Victaulic Data IGS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

Victaulic FireLock™ Innovative Groove System | IGS™

for 1"/DN25 Sprinkler Pipe 10.54

No. 142 Style 922 Style 920N No. 101 Style 108 No. 102
Welded Outlet Outlet-T Mechanical-T Outlet Installation-Ready™ Installation-Ready™ Installation-Ready™
90º Elbow Rigid Coupling Tee

Style 115 No. 148 Sprinkler No. 65 No. 144 No. 145 Female NPT No. 143
OGS x IGS™ Reducer, NPT or Grooved End OGS x IGS™ Grooved or BSPT Threaded x Close Nipple
Reducing Coupling BSPT sprinkler outlet of Run Fitting Concentric Reducer Groove 90º Elbow

No. 140 No. 141 No. 146 Cap RG2100 Roll VicFlex™ Series VicFlex™ Series
Male NPT or BSPT Female NPT or BSPT Grooving Tool AH2‑CC Braided AH1‑CC Braided
Threaded x Groove Threaded x Groove Flexible Hose Flexible Hose
Adapter Adapter with Captured with Captured
Coupling (Refer to Coupling (Refer to
publication 10.85) publication 10.95)

1.0  PRODUCT DESCRIPTION


Pipe Material
• Carbon steel, Schedule 10, Schedule 40. For use with alternative materials please contact Victaulic.
Maximum Working Pressure
• Up to 365 psi/2517 kPa/25 bar
Pipe Preparation
• Cut (Sch. 40) or roll (Sch. 10 or Sch. 40) grooved in accordance with publication 25.14: Victaulic IGS Groove Specifications.
RG2100 Grooving Capability
• 1"/DN25
• Workstation designed to cut, ream and form a roll groove on carbon steel, Sch. 10 or Sch. 40 pipe.
• This tool has a minimum pipe length requirement of 4 ½"/114 mm.

ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT.

System No. Location Spec Section Paragraph

Submitted By Date Approved Date

victaulic.com
10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.
1
victaulic.com

2.0 CERTIFICATION/LISTINGS

NOTES
• Approvals listed above do not apply to the RG2100 Roll Grooving Tool.

3.0  SPECIFICATIONS – MATERIAL


Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12
Housing Coating:
Orange enamel
Red enamel (Europe)
Optional: Hot dipped galvanized
Gasket:
Grade “E” EPDM (Type A) Vic-Plus™ Pre-lubricated Gasket

EPDM (Violet Color Code). Applicable for wet and dry (oil-free air) fire protection systems only. Listed/Approved
for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40°C and above. NOT
COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES.
NOTES:
• Reference should always be made to publication I-100, Victaulic Field Installation Handbook for gasket lubrication instructions.
• Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always
be made to publication 05.01, Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible.

Bolts/Nuts:
Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and
ISO 898-1 Class 9.8 (M10-M16) Class 8.8 (M20 and greater). Carbon steel hex nuts meeting the mechanical
property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric -
hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type III (imperial) or
Type II (metric).
Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449).
Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type III Finish
No. 140, 141, 142, 143, 144, 148: Carbon steel meeting the chemical and mechanical property requirements of
ASTM A53 Grade A
No. 65, 145, 146: Ductile iron conforming to ASTM A536, Grade 65-45-12
RG2100 Roll Grooving Tool:
Required Power Supply: Power Drive with Foot Switch (½ HP, Universal reversible motor, single-phase, 25-60 HZ)
Accessories/Components:
Tool head assembly
Carriage assembly - accepts RG2100 tool head assembly, Standard Cutter, Standard Reamer and Standard Lever

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 2
victaulic.com

4.0 DIMENSIONS
No. 142 Welded Outlet
I.D.

E to E

Actual Inside
Nominal Outside Diameter Diameter Weight
inches inches Approximate
I.D. E to E (Each)
DN mm
inches inches lb
Run x Branch Run x Branch mm mm kg
1 ¼ – 1 ½ 1.660 – 1.900 1.049 1.00 0.2
DN32 – DN40 42.4 – 48.3 26.6 25.4 0.1
1½ – 2 1.900 – 2.375 1.049 1.00 0.2
DN40 – DN50 48.3 – 60.3 26.6 25.4 0.1
2 – 2 ½ 1 2.375 – 3.000 1.315 1.049 1.00 0.2
x x
DN50 – DN65 DN25 60.3 – 76.1 33.7 26.6 25.4 0.1
2 ½ – 3 2.875 – 3.500 1.049 1.00 0.2
DN65 – DN80 73.0 – 88.9 26.6 25.4 0.1
3–4 3.500 – 4.500 1.049 1.00 0.2
DN80 – DN100 88.9 – 114.3 26.6 25.4 0.1

4.1 DIMENSIONS
Style 922 Outlet-T
Y Z

Size Dimensions Weight


Actual
Nominal Outside Diameter Minimum Hole Maximium
inches inches Diameter/Hole Hole Diameter/ Approximate
DN mm Saw Size Hole Saw Size Y V W Z (Each)
inches inches inches inches inches inches lb
Run x Branch Run x Branch
mm mm mm mm mm mm kg
1 ¼ 1.660 1 3/16 1¼ 4.01 1.98 1.10 2.70 1.1
DN32 42.4 30.0 32.0 101.9 50.3 27.9 68.6 0.5
1 ½ 1.900 1 3/16 1¼ 4.01 2.11 1.22 2.70 1.2
DN40 1 48.3 1.315 30.0 32.0 101.9 53.6 31.0 68.7 0.5
x x
2 DN25 2.375 33.7 1 3/16 1¼ 4.01 2.34 1.46 2.56 1.2
DN50 60.3 30.0 32.0 101.9 59.4 37.1 65.1 0.5
2 ½ 2.875 1 3/16 1¼ 4.01 2.67 1.71 2.56 1.6
73.0 30.0 32.0 101.9 67.8 43.4 65.1 0.7

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 3
victaulic.com

4.2 DIMENSIONS
Style 920N Mechanical-T Outlet

Y Z

Size Dimensions Weight


Actual
Nominal Outside Diameter Minimum Hole Maximium
inches inches Diameter/Hole Hole Diameter/ Approximate
DN mm Saw Size Hole Saw Size Y V W Z (Each)
inches inches inches inches inches inches lb
Run x Branch Run x Branch
mm mm mm mm mm mm kg
3 3.500 1½ 1 5/8 6.42 3.12 2.28 2.75 2.7
DN80 1 88.9 1.315 38.1 41.0 163.0 79.2 57.9 69.9 1.2
x x
4 DN25 4.500 33.7 1½ 1 5/8 186.6 3.62 2.69 2.75 3.0
DN100 114.3 38.1 41.0 7.35 91.9 68.3 69.10 1.4

4.3 DIMENSIONS
No. 101 Installation-Ready 90° Elbow
C to E
F

B
F
C to E

Pre-Assembled Assembled

Size Bolt/Nut Dimensions Weight


Actual
Outside F Approximate
Nominal Diameter Qty. Size Take Out C to E B Pre-Assembled Assembled (Each)
inches inches inches inches inches inches inches inches lb
DN mm mm mm mm mm mm mm kg
1 1.315 3/8 x 2 1.25 2.13 4.25 2.75 2.75 2.2
3
DN25 33.7 M10 x 50 32 54 108 70 70 1.0

NOTE
• Not for use with grooved sprinklers, for grooved sprinkler connections please refer to publication 10.65 for the Style V9 sprinkler coupling.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 4
victaulic.com

4.4 DIMENSIONS
Style 108 Installation-Ready Rigid Coupling
YB YB
YL Z YL Z

X X

Preassembled Assembled

Pipe End
Size Separation1 Bolt/Nut Dimensions Weight
Actual Pre-Assembled Assembled
Outside Approx
Nominal Diameter Allowable Qty. Size YL YB X Z YL YB X Z (Each)
inches inches inches inches inches inches inches inches inches inches inches inches lb
DN mm mm mm mm mm mm mm mm mm mm mm kg
1 1.315 0.14 3/8 x 2 1.66 2.17 2.58 1.43 1.61 2.29 2.27 1.43 1.5
1
DN25 33.7 3.6 M10 x 50 42.2 55.2 65.5 36.3 41.0 58.2 57.5 36.3 0.7
1 The allowable pipe end separation dimension shown is for system layout purposes only. FireLockTM Style 108 rigid couplings are considered rigid connections
and will not accommodate expansion or contraction of the piping system.
NOTE
• Not for use with grooved sprinklers, for grooved sprinkler connections please refer to publication 10.65 for the Style V9 sprinkler coupling.

4.5 DIMENSIONS
No. 102 Installation-Ready Tee
C to R C to R
F F

D
F
C to B

Pre-Assembled Assembled

Size Bolt/Nut Dimensions Weight


Actual
Outside F Approximate
Nominal Diameter Qty. Size Take Out C to B D Pre-Assembled Assembled (Each)
inches inches inches inches inches inches inches inches lb
DN mm mm mm mm mm mm mm kg
1 1.315 3/8 x 2 1.25 2.13 4.13 2.75 2.75 3.0
4
DN25 33.7 M10 x 50 32 54 105 70 70 1.4
NOTE
• Not for use with grooved sprinklers, for grooved sprinkler connections please refer to publication 10.65 for the Style V9 sprinkler coupling.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 5
victaulic.com

4.6 DIMENSIONS
Style 115 OGS x IGS Reducing Coupling
Y
Y Z

X X

Pre-Assembled Assembled

Dimensions
Pipe End
Size Separation2 Bolt/Nut Pre-Assembled Assembled Weight
Actual Approximate
Nominal Outside Diameter Allowable Qty. Size X Y Z X Y Z (Each)
inches inches inches inches inches inches inches inches inches inches lb
DN mm mm mm mm mm mm mm mm mm kg
1¼ 1.660 0.14 3/8 x 2 3.13 4.75 1.75 2.63 4.75 1.75 1.9
1
DN32 1 42.4 1.315 3.6 M10 x 50 79 121 44 67 121 44 0.9
x x
1½ DN25 1.900 33.7 0.14 3/8 x 2 3.25 4.88 1.75 2.88 4.88 1.75 2.1
1
DN40 48.3 3.6 M10 x 50 83 124 44 73 124 44 0.9
2 The allowable pipe end separation dimension shown is for system layout purposes only. FireLock™ Style 115 rigid couplings are considered rigid connections
and will not accommodate expansion or contraction of the piping system.
NOTE

• Not for use with grooved sprinklers, for grooved sprinkler connections please refer to publication 10.65 for the Style V9 sprinkler coupling.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 6
victaulic.com

4.7 DIMENSIONS
No. 148 Sprinkler Reducer

E to E

Length Size Threaded Outlet Size Weight


Actual Outside Approximate
E to E Nominal Diameter (Each)
inches inches inches inches inches lb
mm DN mm DN DN kg
3 1 1.315 ½ ¾ 0.4
76 DN25 33.7 DN15 DN20 0.2
3.5 1 1.315 ½ ¾ 0.5
89 DN25 33.7 DN15 DN20 0.2
4 1 1.315 ½ ¾ 0.6
102 DN25 33.7 DN15 DN20 0.3
4.5 1 1.315 ½ ¾ 0.6
114 DN25 33.7 DN15 DN20 0.3
5 1 1.315 ½ ¾ 0.7
127 DN25 33.7 DN15 DN20 0.3
5.5 1 1.315 ½ ¾ 0.8
140 DN25 33.7 DN15 DN20 0.3
6 1 1.315 ½ ¾ 0.8
152 DN25 33.7 DN15 DN20 0.4
12 1 1.315 ½ ¾ 1.7
305 DN25 33.7 DN15 DN20 0.8
18 1 1.315 ½ ¾ 2.5
457 DN25 33.7 DN15 DN20 1.1
24 1 1.315 ½ ¾ 3.4
610 DN25 33.7 DN15 DN20 1.5
30 1 1.315 ½ ¾ 4.2
762 DN25 33.7 DN15 DN20 1.9
NOTE
• NPT or BSPT available
• It is acceptable to cut and groove any No. 148 longer than 6"/152mm. The minimum allowable cut length is 6"/152mm for a No. 148.

No. 148 Double Ended Sprinkler Reducer

E to E

Length Size Threaded Outlet Size Weight


Actual Outside Approximate
E to E Nominal Diameter (Each)
inches inches inches inches inches lb
mm DN mm DN DN kg
36 1 1.315 ½ ¾ 5.0
914 DN25 33.7 DN15 DN20 2.3
NOTE
• 36"/914mm size features sprinkler outlet on both ends for field fabrication.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 7
victaulic.com

4.8 DIMENSIONS
No. 65 IGS Grooved End of Run Fitting
C to E

C to E

Size Dimensions Weight


Actual Approximate
Nominal Outside Diameter C to E (Each)
inches inches inches lb
DN mm mm kg
1¼ 1.660 1.88 0.7
DN32 42.4 48 0.3
1½ 1.900 2.00 0.8
DN40 48.3 51 0.4
2 1 2.375 1.315 2.25 1.2
x x
DN50 DN25 60.3 33.7 57 0.5
2½ 2.875 2.50 1.6
73.0 64 0.7
3 3.500 2.75 2.6
DN80 88.9 70 1.2

4.9 DIMENSIONS
No. 144 OGS x IGS Grooved Concentric Reducer
E to E

Size Dimensions Weight


Actual Approximate
Nominal Outside Diameter E to E (Each)
inches inches inches lb
DN mm mm kg
1¼ 1.660 3.00 0.5
DN32 1 42.4 1.315 76 0.2
x x
1½ DN25 1.900 33.7 3.00 0.6
DN40 48.3 76 0.2

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 8
victaulic.com

4.10 DIMENSIONS
No. 145 Female Threaded x Groove 90º Elbow
C to TE

C to GE

Size Dimensions Weight


Actual Outside
Nominal Diameter
inches inches Approximate
DN mm C-TE C-GE (Each)
Threaded Grooved Threaded Grooved inches inches lb
Outlet Outlet Outlet Outlet mm mm kg
½ 0.840 1.45 1.60 0.5
DN15 21.3 36.8 40.6 0.2
¾ 1 1.050 1.315 1.45 1.60 0.5
x x
DN20 DN25 26.9 33.7 36.8 40.6 0.2
1 1.315 1.50 1.60 0.5
DN25 33.7 38.1 40.6 0.2

4.11 DIMENSIONS
No. 143 Close Nipple

E to E

Size Dimensions Weight


Actual
Outside Approximate
Nominal Diameter E to E (Each)
inches inches inches lb
DN mm mm kg
1.53 0.2
38 0.1
2 0.3
51 0.1
2.5 0.4
64 0.2
3 0.4
1 1.315 76 0.2
DN25 33.7 3.5 0.5
89 0.2
4 0.6
102 0.3
4.5 0.6
114 0.3
5 0.7
127 0.3
3 Bolt pad interferences may occur in some installation configurations.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 9
victaulic.com

4.12 DIMENSIONS
No. 140 Male Threaded x Groove Adapter

E to E

Size Dimensions Weight


Actual
Outside Approximate
Nominal Diameter E-E (Each)
inches inches inches lb
DN mm mm kg
1 1.315 2.50 0.3
DN25 33.7 63.5 0.1

No. 141 Female Threaded x Groove Adapter

E to E

Size Dimensions Weight


Actual
Outside Approximate
Nominal Diameter E-E (Each)
inches inches inches lb
DN mm mm kg
1 1.315 2.00 0.5
DN25 33.7 50.8 0.2

4.13 DIMENSIONS
No. 146 Cap

Size Dimensions Weight


Actual
Outside Approximate
Nominal Diameter T (Each)
inches inches inches lb
DN mm mm kg
1 1.315 0.55 0.2
DN25 33.7 14.0 0.1

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 10
victaulic.com

4.14 DIMENSIONS
RG2100 Roll Grooving Tool

Tool
A B C Weight
inches inches inches lb
mm mm mm kg
8.5 17.1 8.7 37.5
216 435 222 17.0

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 11
victaulic.com

5.0 PERFORMANCE
Friction Flow Data
Size Equivalent Length of 1" Sch. 40 Pipe (C=12)
Actual No. 102 No. 102
Nominal Outside Diameter No. 101 (Branch) (Run) Style 115 No. 148 No. 144
inches inches feet feet feet feet feet feet
DN mm Style 922 Style 920N meters meters meters meters meters meters
1 1.315 See publication See publication 2.0 5.0 2.7
– See note –
DN25 33.7 10.52 11.02 0.61 1.52 0.82
1¼ 1 1.660 1.315 5.7 3.9
x x – – – – – –
DN32 DN25 42.4 33.7 1.74 1.19
1½ 1.900 5.0 4.3
– – – – – –
DN40 48.3 1.52 1.31

NOTE
• In accordance with NFPA 13, friction loss shall be excluded for fittings directly connected to a sprinkler. For hydraulic calculations, Victaulic recommends
using the installed length (E-E or cut length) of the No. 148 Sprinkler Reducer as the equivalent length of 1"/DN25 Sch. 40 pipe.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 12
victaulic.com

5.0  PERFORMANCE (CONTINUED)


Maximum Working Pressure
cULus FM LPCB VdS
psi psi psi psi
kPa kPa kPa kPa
Style/No. bar bar bar bar
1424 365 365 365 232
2517 2517 2517 1600
25 25 25 16
9224 300 300 365 232
2100 2100 2517 1600
21 21 25 16
920N4 365 300 365 232
2517 2100 2517 1600
25 21 25 16
1015 365 365 365 232
2517 2517 2517 1600
25 25 25 16
1085 365 365 365 232
2517 2517 2517 1600
25 25 25 16
1025 365 365 365 232
2517 2517 2517 1600
25 25 25 16
1154 365 365 365 232
2517 2517 2517 1600
25 25 25 16
148 365 365 365 232
2517 2517 2517 1600
25 25 25 16
65 365 365 365 232
2517 2517 2517 1600
25 25 25 16
144 365 365 365 232
2517 2517 2517 1600
25 25 25 16
145 365 365 365 232
2517 2517 2517 1600
25 25 25 16
143 365 365 365 232
2517 2517 2517 1600
25 25 25 16
140 365 365 365 232
2517 2517 2517 1600
25 25 25 16
141 365 365 365 232
2517 2517 2517 1600
25 25 25 16
146 365 365 365 232
2517 2517 2517 1600
25 25 25 16
4 Maximum pressure rating is 300 psi/21 bar when installed on lightwall steel pipe, as follows:
Mega-Flow and Mega-Flow-GF steel pipe manufactured by Wheatland Tube Co.
Mega-Thread steel pipe manufactured by Wheatland Tube Co.
MLT steel pipe manufactured by Wheatland Tube Co.
WLS steel pipe manufactured by Wheatland Tube Co.
Eddy Flow steel pipe manufactured by Bull Moose Tube Co.
Eddythread steel pipe manufactured by Bull Moose Tube Co.
EZ-Thread steel pipe manufactured by Youngstown Tube Co.
Fire-Flo steel pipe manufactured by Youngstown Tube Co.
Easy-Flow pipe manufactured by Borusan Mannesmann
5 Maximum pressure rating is 300 psi / 21 bar when installed on lightwall steel pipe, as follows:
Mega-Thread steel pipe manufactured by Wheatland Tube Co.
MLT steel pipe manufactured by Wheatland Tube Co
WLS steel pipe manufactured by Wheatland Tube Co
Eddythread steel pipe manufactured by Bull Moose Tube Co.
EZ-Thread steel pipe manufactured by Youngstown Tube Co.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 13
victaulic.com

6.0 NOTIFICATIONS

WARNING
• Read and understand all instructions before attempting to install any Victaulic
products.
• Always verify that the piping system has been completely depressurized and
drained immediately prior to installation, removal, adjustment, or maintenance of
any Victaulic products.
• Wear safety glasses, hardhat, and foot protection.
Failure to follow these instructions could result in death or serious personal injury
and property damage.
• These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable
National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable
building and fire codes. These standards and codes contain important information regarding protection of systems from freezing
temperatures, corrosion, mechanical damage, etc.
• The installer shall understand the use of this product and why it was specified for the particular application.
• The installer shall understand common industry safety standards and potential consequences of improper product installation.
• It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system
and external environment.
• The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level,
and flow rate on materials to confirm system life will be acceptable for the intended service.
Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause
system failure, resulting in death or serious personal injury and property damage.

WARNING

Failure to follow instructions and warnings could result in serious personal injury,
property damage, and/or product damage.
• Before operating or servicing any grooving tools, read all instructions in the
manual and all warning labels on the tool.
• Wear safety glasses, hardhat, foot protection, and hearing protection while
working around the tool.
• Save the operating and maintenance manual in a place accessible to all
operators of the tool
If you need additional copies of any literature, or if you have questions concerning the safe and proper operation of the
tool, contact Victaulic, P.O. Box 31, Easton, PA 18044-0031, Phone: 1‑800‑PICK VIC, E-Mail: [email protected].

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 14
victaulic.com

7.0  REFERENCE MATERIALS


10.06: FireLock Installation-Ready Fittings
10.52: Style 922 Outlet Tee
10.85: VicFlex Series AH2 ad AH2-CC Braided Hose
11.02 Mechanical-T Bolted Branch Outlets
25.14: Victaulic IGS Groove Specification
I-101-103: FireLock™ Installation-Ready™ Fittings Installation Instruction
I-102: FireLock™ Installation-Ready™ Fittings Installation Instruction
I-108: FireLock™ Installation-Ready™ Coupling
I-115: FireLock EZ™ Installation-Ready™ Reducing Coupling Installation Instruction
I-ENDCAP: Victaulic End Cap Installation Safety Instructions
I-V9: Style V9 Victaulic® FireLock™ IGS™ Installation-Ready™ Sprinkler Coupling
TM-RG2100: Operating and Maintenance Instructions Manual

Victaulic No. 148


Length ½" DN15 outlet ¾" DN20 outlet
Equivalent Length of 1"
E to E Sched. 40 Pipe (C=120)
inches feet
mm meters
≤6 6.6 3.8
152 2.0 1.2
6 – 12 5.5 3.8
152 – 305 1.7 1.2
12 – 18 6.2 4.3
305 – 457 1.9 1.3
18 – 24 6.7 4.7
457 – 610 2.0 1.4
24 – 30 7.1 5.2
610 – 762 2.2 1.6
30 – 36 7.4 5.4
762 – 914 2.3 1.6

NOTE
• When installed in pipe to pipe connections or it is required by the authority having jurisdiction, the equivalent length data in the table above may apply.

User Responsibility for Product Selection and Suitability Note


Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products
Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions.
standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard
regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations.
instructions. Nothing in this or any other document, nor any verbal recommendation, Installation
advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation
or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment
guide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available
Intellectual Property Rights in PDF format on our website at www.victaulic.com.
No statement contained herein concerning a possible or suggested use of any material, Warranty
product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.
under any patent or other intellectual property right of Victaulic or any of its subsidiaries
or affiliates covering such use or design, or as a recommendation for the use of such Trademarks
material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of
property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries.
or patent applications for articles and/or methods of use in the United States and/or other
countries.

10.54 10161 Rev E Updated 12/2018 © 2018 Victaulic Company. All rights reserved.

victaulic.com 15

You might also like