Det Tronics - X5200 UV IR HC
Det Tronics - X5200 UV IR HC
Det Tronics - X5200 UV IR HC
DESCRIPTION HIGHLIGHTS
The X5200 UVIR Flame Detector meets the ▲▲ Complies with FM 3260
Y E A R
3
most stringent requirements worldwide with ▲▲ EN54 certified
of vision. When both sensors simultaneously ▲▲ Responds to a fire in the presence of modulated blackbody
detect the presence of a flame, an alarm signal is generated. The radiation (i.e. heaters, ovens, turbines) without false alarm
detector has Division and Zone explosion-proof ratings and is ▲▲ HART models available
in addition to the three relays. A model with pulse output is resistance to moisture and ice
available for easy retrofitting into existing Det-Tronics controller ▲▲ Automatic, manual or magnetic o ® (optical integrity) testing —
i
based systems. Auxiliary relay and 0 to 20 mA output are not no external test lamp required
available with the pulse model. A tri-color LED on the detector ▲▲ Easily replaceable o plate
i
faceplate indicates normal condition and notifies personnel of fire ▲▲ Fire, fault and auxiliary relays standard
alarm or fault conditions.
▲▲ MODBUS RS-485 communication
The X5200 housing is available in aluminum or stainless steel, ▲▲ 0 to 20 mA isolated output (optional)
with NEMA 4X and IP66/IP67 rating. ▲▲ Pulse output for compatibility with controller based systems
(optional)
Typical applications include:
▲▲ A tri-color LED on the detector faceplate indicates normal
— Munitions
condition and notifies personnel of fire alarm or fault conditions
— Petrochemical applications
▲▲ Mounting arm allows easy sighting
— Turbines
▲▲ Integral wiring compartment for ease of installation
— Hangars
▲▲ Class A wiring per NFPA-72
17.5 watts @ 30 Vdc with EOL resistor installed and DEMKO 01 ATEX 132195X
Class I, Div. 1, Groups B, C & D (T5);
heater on maximum. Increased Safety Model
Class II, Div 1, Groups E, F & G (T5);
Relays Contacts rated 5 amperes at 30 Vdc. Class I, Div. 2 , Groups A, B, C & D (T3); II 2 G
Class II, Div 2. Groups F & G (T3); 0539 II 2 D
Fire Alarm: — Form C (NO and NC contacts) Class III. Ex d e IIC T6–T5 Gb
— normally de-energized Enclosure NEMA/Type 4X. Ex tb IIIC T80°C
— latching/non-latching. For FM Zone approval information, refer T6 (Tamb –50°C to +60°C)
Fault: — Form A (NO contacts) to the X5200 instruction manual (95-8546). T5 (Tamb –50°C to +75°C)
— normally energized IP66/IP67.
— latching/non-latching. Flameproof Model
Auxiliary*: — Form C (NO and NC contacts) II 2 G
0539 II 2 D
— normally energized
— latching/non-latching. IEC 61508 Ex d IIC T6–T5 Gb
Certified SIL 2 Capable Ex tb IIIC T80°C
Current Output* 0–20 mA (± 0.3 mA), with a maximum loop Applies to specific models – T6 (Tamb –55°C to +60°C)
(Optional) resistance of 500 ohms from 18–19.9 Vdc, Refer to the SIL 2 Certified T5 (Tamb –55°C to +75°C)
600 ohms from 20–30 Vdc. X5200 Safety Manual (95-8672). IP66/IP67.
*Auxiliary relay and 0 to 20 mA output are not available on pulse output model.