Smith Precision Products: Leader in Liquefied Gas Transfer Since 1938
Smith Precision Products: Leader in Liquefied Gas Transfer Since 1938
Smith Precision Products: Leader in Liquefied Gas Transfer Since 1938
BYPASS VALVES………………………………………………………………………………..…..30
Y-TYPE STRAINERS…………………………………………………………………………..…..32
COUPLINGS………………………………………………………………………………………….34
EXCHANGE PROGRAM………………………………………………………………………….36
LITERATURE………………………………………………………………………………………….36
DISTRIBUTORS………………………………………………………………………………….….36
Maximizing Engineering Potential
Conversion to Larger
Capacity Pump
Higher flow rates can easily be
accomplished with the addition of
one, two, or three secondary gear
housings, each with 50 GPM flow
capacity.
4
Balanced Loading Design
Inlet Outlet
Liquid first enters the inlet of the pump, shown as blue in the upper left corner of the pump main
housing. It is also directed within the pump to the bottom right port, also shown as blue through the
porting in the gear end housing.
As the drive gear in the center rotates in a counterclockwise direction, the low pressure blue liquid is
directed into the spaces between the gear teeth and transferred to the red ports, as shown. The
velocity of the liquid entering the gear teeth spaces is carefully matched with the speed of the gear set
to minimize changes in velocity and directional changes of the liquid, thus minimizing the pressure
drop in the pump. Gear pockets are designed to insure a pressure gradient is present around the
outside diameter of the idler gears to suppress cavitation and maximize the transfer rate of the pump.
It is the design and efficiency of the non-contacting side of the gear teeth (in the Red Zones) that
largely determines the ability of the pump to develop pressure. Permissible wear on the leading side
of the gear teeth does not compromise this performance characteristic of the Smith 3-gear pump. The
red ports are also integrated within the pump (high pressure).
It is important from a loading standpoint that the drive gear is exposed to a neutral load, eliminating
the necessity for another ball bearing to support the other end of the drive shaft (which would also
add another mechanical seal). Given that the schematic uses color to indicate pressure, the symmetric
colors surrounding the drive gear illustrate that the drive gear is balanced.
As high pressure develops in the red ports, liquid maintains velocity and flows out of the pump
through the outlet port shown as red in the upper right corner.
Secondary gear housings can be added to the main housing shown and are internally ported to match
those of the main housing. The addition of a secondary gear housing is not to boost the pressure
capability of the pump, but rather to increase the volumetric flow rate of the pump.
5
“It All Starts With the Seal”
Patented, Preassembled, Pre-tested Mechanical Seal in Every Pump
MC-2 series, ATC-2 series MC-3 series, ATC-3 series MC-4 series MC-5 series
50 GPM (190 LPM) 100 GPM (380 LPM) 150 GPM (570 LPM) 200 GPM (758 LPM)
• Each secondary housing increases the flow capacity by 50 GPM (190 liters/min)
• The mechanical shaft seal assembly is exactly the same, except the length of the drive
shaft is increased for each higher capacity pump model
7
Proper Pump Selection
What is the Liquid Service?
Although we supply our products for a variety of liquid services, not all of our pumps
are the same. Since every pump application is different, we add “special modifications”
to fit the customer’s needs.
Temperature Range/Viscosity?
The type of liquid, temperature, and viscosity are all important variables. When
ordering a pump, specify the temperature range so we can determine the viscosity of
the liquid service. General temperature limits are within -80°F to +400°F (-80°C to
+205°C).
Duty Cycle?
We must know for how long the pump will be typically operated to determine the best
possible product to fit your needs. For a pump operating more than 2 hours at one
time, we recommend our “NSSA” option and operating the motor at slower speeds.
Electrical Requirements?
Specify whether a pump only or complete assembly will be required (pump, motor,
coupling, coupling guard, base (if applicable)). For motor inquiries, specify voltage, Hz,
and 1 or 3 phase as well as type of enclosure.
8
Small Capacity Pumps
SQ-Series Pumps
Flow Rates of 2-13 GPM (7-50 LPM)
• Designed specifically for continuous
duty recirculation systems
• Larger mechanical seal provides
longer wear life
• Easily mounts directly to motor face
with feet; no base required
• Foot mount available upon request
• No lubrication/greasing ever
required
MODEL FLOW RATE PUMP PUMP USUAL SIZE MOTOR NPSHr
(Assume 0 psi/bar INLET OUTLET OF TANK
differential pressure) SIZE SIZE LIQUID
OUTLET
5 GPM (19 LPM) @ 1800 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.25 - 0.5 HP 6”
SQ-1 2.5 GPM (10 LPM) @ 900 RPM (0.19 - 0.37 kW)
MAX 1800 RPM
7 GPM (26 LPM) @ 1800 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.25 - 1 HP 6”
SQ-H 3.5 GPM (13 LPM) @ 900 RPM (0.19 - 0.75 kW)
MAX 1800 RPM
13 GPM (49 LPM) @ 1800 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.5 - 1.5 HP 6”
SQ-HH 6 GPM (23 LPM) @ 900 RPM (0.37 – 1.1 kW)
MAX 1800 RPM
13 GPM (49 LPM) @ 1200 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.5 - 1.5 HP 6”
SQ-HH8 10 GPM (38 LPM) @ 900 RPM (0.37 – 1.1 kW)
MAX 1200 RPM
For liquids between 1-110 cP, predicted pump output will be the
For other liquid services or for more information on predicted pump output, please
10 same as pump capacity chart on page 9. Actual pump output will
visit our pump performance calculator at smithpumps.com
be approximately 5-10% greater than predicted above.
Small Capacity Pumps
MC-1, GC-1 Series Pumps
Flow Rates of 2.5 – 5 GPM (9-19 LPM)
• Strongly recommended as having the
lowest long-run cost where heavy
duty and maximum performance are
required.
• Both pump models are easily mounted
directly to the motors with feet, no
base required.
• Foot mount is also available.
• Both pumps can be rotated upside
MC-1 PUMP down to accommodate pipework
inlet/outlet.
MODEL FLOW RATE PUMP PUMP USUAL MOTOR NPSHr
INLET OUTLET SIZE OF
(Assume 0 psi differential
SIZE SIZE TANK
pressure) LIQUID
OUTLET
For liquids between 1-110 cP, predicted pump output For other liquid services or for more information on predicted pump
will be the same as pump capacity chart on page 11. output, please visit our pump performance calculator at
Actual pump output will be approximately 5-10% smithpumps.com
greater than predicted above.
12
Medium Capacity Pumps
Flow Rates of 10-35 GPM (38-133 LPM)
13
Both MC-1044 & MC-1044H pumps are
Model Weight Weight
reversible for loading/unloading (Pump only) (Pump, base,
applications coupling, coupling
guard, motor)
IN OUT
MC-1044 45 lbs (21 kg) 190-230 lbs* (85-
105 kg)
IN OUT OUT IN MC-1044H 45 lbs (21 kg) 190-265 lbs* (85-
120 kg)
For liquids between 1-110 cP, predicted pump output For other liquid services or for more information on
will be the same as pump capacity chart on page 13. predicted pump output, please visit our pump
Actual pump output will be approximately 5-10% performance calculator at smithpumps.com or
greater than predicted above. contact us.
14
Medium Capacity Pumps
Flow Rates of 25-50 GPM (38-190 LPM)
• Developed for 50 Hz Countries, the MC-
2H has identical flow rate as the MC-2
(1800 RPM) when operated at 1500 RPM
• For increased pump longevity, operate a
“non-H” pump at 1500 RPM or lower
• Our “F” type pumps come with flanges
available in the threaded, butt-weld, or
socket-weld versions
• Reversible
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-2 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2- ½” 2-3” 3 – 5 HP 1 ft. NO
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
MC-2H 50 GPM (190 LPM) @ 1500 RPM 2- ½” 2- ½” 2-3” 3 – 5 HP 1 ft. NO
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM
MC-2F 50 GPM (190 LPM) @ 1800 RPM 2” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
MC-2HF 50 GPM (190 LPM) @ 1500 RPM 2” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM
For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 15. Actual pump output will pump output, please visit our pump performance calculator at
16 be approximately 5-10% greater than predicted above. smithpumps.com or contact us.
Medium Capacity Pumps
Flow Rates of 25-50 GPM (38-190 LPM)
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
ATC-2R 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
ATC-2RH 50 GPM (190 LPM) @ 1500 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM
ATC-2L 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
ATC-2LH 50 GPM (190 LPM) @ 1500 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM
For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 17. Actual pump output will pump output, please visit our pump performance calculator at
18 be approximately 5-10% greater than predicted above. smithpumps.com or contact us.
Medium Capacity Pumps
High Differential Pressure
MC-2Q Pump
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-2Q 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2- ½” 2-3” 7- ½” HP 1 ft. NO
MAX 1800 42 GPM (160 LPM) @ 1500 RPM (5.6 kW)
RPM
OUT IN
For liquids between 1-110 cP, predicted pump output will be the same as
pump chart above. Actual pump output will be approximately 5-10% greater MC-2Q pump external dimensions and weight same as
than predicted. For other liquid services or for more information on predicted
pump output, please visit our pump performance calculator at
MC-3 pump on page 21.
smithpumps.com or contact us.
19
Large Capacity Pumps
Flow Rates of 50 – 100 GPM (133 – 380 LPM)
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-3 100 GPM (380 LPM) @ 1800 RPM 2- ½” 2- ½” 3” 5- 7- ½” HP 1 ft. NO
MAX 1800 83 GPM (314 LPM) @ 1500 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 900 RPM
MC-3H 100 GPM (380 LPM) @ 1500 RPM 2- ½” 2- ½” 3” 5- 7- ½” HP 1 ft. NO
MAX 1500 80 GPM (303 LPM) @ 1200 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 750 RPM
MC-3F 100 GPM (380 LPM) @ 1800 RPM 2” 2” 3” 5- 7- ½” HP 1 ft. YES
MAX 1800 83 GPM (314 LPM) @ 1500 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 900 RPM
MC-3HF 100 GPM (380 LPM) @ 1500 RPM 2” 2” 3” 5- 7- ½” HP 1 ft. YES
MAX 1500 80 GPM (303 LPM) @ 1200 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 750 RPM
For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted pump
same as pump capacity chart on page 20. Actual pump output will output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 21
Large Capacity Pumps
Flow Rates of 50 – 100 GPM (190 – 380 LPM)
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
22
Threaded Flange Butt-Weld Flange Socket Weld Flange
ATC-3R, ATC-3RH ATC-3L, ATC-3LH
IN IN Model Weight Weight
(Pump (Pump, base,
only) coupling,
coupling guard,
motor)
OUT OUT OUT OUT
Clockwise Counterclockwise
* Weight varies depending on motor,
NOTE: ONE OUTLET MAY BE USED WITH BLIND contact factory for specific weight
FLANGE INSTALLED ON UNUSED OUTLET PORT.
(BLIND FLANGE IS SHIPPED WITH PUMP)
For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted pump
same as pump capacity chart on page 22. Actual pump output will output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 23
Large Capacity Pumps
Flow Rates of 75 – 150 GPM (284 – 568 LPM)
• Developed for 50 Hz Countries, the MC-
4H has identical flow rate as the MC-4
(1800 RPM) when operated at 1500 RPM
• For increased pump longevity, operate a
“non-H” pump at 1500 RPM or lower
• Inlet through the cover to eliminate
elbows
• Our “F” type pumps come with flanges
available in the threaded or welded
versions
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-4 150 GPM (568 LPM) @ 1800 RPM 4” 2- ½” 3” 7- ½ - 10 HP 1.5 ft. NO
MAX 1800 125 GPM (473 LPM) @ 1500 RPM (5.6 – 7.5 kW)
RPM 75 GPM (284 LPM) @ 900 RPM
MC-4F 150 GPM (568 LPM) @ 1800 RPM 4” 2” 3” 7- ½ - 10 HP 1.5 ft. YES
MAX 1800 125 GPM (473 LPM) @ 1500 RPM (5.6 – 7.5 kW)
RPM 75 GPM (284 LPM) @ 900 RPM
MC-4HF 150 GPM (568 LPM) @ 1500 RPM 4” 2” 3” 7- ½ - 10 HP 1.5 ft. YES
MAX 1500 120 GPM (454 LPM) @ 1200 RPM (5.6 – 7.5 kW)
RPM 75 GPM (284 LPM) @ 750 RPM
24
Threaded Flange Welded Flange
IN
Model Weight Weight
DO NOT USE (Pump only) (Pump, base,
THIS PORT coupling,
coupling guard,
motor)
For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 24. Actual pump output will pump output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 25
Large Capacity Pumps
Flow Rates of 100– 250 GPM (379 – 946 LPM)
• Ideal for high capacity bulk transfer
• For higher flow rates, specify our “Large”
gear option for 250 GPM
• For increased pump longevity, operate a
“non-H” pump at 1500 RPM or lower
• Inlet through the cover to eliminate
elbows
• Our “F” type pumps come with flanges
available in the threaded or welded
versions
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-5 200 GPM (757 LPM) @ 1800 RPM 4” 2- ½” 4”-6” 10 – 20 HP 2-3 ft. NO
MAX 1800 167 GPM (632 LPM) @ 1500 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 900 RPM
MC-5H 200 GPM (757 LPM) @ 1500 RPM 4” 2- ½” 4”-6” 10 – 20 HP 2-3 ft. NO
MAX 1500 160 GPM (606 LPM) @ 1200 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 750 RPM
MC-5F 200 GPM (757 LPM) @ 1800 RPM 4” 2” 4”-6” 10 – 20 HP 2-3 ft. YES
MAX 1800 167 GPM (632 LPM) @ 1500 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 900 RPM
MC-5HF 200 GPM (757 LPM) @ 1500 RPM 4” 2” 4”-6” 10 – 20 HP 2-3 ft. YES
MAX 1500 160 GPM (606 LPM) @ 1200 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 750 RPM
For liquids between 1-110 cP, predicted pump output will be the
For other liquid services or for more information on predicted
same as pump capacity chart on page 26. Actual pump output will
pump output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. For 250
GPM, specify our “Large” gear option.
smithpumps.com or contact us. 27
Low Rpm Truck Pumps
Flow Rates of 35– 100 GPM (379 – 946 LPM)
• Our low RPM truck pumps are designed
for operation by power take off or by
engine
• 4 Ports available for ease of pipework
installation (3 ports for TC-1044H)
• Can be mounted sideways or upside
down
• Available in flanged version
TC-2 • Reversible
PUMP PUMP USUAL SIZE FLANGE
MODEL FLOW RATE OF TANK
NPSHr
INLET OUTLET
(Assume 0 psi differential pressure) LIQUID
SIZE SIZE
OUTLET
For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 28. Actual pump output will pump output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 29
Smith Bypass Valves
• Smith bypass valves are chatter
free due to the unique guide-
piston design
• Adjustable settings from 30-125
psid (2 – 9 bar) over tank pressure
(higher settings available)
• Used for a wide array of liquids
• Superior materials for longest life
• Stainless steel guide piston and
spring for infinite cycles
• Incorporates unique flow plate to
evenly dissipate flow when valve
opens
• Designed for continuous flow
30
WW-Series Dimension Table
MODEL SIZE A B C
(FNPT
inches)
WW-120 ½X½ 1 -5/8” 5- 7/16” 1- ¾”
WW-340 ¾X¾ [42 mm] [138 mm] [44 mm]
INLET OUTLET
Heavy steel flange
Positioning groove
Perforated metal for screen
screen cage, seam
welded with wire mesh
screen inside, soldered
at both ends
¼” plugged hole
for installation of
High tensile steel blow off valve if
bolts with hex desired
32 heads
MODEL* INLET OUTLET A B C
*For LCO2 service, we recommend our stainless steel 80 mesh screen denoted with the letter “A” at the end
of the model number.
For other liquids such as LPG, we recommend our brass 40 mesh screen, which does not contain an “A” in
the model number.
For inquiries about screen size/type of liquid, please contact our engineering department.
33
Smith Flexible Drive Couplings
When ordering a coupling, specify pump model, diameter of motor shaft, and HP & RPM of motor. For
34 a Teflon insert, add the letter “T” to the end of the model number
Smith Pump Performance Formula
The Smith pump performance formula is the same formula used when deriving pump performance
curves. The performance formula, however, gives a very accurate representation of pump characteristics,
such as taking temperature into account. Since proper installation has a very important bearing on
performance of a positive displacement pump, our engineering department will gladly review a proposed
piping layout. Supply us with a complete drawing or detailed sketch showing size/length of inlet and
outlet lines, including any elbows, valves, tees, etc. The more information provided, the better we are
able to recommend the best piping installation possible.
𝑁𝑑
Formula 1: 𝑄𝑑 = 𝑄𝑟 − 𝐹𝑠 𝑃𝑑 Not a math person? Visit our pump
𝑁𝑟 performance calculator on our
website for quick and easy
8.5 (𝑁𝑑 )(𝑄𝑟 )
Formula 2: 𝐻𝑃 = × 10−4 × 10 + 𝑃𝑑 calculations
𝑁𝑟
TABLE A: Rated Transfer Capacities
𝑄𝑑 = 𝐴𝑐𝑡𝑢𝑎𝑙 𝑃𝑢𝑚𝑝 𝐹𝑙𝑜𝑤 𝑅𝑎𝑡𝑒 𝐺𝑃𝑀
𝑄𝑟 = 𝑅𝑎𝑡𝑒𝑑 𝐹𝑙𝑜𝑤 𝑅𝑎𝑡𝑒 (𝐺𝑃𝑀) Model Rated Flow Rated Shaft
𝑃𝑑 = 𝐷𝑖𝑓𝑓𝑒𝑟𝑒𝑛𝑡𝑖𝑎𝑙 𝑃𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑏𝑒𝑖𝑛𝑔 𝑝𝑢𝑚𝑝𝑒𝑑 𝑎𝑔𝑎𝑖𝑛𝑠𝑡 (𝑝𝑠𝑖) Rate Speed
𝐻𝑃 = 𝐻𝑜𝑟𝑠𝑒𝑝𝑜𝑤𝑒𝑟 𝑅𝑒𝑞𝑢𝑖𝑟𝑒𝑑 (𝑸𝒓 , GPM) (𝑵𝒓 , RPM)
𝑁𝑑 = 𝐴𝑐𝑡𝑢𝑎𝑙 𝐷𝑟𝑖𝑣𝑒 𝑆𝑝𝑒𝑒𝑑 𝑜𝑓 𝑃𝑢𝑚𝑝 𝑆ℎ𝑎𝑓𝑡 𝑅𝑃𝑀
𝑁𝑟 = 𝑅𝑎𝑡𝑒𝑑 𝑆𝑝𝑒𝑒𝑑 𝑜𝑓 𝑃𝑢𝑚𝑝 𝑓𝑜𝑢𝑛𝑑 𝑖𝑛 𝑇𝑎𝑏𝑙𝑒 𝐴 SQ-1, MC-1, GC-1 5 1800
𝐹𝑠 = 𝑆𝑙𝑖𝑝𝑝𝑎𝑔𝑒 𝐹𝑎𝑐𝑡𝑜𝑟, 𝑎 𝑡𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑒 𝑑𝑒𝑝𝑒𝑛𝑑𝑒𝑛𝑡 𝑣𝑖𝑠𝑐𝑜𝑠𝑖𝑡𝑦 𝑣𝑎𝑟𝑖𝑎𝑏𝑙𝑒 𝑓𝑜𝑢𝑛𝑑 𝑖𝑛 𝑇𝑎𝑏𝑙𝑒 𝐵
SQ-H 7 1800
• Note actual pump output may be 5-10% greater than SQ-HH 13 1800
predicted value, 𝑄𝑑 SQ-HH8 13 1200
• For liquids between 1 – 120 cP viscosity, assume
MC-1044 20 1800
slippage factor to be 0.
• For liquids greater than 120 cP, please contact our MC-1044H 35 1800
engineering department MC-2, MC-2F, 50 1800
• For other liquids between 0 – 1 cP besides those listed ATC-2L, ATC-2R
in TABLE B, see our slippage factor graph on our MC-2H, MC-2HF, 50 1500
website or contact us direct ATC-2LH, ATC-2RH
• For pumps operating over 2 hours continuously, the MC-3, MC-3F, 100 1800
motor shaft speed must be reduced to speeds between ATC-3L, ATC-3R
750-1200 RPM and our NSSA option must be specified MC-3H, MC-3HF, 100 1500
• Pumps using our medium sized gear option will ATC-3LH, ATC-3RH
increase the flow rate by 10%, large gears by 20% MC-4, MC-4F 150 1800
Anhydrous
0.0049 0.0045 0.0042 0.0038 0.0033 0.0030 0.0026
Ammonia
Literature
For more information regarding our products, please call our sales or
engineering department or visit our website at smithpumps.com.
Distributors
To find your local distributor, please contact us for more information.