The Control Module Is The Nucleus of The Intelligent Omnistar Gx2 Optical Broadband Transmission Platform

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OMNISTAR® GX2

GX2-CM100B
Control Module

The GX2-CM100B control module supervises all the appli-


cation modules and power supplies within the housing
while also serving as the communication gateway
The Control Module is the nucleus of the
between the modules and the various user interfaces.
Three tri-colored LEDs are located on the front panel of
intelligent OmniStar GX2 optical broadband
the module: one indicates the worst-case status for all transmission platform.
application modules and the other two indicate the status
of the power supplies. The front panel Ethernet port
allows local control and monitoring of all modules through
a Web browser-style interface on a PC. The rear Ethernet
port can be used for SNMP communications with a net-
BENEFITS INCLUDE:
work management system.
• Power PC technology provided by Motorola for enhanced intelligence
Although the application modules can operate without it, • Internal subagent allows communication with SNMP and requires no
the control module is necessary to setup and monitor proprietary software
modules through either the display option on the shelf • Provides Quick-Swap capabilities where replacement modules are recognized
door or the Web browser-style interface. The control and updated with the prestored settings
module also enables some of the advanced OmniStar
• Downloadable firmware
GX2 features such as Quick-Swap Module Configuration
and downloadable firmware. • Two Ethernet ports for communication with local PC and standard
network management system
• Hot-swappable with blind-mating to OmniStar GX2 Housing
• Contact closure relay for external alarm capability
SPECIFICATIONS

Communications Interface
Local Ethernet Port (front panel)
Data Format SNMP
Data Rate 10Mbit/s (10BaseT Ethernet)
Connector RJ-45
Network Management Port (rear panel)
Data Format SNMP
Data Rate 10Mbit/s (10BaseT Ethernet)
Connector RJ-45
Shelf Display Unit Connector Mini-DIN
Alarm Relay Contact Closure, 250mA/40 Vac or Vdc Max
General
Power Consumption 5 Watts Max.
Operating Temperature Range -20° C to +65° C (-4° F to 149° F)
Storage Temperature Range -40° C to 80° C (-40° F to 176° F)
Dimensions 1" W x 5.9" H x 15" D
(2.5 cm x 15 cm x 38 cm)
Weight 2.0 lbs. (1 kg)
Mounting GX2-HSG* Equipment Shelf

Control Module
Model Number Description
GX2-CM100B (Control Module)

For more technical information regarding the latest in optical broadband transmission technology from Motorola,
refer to the OmniStar GX2 data sheets.

Motorola, Inc.
Broadband Communications Sector
101 Tournament Drive MOTOROLA and the Stylized M Logo are registered in the U.S. Patent and Trademark Office.
Horsham, PA 19044 All other product or service names are the property of their respective owners. ©Motorola, Inc. 2002.
1.800.523.6678
www.motorola.com/broadband XX0000/X

You might also like