6110 (RTH) MKII Configuration 6110 (RTH) MKIl Configuration LCD Indicators LCD Description ‘Digital Input A Lit LCD Indicator 1 2 Common Warning Lit LCD Indicator 2 3 Common Shutdown Lit LCD Indicator 3 Miscellaneous Options Enable Fast Loading Feature No Enable Sleep Mode Yes Enable Manual Fue! Pump Control No Support Right-To-Left Languages in Module Strings No Event Log Display Options Module display Engine hours run Logging Options Log the following events to the event log Shutdown Alarms Yes Electrical Trip a a fame” No Waring Alarms Yes faintenance Alarms No Enable Crank Voltage Event Logging Activation Delay Ooms ‘Shutdowns Engine DTC Logging ony Data Logging Settings Only Log When Engine is Running Keep Oldest Data Configuration Logged data LogiInterval_ Trigger 1 second NotUsed 0 2 1 second NotUsed 0 about:blank Page | of 21 6110 (RTH) MKII Configuration Page 2 of 21 3 1 second NotUsed 0 4 1 second == NotUsed 0 about:blank 6110 (RTH) MKII Configuration External Trigger 1 Trigger 2 Trigger 3 Trigger 4 agers Not Used Not Used Not Used Not Used Polarity Polatity Polatity Polatity Energise Energise Energise Energise about:blank Page 3 of 21 6110 (RTH) MKII Configuration Logging Window Pre-Trigger Post-Trigger - 50% - Logging Window ation ECU (ECM) Options Engine Type Perkins ADEM4 Enhanced J1939 Yes Alternative Engine Speed No Protections Coolant Level Protection Override Disabled Inputs Inputs Inputs Analogue Input Configuration ECU (ECM) Options Module To Measure Oil Pressure No Module To Measure Coolant Temperature No Input Configuration ‘Analogue Input A Gill Sensor Analogue input 8 Temperature ‘Analogue Input C Fuel Sensor ‘Analogue Input D Flexible Analogue ‘Flexible Analogue’ selections are configured on the ‘Inputs/Analogue Inputs’ pages ‘Digital Input’ selections are configured on the ‘inputs/Digital Inputs’ pages CilTempetature/Fuel selections are configured on the ‘Engine’ pages Analogue Inputs Analogue Inputs ‘Analogue Inputs Flexible Sensor A The Analogue Input is not configured as a Flexible Sensor To reconfigure, use the ‘Analogue Input Configuration’ page Flexible Sensor B The Analogue Input is not configured as a Flexible Sensor To reconfigure, use the ‘Analogue Input Configuration’ page Flexible Sensor C The Analogue Input is not configured as a Flexible Sensor about:blank Page 4 of 21 6110 (RTH) MKII Configuration To reconfigure, use the ‘Analogue Input Configuration’ page Flexible Sensor D ‘Sensor Description Sensor Type Pressure Sensor Sensor Name Flexible Sensor Input Type Not used ‘Sensor Alarms Alarm Arming Always Low Alarm Enable Action None Low Alarm 1.03Bar, 14.94 PSI, 103 kPa Low Pre-alarm Enable Low Pre-alarm Trip 1.17Bar, 16.97 PSI, 117 kPa Low Pre-alarm Return 1.24Bar, 17.98 PSI, 124 kPa Low Alarm String High Pre-alarm Enable High Pre-alarm Return 1.40Bar, 20.30 PSI, 140 kPa High Pre-alarm Trip 1.50Bar, 21.75 PSI, 150 kPa High Alarm Enable Action None High Alarm 1 60Bar, 23.21 PSI, 160 kPa High Alarm String No No Flexible Sensor Low No No Flexible Sensor High about:blank Page 5 of 21 6110 (RTH) MKII Configuration Page 6 of 21 gital Inputs gital Inputs A - C Digital Input A Function Remote Start On Load Polarity Close to Activate Action Arming LCD Display Activation Delay Os Digital Input B Function Oil Pressure Switch Polarity Close to Activate Action Arming LCD Display Activation Delay Os Digital Input C Function Coolant Temperature Switch Polarity Close to Activate Action Arming LCD Display Activation Delay Os gital Inputs D - F Digital Input D Function User Configured Polarity Close to Activate Action Warning Arming Always: LCD Display low coolant level Activation Delay Os Digital Input E Function User Configured Polarity Close to Activate Action Shutdown Arming Never LCD Display Activation Delay Os Digital Input F Function User Configured Polarity Close to Activate Action Electrical Trip Arming Never about:blank 6110 (RTH) MKII Configuration LCD Display Activation Delay Os Analogue Inputs A - C Analogue Input A (Digital) The Analogue Input is not configured as a Digital Input To reconfigure, use the ‘Analogue Input Configuration’ page Analogue Input B (Digital) The Analogue Input is not configured as a Digital Input To reconfigure, use the ‘Analogue Input Configuration’ page Analogue Input C ( ital) The Analogue Input is not configured as a Digital Input To reconfigure, use the ‘Analogue Input Configuration’ page Analogue Input D Analogue Input D (Digital) The Analogue Input is not configured as a Digital Input To reconfigure, use the ‘Analogue Input Configuration’ page igital Outputs Output Configuration Source Polarity Output A Fuel Relay Energise Output B Start Relay Energise Output C Not Used Energise Output D Close Gen Output Energise Output E Digital Input A Energise Output F_ Common Warning Energise about:blank Page 7 of 21 6110 (RTH) MKII Configuration Timers Start Timers Start Timers Start Delay 5s Pre-heat Os Cranking 10s Cranking Rest 108 Smoke Limiting Os Smoke Limiting Off Os Safety On Delay 108 Warming ts Load/Stopping Timers Load Timers Breaker Close Pulse 05s Breaker Trip Pulse 05s Stopping Timers Return Delay 30s Cooling 1m ETS Solenoid Hold Os Failto Stop Delay 30s Module Timers Interface Timers LCD Page Timer 5m LCD Scroll Timer 5s about:blank Page 8 of 21 6110 (RTH) MKII Configuration Page 9 of 21 Generator Generator Options Generator Options Alternator Fitted Yes Poles 4 AC System 3 Phase, 4 Wire Generator Voltage Alarms Under Voltage Alarms Shutdown Yes Trip 351VPhPh 84.6% Activation Delay 208 Loading Voltage 381V PhPh 91.7% Nominal Voltage 415V PhPh Over Voltage Alarms Shutdown Trip 452VPhPh 108.8% Activation Delay 208 about:blank 6110 (RTH) MKII Configuration Page 10 of 21 Generator Frequency Alarms Under Frequency Alarms Shutdown Yes Trip 40.0Hz — 80.0% Activation Delay 208 Loading Frequency 45.0 Hz 90.0% Nominal Frequency 50.0 Hz Over Frequency Alarms Shutdown Yes Trip S7OHZ 114.0% Activation Delay 2.08 Overshoot Delay 20s about:blank 6110 (RTH) MKII Configuration Page 11 of 21 Generator Current Generator Current Options CT Primary (L1,L2.L3.N) 100A Full Load Rating 834A Overcurrent Alarm Immediate Warning Yes IDMT Alarm Yes Trip 110% 917 A Time Muttipier 1 Action Shutdown Generator Rating kW Rating 480kW Overload Protection Enable No Action Shutdown Trip 100% 480 kW Return 99% 475 kW Delay 5s about:blank 6110 (RTH) MKII Configuration Pressure Pressure Sensor Measured Quantity Resistive Input Type Notused Oil pressure is read from the ECU (ECM) Oil Sensor Open Circuit Alarm Enable Open Circuit jy_-—-Open circuit alarm applies to the ECU (ECM) Alarm’ reading Low Oil Pressure Shutdown Enable Enabled Trip 2.00Bar, 29.01 PSI, 200 kPa Coolant Temperature ‘Temperature Sensor Input Type Not used Engine temperature is read from the ECU (ECM) High Coolant Temperature Alarms Shutdown Trip 105 °C, 221 °F Fuel Level Input Type Not used ‘Sensor Alarms about:blank Page 12 of 21 6110 (RTH) MKII Configuration Low Alarm Enable No Action None Low Alarm 10% Delay Os Low Pre-alarm Enable No Low Pre-alarm Trip 25 % Low Pre-alarm Return 30 % Delay Os High Pre-alarm Enable No High Pre-alarm Return 65 % High Pre-alarm Trip 70 % Delay Os High Alarm Enable No Action None High Alarm 90 % Delay Os Fuel Pump Control Enable No On 25% Off 75% Tank Tank Size 1000 Units Litres Engine Options Engine Type Engine Type Perkins ADEM4 Startup Options Start Attempts 3 Loss of Sensing Signal Shutdown Gas Engine Timers Choke 2 GasonDelay 2: Ignition Off Delay 2: ‘Sensing Options Magnetic Pickup Fitted No Flywheel Teeth 190 ECU (ECM) Options about:blank Page 13 of 21 6110 (RTH) MKII Configuration ECU (ECM) Op' ns Module to Record Engine Hours Module To Use Engine Speed Disable ECM Speed Control No No Module To Use Charge Alt Voltage No No DPF Regeneration Control Enable Automatic ‘Speed Switch Enable Default Dataset ECU about:blank Page 14 of 21 6110 (RTH) MKII Configuration ECU (ECM) Alarms ECU (ECM) Data Fail ECU (ECM) Data Fail Action Shutdown Arming Engine Protection Activation Activation Delay Os DM1 Signals ECU Amber Action Warning Arming Always: Activation Delay Os ECU Red Action Shutdown Arming From Safety On Activation Delay Os ECU Malfunction Action Warning Arming Always: Activation Delay Os ECU Protect Action Warning Arming From Safety On Activation Delay Os ‘Advanced Water In Fuel Action Warning Arming Always: Activation Delay Os After Treatment Action Warning Arming From Safety On Activation Delay Os Crank Disconnect Options Crank Disconnect on Oil Pressure No Check Oil Pressure Prior to Starting No about:blank Crank Disconnect Generator Frequency 21.0 Hz Page 15 of 21 6110 (RTH) MKII Configuration Page 16 of 21 Engine Speed 600 RPM Oil Pressure 2.00Bar, 29.01 PSI, 200 kPa about:blank 6110 (RTH) MKII Configuration Page 17 of 21 Speed Settings Under Speed Shutdown No Trip 1200 RPM Activation Delay 0.0s Over Speed Shutdown Trip 1710 RPM Activation Delay 0.08 Overshoot Delay 20s Plant Battery Voltage Alarms Under Voltage Yes Warning 200 VDC Return 220VDC Delay 1m Over Voltage Yes Return 29.0 VDC Warning 40.0 VDC Delay 1m Charge Alternator Alarm Shutdown Enabled Trip 40VDC Delay 5s Warning Enabled Trip ~6.0VDC Delay 5s about:blank 6110 (RTH) MKII Configuration Start On Low Battery Enable No Threshold 180VDC Engine Run Duration th Delay 5s Maintenance Alarm Maintenance Alarm 1 Enable No Description Maintenance Alatm 1 Action Warning Engine Run Hours 10 hrs Enable Alarm On Due Date No Maintenance Interval 1 months Maintenance Alarm 2 Enable No Description Maintenance Alarm 2 Action Warning Engine Run Hours 10 hrs Enable Alarm On Due Date No Maintenance Interval 1 months Maintenance Alarm 3 Enable No Description Maintenance Alarm 3 Action Warning Engine Run Hours 10 hrs Enable Alarm On Due Date No Maintenance Interval 1 months Scheduler Exercise Scheduler Enabled ‘Schedule Period Week Day Run Mode Start Time Duration Monday OffLoad 00:00 0:00 Monday OffLoad 00:00 00:00 Monday OffLoad 00:00 00:00 Monday OffLoad 00:00 00:00 Monday OffLoad 00:00 00:00 Monday OffLoad 00:00 00:00 Monday OffLoad 00:00 00:00 Monday OffLoad 00:00 00:00 about:blank No Weekly Page 18 of 21 6110 (RTH) MKII Configuration Page 19 of 21 about:blank 6110 (RTH) MKII Configuration Page 20 of 21 Display Sti ‘Support Strings Page 1 Line 4 Line 2 Line 3 Page2 Line 4 Line 2 Line 3 Page3 Line 4 Line 2 Line 3 Page 4 Line 4 Line 2 Line 3 Page5 Line 4 Line 2 Line 3 Page6 Line 4 Line 2 Line 3 User Defined Strings Page1 Line 4 Line 2 Line 3 Page2 Line 4 Line 2 Line 3 Alternative Configurations Alternative Configuration Options Alternative Configuration Options about:blank 6110 (RTH) MKII Configuration Page 21 of 21 Default Configuration Main Configuration about:blank

You might also like