0% found this document useful (0 votes)
113 views2 pages

BB MP: Key Features Technical Specification

This document provides specifications for the BB MP performance product line. It includes key features such as a start-up voltage between 10-56VDC that is set via CAN, idle mode power consumption under 300mW, voltage and current control on sides A and B from 10-56VDC with accuracy of ±0.05V and ±2A respectively, and short circuit protection. It also lists technical details including CAN interface speed, mechanical dimensions, connectors, and environmental specifications.

Uploaded by

Gustavo Cassares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views2 pages

BB MP: Key Features Technical Specification

This document provides specifications for the BB MP performance product line. It includes key features such as a start-up voltage between 10-56VDC that is set via CAN, idle mode power consumption under 300mW, voltage and current control on sides A and B from 10-56VDC with accuracy of ±0.05V and ±2A respectively, and short circuit protection. It also lists technical details including CAN interface speed, mechanical dimensions, connectors, and environmental specifications.

Uploaded by

Gustavo Cassares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PERFORMANCE PRODUCT LINE

BB MP
/

KEY FEATURES TECHNICAL SPECIFICATION


>
Control
>
Start-Up Voltage 10V to 56VDC (set by CAN)
> ON/OFF Tie to ground for start-up
> Inrush current limitation Not included
IDLE mode consumption <300mW
> Side A
> : Voltage 10V to 56VDC (set by CAN)
Voltage accuracy ±0.05V
Current limitation 240A
Current limit accuracy +/- 2A
Short circuit Current regulation at setpoint value down to 0V
Side B
Voltage 10V to 56VDC (set by CAN)
Voltage accuracy ±0.05V

Current limitation 240A

Current limit accuracy +/- 2A
Short circuit Current regulation at setpoint value down to 0V
Efficiency
> 97% for 45V -> 48V
Global efficiency
> 91% for 48V -> 12V
Environment
Environmental protection IP67, IP6K9K
Natural or forced convection
Cooling
Liquid cooling options available
Operating temperature range From -40°C to 80°C
Storage temperature range From -40°C to 100°C
Weight 1070g

BrightLoop Converters


+
www.brightloop.fr
BB MP CAN Interface
Bus speed selectable 1000 (default) / 500 / 250 / 125 Kbps
Current limit -240A to 240A, 0.5A resolution
Controls Voltage output setpoint 10V to 56V, 0.1V resolution
Power ON/OFF
DC/DC Status
Voltage and current
Feedback Internal auxiliary power supplies voltage
Internal temperatures
Internal protections
Software & Hardware revision
Identification
Bootloader for CAN software update
Mechanical
Dimensions 181x178x34mm
Housing Aluminum with conductive SurTec
Side A positive connector SLPIRBBPSR3 (Amphenol)
Side A GND connector SLPIRBBPSB1(Amphenol)
Side B positive connector SLPIRBBPSR2(Amphenol)
Side B GND Connector SLPIRBBPSB1(Amphenol)
Signals connector 8TA 008 35 SN (Souriau)
Mechanical fastening 4 holes, diameter 4,2mm
Fan fastening 4 holes, diameter M4