0% found this document useful (0 votes)
160 views2 pages

Ritar RA-1275

This document provides specifications for a 12V 75Ah deep cycle lead-acid battery. The battery contains 6 cells, has a nominal voltage of 12V, capacity of 75Ah at the 10-hour discharge rate, and weighs approximately 23.5 kg. It has a maximum discharge current of 750A for 5 seconds and a design life of 12 years under floating charge. The battery is suitable for applications involving renewable energy storage, electric vehicles, medical equipment, and backup power systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
160 views2 pages

Ritar RA-1275

This document provides specifications for a 12V 75Ah deep cycle lead-acid battery. The battery contains 6 cells, has a nominal voltage of 12V, capacity of 75Ah at the 10-hour discharge rate, and weighs approximately 23.5 kg. It has a maximum discharge current of 750A for 5 seconds and a design life of 12 years under floating charge. The battery is suitable for applications involving renewable energy storage, electric vehicles, medical equipment, and backup power systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DC12-75(12V75Ah)

Specification
Cells Per Unit 6
Voltage Per Unit 12
Capacity 75Ah@10hr-rate to 1.80V per cell @25℃
Weight Approx. 23.5 Kg (Tolerance±2%)
Internal Resistance Approx. 5.8 mΩ
Terminal F11(M6)/F15(M6)
Max. Discharge Current 750A (5 sec)
Design Life 12 years (floating charge)
DC (Deep Cycle) series batteries provide
superior high integrity and reliability. It is
Maximum Charging Current 22.5 A specially designed for frequent cyclic
C3 58.5AH charge and discharge. By using strong
C5 66.0AH grids, thick plate and specially active
Reference Capacity material are designed for repeated
C10 75.0AH
C20 79.0AH deep-discharge applications. The DC
13.6 V~13.8 V @ 25℃
series batteries offers 30% more cyclic
Float Charging Voltage life than the standby series. It is suitable
Temperature Compensation: -3mV/℃/Cell
for solar and wind renewable energy
14.6 V~14.8 V @ 25℃ storage, mobility and medical equipment,
Cycle Use Voltage Temperature Compensation: -4mV/℃/Cell
RV, telecom, broadband and cable TV,
Discharge: -20℃~60℃ UPS systems etc.
Operating Temperature Range Charge: 0℃~50℃
Storage: -20℃~60℃
Normal Operating Temperature Range 25℃±5℃
RITAR Valve Regulated Lead Acid (VRLA) batteries can
be stored for up to 6 months at 25℃ and then recharging
Self Discharge is recommended. Monthly Self-discharge ratio is less
than 3% at 25℃.Please charged batteries before using.

Container Material A.B.S. UL94-HB, UL94-V0 Optional.

Dimensions
260 169 Φ14 Length 260±1mm (10.2 inches)
M6
Width 169±1mm (6.65 inches)
Height 211±1mm (8.31 inches)
5

Total Height 218±1mm (8.58 inches)


Terminal Value
213
218
211

M5 6~7 N*m
M6 8~10 N*m
24

M8 10~12 N*m
203 F11 TERMINAL Unit: mm

Constant Current Discharge Characteristics : A(25 ℃)

F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 193.4 144.4 82.8 47.9 28.0 20.9 16.5 13.9 9.50 8.05 4.10
1.65V 187.0 140.0 81.1 46.9 27.5 20.5 16.3 13.7 9.40 7.97 4.07
1.70V 178.6 134.4 78.8 45.7 26.9 20.1 16.0 13.5 9.25 7.86 4.02
1.75V 167.3 126.7 75.7 44.1 26.0 19.5 15.6 13.2 9.06 7.71 3.95
1.80V 152.2 116.5 71.4 41.9 24.9 18.7 15.0 12.8 8.79 7.50 3.85
1.85V 131.7 102.3 65.3 38.7 23.1 17.6 14.2 12.1 8.39 7.20 3.71

Constant Power Discharge Characteristics : WPC(25℃)

F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 329 252 150 89.5 53.1 39.8 31.7 26.8 18.6 15.8 8.08
1.65V 326 250 149 88.7 52.6 39.5 31.4 26.6 18.4 15.7 8.02
1.70V 315 242 146 86.7 51.5 38.8 30.9 26.2 18.2 15.5 7.93
1.75V 301 232 142 84.1 50.1 37.8 30.2 25.7 17.8 15.2 7.80
1.80V 278 216 135 80.2 48.1 36.4 29.2 24.9 17.3 14.8 7.62
1.85V 245 192 125 74.6 45.0 34.3 27.7 23.8 16.6 14.2 7.35
(Note) The above characteristics data are average values obtained within three charge/discharge cycle not the minimum values.
DC12-75(12V75Ah)
Discharge Characteristics Curve Charge Characteristic Curve for Cycle Use(IU)
Temperature:25℃(77℉) Temperature:25℃(77℉)
(V/cell)
120 0.14 2.60
Charge Volume
2.16

Charge Voltage (VPC)


Charge Current (CA)
Terminal Voltage (v )

100 0.12 2.50

Charge Volume (%)


Charge Voltage
2.00

80 0.10 2.40
1.84
0.1C 0.05C
0.4C 0.2C 60 0.06 2.30
1.68 After 50% Discharge
0.55C
After 100% Discharge
3C 2C1C 40 0.04 2.20
1.52

1.36 20 0.02 2.10


Charge Current
0
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 0 0.00 2.00
min h 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Discharge Time Charging Time(h)

Cycle Life in Relation to Depth of Discharge Relationship Between Charging Voltage and Temperature
120 2.70

100
2.60

Charge Voltage (v )
Cycle use
80
2.43~2.47VPC@25℃
Capacity(%)

2.50

60
100% 50% 30%
DOD DOD DOD 2.40

40

2.30
20 Float charging
2.27~2.30VPC@25℃
2.20
0 -20 -10 0 10 20 30 40 50
300 600 900 1200 1500 1800 2100
Number of Cycles Temperature (℃)

Temperature Effects on Capacity Storage Characteristics


120 100

100 0℃
0 .1 C A 80
Capacity (% )
Capacity (% )

80 0 .2 C A
60
10℃
60
20℃
1 .0 C A 40
40℃ 30℃
40
2 .0 C A
3 .0 C A 20
20

0 0
-20 -10 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 18 20 22 24
Temperature (℃) Storage Time(months)

Effect of Temperature on Long Term Life Relationship of OCV And State of Charge(20℃)
20 2.20

2.15
Battery Voltage (V)
Lift Expectancy (y ears)

16
2.10

2.05
12

2.00

8
1.95

1.90
4
1.85

0 1.80
0 10 20 30 40 50 0 10 20 30 40 50 60 70 80 90 100
Temperature(℃) State Of Capacity (%)

SHENZHEN RITAR POWER CO.,LTD. Add: 10th Floor, Tower C, 1st Building, Software Industry Base, No.81, Xuefu Road, Nanshan District, Shenzhen,
Guangdong, China 518057
URL: www.ritarpower.com Tel: +86-755-33981668/83475380 Fax: +86-755-83475180 E-mail: [email protected] Version 17A-0