The intelligent system for cable fault location, Higher efficiency through
testing, and diagnostics innovative technology
↗ Simple, convenient, and fast operation ▪ Time savings thanks to parallel dissipation
factor and partial discharge measurement
↗ High-performance technology and the highest safety standard
▪ Interface to GIS systems
↗ Customised, process-oriented, and adaptable ▪ Central data management
↗ Complete 3-phase cable fault location and diagnostics ▪ Surge energy up to 3000 J, complete surge
energy on all voltage levels
system in a vehicle up to 3.5 t
▪ Precise fault location methods for every
type of fault and various cables, e.g.
titron® is a fully automatic, centrally controlled, and intelligent system for cable fault – SIM/MIM – the most effective method
location, cable testing, and diagnostics. for cable fault location
– Conditioning-SIM/MIM – helpful in
Thanks to the innovative operational concept and high-performance technology, locating wet faults that are difficult to
the titron® system is able to carry out measurements faster, more easily, and with detect
greater precision. All of the test van's functions are controlled centrally via the BAUR – DC-SIM/MIM – for breakdown faults and
software. The intuitive user interface of the BAUR software provides optimal support intermittent faults
to both asset managers and measurement engineers in their workflows. – Differential methods for the fault loca-
tion in branched networks
Fault location. Recommendations for the cable fault location process are generated ▪ BAUR Fault Location App3) for remote con-
based on a multitude of factors that link the system, in an intelligent manner, to an trol of the cable fault pin-pointing process
algorithm specifically designed for this purpose. Nevertheless, the user is still, at any ▪ Maximum safety for the operator and the
time, able to override the given specifications of the system and to carry out the system
measurement process based on his own experience and knowledge. For cable fault
location, the BAUR software includes a multitude of precise fault location methods
for every type of fault and various cables.1)
Testing and diagnostics. With the diagnostics methods based on dissipation factor F urther information can be found in the
and partial discharge measurement, proven methods are available for comprehensive following data sheets:
1)
IRG 4000 time domain reflectometer and
cable analysis. This not only enables the early detection and location of PD-related
BAUR software for cable fault location
weak points in medium-voltage cables and cable accessories, but also the assessment 2)
BAUR software for cable testing and
diagnostics
of dielectric ageing based on the dissipation factor values.2) 3)
BAUR Fault Location App
Note: The availability of individual methods, functions, and voltage levels depends on the system configuration.
BAUR GmbH · Raiffeisenstraße 8, 6832 Sulz, Austria · T +43 (0)5522 4941-0 · F +43 (0)5522 4941-3 · [email protected] · www.baur.eu
titron®
The state-of-the-art in cable fault location
↗ Central system control via the BAUR software and high-performance industrial PC
↗ Highest level of efficiency and measurement precision through the optimally
adjusted measurement path, combined with modern digital signal processing
↗ Extremely high reliability by monitoring and recording all system events
↗ Quick start: ready for operation in just a few seconds
↗ All operation-related error messages are displayed clearly on the screen and Figures and screenshots are illustrative
are immediately visible to the user.
Page 2/8 Data sheet: BAUR GmbH · 826-132-2 · 07.2021 · Subject to modifications
titron®
Find your cable fault with just a few clicks!
Smart Cable Fault Location Guide
↗ The intelligent Smart Cable Fault Location Guide leads the operator step-by-step – quickly and efficiently
– to the cable fault.
↗ A special algorithm continuously analyses the current measurement results, which it uses to generate
optimum recommendations for the operator regarding the further procedure required to reliably locate
the cable fault.
↗ Automatic fault analysis with clear graphical presentation giving a better overview.
↗ Test voltage wizard:
– The system recommends voltage values according to the cable data and the fault type.
– The test voltages can be defined according to the user.
↗ Automatic cursor positioning at the cable end and at the fault location
↗ Automatic adjustment of method-related parameters for quick and efficient fault location.
↗ Clear graphical presentation of the measurement results with helpful functions for evaluation
↗ Envelope curve display for intermittent faults – even small changes in impedance are made visible and
saved.
All this with full flexibility for experienced operators! Experienced measurement engineers can use
their know-how directly at any point during the measurement process and select a user-specific procedure.
Cable route MPS 135 Cable length 999 m Voltage level 12/20 kV Phases 3 Cable data
Screenshot is illustrative
Data sheet: BAUR GmbH · 826-132-2 · 07.2021 · Subject to modifications Page 3/8
titron®
A sophisticated workstation – ergonomic, practical, and comfortable
Better ergonomics in the workplace Easy and convenient to operate
I. High voltage
Surge voltage
Surge voltage ranges 0 – 8 kV, 0 – 16 kV, 0 – 32 kV
Surge energy 3000 J @ 8, 16, and 32 kV Surge energy Surge energy Surge energy
2050 J @ 8, 16, and 32 kV of choice of choice of choice
1540 J @ 8, 16, and 32 kV
Surge capacitor extension SZ 1550: SZ 2650: Option Option Option
For surge energy class 3000 J: 1820 J @ 4 kV 2890 J @ 4 kV
For surge energy class 2050 J: 1580 J @ 4 kV 2660 J @ 4 kV
For surge energy class 1540 J: 1460 J @ 4 kV 2530 J @ 4 kV
Surge sequence 5 – 20 pulses/min, single surge
Capacitor charge time Max. surge voltage 32 kV in 3 s
Voltage sources
SSG 40 surge voltage generator
DC voltage 0 – 40 kV, Imax = 50 mA
viola VLF HV generator Option Option Option
DC voltage 0 to ±60 kV
VLF voltage truesinus® 0 – 44 kVrms Square wave 0 – 60 kV
Frequency range 0.01 – 0.1 Hz
Max. capacitive load Up to 10 µF; 0.85 µF @ 0.1 Hz at 44 kVrms
2.7 µF @ 0.03 Hz at 44 kVrms; 7.7 µF @ 0.01 Hz at 44 kVrms
PHG 70 VLF HV generator Option Option Option
DC voltage 0 to ±70 kV; Imax = 10 mA @ 70 kV; 90 mA @ 20 kV
VLF voltage truesinus® 0 – 38 kVrms Square wave 0 – 57 kV
Frequency range 0.01 – 1 Hz
Max. capacitive load Up to 20 µF; 3 µF @ 0.1 Hz at 38 kVrms
PHG 80 VLF HV generator Option Option Option
DC voltage 0 to ±80 kV; Imax = 1.8 mA @ 80 kV; 90 mA @ 20 kV
VLF voltage truesinus® 0 – 57 kVrms Square wave 0 – 80 kV
Frequency range 0.01 – 1 Hz
Max. capacitive load Up to 20 µF; 1.2 µF @ 0.1 Hz at 57 kVrms
3 µF @ 0.1 Hz at 38 kVrms
Data sheet: BAUR GmbH · 826-132-2 · 07.2021 · Subject to modifications Page 5/8
Technical data
titron® titron® titron®
3-phase 1-phase compact
Page 6/8 Data sheet: BAUR GmbH · 826-132-2 · 07.2021 · Subject to modifications
Technical data
titron® titron® titron®
3-phase 1-phase compact
Contact:
BAUR GmbH (Headoffice Österreich) BAUR France 奥地利保尔公司上海代表处
T +43 (0)5522 4941-0 T +33 (04) 69 98 27 27 电话 +86 (0)21 6133 1877
[email protected] [email protected] [email protected]
BAUR Prüf- und Messtechnik GmbH Baur do Brasil Ltda. BAUR Representative Office Hong Kong
T +49 (0)2181 2979 0 T +55 11 297 25 272 T +852 2780 9029
[email protected] [email protected] [email protected]
BAUR GmbH (Branch UAE) BAUR Test Equipment Ltd. (UK) BAUR representatives:
T +971 50 4440270 T +44 (0)20 8661 0957 www.baur.eu > BAUR worldwide
[email protected] [email protected]
Page 8/8 Data sheet: BAUR GmbH · 826-132-2 · 07.2021 · Subject to modifications