8B0C0160HW00.001-1: 1 General Information
8B0C0160HW00.001-1: 1 General Information
8B0C0160HW00.001-1: 1 General Information
001-1
8B0C0160HW00.001-1
1 General information
• Connections for supplying external 24 V devices
• Extensive protective measures
2 Order data
Model number Short description Figure
Wall mounting
8B0C0160HW00.001-1 ACOPOSmulti auxiliary supply module, 16 A, HV, wall mounting,
24VOut 1x 16 A, 1x 5 A
Required accessories
Terminal block sets
8BZ0C016000.001-1A Screw clamp set for ACOPOSmulti mod-
ules 8B0C0160Hx00.001-1: 1x 8TB3104.201M-11, 1x
8TB2104.2010-00, 1x 8TB2106.2010-00
Optional accessories
Fan modules
8BXF001.0000-00 ACOPOSmulti fan module, replacement fan for ACOPOSmulti
modules (8BxP / 8B0C / 8BVI / 8BVE / 8B0K)
Terminal blocks
8TB2104.2010-00 4-pin screw clamp, single row, spacing: 5.08 mm, label 1: num-
bered serially
8TB2106.2010-00 6-pin screw clamp, single row, spacing: 5.08 mm, label 1: num-
bered serially
8TB3104.201M-11 Screw clamp 4-pin, single-row, spacing: 7.62 mm, label 1: num-
bered serially, M keying: 1011
3 Technical data
Model number 8B0C0160HW00.001-1
General information
Cooling and mounting method Wall mounting
Certification
CE Yes
KC Yes
UL cULus E225616
Power Conversion Equipment
DC bus connection
Voltage
Nominal 750 VDC
Operating range in continuous operation 260 to 800 VDC
Full continuous power 315 to 800 VDC
Continuous power consumption Max. 445 W
Power loss with continuous power 45 W
DC bus capacitance 220 nF
Design ACOPOSmulti backplane
24 VDC output
Continuous power 1) 400 W
Output voltage
DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC / 315)
DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
Continuous current 16 ADC
Reduction of continuous power depending on an No reduction
ambient temperature above 40°C
Reduction of continuous power depending on the
installation elevation
Starting at 500 m above sea level 40 W per 1000 m
Reduction of continuous power depending on the No reduction
cooling method
Startup delay Max. 1 s
Startup time Approx. 5 to 20 ms
4 Status indicators
Status indicators are located on the black cover of each module.
Figure 1: Indicator groups for auxiliary supply modules with 24 V Out (8B0C0xx0Hx00.00x-1)
Permitted
mounting orientations
3)
2)
1)
Hanging vertically
Lying horizontally
Impermissible
mounting orientations
Standing horizontally
2)
2)
Hanging horizontally
6 Wiring
6.1 Pinout overview - 8B0C0160Hx00.001-1, 8B0C0320Hx00.002-1
4 3 2 1
Information:
B&R recommends grounding both COM connections (1, 2) on the X3 plug to achieve a defined rela-
tionship between the signal ground and ground potential. Alternatively, the COM (2) connection can
also be grounded on the X2 connector.
Filters