Load Analysis Transverse
Load Analysis Transverse
Transverse
A. Roof
Beam AB, BC, CD, DE
SELF-WEIGHT
Weight of Beam (W30x447) 2.6037 KN/m
Load
Ceiling 0.48 KPa
For one-way slab For triangle slab
W =0.48(3 /2) W =0.48(3 /3)
W =0.72 KN / m W =0.48 KN /m
Beam AB
W =0.72(2)+ Self weight of beam
W =0.72(2)+ 2.6037
W =4.0437 KN /m
Beam BC
W =0.48+2.6037
W =3.0 8 37
Beam CD∧DE
W =0.72+Self weight of beam
W =0.72+2.6037
W =3.3237 KN /m
3rd floor
Beam AB, BC, CD, DE
SELF-WEIGHT
Weight of Beam (W30x447) 2.6037 KN/m
Load
Ceiling 0.48 KPa
Slab (0.15) 24(0.15)
Tiles 0.77 KPa
Plaster on tiles 0.24 KPa
5.09 KPa
For one-way slab For triangle slab
W =5.09(3/2) W =5.09(3/3)
W =7.635 KN /m W =5.09 KN /m
Beam FG
W =7.635(2)+ Self weight of beam
W =7.635(2)+ 2.6037
W =17.8737 KN /m
Beam GH
W =5.09+2.6037
W =7.6937 KN /m
Beam HI∧IJ
W =7.635+Self weight of beam
W =7.635+2.6037
W =10.2387 KN /m
2nd floor
Beam AB, BC, CD, DE
SELF-WEIGHT
Weight of Beam (W30x447) 2.6037 KN/m
Load
Ceiling 0.48 KPa
Slab (0.15) 24(0.15)
Tiles 0.77 KPa
Plaster on tiles 0.24 KPa
CHB ( 4 inch-thick) 2.73 KPa
7.82KPa
For one-way slab For triangle slab
W =7.82(3/2) W =7.82(3/3)
W =11.73 KN /m W =7.82 KN / m
Beam KL
W =11.73(2)+ Self weight of beam
W =11.73(2)+ 2.6037
W =26.0637 KN /m
Beam LM
W =7.82+ 2.6037
W =10.4237 KN /m
Beam MN∧NO
W =11.73+Self weight of beam
W =7.635+2.6037
W =14.3337 KN /m