2Cfp60 Series Pressure Compensated Flow Regulator: - Priority Style

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

2CFP60 SERIES PRESSURE COMPENSATED

FLOW REGULATOR - PRIORITY STYLE


2CFP60

REG (3)
BYPASS (2)

1 3
INLET (1)

APPLICATION SPECIFICATIONS
2CFP valves are priority flow regulators. The flow (and Figures based on: Oil Temp = 40°C Viscosity = 40 cSt
actuator speed) will be largely independent of the load
and the pressure conditions.
Inlet: 90 litres/min (24 US GPM)
If used to regulate flow from a fixed supply, for example Rated Flow
Reg: 4-60 litres/min (1-16 US GPM)
a standard gear or piston pump, the valve will pass the
required flow and any surplus flow will be diverted to Max Pressure 350 bar (5000 psi)
the bypass port. The bypass flow may be used for a
secondary circuit whether the secondary pressure
All working parts hardened and
9 requirement is higher or lower than the regulated
pressure.
Cartridge Material
ground steel. Zinc plated body.

The valve inlet pressure will be approximately 7 bar Standard aluminium (up to 210 bar*)
(100 psi) more than the regulated or bypass pressure, Body Material
Add suffix ‘377’ for steel option.
whichever is higher.
Mounting Position Unrestricted
OPERATION
Cavity Number CVA-27-04-0 (See Section 17)
Inlet flow passes through the adjustable orifice and the
radial holes in the spool/sleeve assembly then out of
Torque Cartridge
the regulated port. The pressure drop across the into Cavity 75 Nm (55 lbs ft)
orifice is sensed at each end of the spool, producing a
force which, at the required flow rate, overcomes the
spring force. The resultant movement of the spool 2CFP60 0.16 kg (0.35 lbs)
Weight
2CFP65 1.80 kg (3.76 lbs)
regulates the flow by opening the radial valve ports to
the bypass port and closing the regulated flow ports.
Seal Kit Number SK579 (Nitrile) SK579V (Viton)
The valve will pass flow in the return direction but this
is restricted by the flow path through the control orifice. Recommended BS5540/4 Class 18/13
Filtration Level (25 micron nominal)
FEATURES
Operating Temp -20°C to +90°C
Cartridge construction gives versatility of application. A
valve may be fitted into a line body, a custom designed
Nominal Viscosity 5 to 500 cSt
Hydraulic Integrated Circuit or directly into a cylinder or Range
other actuator. Leakproof adjust screw gives easy,
accurate adjustment to required flow setting.
Hardened and ground working parts give accurate flow
control and long working life.
*For applications above 210 bar please consult our technical department or use the steel body option.

Integrated Hydraulics Ltd Integrated Hydraulics Inc


Collins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK. 7047 Spinach Drive, Mentor, Ohio 44060, USA
Tel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170
Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com
9-121.B
PERFORMANCE CARTRIDGE ONLY
BASIC CODE: 2CFP60
LOAD PRESSURE-PSI HEX SOCKET ADJUST
4.0 A/F
BYPASS HIGHER THAN REGULATED HIGHER THAN
REGULATED PRESSURE BYPASS PRESSURE
17.0 A/F
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000

49.5 MAX
65 15
60 32.0 A/F
REGULATED FLOW-LITRES/MIN

REGULATED FLOW-US GPM


55 50 12.5

45 40 10
M27 X 2.0-6g

35 30 7.5

25 20 5.0 REG (3)

70.0
15 10 2.5

BYPASS (2)
0 0
350 280 210 140 70 0 70 140 210 280 350
LOAD PRESSURE-BAR
INLET (1)

COMPLETE VALVE 1/2” PORTS


BASIC CODE: 2CFP65
Body ONLY part numbers
BSP, aluminium SAE, aluminium BSP, steel SAE, steel
1/2” B12631 1/2” B10820 1/2” B13664 1/2” B11566
2 HOLES Ø11.0 THRO'

9
9.0

28.5
141.5 MAX

3
53.0

57.0

2
92.0

19.0 38.1 19.0

65.7 38.1

76.2

Where measurements are critical request certified drawings

ORDERING CODE EXAMPLE


2CFP** P 4W 4 S
Basic Code Seals
S = Nitrile (For use with most
2CFP60 = Cartridge Only
industrial hydraulic oils)
2CFP65 = Cartridge and Body SV = Viton (For high temperature and
most special fluid applications)
Adjustment Means
P = Leakproof Screw Adjustment
R = Handknob Adjustment
(See page 9-102 for dimensions)
Adjustable Flow Range
Port Sizes - Bodied Valves Only 4 = 4-40 litres/min. Std setting 30 litres
4W = 1/2” BSP 8T = 1/2” SAE 6 = 6-60 litres/min. Std setting 40 litres

We reserve the right to change specifications without notice

9-122.E