IONSOFT™ Maxi (Berkesoft) : Cost-Efficient Softeners

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

IONSOFT™ Maxi (Berkesoft)

Cost-efficient softeners

The IONSOFT Maxi is a cost efficient softener range based on ion Exchange resins technology that
can be used for industrial applications.
It is designed with upflow counter-current regeneration to optimize OPEX.
• 5 vessel sizes.
• Up to 4 units in parallel
• Up to 2 units in Duty/Stand-by

Flow rates
from 1 to
80 m3/h

FEATURES & BENEFITS


� U
 ser-friendly controller with LCD display
integrated in the Control valve
� R
 egeneration can be triggered manually or
automatically
� A
 utomatic regeneration is based on Volume
and time
� O
 ptimized usage of regeneration salt: upflow APPLICATIONS
counter-current regeneration and proportional
regeneration when resins are only partially �  lass washing
G
exhausted � Cleaning and rinse water
� P
 ossibility to have duty/stand-by configuration � Laundry
with 2 vessels � Reverse Osmosis feed water pre-treatment (eg.
� U
 p to 4 units running in parallel: continuous before Sirion)
production � Cooling towers

HYDREX® CHEMICALS RELATED SERVICES


Hydrex™ 7110 water treatment Local after-sales service and support teams
chemicals from Veolia Water Technologies offer preventative and corrective maintenance
and salt pellets should be used for optimized programs to ensure the long-term, efficient
operation. operation of installed plant.

WATER TECHNOLOGIES
IONSOFT™ Maxi TECHNICAL PERFORMANCES

System operating parameters and dimensions


Model single vessel Unit Maxi 90 Maxi 120 Maxi 140 Maxi 230 Maxi 350
Min production flowrate m3/h 1 1 1.2 2.1 2.8
Max production flowrate m3/h 9 10.5 11.5 19 20
Capacity kgCaCO3 4.6 6.0 7.1 11.7 17.5
Length m 1.40 1.70 1.70 1.80 1.90
Width m 0.70 1.05 1.05 1.05 1.10
Height m 1.63 1.93 1.93 2.00 2.25
Connections - Rp 2” BSPT Rp 2” BSPT Rp 2” BSPT Rp 2” BSPT Rp 2” BSPT
Model Duty/ Stand-by Unit Maxi 2-90A Maxi 2-120A Maxi 2-140A Maxi 2-230A Maxi 2-350A
Min production flowrate m3/h 1 1 1.2 2.1 2.8
Max production flowrate m3/h 9 10.5 11.5 19 20
Capacity kgCaCO3 9.3 12.0 14.3 23.4 35.0
Length m 1.93 2.25 2.28 2.45 2.55
Width m 0.75 1.05 1.05 1.05 1.15
Height m 1.75 2.05 2.05 2.03 2.28
Connections - Rp 2” BSPT Rp 2” BSPT Rp 2” BSPT Rp 2” BSPT Rp 2” BSPT
Model 2 vessels in parallel Unit Maxi 2-90P Maxi 2-120P Maxi 2-140P Maxi 2-230P Maxi 2-350P
Min production flowrate m3/h 2 2 2.4 4.2 5.6
Max production flowrate m3/h 18 21 23 38 40
Capacity kgCaCO3 9.3 12.0 14.3 23.4 35.0
Length m 2.05 2.60 2.60 2.75 3.10
Width m 1.20 1.63 1.60 1.75 1.75
Height m 1.63 1.90 1.93 2.00 2.25
Connections - Rp 2” BSPT Flange DN65 Flange DN65 Flange DN80 Flange DN80
Model 3 vessels in parallel Unit Maxi 3-90 Maxi 3-120 Maxi 3-140 Maxi 3-230 Maxi 3-350
Min production flowrate m3/h 3 3 3.6 6.2 8.4
Max production flowrate m3/h 27 31.5 34.5 57 60
Capacity kgCaCO3 13.9 18 21.4 35.1 52.5
Length m 2.58 3.90 3.90 3.95 4.10
Width m 1.35 1.83 1.83 1.98 2.10
Height m 1.63 1.90 1.93 2.00 2.25
Connections - Flange DN65 Flange DN80 Flange DN80 Flange DN100 Flange DN100
Model 3 vessels in parallel Unit Maxi 4-90 Maxi 4-120 Maxi 4-140 Maxi 4-230 Maxi 4-350
Min production flowrate m3/h 4 4 4.8 8.4 11.2
Max production flowrate m3/h 36 42 46 76 80

In keeping with the progressive nature of the company, we reserve the right to amend details without notice. VEOLIA/SOLYS/IONSOFT™ Maxi/04.19 (190196)
Capacity kgCaCO3 18.4 24 28.4 46.8 70
Length m 3.25 4.80 4.80 4.80 4.90
Width m 1.35 1.83 1.83 1.98 2.10
Height m 1.63 1.90 1.93 2.00 2.25
Connections - Flange DN80 Flange DN100 Flange DN100 Flange DN125 Flange DN125
Regeneration (per vessel)
Water consumption per regeneration L 500 660 770 1265 1925
Salt consumption per regeneration kg 11.2 14.4 17.2 28.1 42.0

Feed Water requirements Environmental conditions


Parameter Unit Value Parameter Unit Value
Min water temperature °C 5 Min ambient temperature °C 5
Max water temperature °C 25 Max ambient temperature °C 35
Min inlet pressure bar 2.5 Indoor installation in a non-corrosive atmosphere.
Max inlet pressure bar 6
Feed water must have a quality equivalent to potable water, free from
Power requirements
organic contamination and suspended solids.
Voltage AC 100-240V / DC 15V
Feed water must have a quality equivalent to potable water, colorless,
Frequency 50/60 Hz
free from organic contamination, chlorine, Iron, manganese and
suspended solids. Raw water shall not contain hardness stabilizing Phase 1
agents and must not be over-saturated with gas.

[email protected]
www.veoliawatertechnologies.com