0% found this document useful (0 votes)
160 views1 page

M20 Tremix RDC

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 1

Mix Design Calculation

CONCRETE MIX DETAILS


Grade Of Concrete M20 Tremix 20 4 1.65 6.60
Maximum Size Of Aggregate 20 MM
Type Of Cement OPC-53
Concrete Mix For PUMP
Design Confirms To IS 456:2000
Degree Of Quality Control Good
Type Of Exposure Moderate

Design Mix Calculation

Target Mean Strength = ( fck + 1.65 X t )


= ( 20+ 1.65 X 4)
= 26.60

1. Cement Content (OPC) = 270 Kg

2. Fly Ash = 110 Kg


Microsilica = 0 Kg
GGBS = 0 Kg
3. Water / Cement Ratio = 0.40

4. Free Water Content = 152 Kg ( 380 X 0.40 )

5. Absolute Volume
Cement or Cementitious = 0.086 Cum ( 270 / 3.15 X 1.0 / 1000 )
Water = 0.152 Cum ( 152 / 1.0 X 1.0 / 1000 )
Fly Ash = 0.050 Cum ( 110 / 2.2 X 1.0 / 1000 )
M Silica = 0.000 Cum ( 0 / 2.2 X 1.0 / 1000 )
GGBS = 0.000 Cum ( 0 / 2.88 X 1.0 / 1000 )
Admixture = 0.0038 Cum ( 380 / 1.1 X 0.011 X 1.0 / 1000 )
Entrapped air = 0.000 Cum ( 0% of 1 Cum of concrete )
Total Absolute Volume = 0.292 Cum ( 0.086 + 0.152 + 0.050 + 0.000 + 0.000 + 0.0038 + 0.000 )
Volume of All in Aggregate = 0.708 Cum ( 1.0 - 0.292 )

Volume of Coarse Aggregate = 0.404 Cum ( 0.708 X 0.57 )


20 MM = 339 Kg/Cum ( 0.404 X 2.80 X 0.30 X 1000 )
10 MM = 786 Kg/Cum ( 0.404 X 2.78 X 0.70 X 1000 )
Fine Aggregate = 813 Kg/Cum ( 0.708 X 0.43 X 2.67 X 1000 )

Adjustment For Absorption By Aggregates :

Free Water to be used in 1 cum of Concrete = 152 Kg


Absorption by Coarse Aggregate 20MM = 0.00 Kg ( 339 X 0.0 / 100 )
10MM = 0.00 Kg ( 786 X 0.0 / 100 )
Absorption by Fine Aggregate = 0.00 Kg ( 813 X 0 / 100 )
Water requir for Absorption of Aggregate = 0.00 Kg ( 0.00 + 0.00 + 0.00 )
Total water to be used including absorbed water = 152 Kg ( 152 + 0.00 )
20 MM = 339 Kg/Cum ( 339.2 - 0.00 )
10 MM = 786 Kg/Cum ( 785.9 - 0.00 )
Fine Aggregate = 813 Kg/Cum ( 813.4 - 0.00 )

Admixture ( PCE base ) 1.1 % by weight of cement = 4.180 Kg

Total Density of Fresh Concrete = ( Cementitious + Aggregate + Admixture + Total water ) = 2475 Kg/Cum
Mix Proportion by weight

CEMENT FINE AGGREGATE COARSE AGGREGATE


380 813 1125
1 2.14 2.96

Note : Moisture correction on aggregate to be done at Batching Plant before concreting.

For RDC Concrete India Pvt. Ltd.