Pump Protection Valve

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Series TD

Type TDL
Type TDM
Automatic Recirculation Valve
for pump protection
Series TD
The SCHROEDAHL Automatic Recirculation Valve
is used for the pump protection of centrifugal pumps

Preamble
SCHROEDAHL is the largest supplier of Automatic
Recirculation Valves in the world. These ARVs, or pump
protection systems, are our principal products. During
the last 50 years we have supplied more than 50,000 of
these valves to satisfied customers all over the world.

Features
ƒƒ Automatic bypass operation

ƒƒ Modulating bypass operation

ƒƒ Low maintenance

ƒƒ Easy to install

ƒƒ Damping of system pulsations

ƒƒ Suitable for wide range of fluids

ƒƒ Self operated

ƒƒ Reduces plant investment and


operational costs

2
Application
The SCHROEDAHL Automatic Recirculation Valve is a high quality automatic solution to protect centrifugal
pumps against overheating, instability and cavitation, during zero process flow and low load conditions.

If the flow through the system is or falls below a certain level, the bypass system opens automatically and
the fluid is recirculated, providing the required minimum flow for the pump.

Special operation requirements, low load cases, complicated commissioning situations and the pressure
in the bypass line have an impact on the valve design and therefore are typically part of customers RFQ
information - SCHROEDAHL can offer solutions at a very high level.

The SCHROEDAHL automatic recirculation valve is therefore a high quality, cheaper and easier solution for
clean liquid pump protection - more cost effective than a conventional modulating control valve package.

Sectional drawing of an Automatic Sectional drawing of an Automatic


Recirculation Valve type TDM Recirculation Valve type TDL

Fig. 1 Fig. 2

3
Operation of the
Automatic Recirculation Valves

Fig. 3

Fig.4: Type TDL

Fig.5: Type TDM

4
Operation Range Definition The full minimum flow is bypassed when the main
The following two descriptions are typical of the check valve is seated. The bypass is fully closed
pump protection application: when the check valve is in its upper position,
thereby allowing full pump flow to the system.
1. Standard Operation Range Application:
The usual operation of pump protection valves
Flow sensitive modulating
is in the load range from 40% to 100% of the
rated process flow. The automatic valve will bypass control
The check valve moves upwards with increasing
handle the typical time-limited start-up and
main flow and downwards with decreasing flow.
shut-down phase with modulating bypass
The check valve transmits this motion via a lever
control operation.
to the bypass system (Fig. 4 and 5) and therefore
TDM valves at high pressure service may also
controls the bypass flow in a modulating position.
need an adequate bypass back pressure, e.g.
an orifice restriction in bypass line, to prevent
Type TDL
cavitation during bypass flow condition.
The TDL consists of the check valve section (Fig. 3)
2. Full Operation Range Application: with bypass configuration type L (Fig. 4). The lever
For high pressure TDM applications that will controls the position of the bushing, which in turn
operate over the full load range from 0 % to opens or closes the holes in the control head. The
100 % process flow, it will be necessary before minimum flow is thereby bypassed in a modulating
placing the order to evaluate special design way. Applicable for differential pressures up to 40
influences at the valve. Otherwise the application bar. Standard with non-return function.
will be classified as a standard range type.
Type TDM
For the high load range, depending on the existing
The TDM consists of the check valve section (Fig. 3)
bypass pressure level, it may be necessary to
with bypass configuration type M (Fig. 5). The
increase the bypass back pressure to prevent
movement of the lever is transmitted via a piston
cavitation, especially when the bypass is in
to the multi-stage vortex plug. The minimum flow
modulating action. Therefore the installation of a
is then bypassed in a modulating way over several
special back pressure valve BPV is recommended,
pressure reduction stages.
to ensure that the bypass pressure level is always
Applicable for differential pressures from 20 bar
at a suitable pressure level (an orifice plate will not
to 230 bar. The standard TDM design has a built-in
work).
bypass non-return function (~2 bar dp level
required).
Operation
The outlet main flow controls the check valve and
positions it in proportion to the flow. The stem of
the check valve transmits the motion via a lever
to the bypass. The bypass system regulates the
bypass flow in a modulating way and reduces the
pressure to the bypass outlet pressure level without
cavitation.

5
Manual Bypass Options for type TD
Automatic Recirculation Valves

Fig. 6

Options A:

A1 A2 A3

A4 A5

6
Options Information
Depending on the plant design or additional requirements, different options for the start-up/warm-up side
(A), or for the bypass trim side (B) can be selected.

Options A: A typical option is the start-up connection acc. (Fig. A1), to run low pressure flow to the process/
boiler for the start-up process, or to warm-up the neighboring pump/system.

Options B: Depending on the plant commissioning condition (dirt, spec. load case,…), a special
commissioning bypass trim set can be selected. The valve will then be shipped with the option bypass set
and also attached with the original bypass trim set (to be installed after commissioning).

Please contact SCHROEDAHL for additional information.

Options A: Options B:
Additional connection options (on request): Commissioning options for the
bypass side (on request):
A1: Start-up/warm-up above check valve
B-TDL: Commissioning bypass internals
A2: Start-up/warm-up below check valve.
for TDL valve (bigger clearances,
A3: Warm-up above check valve. modulating)

A4: Warm-up below check valve. B-TDM: Commissioning bypass internals


for TDM valve (continuous open, fixed flow
A5: Degassing Nozzle
coefficient, non-modulating, without
moving parts)

Options B:

B-TDL

B-TDM

7
Valve sizes Materials
Standard size from DN 25 (1“) to DN 300 (12“). Standard housing materials:
ASTM A105 (Carbon Steel), EN 1.0460
Pressure rating ASTM 316L (Stainless Steel), EN 1.4404
Pressure rating from PN 10 to PN 400 (class 150
The standard internals of the TD valves are
to class 2500). Other ratings upon request.
manufactured from stainless steel with a minimum
chrome content of 13%. Other forged materials for
Connections
housing and internals are available upon request.
Flanges are standard according to EN 1092-1 or
Selection of the seal material is done according
ASME. Flanges according to other standards (ISO,
to medium and temperature conditions. The
BS, JIS, NF) are available upon request. The inlet
housing material is selected according to medium,
and outlet connections can also be supplied with
pressure temperature conditions and customer
welding ends. The bypass connection is always
requirements.
flanged (for inspection purposes). Manual start-up
upon request. Draining or warm-up connections are
available, too.

Size Code Pressure Class Code Connection Code Configuration Code


05 = DN 25 (1”) 1 = PN 10 F = Flanges acc. to EN 1092-1 V = Vertical Installation
06 = DN 32 (1 1/4”) 2 = PN 16 U = Flanges acc. to ASME H = Horizontal Installation
07 = DN 40 (1 1/2”) 3 = PN 25 (Class 150) S = Welding Ends (not for bypass) A = Manual start-up
08 = DN 50 (2”) 4 = PN 40 J = Japanese Standard connection
09 = DN 65 (2 1/2”) 5 = PN 64 (Class 300) B = British Standard W = Standard oversized
10 = DN 80 (3”) 6 = PN 100 (Class 600) bypass
11 = DN 100 (4”) 7 = PN 160 (Class 900) CS = Carbon Steel
12 = DN 125 (5”) 8 = PN 250 (Class 1500) SS = Stainless Steel
13 = DN 150 (6”) 9 = PN 320 SD = Duplex Steel
15 = DN 200 (8”) 0 = PN 400 (Class 2500)
16 = DN 250 (10”)
17 = DN 300 (12”)

Example
TDM116UVW-CS: valve type TDM; 4“, class 600, ASME-Flanges, vertical installation,
housing material in carbon steel

8
Installation Information
The Automatic Recirculation Valve should be installed as close as possible to the centrifugal pump
discharge, preferably directly on the outlet of the pump.

To prevent low frequency shocks caused by pulsation of the medium, the distance between pump outlet
and valve inlet should not exceed 5 m with straight pipe run at the inlet. Exceptions have to be reviewed by
SCHROEDAHL.

Vertical installation is preferred, but horizontal installation is also possible on request. The TDL and TDM
valves operate at a low noise level and ensure a high reliability due to their sturdy design.

The recommended filter at the pump inlet should have a maximum mesh size of 0.3 to 0.5 mm. For
commissioning, we recommend a smaller filter mesh size (e.g. 0,1 mm).

Maintenance, Spares and Test


Maintenance instructions are available upon request or at www.schroedahl.com. Typically we recommend
an inspection after commissioning (a gasket set is then needed), and for two-year operation, we
recommend a bypass set (one complete bypass unit) for your stock.

A complete valve performance test run is recommended to be done together with the original pump. The
bypass Kv/Cv value test can be certified at our test facility.

Please contact SCHROEDAHL for additional information.

Place for BPV or


To the system Orifice

Straight pipe run 3 x DN As near as possible


to the tank

ARV

Tank

Best Distance: zero !


or
maximum 3 m with straight
pipe run of 2 x DN
No elbow allowed at inlet!

Fig. 7

9
Parts list

Housing Bypass L

Bypass

Housing assembly Bypass L


Item Description Item Description
01 Lower Body 11 Control Head
02 Upper Body 13 Lever
03 Stem Guide 14 Pivot Pin
04 Guide Bolt 15 Crank Arm
06 Spring 16 Control Bushing
07 Check Valve cpl. 23 Orifice Bushing
07.1 Check Valve 31 O-Ring
07.2 Stem 36 O-Ring
08 Liner or Venturi-Ring 37 Spring
09 Bypass Branch 38 Bottom Ring
25 Guide Pin
26 Bolt
27 Bolt
28 Hexagon Nut
29 Hexagon Nut
30 O-Ring

10
Bypass M Manual Start-up (Option A1, example)

Bypass M Manual Start-up


Item Description Item Description
10 Vortex Bushing 10 Vortex Bushing
11 Control Head 18 Vortex Plug
12 Vortex Plug 19 Holder
13 Lever 20 Pin
14 Pivot Pin 23 Orifice Plate
15 Relief Bushing 31 O-Ring
16 Relief Piston 32 O-Ring
21 Threaded Ring 36 O-Ring
23 Bypass Orifice / Cone
31 O-Ring
32 O-Ring
33 O-Ring
33.1 Glyd-Ring
34 O-Ring
34.1 Glyd-Ring
35 O-Ring
35.1 Glyd-Ring
36 O-Ring

11
Sizing and selection

Nominal size and pressure class of the Automatic Notes


The following table is only to be used
Recirculation Valve should preferably be the same as
as an indication. Other bypass sizes
the outlet of the pump. available upon request. For final valve
selection please contact our office.

Size Code 05 06 07 08 09 10 11 12 13 15 16 17

DN P, R (mm) 25 32 40 50 65 80 100 125 150 200 250 300

DN P, R (inch) 1 1¼ 1½ 2 2½ 3 4 5 6 8 10 12

Max. flow P,R for TDL


12 18 35 55 105 175 270 400 530 880 1100 1500
and TDM valves (m3/h)
Bypass L /M DN (mm) 25 25 25 25 40 40 50 50 65 80 100 125

see Fig.4/5 DN (inch) 1 1 1 1 1½ 1½ 2 2 2½ 3 4 5

Max. Bypas flow


18 18 18 18 40 40 65 65 115 180 280 480
P-B (m3/h)

Example valve selection

Kv = Qmin x S.G. Qmin = Minimum flow in m3/h, s.g. specific gravity in kg/dm3
∆p
Δp = Differential pressure in bar over the bypass at minimum flow

Conditions: Pump DN 100, PN 100, main flow is 180 m3/h, required bypass flow is 40 m3/h,
S.G. is 0.95, Δp is 70 bar at Qmin.

Selection: a. The main flow is in the range of a valve DN 100.


b. The ∆p at minimum flow is ≥ 40 bar, this means that we have to select a valve type TDM.
c. Kv = 40 x 0.95 / 70 = 4.8 m3/h , this means a valve DN 100 with a bypass DN 50 can be
used as the maximum Kv is 5.4 m3/h.

12
Automatic Recirculation Valve
Technical Data

Customer: Data sheet:


Enquiry no.:
Prior reference: Quantity:
Order no.:
Project:

Automatic Recirculation Valve type:

Valve inlet DN PN Fl.Code.:


Valve outlet DN PN Installation:  vertical  horizontal
Bypass outlet DN PN Paint:
Start-up DN PN Start-up  above  below check valve

Mat.-/test certificates:
Materials
Housing: Internals: Seals:

Medium Operating temp. [°C]:


S.G. [kg/m³]: Design temp. [°C]:

H0 = m
QM = m³/h HM = m Suction pr. pv bar
Q100 = m³/h H100 = m Differential pr. (p1-pn) bar
Qmax = m³/h HQmax = m Back pressure pN bar
QA = m³/h HA = m Back pressure pA bar

Notes:

Revision Date Description Name Signature

H0 Rangeability Q
P2 tank
HM
H50 Duty point
Qmax
Qmin
H100
Head H in m

HQmax
PN
Q
bypass-branch

QM 50 100 Pv
P1
Flow Q in %
pump

13
Dimensions

EN Size DNR/DNP PN DNB L (mm) S (mm) H (mm) Weight (kg)


051-052-053-054 10-16-25-40 190 153 73 15
055 25 63 25 250 182 90 32
056 100 250 182 90 32
061-062-063-064 10-16-25-40 190 153 73 17
065 32 63 25 250 190 90 30
066 100 250 190 90 30
071-072-073-074 10-16-25-40 200 155 75 19
075-076-077 40 63-100-160 25 260 190 90 34
078 250 300 215 120 47
081-082-083-084 10-16-25-40 230 163 90 26
085 63 300 185 115 48
50 25
086-087 100-160 300 193 110 56
088 250 350 223 130 85
091-092-093-094 10-16-25-40 290 184 110 37
095 63 340 219 125 56
65 40
096-097 100-160 340 227 125 83
098 250 400 260 145 89
101-102-103-104 10-16-25-40 310 191 115 48
105 63 380 233 140 69
80 40
106-107 100-160 380 240 140 85
108 250 450 265 165 125
111-112-113-114 10-16-25-40 350 221 125 72
115 63 430 258 155 105
100 50
116-117 100-160 430 266 155 150
118 250 520 300 190 200
121-122-123-124 10-16-25-40 400 266 135 100
125 63 500 280 175 183
125 50
126-127 100-160 500 291 175 223
128 250 600 321 215 345
131-132-133-134 10-16-25-40 480 295 165 195
135 63 550 350 190 255
136 150 100 65 550 355 190 270
137 160 585 355 200 275
138 250 700 405 250 480
151-152-153-154 10-16-25-40 600 395 200 355
155 63 650 405 215 467
200 80
156-157 100-160 680 430 225 550
158 250 830 485 290 920
161-162-163-164 10-16-25-40 730 475 240 460
165 63 775 520 260 680
250 100
166-167 100-160 800 560 270 970
168 250 900 560 310 1470
171-172-173-174 10-16-25-40 850 530 280 1020
175 63 900 550 300 930
300 125
176-177 100-160 1050 650 360 1600
178 250 1200 720 420 2100

14
P = Pump outlet
R = Pipeline/ process
B = Bypass connection
(A = Start-up connection as option)

ASME Size DNR/DNP PN DNB L (mm) S (mm) H (mm) Weight (kg)


073 150 200 155 75 19
075 300 260 190 90 34
076 1½" 600 1" 260 190 90 34
077 900 300 200 110 34
078 1500 310 215 120 47
083 150 230 163 90 26
085 300 300 185 115 48
086 2" 600 1" 300 193 110 56
087 900 340 203 130 56
088 1500 350 233 130 85
093 150 290 174 110 37
095 300 340 199 125 56
096 2½" 600 1½" 340 220 125 83
097 900 380 230 140 83
098 1500 400 250 145 89
103 150 310 191 115 48
105 300 380 220 140 69
106 3" 600 1½" 380 240 140 85
107 900 410 250 150 85
108 1500 450 275 165 125
113 150 350 211 125 72
115 300 430 240 155 105
116 4" 600 2" 430 266 155 150
117 900 450 280 160 150
118 1500 520 300 190 200
123 150 400 266 135 100
125 300 500 290 175 183
126 5" 600 2" 500 300 175 223
127 900 525 310 185 223
128 1500 650 341 235 345
133 150 480 295 165 195
135 300 550 350 190 255
136 6" 600 2½" 550 355 190 270
137 900 585 355 200 275
138 1500 700 405 250 480
153 150 600 395 200 355
155 300 650 405 215 467
156 8" 600 3" 680 430 225 550
157 900 700 430 225 550
158 1500 880 485 310 920
163 150 730 475 240 460
165 300 775 520 260 677
166 10" 600 4" 800 560 270 970
167 900 800 560 270 970
168 1500 980 570 340 1470
173 150 850 530 280 1020
175 300 900 550 300 930
176 12" 600 5" 1050 650 360 1600
177 900 1050 650 360 1600
178 1500 1250 720 440 2100

15
©2016 XYQOM GmbH · www.xyqom.net / rev. 2016_UK_005