PROPANE
BUTANE • HIGH VOLUME BULK TRANSFER
HYDROCARBONS
OIL • TRUCK DELIVERY
JET FUEL • ISO CONTAINERS
DIESEL • DISPENSER SYSTEMS
KEROSENE • RECIRCULATION SYSTEMS
GASOLINE BLENDS
• TEST CHAMBERS
LIQUIDS UP TO • PORTABLE UNITS
20,000 cP, 2-250 GPM
1299 LAWRENCE DRIVE
NEWBURY PARK, CA 91320 USA
WWW.SMITHPUMPS.COM

UL LISTED, EU COMPLIANT, ISO: 9001 CERTIFIED


No One has Provided Liquefied Gas
Pumps Longer than Smith

Smith Precision Products Company was started in 1938


by Reuben Stanley Smith and was the first company to
provide pumps specifically for liquefied gas transfer. As
a remarkable American inventor, Reuben focused on
quality and provided innovative designs that would
stand the test of time. He believed that when a
customer encountered a problem, qualities such as
understanding and compassion were important in
finding a satisfactory solution.

Reuben’s son, Lawrence, joined the company in 1945


and worked hard to uphold his father’s values and re-
engineer the original product line. By the end of the
1950s, the company developed a fairly complete
product line and became involved in overseas markets.
Severe duty service options were added in the 1960s,
with flexible drive couplings and Y-type strainers to First patent issued for a mechanical seal used in a
liquefied gas pump. Within seven years, most pumps
follow. were using mechanical seals.

Lawrence’s three sons joined the company


in the 1970s and continued to follow in the
family’s footsteps. They placed more
emphasis on customer service and
achieving top certifications. As a result, the
company put forward exceptional new
designs and major improvements to the
existing product line. Today, third and
fourth generation Smiths are striving to
improve and strengthen the company’s
Installation of the 4X pump, Rueben Smith’s first design, 1938 ability to provide an even better level of
service.
Our mission is to insure the continuation of a notable legacy–one built on Reuben’s
values of ethics, integrity, and compassion. If this simple philosophy is maintained,
the rest is relatively easy.
Table of Contents
PUMP DESIGN………………………………………………………………………………………..4

PUMP APPLICATIONS (LIQUID SERVICE, TEMPERATURE RANGE)……………7

DETERMINING PROPER PUMP SELECTION……………………………………………..8

SMALL CAPACITY PUMPS (0-13 GPM, 0-50 L/MIN)…………………………………9

MEDIUM CAPACITY PUMPS (20-50 GPM, 75-190 L/MIN)…………………....13

LARGE CAPACITY PUMPS (100-250 GPM, 380-945 L/MIN)……………….....20

HIGH DIFFERENTIAL PRESSURE PUMPS…………………………………….............19

TRUCK PUMPS OPERATED USING POWER TAKE OFF OR ENGINES……....28

BYPASS VALVES………………………………………………………………………………..…..30

Y-TYPE STRAINERS…………………………………………………………………………..…..32

COUPLINGS………………………………………………………………………………………….34

PUMP PERFORMANCE FORMULA…………………………………………………….….35

EXCHANGE PROGRAM………………………………………………………………………….36

LITERATURE………………………………………………………………………………………….36

DISTRIBUTORS………………………………………………………………………………….….36
Maximizing Engineering Potential

Carbon Graphite Journal


Bearings
These bearings support the
entire length of the drive shaft. Superseal Mechanical Shaft
Balanced Load Balanced loading eliminates the Seal Assembly
Configuration need for a duplicate ball bearing The Superseal assembly is built as a kit
Minimizes gear tooth contact and at the end of the drive shaft and onto the pump drive shaft. This allows
eliminates constant casing contact, a second mechanical seal for dynamic pressure test before
which generates heat. Allows for assembly into pump or when supplied as
smooth, non-pulsating flow and a separate component. The 3-piece seal
higher differential pressures allows for slow rotation of the
intermediary seal ring, greatly reducing
friction –associated wear.

Gear Set is Readily


Accessible
Without disrupting the No Service Ball Bearing
mechanical seal, the gear Our design eliminates the
set can be easily replaced requirement for periodic greasing

Conversion to Larger
Capacity Pump
Higher flow rates can easily be
accomplished with the addition of
one, two, or three secondary gear
housings, each with 50 GPM flow
capacity.

4
Balanced Loading Design

Low Pressure High Pressure Low Pressure

Inlet Outlet

High Pressure Low Pressure High Pressure

Main Housing Gear End Cover

Liquid first enters the inlet of the pump, shown as blue in the upper left corner of the pump main
housing. It is also directed within the pump to the bottom right port, also shown as blue through the
porting in the gear end housing.

As the drive gear in the center rotates in a counterclockwise direction, the low pressure blue liquid is
directed into the spaces between the gear teeth and transferred to the red ports, as shown. The
velocity of the liquid entering the gear teeth spaces is carefully matched with the speed of the gear set
to minimize changes in velocity and directional changes of the liquid, thus minimizing the pressure
drop in the pump. Gear pockets are designed to insure a pressure gradient is present around the
outside diameter of the idler gears to suppress cavitation and maximize the transfer rate of the pump.

It is the design and efficiency of the non-contacting side of the gear teeth (in the Red Zones) that
largely determines the ability of the pump to develop pressure. Permissible wear on the leading side
of the gear teeth does not compromise this performance characteristic of the Smith 3-gear pump. The
red ports are also integrated within the pump (high pressure).

It is important from a loading standpoint that the drive gear is exposed to a neutral load, eliminating
the necessity for another ball bearing to support the other end of the drive shaft (which would also
add another mechanical seal). Given that the schematic uses color to indicate pressure, the symmetric
colors surrounding the drive gear illustrate that the drive gear is balanced.

As high pressure develops in the red ports, liquid maintains velocity and flows out of the pump
through the outlet port shown as red in the upper right corner.

Secondary gear housings can be added to the main housing shown and are internally ported to match
those of the main housing. The addition of a secondary gear housing is not to boost the pressure
capability of the pump, but rather to increase the volumetric flow rate of the pump.

5
“It All Starts With the Seal”
Patented, Preassembled, Pre-tested Mechanical Seal in Every Pump

• Every mechanical seal is pre-assembled and pre-


tested before leaving the factory
• No lubrication is ever required
• Unique three-piece seal design allows intermediary
seal ring to see ½ the wear
• The SUPERSEAL™ option eliminates brittle carbon
graphite in favor of a self-repairing thermoplastic
intermediary seal ring that continually laps itself
while the pump is in operation
• No loose parts, no thumbprints on seal faces, easy
to remove and install
Ease of Installation

Old mechanical seal can be removed in the field in a matter


of minutes! No disassembly of the pump required!
6
Mainline Pump Design

MC-2 series, ATC-2 series MC-3 series, ATC-3 series MC-4 series MC-5 series
50 GPM (190 LPM) 100 GPM (380 LPM) 150 GPM (570 LPM) 200 GPM (758 LPM)

• Each secondary housing increases the flow capacity by 50 GPM (190 liters/min)

• Each secondary housing contains 1 drive gear, 2 idler gears

• The mechanical shaft seal assembly is exactly the same, except the length of the drive
shaft is increased for each higher capacity pump model

• Ease of changing pump models if necessary

Our Pumps Can Transfer a Wide Range of Fluids


Smith Precision Products Company can provide pumping solutions for a wide array of
liquids ranging in viscosities from Carbon Dioxide to Honey.

CARBON DIOXIDE FOR ALL OTHER LIQUIDS*


Temp Range: -40°F to + 15°F (-40°C to + -9°C) Temp Range: -80°F to +400°F (-80°C to +205°C)
Maximum Allowable Working Pressure: 500 psi (34 Inlet Pressure: 4 psiA to 400 psi (0.28 to 28 bar)
bar) Differential Pressure: For liquids under 1 cP viscosity,
Maximum Differential Pressure: 50 psi (4 bar) general maximum differential pressure range between 50-
125 psi (4-9 bar). For liquids greater than 1 cP, maximum
differential pressure (intermittent duty) up to 300 psi (21
ANHYDROUS AMMONIA bar).
Temp Range: -25°F TO +100°F (-32°C to +38°C) Capacity: 2 to 250 GPM (7 LPM – 945 LPM)
Maximum Allowable Working Pressure: 400 psi (28
bar) *General limitations, specifications will differ based on
Maximum Differential Pressure: 75 psi (5 bar) liquid service/viscosity; contact our engineering
department for further details
FREONS
Temp Range: -40°F TO +150°F (-40°C to 65°C) ** All pumps are built for their intended liquid service and
Maximum Allowable Working Pressure: 400 psi (28 cannot be interchanged due to differences in materials of
bar) construction. Never use a pump for a liquid service other
Maximum Differential Pressure: 125 psi (9 bar) than specified.

7
Proper Pump Selection
What is the Liquid Service?
Although we supply our products for a variety of liquid services, not all of our pumps
are the same. Since every pump application is different, we add “special modifications”
to fit the customer’s needs.

What is the Flow Rate Required?


Our available pump flow rate range is from 2 – 250 GPM. Since higher flow means less
time to fill, maximum flow capacity pumps are desirable. HOWEVER, this is limited by
the liquid outlet size of the tank as well as the inlet line size feeding the pump. See our
pump model pages for the minimum required liquid outlet size. For pump flow rate
prediction, see our pump performance curves under our pump models or visit our
pump performance formula on page 35.

What is the Inlet Pressure? Differential Pressure?


The higher the differential pressure across the pump, the lower the flow rate. The
differential pressure is largely determined by the pressure drop on the discharge side of
the pump. The maximum recommended differential pressure for a specific pump
model depends on the liquid service/viscosity of the liquid and the duty cycle. Contact
our engineering department if the differential pressure cannot be determined.

Temperature Range/Viscosity?
The type of liquid, temperature, and viscosity are all important variables. When
ordering a pump, specify the temperature range so we can determine the viscosity of
the liquid service. General temperature limits are within -80°F to +400°F (-80°C to
+205°C).

Duty Cycle?
We must know for how long the pump will be typically operated to determine the best
possible product to fit your needs. For a pump operating more than 2 hours at one
time, we recommend our “NSSA” option and operating the motor at slower speeds.

Electrical Requirements?
Specify whether a pump only or complete assembly will be required (pump, motor,
coupling, coupling guard, base (if applicable)). For motor inquiries, specify voltage, Hz,
and 1 or 3 phase as well as type of enclosure.
8
Small Capacity Pumps
SQ-Series Pumps
Flow Rates of 2-13 GPM (7-50 LPM)
• Designed specifically for continuous
duty recirculation systems
• Larger mechanical seal provides
longer wear life
• Easily mounts directly to motor face
with feet; no base required
• Foot mount available upon request
• No lubrication/greasing ever
required
MODEL FLOW RATE PUMP PUMP USUAL SIZE MOTOR NPSHr
(Assume 0 psi/bar INLET OUTLET OF TANK
differential pressure) SIZE SIZE LIQUID
OUTLET
5 GPM (19 LPM) @ 1800 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.25 - 0.5 HP 6”
SQ-1 2.5 GPM (10 LPM) @ 900 RPM (0.19 - 0.37 kW)
MAX 1800 RPM
7 GPM (26 LPM) @ 1800 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.25 - 1 HP 6”
SQ-H 3.5 GPM (13 LPM) @ 900 RPM (0.19 - 0.75 kW)
MAX 1800 RPM
13 GPM (49 LPM) @ 1800 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.5 - 1.5 HP 6”
SQ-HH 6 GPM (23 LPM) @ 900 RPM (0.37 – 1.1 kW)
MAX 1800 RPM
13 GPM (49 LPM) @ 1200 RPM ¾” OR 1” ¾” OR 1” ¾” – 1- ¼” 0.5 - 1.5 HP 6”
SQ-HH8 10 GPM (38 LPM) @ 900 RPM (0.37 – 1.1 kW)
MAX 1200 RPM

The SQ-series pumps are ideal for continuous


duty, broad temperature range applications as
well as variable viscosity liquids for recirculation
systems or test chambers. A non-adjustable
external bypass valve built into the cover, preset
at 90 psi (6.1 bar) over tank pressure, is standard.
For applications requiring higher than 90 psid,
this bypass valve is removed and an external
bypass valve is recommended. 110 psi (7.5 bar) Foot Mount Option
bypass valve setting is also available. 9
OUT

Model Weight Weight


(Pump only) (Pump, coupling,
IN motor)

ALL SQ MODELS 39-45 lbs 75-90 lbs


(17-21 kg) (34-40 kg)

* Weight varies depending on pump model and motor,


Counterclockwise contact factory for specific weight

For liquids between 1-110 cP, predicted pump output will be the
For other liquid services or for more information on predicted pump output, please
10 same as pump capacity chart on page 9. Actual pump output will
visit our pump performance calculator at smithpumps.com
be approximately 5-10% greater than predicted above.
Small Capacity Pumps
MC-1, GC-1 Series Pumps
Flow Rates of 2.5 – 5 GPM (9-19 LPM)
• Strongly recommended as having the
lowest long-run cost where heavy
duty and maximum performance are
required.
• Both pump models are easily mounted
directly to the motors with feet, no
base required.
• Foot mount is also available.
• Both pumps can be rotated upside
MC-1 PUMP down to accommodate pipework
inlet/outlet.
MODEL FLOW RATE PUMP PUMP USUAL MOTOR NPSHr
INLET OUTLET SIZE OF
(Assume 0 psi differential
SIZE SIZE TANK
pressure) LIQUID
OUTLET

MC-1 5 GPM (19 LPM) @ 1800 RPM ¾” ¾” ¾” 0.25 – 1 HP 6”


2.5 GPM (9 LPM) @ 900 RPM (0.19 – 0.75 kW)
MAX 1800
RPM

GC-1 5 GPM (19 LPM) @ 1800 RPM ¾” ¾” ¾” 0.25 – 1 HP 6”


2.5 GPM (9 LPM) @ 900 RPM (0.19 – 0.75 kW)
MAX 1800
RPM

The MC-1 contains an internal, adjustable bypass


relief valve set at 100 psid with maximum setting
of 110 psid.

The GC-1 contains an internal, permanently set


bypass valve at 100 psid. 150 psid option is also
available. The GC-1 mechanical seal is exposed
to inlet pressure only, extending shaft seal life.

External bypass valves are recommended.


GC-1 PUMP
11
MC-1 GC-1
Model Weight Weight
(Pump only) (Pump, coupling,
OUT IN IN OUT motor)

MC-1, GC-1 20 lbs 75 lbs


(9 kg) (34 kg)

* Weight varies depending on pump model and motor,


contact factory for specific weight
Counterclockwise Clockwise

For liquids between 1-110 cP, predicted pump output For other liquid services or for more information on predicted pump
will be the same as pump capacity chart on page 11. output, please visit our pump performance calculator at
Actual pump output will be approximately 5-10% smithpumps.com
greater than predicted above.
12
Medium Capacity Pumps
Flow Rates of 10-35 GPM (38-133 LPM)

• Ideal for small bulk transfer


applications or truck
loading/unloading
• Extra inlet in cover eliminates
elbows
• Reversible
• Two ¼” NPT ports in main housing
for pressure gauge or hydrostatic
relief valve
MODEL FLOW RATE PUMP PUMP USUAL SIZE MOTOR NPSHr
INLET OUTLET OF TANK
(Assume 0 psi differential
SIZE SIZE LIQUID
pressure) OUTLET

MC-1044 20 GPM (76 LPM) @ 1800 RPM 1- ½” 1- ½” 1- ½” - 2” 1.5 – 2 HP 1 ft.


MAX 1800 17 GPM (64 LPM) @ 1500 RPM (1.1 – 1.5 kW)
RPM 13 GPM (49 LPM) @ 1200 RPM
10 GPM (38 LPM) @ 900 RPM

MC-1044H 35 GPM (133 LPM) @ 1800 RPM 1- ½” 1- ½” 1- ½” – 2” 2– 3 HP 1 ft.


MAX 1800 29 GPM (110 LPM) @ 1500 RPM (1.5 – 2.2 kW)
RPM 23 GPM (87 LPM) @ 1200 RPM
18 GPM (68 LPM) @ 750 RPM

13
Both MC-1044 & MC-1044H pumps are
Model Weight Weight
reversible for loading/unloading (Pump only) (Pump, base,
applications coupling, coupling
guard, motor)
IN OUT
MC-1044 45 lbs (21 kg) 190-230 lbs* (85-
105 kg)
IN OUT OUT IN MC-1044H 45 lbs (21 kg) 190-265 lbs* (85-
120 kg)

* Weight varies depending on motor, contact


factory for specific weight
Counterclockwise Clockwise

For liquids between 1-110 cP, predicted pump output For other liquid services or for more information on
will be the same as pump capacity chart on page 13. predicted pump output, please visit our pump
Actual pump output will be approximately 5-10% performance calculator at smithpumps.com or
greater than predicted above. contact us.

14
Medium Capacity Pumps
Flow Rates of 25-50 GPM (38-190 LPM)
• Developed for 50 Hz Countries, the MC-
2H has identical flow rate as the MC-2
(1800 RPM) when operated at 1500 RPM
• For increased pump longevity, operate a
“non-H” pump at 1500 RPM or lower
• Our “F” type pumps come with flanges
available in the threaded, butt-weld, or
socket-weld versions
• Reversible

MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-2 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2- ½” 2-3” 3 – 5 HP 1 ft. NO
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
MC-2H 50 GPM (190 LPM) @ 1500 RPM 2- ½” 2- ½” 2-3” 3 – 5 HP 1 ft. NO
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM
MC-2F 50 GPM (190 LPM) @ 1800 RPM 2” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
MC-2HF 50 GPM (190 LPM) @ 1500 RPM 2” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM

Threaded Flange Butt-Weld Flange Socket Weld Flange


15
Model Weight Weight
(Pump only) (Pump, base,
coupling,
OUT IN IN OUT OUT coupling guard,
motor)
MC-2, MC-2H, 75 lbs (34 kg) 285-350 lbs*
MC-2F, MC-2HF (129-159 kg)

Clockwise Counterclockwise * Weight varies depending on motor, contact


factory for specific weight
MC-2/MC-2H pumps are reversible for loading/unloading
applications

For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 15. Actual pump output will pump output, please visit our pump performance calculator at
16 be approximately 5-10% greater than predicted above. smithpumps.com or contact us.
Medium Capacity Pumps
Flow Rates of 25-50 GPM (38-190 LPM)

• ATC pumps contain an extra port


on the inlet cover to eliminate
elbows in the pipework
• Flanges come standard in
threaded, butt-weld, or socket
weld versions
• Identical to MC-2 type pumps,
except extra port and flanges
come standard

MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
ATC-2R 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
ATC-2RH 50 GPM (190 LPM) @ 1500 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM
ATC-2L 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1800 42 GPM (159 LPM) @ 1500 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 900 RPM
ATC-2LH 50 GPM (190 LPM) @ 1500 RPM 2- ½” 2” 2-3” 3 – 5 HP 1 ft. YES
MAX 1500 40 GPM (151 LPM) @ 1200 RPM (2.2 – 3.7 kW)
RPM 25 GPM (38 LPM) @ 750 RPM

Threaded Flange Butt-Weld Flange Socket Weld Flange 17


ATC-2R, ATC-2RH ATC-2L, ATC-2LH
IN IN
Model Weight Weight
(Pump (Pump, base,
only) coupling,
OUT OUT OUT OUT coupling guard,
motor)

ATC-2L, ATC-2LH, 75 lbs 285-350 lbs*


ATC-2R, ATC-2RH (34 kg) (129-159 kg)
Clockwise Counterclockwise
NOTE: ONE OUTLET MAY BE USED WITH BLIND
* Weight varies depending on motor, contact factory
FLANGE INSTALLED ON UNUSED OUTLET PORT.
for specific weight
(BLIND FLANGE IS SHIPPED WITH PUMP)

For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 17. Actual pump output will pump output, please visit our pump performance calculator at
18 be approximately 5-10% greater than predicted above. smithpumps.com or contact us.
Medium Capacity Pumps
High Differential Pressure
MC-2Q Pump

• Capable of differential pressures


of up to 150 psi (over 10 bar) for
liquids under 1 cP such as CO2 or
LPG

• Unique helical gear design


provides higher differential
pressures and quieter operation

MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-2Q 50 GPM (190 LPM) @ 1800 RPM 2- ½” 2- ½” 2-3” 7- ½” HP 1 ft. NO
MAX 1800 42 GPM (160 LPM) @ 1500 RPM (5.6 kW)
RPM

OUT IN

Clockwise, not reversible

For liquids between 1-110 cP, predicted pump output will be the same as
pump chart above. Actual pump output will be approximately 5-10% greater MC-2Q pump external dimensions and weight same as
than predicted. For other liquid services or for more information on predicted
pump output, please visit our pump performance calculator at
MC-3 pump on page 21.
smithpumps.com or contact us.
19
Large Capacity Pumps
Flow Rates of 50 – 100 GPM (133 – 380 LPM)

• Ideal for loading/offloading


• For increased pump longevity,
operate a “non-H” pump at
1500 RPM or lower
• Our “F” type pumps come with
flanges available in the
threaded, butt-weld, or socket-
weld versions
• Reversible

MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-3 100 GPM (380 LPM) @ 1800 RPM 2- ½” 2- ½” 3” 5- 7- ½” HP 1 ft. NO
MAX 1800 83 GPM (314 LPM) @ 1500 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 900 RPM
MC-3H 100 GPM (380 LPM) @ 1500 RPM 2- ½” 2- ½” 3” 5- 7- ½” HP 1 ft. NO
MAX 1500 80 GPM (303 LPM) @ 1200 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 750 RPM
MC-3F 100 GPM (380 LPM) @ 1800 RPM 2” 2” 3” 5- 7- ½” HP 1 ft. YES
MAX 1800 83 GPM (314 LPM) @ 1500 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 900 RPM
MC-3HF 100 GPM (380 LPM) @ 1500 RPM 2” 2” 3” 5- 7- ½” HP 1 ft. YES
MAX 1500 80 GPM (303 LPM) @ 1200 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 750 RPM

20 Threaded Flange Butt-Weld Flange Socket Weld Flange


Model Weight Weight
(Pump (Pump, base,
only) coupling,
IN IN OUT coupling
OUT guard, motor)

MC-3, MC-3F, 100 lbs 350-400 lbs*


MC-3H, MC-3HF, (45 kg) (159-182 kg)
MC-2Q
Clockwise Counterclockwise
* Weight varies depending on motor, contact
For models MC-3, MC-3F, MC-3H, MC-3HF factory for specific weight

For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted pump
same as pump capacity chart on page 20. Actual pump output will output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 21
Large Capacity Pumps
Flow Rates of 50 – 100 GPM (190 – 380 LPM)

• ATC pumps contain an extra port


on the inlet cover to eliminate
extra elbows in pipework
• Flanges come standard in
threaded, butt-weld, or socket
weld versions
• Identical to MC-3 type pumps,
except extra port and flanges
come standard

MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET

ATC-3R 100 GPM (380 LPM) @ 1800 RPM 2- ½” 2” 3” 5- 7- ½” HP 1 ft. YES


MAX 1800 83 GPM (314 LPM) @ 1500 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 900 RPM

ATC-3RH 100 GPM (380 LPM) @ 1500 RPM 2- ½” 2” 3” 5- 7- ½” HP 1 ft. YES


MAX 1500 80 GPM (303 LPM) @ 1200 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 750 RPM

ATC-3L 100 GPM (380 LPM) @ 1800 RPM 2- ½” 2” 3” 5- 7- ½” HP 1 ft. YES


MAX 1800 83 GPM (314 LPM) @ 1500 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 900 RPM

ATC-3LH 100 GPM (380 LPM) @ 1500 RPM 2- ½” 2” 3” 5- 7- ½” HP 1 ft. YES


MAX 1500 80 GPM (303 LPM) @ 1200 RPM (3.7 – 5.6 kW)
RPM 50 GPM (190 LPM) @ 750 RPM

22
Threaded Flange Butt-Weld Flange Socket Weld Flange
ATC-3R, ATC-3RH ATC-3L, ATC-3LH
IN IN Model Weight Weight
(Pump (Pump, base,
only) coupling,
coupling guard,
motor)
OUT OUT OUT OUT

ATC-3L, ATC-3LH, 100 lbs 350-400 lbs*


ATC-3R, ATC-3RH (45 kg) (159-182 kg)

Clockwise Counterclockwise
* Weight varies depending on motor,
NOTE: ONE OUTLET MAY BE USED WITH BLIND contact factory for specific weight
FLANGE INSTALLED ON UNUSED OUTLET PORT.
(BLIND FLANGE IS SHIPPED WITH PUMP)

For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted pump
same as pump capacity chart on page 22. Actual pump output will output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 23
Large Capacity Pumps
Flow Rates of 75 – 150 GPM (284 – 568 LPM)
• Developed for 50 Hz Countries, the MC-
4H has identical flow rate as the MC-4
(1800 RPM) when operated at 1500 RPM
• For increased pump longevity, operate a
“non-H” pump at 1500 RPM or lower
• Inlet through the cover to eliminate
elbows
• Our “F” type pumps come with flanges
available in the threaded or welded
versions
MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-4 150 GPM (568 LPM) @ 1800 RPM 4” 2- ½” 3” 7- ½ - 10 HP 1.5 ft. NO
MAX 1800 125 GPM (473 LPM) @ 1500 RPM (5.6 – 7.5 kW)
RPM 75 GPM (284 LPM) @ 900 RPM

MC-4H 150 GPM (568 LPM) @ 1500 RPM 4” 2- ½” 3” 7- ½ - 10 HP 1.5 ft. NO


MAX 1500 120 GPM (454 LPM) @ 1200 RPM (5.6 – 7.5 kW)
RPM 75 GPM (284 LPM) @ 750 RPM

MC-4F 150 GPM (568 LPM) @ 1800 RPM 4” 2” 3” 7- ½ - 10 HP 1.5 ft. YES
MAX 1800 125 GPM (473 LPM) @ 1500 RPM (5.6 – 7.5 kW)
RPM 75 GPM (284 LPM) @ 900 RPM

MC-4HF 150 GPM (568 LPM) @ 1500 RPM 4” 2” 3” 7- ½ - 10 HP 1.5 ft. YES
MAX 1500 120 GPM (454 LPM) @ 1200 RPM (5.6 – 7.5 kW)
RPM 75 GPM (284 LPM) @ 750 RPM

24
Threaded Flange Welded Flange
IN
Model Weight Weight
DO NOT USE (Pump only) (Pump, base,
THIS PORT coupling,
coupling guard,
motor)

2-1/2” PLUG OUT MC-4, MC-4F, 135 lbs 450-500 lbs*


MC-4H, MC-4HF (62 kg) (204-227 kg)

NOT REVERSIBLE * Weight varies depending on motor, contact factory


for specific weight
Counterclockwise

For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 24. Actual pump output will pump output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 25
Large Capacity Pumps
Flow Rates of 100– 250 GPM (379 – 946 LPM)
• Ideal for high capacity bulk transfer
• For higher flow rates, specify our “Large”
gear option for 250 GPM
• For increased pump longevity, operate a
“non-H” pump at 1500 RPM or lower
• Inlet through the cover to eliminate
elbows
• Our “F” type pumps come with flanges
available in the threaded or welded
versions

MODEL FLOW RATE (Assume 0 psi PUMP PUMP USUAL MOTOR NPSHr FLANGE
differential pressure) INLET OUTLET SIZE OF
SIZE SIZE TANK
LIQUID
OUTLET
MC-5 200 GPM (757 LPM) @ 1800 RPM 4” 2- ½” 4”-6” 10 – 20 HP 2-3 ft. NO
MAX 1800 167 GPM (632 LPM) @ 1500 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 900 RPM
MC-5H 200 GPM (757 LPM) @ 1500 RPM 4” 2- ½” 4”-6” 10 – 20 HP 2-3 ft. NO
MAX 1500 160 GPM (606 LPM) @ 1200 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 750 RPM
MC-5F 200 GPM (757 LPM) @ 1800 RPM 4” 2” 4”-6” 10 – 20 HP 2-3 ft. YES
MAX 1800 167 GPM (632 LPM) @ 1500 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 900 RPM

MC-5HF 200 GPM (757 LPM) @ 1500 RPM 4” 2” 4”-6” 10 – 20 HP 2-3 ft. YES
MAX 1500 160 GPM (606 LPM) @ 1200 RPM (7.5 – 14.9 kW)
RPM 100 GPM (379 LPM) @ 750 RPM

Threaded Flange Welded Flange


26
IN

Model Weight Weight


DO NOT USE (Pump only) (Pump, base,
THIS PORT coupling,
coupling guard,
motor)

2-1/2” PLUG OUT MC-5, MC-5F, 170lbs 465-530 lbs*


MC-5H, MC-5HF (77 kg) (211-240 kg)

* Weight varies depending on motor, contact factory


Counterclockwise for specific weight

For liquids between 1-110 cP, predicted pump output will be the
For other liquid services or for more information on predicted
same as pump capacity chart on page 26. Actual pump output will
pump output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. For 250
GPM, specify our “Large” gear option.
smithpumps.com or contact us. 27
Low Rpm Truck Pumps
Flow Rates of 35– 100 GPM (379 – 946 LPM)
• Our low RPM truck pumps are designed
for operation by power take off or by
engine
• 4 Ports available for ease of pipework
installation (3 ports for TC-1044H)
• Can be mounted sideways or upside
down
• Available in flanged version
TC-2 • Reversible
PUMP PUMP USUAL SIZE FLANGE
MODEL FLOW RATE OF TANK
NPSHr
INLET OUTLET
(Assume 0 psi differential pressure) LIQUID
SIZE SIZE
OUTLET

TC-1044H 35 GPM (133 LPM) @ 900 RPM 1- ½” 1- ½” 1- ½” – 2” 1 ft. NO


MAX 900 RPM

TC-2 50 GPM (190 LPM) @ 500 RPM 2- ½” 2- ½” 2-3” 1 ft. NO


MAX 500 RPM

TC-2F 50 GPM (190 LPM) @ 500 RPM 2- ½” 2” 2-3” 1 ft. YES


MAX 500 RPM

TC-3 100 GPM (380 LPM) @ 500 RPM 2- ½” 2- ½” 3” 1 ft. NO


MAX 500 RPM

TC-3F 100 GPM (380 LPM) @ 500 RPM 2- ½” 2” 3” 1 ft. YES


MAX 500 RPM

TC-3 Threaded Housing TC-3F Threaded Flange TC-3F Butt-Weld Flange


28
IN OUT
Model Weight
(Pump only)
OUT OUT OUT IN IN IN
TC-1044H 50 lbs
(23 kg)

TC-2, TC-2F 100 lbs


(45 kg)

Clockwise Counterclockwise TC-3, TC-3F 135 lbs


NOTE: ONE OUTLET MAY BE USED WITH 2 BLIND (62 kg)
FLANGES INSTALLED ON UNUSED OUTLET PORTS. * Weight varies depending on motor, contact factory
THE TC-1044H DOES NOT CONTAIN A TOP PORT. for specific weight

For liquids between 1-110 cP, predicted pump output will be the For other liquid services or for more information on predicted
same as pump capacity chart on page 28. Actual pump output will pump output, please visit our pump performance calculator at
be approximately 5-10% greater than predicted above. smithpumps.com or contact us. 29
Smith Bypass Valves
• Smith bypass valves are chatter
free due to the unique guide-
piston design
• Adjustable settings from 30-125
psid (2 – 9 bar) over tank pressure
(higher settings available)
• Used for a wide array of liquids
• Superior materials for longest life
• Stainless steel guide piston and
spring for infinite cycles
• Incorporates unique flow plate to
evenly dissipate flow when valve
opens
• Designed for continuous flow

MODEL SIZE PUMP RECOMMENDED FLOW


(FNPT)
WW-120 ½X½ SQ-1, SQ-H, MC-1, GC-1 2-10 GPM
(8-38 LPM)
WW-340 ¾X¾ SQ-HH, SQ-HH8 10-15 GPM
(38-57 LPM)
WW-100 1X1 MC-1044, MC-1044H, TC-1044H 15-35 GPM
(57-132 LPM)
WW-114 1- ¼ X 1- ¼ MC-2, MC-2H, MC-2Q, ATC-2R, 35-50 GPM
ATC-2RH, ATC-2L, ATC-2LH, TC-2 (132 – 189 LPM)

WW-112 1- ½ X 1- ½ MC-3, MC-3H, ATC-3R, ATC-3RH, 50-100 GPM


ATC-3L, ATC-3LH, TC-3 (189-379 LPM)
WW-200 2X2 MC-4, MC-4H 100-150 GPM
(379- 568 LPM)
WW-212 2- ½ X 2- ½ MC-5, MC-5H 150-250 GPM
(568 – 946 LPM)

30
WW-Series Dimension Table

MODEL SIZE A B C
(FNPT
inches)
WW-120 ½X½ 1 -5/8” 5- 7/16” 1- ¾”
WW-340 ¾X¾ [42 mm] [138 mm] [44 mm]

WW-100 1X1 1 – 7/8” 5- 5/8” 2- 5/8”


WW-114 1- ¼ X 1- ¼ [48mm] [143 mm] [67 mm]
WW-112 1- ½ X 1- ½
WW-200 2X2 3” 6-1/8 3- ¼
WW-212 2- ½ X 2- ½ [76 mm] [156 mm] [83 mm]

Typical Bypass Valve Installation

• Bypass valve should always


direct liquid back to the top
or vapor phase of the supply
tank
31
Smith Y-Type Strainers

• Only strainer designed specifically for liquefied gases


• Oversized design allows for minimal pressure drop
• Removable screen provides ease of maintenance
• Ductile iron construction
• 600 psi (40 bar) working pressure
• ¾” to 3” and combination sizes available
• Screens available in brass 40 mesh or 300- series stainless steel 80
mesh Strainer body
constructed of
ductile iron, 600 Narrow guide
psi working vane does not
Big Hex for easy Accurate, lathe-
pressure restrict flow
wrenching cut pipe
threads, no leak
problems

INLET OUTLET
Heavy steel flange

Positioning groove
Perforated metal for screen
screen cage, seam
welded with wire mesh
screen inside, soldered
at both ends
¼” plugged hole
for installation of
High tensile steel blow off valve if
bolts with hex desired
32 heads
MODEL* INLET OUTLET A B C

W-1-034-034A ¾” ¾” 6- 3/8” [162mm] 7” [178 mm] 4- ½“ [114 mm]


W-1-100-034A 1” ¾” 6- 3/8” [162mm] 7” [178 mm] 4- ½“ [114 mm]
W-1-100-100A 1” 1” 6- 3/8” [162mm] 7” [178 mm] 4- ½“ [114 mm]
W-1-114-034A 1- ¼” ¾” 6- 3/8” [162mm] 7” [178 mm] 4- ½“ [114 mm]
W-1-114-100A 1- ¼” 1” 6- 3/8” [162mm] 7” [178 mm] 4- ½“ [114 mm]
W-1-114-114A 1- ¼” 1- ¼” 6- 3/8” [162mm] 7” [178 mm] 4- ½“ [114 mm]
W-2-112-112A 1- ½” 1- ½” 8- 3/16” [208 mm] 9” [229 mm] 6-5/8” [169 mm]
W-2-200-112A 2” 1- ½” 8- 3/16” [208 mm] 9” [229 mm] 6-5/8” [169 mm]
W-2-200-200A 2” 2” 10- ¼” [260 mm] 11- ¼” [286 mm] 7- ½” [191 mm]
W-3-212-212A 2- ½” 2- ½” 10- ¼” [260 mm] 11- ¼” [286 mm] 7- ½” [191 mm]
W-3-300-212A 3” 2- ½” 10- ¼” [260 mm] 11- ¼” [286 mm] 7- ½” [191 mm]
W-3-300-300A 3” 3” 10- ¼” [260 mm] 11- ¼” [286 mm] 7- ½” [191 mm]

*For LCO2 service, we recommend our stainless steel 80 mesh screen denoted with the letter “A” at the end
of the model number.
For other liquids such as LPG, we recommend our brass 40 mesh screen, which does not contain an “A” in
the model number.
For inquiries about screen size/type of liquid, please contact our engineering department.

33
Smith Flexible Drive Couplings

• Machined in house to our own quality specifications


• High strength continuous-cast ferrous alloy
• Hardened steel set screw and drive pins
• High quality machining provides concentric bore diameters
• Balanced
• Flexible nitrile coupling insert (Teflon available for heavy duty applications)
HP OF RPM RECOMMENDED HP OF RPM RECOMMENDED
MOTOR COUPLING MODEL MOTOR COUPLING MODEL

¼ TO 1 1800 **VC-20 (FOR MC-1, 5 1800 VC-40


[0.18-0.75 kW] 1200 GC-1 PUMPS); [3.7 kW] 1200 VC-40
900 **VC-30 (FOR SQ-1, 900 VC-50
SQ-H, SQ-HH PUMPS)
7- ½ 1800 VC-40
[5.6 kW] 1200 VC-50
1- ½ 1800 VC-30 900 VC-50
[1.1 kW] 1200 VC-35 10 1800 VC-50
900 VC-35 [7.5 kW] 1200 VC-50
2 1800 VC-35 900 VC-50
[1.9 kW] 1200 VC-35 15 1800 VC-50
900 VC-40 [11.2 kW] 1200 VC-50
900 VC-50
3 1800 VC-35
[2.2 kW] 1200 VC-40 20 1800 VC-50
900 VC-40 [14.9 kW]

When ordering a coupling, specify pump model, diameter of motor shaft, and HP & RPM of motor. For
34 a Teflon insert, add the letter “T” to the end of the model number
Smith Pump Performance Formula
The Smith pump performance formula is the same formula used when deriving pump performance
curves. The performance formula, however, gives a very accurate representation of pump characteristics,
such as taking temperature into account. Since proper installation has a very important bearing on
performance of a positive displacement pump, our engineering department will gladly review a proposed
piping layout. Supply us with a complete drawing or detailed sketch showing size/length of inlet and
outlet lines, including any elbows, valves, tees, etc. The more information provided, the better we are
able to recommend the best piping installation possible.

𝑁𝑑
Formula 1: 𝑄𝑑 = 𝑄𝑟 − 𝐹𝑠 𝑃𝑑 Not a math person? Visit our pump
𝑁𝑟 performance calculator on our
website for quick and easy
8.5 (𝑁𝑑 )(𝑄𝑟 )
Formula 2: 𝐻𝑃 = × 10−4 × 10 + 𝑃𝑑 calculations
𝑁𝑟
TABLE A: Rated Transfer Capacities
𝑄𝑑 = 𝐴𝑐𝑡𝑢𝑎𝑙 𝑃𝑢𝑚𝑝 𝐹𝑙𝑜𝑤 𝑅𝑎𝑡𝑒 𝐺𝑃𝑀
𝑄𝑟 = 𝑅𝑎𝑡𝑒𝑑 𝐹𝑙𝑜𝑤 𝑅𝑎𝑡𝑒 (𝐺𝑃𝑀) Model Rated Flow Rated Shaft
𝑃𝑑 = 𝐷𝑖𝑓𝑓𝑒𝑟𝑒𝑛𝑡𝑖𝑎𝑙 𝑃𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑏𝑒𝑖𝑛𝑔 𝑝𝑢𝑚𝑝𝑒𝑑 𝑎𝑔𝑎𝑖𝑛𝑠𝑡 (𝑝𝑠𝑖) Rate Speed
𝐻𝑃 = 𝐻𝑜𝑟𝑠𝑒𝑝𝑜𝑤𝑒𝑟 𝑅𝑒𝑞𝑢𝑖𝑟𝑒𝑑 (𝑸𝒓 , GPM) (𝑵𝒓 , RPM)
𝑁𝑑 = 𝐴𝑐𝑡𝑢𝑎𝑙 𝐷𝑟𝑖𝑣𝑒 𝑆𝑝𝑒𝑒𝑑 𝑜𝑓 𝑃𝑢𝑚𝑝 𝑆ℎ𝑎𝑓𝑡 𝑅𝑃𝑀
𝑁𝑟 = 𝑅𝑎𝑡𝑒𝑑 𝑆𝑝𝑒𝑒𝑑 𝑜𝑓 𝑃𝑢𝑚𝑝 𝑓𝑜𝑢𝑛𝑑 𝑖𝑛 𝑇𝑎𝑏𝑙𝑒 𝐴 SQ-1, MC-1, GC-1 5 1800
𝐹𝑠 = 𝑆𝑙𝑖𝑝𝑝𝑎𝑔𝑒 𝐹𝑎𝑐𝑡𝑜𝑟, 𝑎 𝑡𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑒 𝑑𝑒𝑝𝑒𝑛𝑑𝑒𝑛𝑡 𝑣𝑖𝑠𝑐𝑜𝑠𝑖𝑡𝑦 𝑣𝑎𝑟𝑖𝑎𝑏𝑙𝑒 𝑓𝑜𝑢𝑛𝑑 𝑖𝑛 𝑇𝑎𝑏𝑙𝑒 𝐵
SQ-H 7 1800

• Note actual pump output may be 5-10% greater than SQ-HH 13 1800
predicted value, 𝑄𝑑 SQ-HH8 13 1200
• For liquids between 1 – 120 cP viscosity, assume
MC-1044 20 1800
slippage factor to be 0.
• For liquids greater than 120 cP, please contact our MC-1044H 35 1800
engineering department MC-2, MC-2F, 50 1800
• For other liquids between 0 – 1 cP besides those listed ATC-2L, ATC-2R
in TABLE B, see our slippage factor graph on our MC-2H, MC-2HF, 50 1500
website or contact us direct ATC-2LH, ATC-2RH
• For pumps operating over 2 hours continuously, the MC-3, MC-3F, 100 1800
motor shaft speed must be reduced to speeds between ATC-3L, ATC-3R
750-1200 RPM and our NSSA option must be specified MC-3H, MC-3HF, 100 1500
• Pumps using our medium sized gear option will ATC-3LH, ATC-3RH
increase the flow rate by 10%, large gears by 20% MC-4, MC-4F 150 1800

MC-4H, MC-4HF 150 1500

MC-5, MC-5F 200 1800

MC-5H, MC-5HF 200 1500


TABLE B: Slippage Factor, Fs
+100°F +80°F +60°F +40°F +20°F 0°F -20°F -40°F
[+38°C] [+27°C] [16°C] [4°C] [-7°C] [-18°C] [-29°C] [-40°C]

Carbon 0.0036 0.0032 0.0028 .0024


Dioxide

Anhydrous
0.0049 0.0045 0.0042 0.0038 0.0033 0.0030 0.0026
Ammonia

Propane 0.0033 0.0032 0.0031 0.0028

Butane 0.0042 0.0040 0.0038 0.0036 0.0034 0.0033 0.0032 35


Smith Exchange Pump Program
For many pump owners that do not want to remove the pump from
service for repairs, order an exchange pump. Once received, install the
exchange pump and send the old pump back to us for a generous credit.
All exchange pumps are backed by the same warranty provided for new
pumps.

The exchange program also applies to the mechanical seal. By returning


the old shaft seal assembly, you will receive a credit, that can be applied
towards future exchange shaft seal assemblies. It’s that simple.

Literature
For more information regarding our products, please call our sales or
engineering department or visit our website at smithpumps.com.

Distributors
To find your local distributor, please contact us for more information.

1299 LAWRENCE DRIVE


NEWBURY PARK, CA 91320 USA
WWW.SMITHPUMPS.COM
+1 (805) 498-6616

You might also like