order to cancel


the letter in this way:
- If you are at the beginning of the
line, you delete the letter selected;
- If you are from the second letter
until the last letter, you delete the
previous letter of the letter selected.

83
Use INDICATOR DG500 RevA7

Press the key OR the ENTER key


(for 3 sec) in order to save the name of the
unloading points.
The message “Changes Saved” appears.

Before to save, press the key if


you wish return back without change the
value.

dinamica generale® suggests to set all the Unloading Points that will be used
by inserting the name.

HOW TO PROGRAM THE UNLOADING PROGRAMS

1 Enter in the EDITING MENU and select


UNLOADING PROGRAMS with the
ENTER key up to 24 positions.

If the Unloading Programs don’t exist the


message “There are no Unloading
Programs” appears.

84
Use INDICATOR DG500 RevA7

2 Select the Unloading Program name that


has to be set with the PLUS and MINUS
keys from Unloading Program 1 to 24.

ENGLISH
If the Unloading Program name already
exists you could change it. The message
“Modify Name” appears. Press the
ENTER key in order to change it.

Push the PARTIAL key in order to delete the component. The message “Confirm
Deleting?” appears. Confirm with ENTER key.

3 Push the ENTER key to enter into the


setting of the Unloading Programs.

4 The blinking letter indicates that it is


possible to insert/change the name of
the unloading programs.
The complete list of characters will
appears (editing mould).
Press the ENTER key in order to move in
the characters table.
Use the RIGHT, LEFT, PLUS and MINUS
keys to select the desired characters.
Press ENTER in order to confirm the
character desired.

5 Press the TOTAL key in order to choose


the type of letter: capital letter, lower
case letter, number or sign.

6 Press the PARTIAL key in order to


cancel the letter in this way:
- If you are at the beginning of the
line, you delete the letter selected;
- If you are from the second letter
until the last letter, you delete the
previous letter of the letter selected.

Press the key OR the ENTER key


(for 3 sec) in order to save the name of
the Unloading Program and switch to the
next step: Definition of the Unloading
Points.

85
Use INDICATOR DG500 RevA7

Before to save, push the RESET key if


you do not wish to set the name of the
Unloading Programs but you want return
back and select another one.
dinamica generale® suggests to set all the Unloading Programs that will be
used by inserting the name.

9 Now, it is possible set the unloading


points.
Press the ENTER key in order to go in
the UNLOADING POINTS LIST.
With the PLUS and MINUS keys select
the Unloading Points by number up to a
maximum value of 18.

If in EDIT STRINGS the names of the


Unloading Points have been inserted
their name will be visualized, if not the
wording “Empty” will be seen.

Only in modify mode, push the PARTIAL key in order to delete the component.
The message “Confirm Deleting?” appears. Confirm with ENTER key.

10 Confirm by pressing the ENTER key.

11 Set the weight of the unloading point


with the PLUS and MINUS keys.

12 Confirm the value by pressing ENTER.

86
Use INDICATOR DG500 RevA7

13

Repeat the operation for all the 18


Unloading Points but without select the
same value (in this case the message

ENGLISH
Warning appears).

The maximum limit that can be set for


each Unloading Point is 15000 kg/lb.
The total amount for each program
cannot exceed the value of the password
99, which has a limit of 999999.
If during the programming of an
Unloading Point you exceed the
maximum limit of the program the
indicator will visualize an error message
(HHH) afterwards it will propose the
weight value for that Unloading Point for
which the program limit has not been
exceeded.

14 In this case, it is possible:


a) Accept that value and close the b) Program other Unloading Points,
program setting the following Unloading checking the weight of the Unloading
Point to zero. Points previously programmed so as
to remain inside the total limit of the
Unloading Program.

15

Press the key in order to


visualize the Total Programmed.

* The value is only indicative

87
Use INDICATOR DG500 RevA7

16 Confirm the end of the programming


with the ENTER key.
The indicator will return to EDIT U.
PROGRAMS.

17 It is always possible to exit from the


programming of the Unloading Point and
return to PROGRAM UNLOAD by
pressing the RESET key; in this case the
message SAVE CHANGES? appears.

18 Do you wish to save the settings that were programmed?

YES NO
If you wish to save the settings that were If you do not want to save the settings
programmed press the ENTER key. The previously programmed press the
indicator will visualize the message RESET key.
CHANGES SAVED and it will return to The indicator, after visualizing the
PROGRAM UNLOAD. message CHANGES LOST, will return
to PROGRAM UNLOAD.

88
Use INDICATOR DG500 RevA7

EXECUTIONS MENU
HOW TO CARRY OUT THE EXECUTION OF THE RECIPES
1 Enter in the EXECUTIONS MENU and
select RECIPE with the ENTER key in

ENGLISH
order to execute the recipe programmed.

It is possible enter in this menu also by

pressing key from the modality


TOTAL WEIGHT.

2 Select the recipe that is to be executed


with the PLUS and MINUS keys from
Recipe 1 to Recipe 24.

If the recipe has never been programmed


or the total is equal to zero, the message
“EMPTY” will appear. If you press ENTER,
in this case, the message “WARNING
Empty List” will appear.

4 Confirm with the ENTER key in order to go


into the program execution.

89
Use INDICATOR DG500 RevA7

5 On the basis of the programming by cows or by totals it is possible distinguish:

a) If the program is set by COWS, it is


possible to modify the number with
the PLUS and MINUS keys.

When the modified number of cows is confirmed, the indicator recalculates the
weight and checks that the total amount programmed does not exceed the value
set in parameters menu, which has the limit of 999999 kg/lb.

If the total amount programmed does exceed the set value in the password 99,
after the error message (HHH), the indicator proposes the maximum number of
animals for which that limit will not be exceeded.

Confirm with the ENTER key.

On the upper display the WEIGHT TO


LOAD is visualized. This value is not
changeable.

*The weight value is only indicative.


b) if the recipe is programmed by
totals, in other words the number of
animals is = 0, the WEIGHT TO
LOAD can be modified with the
PLUS and MINUS keys.

90
Use INDICATOR DG500 RevA7

When the new value is confirmed, the indicator checks that the total amount
programmed does not exceed the value set in parameters menu.

ENGLISH
If the total amount programmed exceeds the value set in the password 99, after the
error message (HHH), the indicator proposes the max value that will coincide with
the value of password 99.

6 Confirm with the ENTER key.

7 After the PLEASE WAIT message the


first component to load will appear.

8 The passage from one component to the


other can take place by pressing the
ENTER key or the PLUS key.
If you use the PLUS key in order to
switch to the next component without
loading anything, the same component
is proposed at the end of the loading of
all components.
The indicator proposes only the
remaining quantity to be loaded and not
all the theoretical quantity programmed
for that component.
Example: if you have programmed 100
kg but you load 40 kg and press the
PLUS key, at the end of the recipe the
component is proposed with 60 kg and
not 100 kg.

91
Use INDICATOR DG500 RevA7

Repeat for all the components until the


message TOTAL LOADED appears.

10 Confirm with the ENTER key, the


Executing Timer will start. It will go on
for the time that you have set in editing
phase of that recipe.
Example: when you have created the
recipe (see the paragraph HOW TO
PROGRAM THE RECIPES), you have set
a mix timer. This value corresponds to
the Executing Timer that appear in this
step.

11 At the end of the minutes the indicator


advise you with the acoustic alarm.

12 The indicator will return to TOTAL


WEIGHT / RECIPE / MENU (it depends of
the setting in the password 500).

92
Use INDICATOR DG500 RevA7

HOW TO CARRY OUT THE EXECUTION OF THE UNLOADING PROGRAM


1 Enter in the EXECUTIONS MENU and
select UNLOADING PROGRAM with the
ENTER key in order to execute the
Unloading Program programmed.

ENGLISH
It is possible enter in this menu also by

pressing key from the modality


TOTAL WEIGHT.

2 Select the Unloading Program that is to be


executed with the PLUS and MINUS keys
from Unloading Program 1 to Unloading
Program 24.

If the Unloading Program has never been


programmed or the total is equal to zero,
the message “EMPTY” will appear. If you
press ENTER, in this case, the message
“WARNING Empty List” will appear.

3 Confirm with the ENTER key to go into the


Unloading Program execution.

4 Press the PLUS and MINUS keys in order


to modify the weight to Unload.
In this situation is also possible to press
the TOTAL key in order to set the weight
actually loaded on the wagon; the system
will automatically update the total weight
to be unloaded with the value actually
loaded on the wagon.

When the modified Weight to Unload is


confirmed, the indicator recalculates the
weight to unload related to each
Unloading Program.

5 Confirm with the ENTER key.

93
Use INDICATOR DG500 RevA7

6 After the message PLEASE WAIT the first


Unloading Program will appear.

7 The Unloading Program has to be carried


out until the weight reaches zero.
The passage from one Unloading Program
to the other is automatic if in parameters
menu AUTO ADVANCE = 1 has been
selected.
If not then you have to press ENTER to
pass from one Unloading Program to the
other memorizing the unloaded value.

Repeat for all the Unloading Programs


until the message TOTAL UNLOADED is
visualized.

9 When the Unloading Program is complete


the indicator return to TOTAL WEIGHT.

NOTE:
HOW TO BLOCK THE WEIGHING

During the Unloading Program execution it


is possible to suspend the weighing by

pushing the key and resume


afterwards by pushing the same key. In
the moment that this operation resumes
the indicator recalls the weight that was
present at the time of the block.

dinamica generale® suggests to always


use this function when the mixer is
moving.

94
Use INDICATOR DG500 RevA7

MANUAL MANAGEMENT OF THE RECIPE/UNLOADING PROGRAMS WITH THE


ENTER KEY

It is also possible to pass from one


execution to the other by pressing the

ENGLISH
key; in this case the actual
unloaded value will be memorized that can
be the total of the amount programmed or
only a part.

*The value is only indicative.

MANAGEMENT OF THE RECIPE/UNLOADING PROGRAMS WITH PLUS AND MINUS


KEYS

When you pass from one execution to the


other with the PLUS and MINUS keys, no
weighing will be memorized.

If the PLUS key is pressed while setting


the last execution the indicator considers
the execution concluded and will return to
TOTAL WEIGHT.

HOW TO VISUALIZE THE TOTAL DURING THE EXECUTION

During an execution it is possible to


visualize the total weight loading during

the loading phase with the key.

The TOTAL WEIGHT condition in the case


of an unloading coincides with the total
weight unloaded at that moment.

In order to return to the unloading

execution press again.

95
Use INDICATOR DG500 RevA7

HOW TO RETRIEVE THE EXECUTION FOLLOWING THE TURNING OFF OF THE


INDICATOR

If during an execution the indicator is


turned off for power reasons or in any
other case the load can be retrieved.
Once the indicator is turned on the
message RESTORE LOAD/UNLOAD? will
be visualized on the lower display.

At this point it is possible to:

a) reset the execution that was interrupted

by pressing the key.


b) ignore the reset of the execution
therefore losing all the data by pressing

the key. The indicator will return to


TOTAL WEIGHT.

RESTORE MODE FOR THE PROGRAMMED VALUE

During the execution is possible to restore


the programmed weight for the single
components, pressing for 5 sec the key

* The weight value is only indicative.

96
Use INDICATOR DG500 RevA7

SETTINGS MENU
PARAMETERS SUBMENU

ENGLISH
All the parameters that you setting in
this menu are the same described on the
PASSWORD 19 SEQUENCE OF THE
SETTINGS = SETTINGS MENU.

CONTRAST SUBMENU

From the SETTINGS MENU:

a) Select the CONTRAST submenu and


confirm with the ENTER key;

b) Set the value with the PLUS and


MINUS keys;

c) Press ENTER key in order to confirm


the value.

97
Use INDICATOR DG500 RevA7

ACCUMULATION MENU
From the MAIN MENU, enter in the
ACCUMULATION MENU with the ENTER
key in order to manage the accumulations.

COMPONENT ACCUMULATION
It allows to visualize the list of each
components with the relative weight.

CLEAR COMPONENT
ACCUMULATION
It allows to delete all data of component
accumulation. Once press the ENTER key,
the messages “Memory Deleted” and “No
Accumulation” appears.

Press the RESET key if you don’t wish clear the datas.

98
Use INDICATOR DG500 RevA7

SERVICE MENU
From the MAIN MENU, enter in the
SERVICE MENU with the ENTER key in
order to check the status of system.

ENGLISH
1 DIAGNOSTIC SUBMENU
It allows checking all the functioning
hardware of the indicator (display, combo,
keyboard, date & time etc.)

2 NUMBER WORKING HOURS


It allows to visualize the last reset:
- Date & time of last reset;
- Total number of hours that the
indicator has been worked;
- Total number of hours relative to the
executions effected.

3 NUMBER OF OVERLOADS
It allows visualizing the number of
overloads with date, hour and value of
overload.

Press the RESET key in order to return to the main menu.

99
Use INDICATOR DG500 RevA7

SYMBOLS
CONVENZIONAL SYMBOLS

This manual adopts some conventional symbols in order to guide the user through
important instructions and warnings regarding especially the programming of the
system’s parameters and therefore it’s correct functioning.
Please pay attention to the following graphical messages:

Indicates explanatory and added


information.

Recommends the maximum attention.

Signals an operation that can be


repeated various times.

Highlights a double operative option.

Advises of suggestions to carry out.

Signals that the weight value on the


* display is only indicative since it is only
an example or it advises the presence of
notes.

100
Accessories INDICATOR DG500 RevA7

OPTIONAL ACCESSORIES
PRINTER

It records on a ticket the information about the weights loaded or about the recipes that have been saved on
the indicator (depending from the dinamica generale microcomputer), including the option to personalize the

ENGLISH
ticket. Possibility to print the strings in the languages that are available on the indicator.
 Possibility to define the customer’s headline, name, address, company title etc.
 Low cost maintenance.
 Print module with thermal impact.
 In accordance with EEC directives.
 It is connectable to every dinamica generale microcomputer.
 During manual working, it is possible to print the current weight value (TOTAL and/or PARTIAL) with date
and time by pressing the PRINT key.
 During the execution, the RECIPE or the UNLOADING PROGRAMS are automatically printed at the end
of the process.
 In order to advance of the paper by hand, press the Feed key on the printer panel.

WiNET™ MODEM

Compatible modem with all dinamica generale accessories and indicators, that is able to manage a wireless
network between several devices without any interference issues.
 Best control of the equipment with maximum profit and without cable.
 Possibility to use many accessories connected to the indicator through wire or wireless.
 Only with one radio control the operator can manage several indicators and accessories at a time.
 Working range 25 meters x 360°.
 Improved organization for big companies in which you are working with more than one vehicle.

CAB DISPLAY

Supplementary display with little dimensions, suggested using into the cabin of the self propelled machine
or with WIRELESS Connection on any kind of machine used for the mixer load.
 Weight reading up to 99.999 Kg / Pounds.
 Operating temperature: - 30 / + 65 °C (-22 / +150°F).
 Dimensions 160 x 80 x 60 mm (6 x 3 x 2 inches).
 IP65 protection.
 Red "diodes LED" display high efficiency 25 mm high.
 Display visibility: more than 10 meters (30 feet).
 Simple and direct connection to all indicators dinamica generale®.
 The display can be connected by wire or by radiofrequency (WINET™).
 Possibility of a series connection of more displays.

WEIGHT REPEATER
Weight Repeater Display for a perfect visibility in any position, with the possibility also of WIRELESS
Connection, and series connection.
 Weight reading up to 99.999 Kg / Pounds.
 Operating temperature: - 30 / + 65 °C (-22 / +150°F).
 Dimensions 275 x 124 x 87 mm (10 x 4 x 3 inches).
 IP68 protection.
 Red "diodes LED" display high efficiency 60 mm high.
 Display visibility over 30 meters (100 feet).
 Simple and direct connection to all indicators dinamica generale®.
 The display can be connected by wire or by radiofrequency (WINET™).
 Possibility of a series connection of more displays.

101
Accessories INDICATOR DG500 RevA7

XL DISPLAY

Very large led display used for the remote weight visualization and the operator messages.
It is especially indicated for very large machines to allow the operator a constant control of weight as well
as component name also at high distance.

 Weight reading up to 999.999 Kg / Pounds.


 Operating temperature: - 30 / + 65 °C (-22 / +150°F).
 Dimensions: 870 x 220 x 120 mm (34 x 8 x 4 inches).
 Red, Green and Yellow "diodes LED" display.
 IP65 protection.
 Display view: over 50 m (165 feet).
 Simple and direct connection to all microcomputers dinamica generale with the WiNETTM interface.
 Metal watertight case protected against radio frequency noises.
 Multilangu age management.
 Grap hic bar.

EXTRA DISPLAY

Led display used for the remote weight visualization and the operator messages.
It is especially indicated to allow the operator a constant control of weight as well as component name also
at high distance.

 Red, Green and Yellow "diodes LED" display.


 Metal watertight case protected against radio frequency noises.
 Simple and direct connection to all microcomputers dinamica generale with the WiNET™ interface.
 Connection to the indicator by wire.
 Number of display is unlimited and can be chosen based on specific customer request.
 The display can be connected in a multipoint link by cable serial connection.
 Multilangu age management.
 Grap hic bar.

Dina TEL 3

Remote Control with innovative design, able to control the indicator up to 25 meters. Thanks its LCD display
with intuitive softkeys, back light on the keyboard and fixing support, it is essential device to remote indicator
on the loader cabin.

 Operating temperature: - 30 / + 65 °C (-22 / +150°F).


 Dimensions: 190 x 160 x 70 mm.
 IP68 protection.
 Working range 25 meters (82 feet) x 360°(Available also version with range up to 100 meters (330 feet))
 Power supply: 9,5 – 32 Vdc
 Unique remote control for all the dinamica generale applications.
 Directly compatible with all indicators (no Top Scale).

102
Accessories INDICATOR DG500 RevA7

DTM™

Data exchange Computer-Indicator using Memory Card


DTM is a feeding management software developed with farmers in order to satisfy needs of farms. DTM is
the evolution of a feeding software management in a professional, user friendly and integrated solution for
farmers. All farm activities are controlled with a single innovative tool. An easy way to monitor and

ENGLISH
decrease costs and increase profits.

 Multi Language Interface and Setup, Contextual Help Online, Sw Upgrade via Internet.
 Ingredient definition with costs traceability, Diet/Recipe definition and feed distribution.
 Automatic Dry Matter adjustment of component (not available on every version of DTM).
 Programming of Components, Recipes, Groups, Unload Programs/Batch.
 Loading/Unloading History and detailed reports (not available on every version of DTM).
 Stock and costs management (not available on every version of DTM).
 Refused and Operators management (not available on every version of DTM).
 Historical data and detailed reports on NIR Analysis made by dg precisionFEEDING and AgriNIR™ (not
available on every version of DTM).

EASY CONTROL 2

Radio Frequency communication (WiNET™)


Remote control in order to command the indicator all the way up to 25 meters (82 feet). With the WiNETTM
Modem interface, the remote control can be used with all dinamica generale wireless accessories without
any interference: all devices talk together in the same network.

 IP66 protection
 Working range 25 meters (82 feet) x 360°
 Battery type AA 1,5 Volt.
 Autonomy 120 days (normal function).
 Possibility to use EASY CONTROL 2 with other accessories connected to the indicator by wire or
wireless with WINET™
 New features for zeroing and ID customer set.
 New ergonomic design for a better integration user hand – product, with soft rubber handling surface
 Backside battery house protected with a sliding cover, for a improved maintenance of the product
(battery change)
 Available also version Easy Control 2 PtoP (no other wireless accessory can be used with this version)

WEIGHT TRANSMITTER 2

Device for the use of the weighing system in the industrial process lines.
This module is connected to the indicators in order to transform the weight value in an analogical signal 4-20
mA, or 0-10 V for the communication between the weighing system and the industrial devices such as
inverter, PLC, etc.

 Analogic Output Voltage: 0 - 5 Vdc; 0 - 10 Vdc.


 Analogic Output Current: 0 - 20 mA; 4 - 20 mA.
 Power Supply: 10 - 32 Vdc (Voltage Output) and 20 - 32 Vdc (Current Output).
 Connection module PROFIBUS to DG-WT 2.
 Connection module PROFIBUS to PLC.
 Directly compatible with all indicators.

103
Accessories INDICATOR DG500 RevA7

CAN BUS Connector

The J1939 protocol available on the CAN BUS output is deeply described in a specific document, not part of
this manual. Please contact the Dinamica Generale Customer Service or R&D office for more information.

Cable color Signal HI-TECH Connector


Blue CAN H D
Purple CAN L J
Black GND F
Without CAN BUS terminator.

Activation of communication protocol J1939

You can enable this protocol through the password 689 but it is available only for some part number. It offers
the possibility to send the strings relating to the recipe name, components, unloading programs and
unloading points.

Below the parameters that you can manage:

- CANBus ADDRESS (0-255):


value relating to the protocol address that corresponds to
the device connected.
- TRANSMISSION FREQUENCY / ENABLE (Disabled-
100ms-200ms…1000ms):
value of transmission frequency.
- BROADCAS T TYPE:
0 - All PGNs in order to send all the data
1 - Weight Status in order to send only the weight value
2 - Exec. Data in order to send the components name,
recipe etc.

CAN BUS CABLE CONNECTIONS:


BLUE : CAN H
VIOLET : CAN L
BLACK : GROUND
Inside the indicator there isn’t the CAN BUS termination 120 ohm resistance.

104
Service INDICATOR DG500 RevA7

SEARCHING FOR FAULTS

MOTION ALARM

DISPLAY CAUSE SOLUTION

ENGLISH
Cause1 Solution1:
The signal that comes from the sensors Do the TARE.
presents sudden and important weight
DG500 changes.
Solution2:
Carry out the calibration with
Cause2 password 12 and then do the TARE.
A cable or load cell is not working
Solution3:
correctly.
Carry out the control procedure
described below.

DOES NOT TURN ON

DISPLAY CAUSE SOLUTION

Solution1:
Carefully verify the connection cable
that goes from the microcomputer to
the power supply.

Solution2:
Power does not reach the
microcomputer. Verify the efficiency of the power
OFF supply
(Minimum 9 Volts / 0.5 A).

Solution3:
Send the microcomputer to dinamica
generale® or to the nearest service
center

105
Service INDICATOR DG500 RevA7

OVERRANGE ALARM

DISPLAY CAUSE SOLUTION


Cause1
The microcomputer is not able to read Solution1:
the signal from the load cells: the Do the TARE.
connection cable is not working
correctly.

DG500
Solution2:
Cause2
Carry out the calibration with
A cable or a load cell is not working
password 12 and then do the TARE.
correctly.

Cause3 Solution3:
The signal that comes from the sensors Carry out the control procedure
is out of the valid “RANGE” (see described below.
password 99).

LOW BATTERY ALARM

DISPLAY CAUSE SOLUTION

Solution1:
Check the correct function of the
battery.

DG500
The power supply of the indicator goes
below the fixed value.

Solution2:
Check the CABLES that send the
power from the BATTERY to the
INDICATOR.

UNSTABLE WEIGHT
DISPLAY CAUSE SOLUTION

The weight continues to go The signal that comes from the sensor is
Carry out the control procedure
up and down by tens or disturbed: a cable or a load cell does not
described below.
hundreds kg work correctly.

106
Service INDICATOR DG500 RevA7

CHECK THE DAMAGED COMPONENTS

DEFINE THE TESTING PROCEDURE:

ENGLISH
DO YOU HAVE A DG
WEIGHT
SIMULATOR
979-0007? YES

NO

NO DO YOU HAVE A
SYSTEM WITH A
YES
JUNCTION BOX?

CARRY OUT CARRY OUT


PROCEDURE 4 PROCEDURE 3

CARRY OUT
PROCEDURE 2
NO DO YOU HAVE A
SYSTEM WITH A
JUNCTION BOX?

YES

CARRY OUT
PROCEDURE 1

107
Service INDICATOR DG500 RevA7

PROCEDURE 1 Ref. YES/YES

Check that the scale is working correctly

a) Turn off the indicator.


b) Disconnect the sensor cables that are found from the indicator to the junction box.
c) Connect the WEIGHT SIMULATOR (979-0007), with the switch on the “Var” (variable) position, to
the SENSOR connector of the indicator.
d) Turn on the indicator.
e) Do the TARE (for the execution see the indicator user’s manual).
f) The indicator has to be stable visualizing “0” kg.
g) Check that the scale is working correctly by turning the WEIGHT SIMULATOR (clock wise the
weight increases, counter clock wise it decreases).

RESULT CAUSE ACTION


Zero is stable and is working
The indicator is NOT damaged Proceed with the following tests
correctly
Zero is not stable or is not
The indicator is damaged. Contact the service center
working correctly

Check the correct functioning of the SENSOR CABLE and of the JUNCTION BOX
a) Turn off the indicator.
b) Open the JUNCTION BOX.
c) Disconnect the sensors leaving only connected the cable that goes to the indicator (SENSOR
CABLE).
d) On the place of one of the sensors connect the WEIGHT SIMULATOR (979-0007) with the
appropriate adapter.
e) Turn on the indicator.
f) Do the TARE (for the execution see the indicator user’s manual).
g) The indicator has to be stable visualizing “0” kg.
h) Check that the scale is working correctly by turning the WEIGHT SIMULATOR (clock wise the
weight increases, counter clock wise it decreases).

REPEAT THE TEST BY CONNECTING THE WEIGHT SIMULATOR TO EACH SENSOR.

108
Service INDICATOR DG500 RevA7

RESULT CAUSE ACTION


Zero is stable and is working Sensor cable and junction box
Proceed with the following tests
correctly are NOT damaged
Try to dry out the junction box
Functioning is not correct only
The junction box is damaged or and repeat the test, if the result
in a few connectors of the
is wet is always the same change the

ENGLISH
junction box
junction box.
Zero is not stable or functioning
is not correct in all of the The sensor cable is damaged Substitute the sensor cable
connectors of the junction box

Check the functioning of the SENSORS

a) Open the junction box.


b) Leave only a sensor and the cable (SENSOR CABLE) that goes to the indicator connected.
c) Do the TARE (for the execution see the indicator user’s manual).
d) The indicator has to be stable visualizing “0” kg.
e) Check the correct functioning by loading some weight on the sensor that is connected (the weight
that is loaded does not have to be correct but it has to be stable).

REPEAT THE TEST BY CONNECTING ONE AT A TIME EACH SENSOR.

RESULT CAUSE ACTION


Proceed with the following
Zero and stable weight The sensor is NOT damaged
sensor

Zero and non stable weight The sensor is damaged Contact the service center

109
Service INDICATOR DG500 RevA7

PROCEDURE 2 Ref. YES/NO

Check the functioning of the indicator

a) Turn off the indicator.


b) Disconnect all of the sensors.
c) Connect the WEIGHT SIMULATOR with the switch on the “Var” (variable) position and one of the
sensor connectors of the indicator.
d) Turn on the indicator.
e) Do the TARE (for the execution see the indicator user’s manual).
f) The indicator has to be stable visualizing “0” kg.
g) Check the correct functioning by loading some weight on the sensor that is connected (the weight
that is loaded does not have to be correct but it has to be stable).

REPEAT THE TEST BY CONNECTING THE WEIGHT SIMULATOR IN THE PLACE OF EACH SENSOR.

RESULT CAUSE ACTION


Zero is stable and the
functioning is correct in all the The indicator is NOT damaged Proceed with the following tests
sensors
Zero is not stable or the
functioning is not correct in one The indicator is damaged Contact the service center
or more connectors

Check the functioning of the SENSORS

a) Turn off the indicator.


b) Leave connected only one sensor to the indicator.
c) Turn on the indicator.
d) Do the TARE (for the execution see the indicator user’s manual).
e) The indicator has to be stable visualizing “0” kg.
f) Check the correct functioning by putting some weight on the sensor that is connected (the weight
that is loaded does not have to be correct but it has to be stable).
REPEAT THE TEST BY CONNECTING ONE AT A TIME EACH SENSOR.

RESULT CAUSE ACTION


Proceed with the following
Zero and weight are stable The sensor is NOT damaged
sensor
Proceed with the following
Zero and weight are not stable The sensor is damaged sensor.
Contact the service center

110
Service INDICATOR DG500 RevA7

PROCEDURE 3 Ref. NO / YES

Check the functioning of the SYSTEM and of the SENSORS

a) Turn off the indicator.

ENGLISH
b) Open the JUNCTION BOX.
c) Leave connected only one sensor and the cable that goes to the indicator (SENSOR CABLE).
d) Turn on the indicator.
e) Do the TARE (for the execution see the indicator user’s manual).
f) The indicator has to be stable visualizing “0” kg.
g) Check the correct functioning by putting some weight on the sensor that is connected (the weight
that is loaded does not have to be correct but it has to be stable).

REPEAT THE TEST BY CONNECTING ONE AT A TME EACH SENSOR IN THEIR ORIGINAL POSITIONS.

RESULT CAUSE ACTION


Zero and weight are stable in all Connect everything and retry as
The system works correctly
the connectors per in normal use
Connect a functioning sensor on
Zero and weight are NOT stable The box or the sensors
the “critical” connector, repeat
only on a few connectors in the connected to those connectors
the test and verify the following 2
junction box are damaged
lines
Even with a new sensor the Substitute the junction box and
The junction box is damaged
zero and weight are NOT stable repeat the test
With a new sensor the zero and The sensor that was previously
Contact the service center
weight are stable connected is damaged
Zero and weight are NOT stable Substitute the senor cable repeat
The sensor cable or indicator is
on all the connectors in the the test and verify the following
damaged
junction box line
Zero and weight are still NOT
The indicator is damaged Contact the service center
stable

111
Service INDICATOR DG500 RevA7

PROCEDURE 4 Ref. NO / NO

Verify the functioning of the SYSTEM and of the SENSORS

a) Turn off the indicator.


b) Leave connected only one sensor to the indicator.
c) Turn on the indicator.
d) Do the TARE (for the execution see the indicator user’s manual).
e) The indicator has to be stable visualizing “0” kg.
f) Check the correct functioning by putting some weight on the sensor that is connected (the weight
that is loaded does not have to be correct but it has to be stable).
REPEAT THE TEST BY CONNECTING ONE AT A TIME EACH SINGLE SENSOR TO THE SAME CONNECTOR.

RESULT CAUSE ACTION


Zero and weight of one sensor
The sensor is damaged Contact the service center
are NOT stable
Zero and weight of all the
sensors on the same connector The indicator is damaged Contact the service center
are NOT stable
Zero and weight are stable with
Repeat the test with another
all the sensors on the same None
connector of the indicator
connector
Zero and weight are stable with
Connect everything and retry as
all the sensors in all the The system works correctly
in normal use
connectors

ERROR CODES

List of errors that could be visualized. In order to unblock the indi cator, the operator can
push any button.

Error Code Description


Error 1 Broken button: a button on the keyboard is broken and therefore results in being unusable
Error 2 The data regarding the loading executions has NOT been saved on the Data Transfer
(memory card) but has been saved on the internal memory. Next time the scale is turned
on it will try to memorize them on the card.
Error 3 The data regarding the loading executions has NOT been saved neither on the Data
Transfer nor on the internal memory. There is no way to recuperate the loading executions
therefore the data will be lost.
Error 4 The data regarding the execution of a loading recipe results in being corrupt before being
saved on the Data Transfer. Nothing will be saved on the Data Transfer and therefore the
data will be lost definitively.
Error 5 The data regarding the execution of a loading recipe has NOT been saved on the Data
Transfer because the memory is not sufficient. The data has been in any case saved on
the internal memory. The operator can, when turning on the indicator the next time,
recuperate the data by using a card with sufficient memory.
Error 6 The data re garding the executio n of a loadin g re cipe has NO T be en saved o n the Data
Transfer BUT have been saved on the i nternal memory. Next time the indicato r is turn ed
on it will try to memorize them on the card.

112
Service INDICATOR DG500 RevA7

Error 7 The data re garding the executio n of the loading recipe has NOT been save d neither o n
the Data Tra nsfer nor o n the internal memory. The re is no way to recu perate the data
regarding this execution.
Error 8 The data re garding the executio n of an unloadi ng re cipe results i n being corru pt before
being saved on the Dat a Transfer. Nothing will be saved on the Data Transfer and
therefore the data will be lost definitively.
Error 9 The data re garding the executio n of an unloading program has NOT been saved on the
Data T ransfer BUT have been saved on the inte rnal memo ry. Next time the indicator i s

ENGLISH
turned on it will try to memorize them on the card.
Error 10 The data reg arding the ex ecution of an unloading program has NOT bee n saved neither
on the Data Tran sfer nor on the intern al memory. There i s no way to recup erate the data
regarding this execution.
Error 11 The data regarding the execution of an unloading program results in being corrupt before
being saved on the Data Transfer. Nothing will be saved on the Data Transfer and
therefore the data will be lost definitively.
Error 12 The data regarding the execution of an unloading program has NOT been saved on the
Data Transfer because the memory is not sufficient. The data has been in any case saved
on the internal memory. The operator can, when turning on the indicator the next time,
recuperate the data by using a card with sufficient memory.
Error 13 The data regarding the execution of a manual weighing has NOT been saved on the Data
Transfer BUT have been saved on the internal memory. Next time the indicator is turned
on it will try to memorize them on the card.
Error 14 The data regarding the execution of a manual weighing has NOT been saved neither on
the Data Transfer nor on the internal memory. There is no way to recuperate the data
regarding this execution.
Error 15 The data regarding the execution of a manual weighing results in being corrupt before
being saved on the Data Transfer. Nothing will be saved on the Data Transfer and
therefore the data will be lost definitively.
Error 16 The data regarding the execution of a manual weighing has NOT been saved on the Data
Transfer because the memory is not sufficient. The data has been in any case saved on
the internal memory. The operator can, when turning on the indicator the next time,
recuperate the data by using a card with sufficient memory.
Error 17 At the turning on of the indicator the recovery of the data regarding an execution saved on
the internal memory has failed
Error 18 The operator tried to carry out “Restore Load” after the turning on and off of the indicator
during a loading execution, but the block presents non valid data. The operator can in any
case go ahead with the interrupted execution but it will not be saved on the card.
Error 19 The operator tried to carry out “Restore Load” after the turning on and off of the indicator
during an unloading execution but the block present non valid data. The operator can in
any case go ahead with the interrupted execution but it will not be saved on the card.
CLOCK During the initialization phase the reading of the clock failed. The clock battery could be
ERROR ! drained. The indicator, a part from the message on the LCD display, will activate the siren.
After substituting the battery the right time has to be set and afterwards turn off and back
on the indicator. Once the indicator has been turned back on the error message will not be
seen.

113
Rules INDICATOR DG500 RevA7

DICHIARAZIONE DI CONFORMITA’ ‐ DECLARATION OF CONFORMITY 
KONFORMITÄTSERKLÄRUNG ‐ DÉCLARATION DE CONFORMITÉ ‐ DECLARACION DE 
CONFORMIDAD ‐ ДЕКЛАРАЦИЯ О СООТВЕТСТВИИ  
Nr 28/16 
IT  Il sottoscritto, designato a legale rappresentante della Dinamica Generale s.p.a. , via Mondadori 15, 
Poggio Rusco (MN) ‐ Italy, dichiara che i prodotti sottoelencati: 
EN  The undersigned, an authorised officer of Dinamica Generale s.p.a. , via Mondadori 15, Poggio Rusco 
(MN) ‐ Italy, hereby declares that the products listed hereunder: 
D  Der Unterzeichner, rechtlicher Vertreter der Dinamica Generale s.p.a. , via Mondadori 15, Poggio 
Rusco (MN) – Italy, erklärt, daß die nachstehend beschriebenen Produkte: 
FR   Je soussigné, représentant légal désigné de Dinamica Generale s.p.a. , via Mondadori 15, Poggio Rusco 
(MN) ‐ Italy, déclare que les produits énumérés ci‐après: 
ES  El suscrito, nombrado representante legal de la Dinamica Generale s.p.a. , via Mondadori 15, Poggio 
Rusco (MN) ‐ Italy, declara que los productos indicatos a continuación: 
RU  Нижеподписавшийся, являющийся законным представителем компании Dinamica Generale s.p.a., 
расположенной по адресу via Mondadori 15, Poggio Rusco (MN) – Italy, заявляет, что продукция 
ниже 

DG500
IT   Sono conformi a quanto prescritto dalle seguenti direttive:  
EN   Are in compliance with the following directives:     
 
2014/30/EU  
D  Mit den Vorschriften konform sind, die in den folgenden Richtlinien:    
FR   Sont conformes aux prescriptions des directives suivantes:    
ES   Respetan las prescripciones contenidas en las siguientes directivas: 
RU      Соответствует требованиям следующих директив: 
 
IT   E dalle seguenti norme:       Main Standards: 
     
EN   And with the following standards:      
EN ISO 14982 
D   Und Normen stehen:        
FR   Et aux normes ci‐apres:       EN 61326‐1 (2013‐01) 
ES   Y en las siguientes normas:  EN 61326‐2‐3 (2013‐01) 
RU      И следующих стандартов: 
 
 
  Test Methods: 
  EN 55011 (2009‐11) + A1 (2010) 
 
  EN 61000‐4‐2 (2009‐03) 
  EN 61000‐4‐3 (2006‐05) + A1 (2008) + A2 (2010) 
  EN 61000‐4‐4 (2012‐11) 
 
  EN 61000‐4‐5:2014‐08 
 
IT   E, in applicazione a quanto previsto dalle direttive citate, sono stati dotati di marcatura CE ed é stato predisposto un adeguato fascicolo 
tecnico presso la ns. sede. 
EN   And, pursuant of the above‐mentioned directives, the CE mark has been applied. Furthermore, adeguate technical file has been prepared and 
is available from our offices. 
D   Und daß sie in Übereinstimmung mit den Vorschriften der obengenannten Richtlinien mit dem CE‐Zeichen versehen sind und daß dafür ein 
angemessenes technisches Heft erstellt wurde, das bei uns in der Firma zur Verfügung steht. 
FR   En application des directives citées, ils portent la marque CE et un dossier technique est deposé auprès de notre siège. 
ES   Y, conforme con lo previsto en las citadas directivas, han recibido la marca CE. Existe asimismo un especifico prospecto técnico relativo 
disponible en nuestra sede. 
RU      И, в исполнении данных директив, был нанесен знак СЕ и соответствующее техническое досье было заведено в нашем офисе. 
 
 
Poggio Rusco, 21/04/2016                    Andrea GHIRALDI 
 

114
Rules INDICATOR DG500 RevA7

WARNINGS
The power cable has to be connected directly to the battery or to a regulated
power source.
! If this is not the case DG does not respond to any eventual damage to the

ENGLISH
microcomputer.

Disconnect the power cable from the microcomputer when the battery of the
machine is being charged.
! If this is not the case DG does not respond to any eventual damage to the
microcomputer.

Disconnect all the cables from the microcomputer before performing welding
operations on the machine.
! If this is not the case DG does not respond to any eventual damage to the
microcomputer.

In order to have a correct functioning, check that the battery always has a
! tension level above 10,5 Volt.

This marking on the product or on its packaging illustrates


that this product may not be disposed of with normal
! household waste.
You are responsible for disposal of this equipment in a
correct way and in according to local regulations.

Before clearing the mixer with a high pressure washer protect the device from
possible water seepage. Furthermore be very careful to not expose the sensors,
junction box, acoustic alarm, cables and other eventual optional accessories to
! direct water jets.

If the equipment needs to be cleaned, use a soft, damp, lint-free cloth. Never
use sprays, solvents, abrasives, or sharp or pointed objects that could damage
! the indicator

115
Rules INDICATOR DG500 RevA7

GUARANTEE
The supplier guarantees, for 24 months from the delivery date, the good quality of the materials used, the
excellent construction and the steady functioning of the instrument that has been manufactured and that
bears the trademark or the production serial number. During the guarantee period the supplier undertakes to
repair or replace, free supplier’s head office, faulty parts due to poor materials or faulty construction,
provided that such parts are delivered free port supplier’s head office.
Shortcomings and defects due to the incorrect use of instruments, inadequate maintenance, changes carried
out without the supplier’s approval and normal wear are not included in this guarantee.
Liability and compensations by the supplier due to direct or indirect damages to persons, objects or
production, even as a consequence of faulty functioning of the supplied instruments or of material or
construction defects, are not included in this guarantee.

NOTE:

dinamica generale® has the faculty to modify the content of this user’s manual due to hardware and software implementations in order
to improve the products and therefore guarantee the best service to their users.

116
Rules INDICATOR DG500 RevA7

ENGLISH
Congratulations Dear User!
You have chosen a dinamica generale®
product, a leading company in the development and production of
electronic weighing systems, automation systems and NIR solutions.
These systems bring a high technological level in every field of
application such as zoo technical, feeding, industrial and biomedical.
Year by year the international market recognizes the quality,
experience, reliability and most of all the innovative technology, as a
part of a highly developed and innovative know how. These are the
pillars of our work and according to these beliefs we are at your
service, providing you with a simple as well as new, precise and
professional product, which is going to make your job easier for many
years. This user’s manual intends to take you through the different
performances of the weighing system in the easiest way possible and
to show you some new functions as well. dinamica generale® did not
forget to provide you with even the most basic information: the
configuration, the use of different accessories at your disposal, the
service of “searching for faults” and the equipment’s safety rules, in
order to guarantee to our customers more and more support and
technical assistance for years to come.
Now there is nothing left for us to do but wish you a work well done!

The dinamica generale® team

117
ISO 14001:2004 ISO 13485:2012
Cod. 985-0093 Rev. A7