Minipurge Interface Unit (Miu/D) Manual Ml303
Minipurge Interface Unit (Miu/D) Manual Ml303
Minipurge Interface Unit (Miu/D) Manual Ml303
ML303
Contents
1. Specification Sheet
2. General Information
3. Installation
4. Commissioning
5. Maintenance
6. Fault Finding
7. Spare Parts List
8. Certificates
9. Drawings and Diagrams
10. Project Specific Data
2. General Information
Application Suitability
• MiniPurge Interface Units (MIU) are certified for use in Hazardous Locations, where the
Hazardous Location is non-mining (i.e. above ground) and where the hazard is caused by
flammable gases, vapours or combustible dusts.
• The MIU can be in Zone 1, 2 for gas and / or Zone 21, 22 for dust, or Class I, Division 1, 2
for gas and / or Class II, Division 1, 2 for dust Hazardous Locations.
• MiniPurge Interface Unit may be used for hazards of most gas or dust groups. However,
apparatus associated with the MIU, such as intrinsically safe signalling circuits and other
flameproof enclosures containing switching devices may be limited in their own group. The
certification documentation supplied with such devices must be checked to ensure their
suitability.
• As with all equipment for use in Hazardous / Classified areas, local working and installation
practices for Hazardous Location equipment must be adhered to when installing and
maintaining this equipment. This equipment must only be installed by personnel who are
aware of the requirements for installation of electrical equipment within hazardous locations.
• MIUs are designed to be controlled primarily with compressed air. Where compressed inert
gases are used (Nitrogen, for example) the user must take suitable precautions so that the
build up of the inert gas does not present a hazard to health. Consult the Control of
Substances Hazardous to Health (COSHH) data sheet for the gas used or relevant national
requirements.
• The following materials are used in the construction of MiniPurge Interface Units. If
substances that will adversely affect any of these materials are present in the surrounding
environment, please consult EXPO for further guidance:
▪ Stainless Steel
▪ Brass
▪ Aluminium ( Ex d / Xp enclosure contains <1% magnesium)
▪ Nitrile (‘O’ Rings)
• This equipment is designed for use under normal industrial conditions of ambient
temperature, humidity and vibration. Please consult EXPO before installing this equipment
in conditions that may cause stresses beyond normal industrial conditions.
System Description
• EXPO range of MIUs is designed for use on a wide range of applications and enclosures.
They are to be used in conjunction with a system, which provides the MIU with the
necessary signals in order to produce “Volt Free / Dry Contact” alarm signals and power
switching to the pressurized enclosure.
• All units are built into flameproof / explosionproof enclosures. The joint between the lid and the
enclosure forms a threaded flamepath.
ML303 | v19
Expo Technologies UK Expo Technologies US Expo Technologies China
Page
T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858 1
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
• Each MIU is supplied with limited entries (refer to the drawing section for details). When
additional entries have been ordered, the following restriction will apply:
o Minimum space between entries;
▪ 35mm, (1.38”) for M20 or ½” NPT
▪ 40mm, (1.58”) for M25 or ¾” NPT
o Entries should not be placed so close to the side that an internal surface, parallel to the
thread of the entry, is cut when a threaded entry is machined.
• For USA (NEC) or Dual standard conformity, NPT entries must be used.
• For IEC / ATEX, metric or NPT entries may be used. NPT and Metric entries must not be
mixed on the same enclosure.
• The standard MIU is supplied with NPT entries.
• Alternative versions of MIU are available which use intrinsically safe or increased safety
switching systems to control the MIU functions. These are only available to special order.
Contact the sales office for details.
MIU/dA AMU-9AA1-510
Power contactor: 4PNO/20A//440Vac*
Alarm switch: SPCO3A/250Vac*
110Vac Coil for electrical override when required
AMU-9AA1-511
Power contactor: 4PNO/20A/440Vac*
Alarm switch: SPCO3A/250Vac*
230Vac Coil for electrical override when required
AMU-9AA1-518
Power contactor: 4PNO/20A/440Vac*
Alarm switch: SPCO3A/250Vac*
24Vdc Coil for electrical override when required
MIU/dX AMU-AAA1-610
Power contactor: 4PNO/20A/440Vac*
Signal relay: 4PNO/5A/250Vac*
Alarm switch: SPCO3A/250Vac*
110/230Vac Dual voltage supply
MIU/dT AMU-BAA1-610
Power contactor: 4PNO/35A/600Vac*
Signal relay: 4PNO/5A/250Vac*
Alarm switch: SPCO3A/250Vac*
110/230Vac Dual voltage supply
*IEC rating shown, refer to drawings for detailed information on ratings including UL and CSA.
ML303 | v19
Page Expo Technologies UK Expo Technologies US Expo Technologies China
2 T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
3. Installation
• MiniPurge Interface Units are designed to be mounted in hazardous / classified locations. The
MIUs are suitable for use in the following area classification. Please note that the gas group
varies for European / USA area classifications.
IEC / Europe Zone 1, 2 Gas Group IIC
Zone 21, 22 Dust
USA/ Canada Class I, Divisions 1 & 2 Gas Groups B, C & D
Class II, Divisions 1 & 2 Dust Groups E, F & G
• The MiniPurge Interface Unit shall be installed in accordance with relevant standards, such
as EN 60079-14 or NEC 500 or 505, and / or any local codes of practice that are in force.
• The distance required free from obstructing the flamepath for ATEX / IEC:
▪ Gas Group IIC is at least 40mm (15/8”).
▪ Gas Group IIB is at least 30mm (1 11/64”)
▪ Gas Group IIA is at least 10mm (17/64”)
• Cable glands, conduit or other cable entry devices shall be appropriately certified and
suitable for the cable and the conditions of use and be installed in accordance with the
manufacturer’s instructions. EN 60079-14 contains guidance on the selection of appropriate
cable glands.
• When the MiniPurge Interface Unit is to be used in
conjunction with a MiniPurge Purge and Pressurization
System, it shall be connected in accordance with the
instructions given in this manual.
• The external earth connection of the MiniPurge Interface
Unit shall be connected to earth using a minimum 4mm2 /
12 AWG conductor.
• It is recommended that 6 mm / ¼” dia non-crushable pipe
with appropriate 1/8” NPT fittings (not supplied) are used to
connect the MIU with the MiniPurge system.
To order suitable fittings and pipe to connect the two units
see Spare Parts - Additional Items.
• MiniPurge Interface Units are supplied with NPT tapped
cable entries as standard.
• In the MIU/dA, Power Contactor is operated directly by the
pneumatic (input) Actuator.
• In the MIU/dX, connect the external voltage between the
terminals N and 115 or 230 terminals, for 115 V or 230 V ac
Power Supply respectively.
• In the MIU/dT, connect the external voltage to the L and N
terminals, and select the appropriate supply voltage using the
voltage selector switch, for 115V or 230V ac supply
respectively.
• Refer to the drawing section of this manual for the wiring
schematic of the unit to be installed. Also refer to Project
Specific Data for possible additional information.
ML303 | v19
Expo Technologies UK Expo Technologies US Expo Technologies China
Page
T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858 3
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
4. Commissioning
• Once the MIU has been installed, the cable glands, conduit, earth connections and any other
connections (e.g. pneumatic) shall be inspected for correct installation before the unit is put
into service.
• Apply a thin, even layer of the grease (provided) onto the threads of the lid.
• The lid shall be correctly fitted, and the lid locking device secured.
• If the commissioning is being carried out in the Hazardous Location, appropriate precautions
must be taken to prevent an incident. A relevant “Hot Work Permit” or similar must be obtained
from the appropriate authority and regulations followed.
ML303 | v19
Page Expo Technologies UK Expo Technologies US Expo Technologies China
4 T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
5. Maintenance
EXPO suggests at a minimum of every six months and /or a maximum of 2 years dependent on
site conditions, to follow the maintenance routine described below:
• Inspect the condition of the enclosure and associated cable glands, conduit for any signs of
damage.
• Inspect the condition of the thread and the lid locking device for any signs of corrosion or
damage.
• There are no user serviceable parts within the MIU system apart from those mentioned in
this manual.
• Repeat the commissioning tests to check correct operation of the system.
• Check that the air supply quality, where applicable, is still acceptable.
• Check that the system has not been modified in an unauthorised manner.
• Check that the certification labelling is legible and that the system is suitable for the
hazardous location.
6. Fault Finding
Refer to the table below to solve any malfunction.
Problem Potential Cure
The Alarm/Pressurized contact • Check the pneumatic connection from the MiniPurge for
fails to operate. leakage / blockage.
• Check the operation of the pneumatic feed through as
follows:
• Unscrew the air connection to the Feed Through Actuator
on the side of the MIU and use a small terminal
screwdriver to manually depress the piston inside the
feed through.
• Pressing the piston should transfer the motion to the
switch within the MIU, and the change-over action of the
switch should be observed with a continuity tester.
The power switching contacts • The contactor is directly operated by the pneumatic Feed
do not close. (MIU/dA units) Through Actuator. Operation should be tested as outlined
for the alarm contact above.
The power switching contacts • Check that there is power supplied to the MIU
do not close (MIU/dX and • Check operation of the pneumatic Feed Through
MIU/dT units) Actuator as above for the Alarm/ Pressurized contact.
• Check the voltage selection matches that of the supply
• Check the fuse in the MIU. (Refer to the circuit diagram
for the fuse rating.)
ML303 | v19
Expo Technologies UK Expo Technologies US Expo Technologies China
Page
T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858 5
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
7. Spare Parts List
Attention: When ordering spare parts include the serial number of the unit.
Item Part Number
Type dA
Contactor (110 Vac Coil) 4PNO/20A/440Vac ECT-T000-064
Contactor (230 Vac Coil) 4PNO/20A/440Vac ECT-T000-063
Type dX
Contactor (24 Vac Coil) 4PNO/20A/440Vac ECT-T000-065
Relay 4PNO/5A/250Vac ECT-T000-025
Fuse Assembly, 250mA EFH-0400-001
Type dT
Contactor (24 Vac Coil) 4PNO/35A/600Vac ECT-T000-024
Relay 4PNO/5A/250Vac ECT-T000-025
Fuse, 630mA EFU-C006-301
Additional items
Direct Mounting Kit, for dA & Size 1 MiniPurge only KMP-2600-000
ensure MIU is ordered with additional holes E & F
Grease PCB 10g sachet S0130/001
Mechanical Manual Override for dA only AGM-GM00-428
Mechanical Manual Override for dX & dT. AGM-GM00-452
Electrical Manual Override UL MO/UL
Electrical Manual Override ATEX, IEC MO(BOX) or MO(PM)
Pipe fittings to connect MiniPurge to MIU , contains; KMP-3MIU-S00
4 x 1/8” NPT to 6mmOD, Stainless Steel
Pipe 6mmOD in Stainless Steel, sold in 1m (39”) lengths HTS-0601-500
Plug, ½” NPT, Brass, Sira 00ATEX1073U TTP-4400-0B0
ML303 | v19
Page Expo Technologies UK Expo Technologies US Expo Technologies China
6 T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
8. Certificates
For limitations and conditions of use refer to the applicable certificate at the back of this
manual:
ML303 | v19
Expo Technologies UK Expo Technologies US Expo Technologies China
Page
T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858 7
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
10. Project Specific Data
Recorded below are the drawing numbers detailing items specific to the project the MIU/d is
supplied to.
ML303 | v19
Page Expo Technologies UK Expo Technologies US Expo Technologies China
8 T: +44 (0) 20 8398 8011 T: +1 (440) 247 5314 T: +86 532 8906 9858
E: sales@expoworldwide.com E:sales.na@expoworldwide.com E: qingdao@expoworldwide.com
UNSPECIFIED NO DEC PLACE ±0.5
DIMENSIONS IN mm The contents of this drawing / document are Copyright ã Expo Technologies Limited. They are to be treated as confidential and are returnable
3rd ANGLE TOLERANCES 1 DEC PLACE ±0.2
upon request. They are not to be copied or communicated in part or in whole without written consent from Expo Technologies Limited, neither
PROJECTION DO NOT SCALE 2 DEC PLACE ±0.1
are they to be used in any way against our interests.
FLATNESS TO BE LESS THAN 0.4mm OVER ANY 100mm LENGTH
ITEM QTY DESCRIPTION
5 2 8 3 4
1 1 Ex d / EXPLOSIONPROOF ALUMINIUM HOUSING
2 1 CONTACTOR CON1:
UL AND CSA:
3 PHASE: 3HP 480Vac
GENERAL USE: 12A 300Vac
IEC:
1
AC1 20A 440Vac T<40°C
AC1 16A 440Vac T<55°C
AC3 4kW 400Vac T<55°C
AC3 9A 400Vac T<55°C
6 COIL 50/60Hz at 40°C:
110Vac FOR MIU AMU-9AA1-510
230Vac FOR MIU AMU-9AA1-511
24Vdc FOR MIU AMU-9AA1-518
3 1
TERMINAL RAIL
4 3
7
ALARM/PRESSURIZED TERMINAL BLOCK
SW1 5 2
EARTH TERMINAL BLOCK
6 1
POWER INTERLOCK ACTUATOR
7 1
ALARM/PRESSURIZED ACTUATOR FOR SW1
UL CSA AND IEC: 6A 125Vac OR 3A 250Vac
8 1
RATING LABEL
WIRE SIZE FOR CONTACTOR AND TERMINALS: 2.5mm² (14 AWG) MAX
NOTES
1. EXPO EXPLOSIONPROOF PRODUCTS ARE DESIGNED TO FULFIL THE APPLICABLE REQUIREMENTS OF IEC,
ATEX & NEC ARTICLE 500 HAZARDOUS (CLASSIFIED) LOCATION INSTALLATIONS.
CON1
2. THIS MINIPURGE INTERFACE UNIT IS SUITABLE FOR USE IN THE FOLLOWING HAZARDOUS LOCATIONS:
1 3 5 13 A1 POWER INTERLOCK
SIGNAL 2 barg (30 CLASS I DIV 1 GROUP B, C & D, UL COMPLIANCE
E E C P A
psi) MINIMUM FROM CLASS II DIV 1 GROUP E, F & G NEMA 4, 7 & 9
2 4 6 14 A2 MINIPURGE
SIRA 02ATEX1129 II 2 GD
110/230 Vac COIL -
ZONE 1 GAS GROUP IIC Ex d IIC T6 (Tamb -20°C TO +40°C) OR T5 (Tamb -20°C to +55°C)
POWER SUPPLY SEE NOTE 4
85-254 Vac 50-60 Hz ZONE 21 DUST Ex tD A21 IP6X T80°C OR T95°C (Tamb -20°C to +55°C)
COMMON
IECEx SIR07.0008
PRESSURIZED
ALARM/PRESSURIZED ZONE 1 GAS GROUP IIC Ex d IIC T6 (Tamb -20°C TO +40°C) OR T5 (Tamb -20°C to +55°C)
SW1
SIGNAL
PRESSURE ALARM
2 barg (30 psi) MINIMUM ZONE 21 DUST Ex tD A21 IP6X T80°C OR T95°C (Tamb -20°C to +55°C)
FROM MINIPURGE 3. WEIGHT: 3kg (6.5lbs)
4. COIL IS ONLY USED AS PART OF ELECTRICAL MANUAL OVERRIDE, WHEN REQUIRED.
LID CLAMP
30 [1 3/16"]
= =
130 [5 1/8"]
95 [3 3/4"]
45 [1 3/4"]
2 CABLE ENTRIES
1/2" NPT
12 [1/2"]
60
[2 3/8"]
57
[2 1/4"]
= 51 [2"] =
= 101.6 [4"] =
FIXINGS IN 2 PLACES
MAX ø8 [ø5/16"]
TO SUIT MOUNTING HOLE
ø10 [ø3/8"] IN MIU.
SEE NOTE (b)
95 [3 3/4"]
NOTE:
ASSEMBLY NOTES:
F
1. HOLES 1, 2 &3 SHOULD BE INLINE.
2. FACE OF THE ACTUATOR HOUSING SHOULD BE EXPOSED (REMOVE ANODISE) AS PER DRAWING.
3. GRUB SCREWS SHOULD BE IN FLUSH WITH THE OUTER DIAMETER OF THE LOCK.
4. CHECK FOR CONDUCTIVITY IN THE LANUAL OVERRIDE LOCK & MIU BOX.
THE RESISTANCE SHOULD BE LESS THAN 1 OHM.
5. TO REMOVE THE KEY THE OVERRIDE SWITCH WILL REQUIRE A MINIMUM OF 70mm [2.8"]
OF CLEAR SPACE BETWEEN THE BARREL AND ANY EXTERNAL FACE.
E
D
ANODISING NEEDS TO BE
REMOVED TO CREAT
CONDUCTIVITY.
SECTION B-B
SCALE 1 : 1
B
30 [ 1.2"]
B B
1 2 3 4 5 6 7 8
* Wire colours are not necessarily common to all cable varieties. Always check
the pinout of the connector.
Transmit and receive are noted as data flows out of the network interface card on
the PC. Obviously, Transmit and Receive are the reverse on the hub.
2
SCHEDULE
1 EC TYPE-EXAMINATION CERTIFICATE
2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94/9/EC EC TYPE-EXAMINATION CERTIFICATE Sira 02ATEX1129
Issue 6
3 Certificate Number: Sira 02ATEX1129 Issue: 6
4 Equipment: Minipurge Interface Unit Type MIU/d 13 DESCRIPTION OF EQUIPMENT
5 Applicant: Expo Technologies Limited The Minipurge Interface Units comprise a flameproof enclosure with various internal equipment
dependent upon the application. The enclosures used are either Expo dA, dX, dT, dK or dN depending
6 Address: Unit 2, The Summit upon the size or type required.
Hanworth Road
Sunbury on Thames The range of enclosures have the same basic geometry but are of differing sizes. The enclosures are
Surrey TW16 5DB all essentially square in profile with a circular lid. The joint between the lid and the enclosure forms a
UK threaded flamepath; the lid is secured by means of a locking device. There is an option to include
bosses for the installation of internal apparatus. Mounting is by means of two or more tapped holes in
7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and the rear face or by the use of mounting pads. Two or more protruding mounting lugs are optional.
the documents therein referred to.
External earthing facilities comprise M4 (or larger) earth studs on the surface of the box or mounting
8 Sira Certification Service, notified body number 0518 in accordance with Article 9 of Directive 94/9/EC pads; the studs are equipped with nuts, washers and anti-rotation lugs. Alternatively or additionally,
of 23 March 1994, certifies that this equipment has been found to comply with the Essential Health and external earthing may be provided at the mounting lug(s). Tapped holes in the earth lugs between
Safety Requirements relating to the design and construction of equipment intended for use in anti-rotation ribs are optional.
potentially explosive atmospheres given in Annex II to the Directive.
Internal earthing is provided either by a tapped hole in the internal rear face or by means of
The examination and test results are recorded in the confidential reports listed in Section 14.2. conventional rail-mounted earth terminals secured to the internal rear face.
9 Compliance with the Essential Health and Safety Requirements, with the exception of those listed in the “O” ring seals may be used to enhance the ingress protection rating.
schedule to this certificate, has been assured by compliance with the following documents: The enclosures may be manufactured from copper-free aluminium, grey iron, S.G. iron, phosphor
EN 60079-0:2012/A11:2013 EN 60079-1:2014 EN 60079-31:2014 bronze, gunmetal or stainless steel.
The above list of documents may detail standards that do not appear on the UKAS Scope of Accreditation, but have been added Cable entry facilities are provided on the sides and rear of the enclosure.
through Sira’s flexible scope of accreditation, which is available on request.
To allow the control of the internal equipment, linear feed through devices, Type C9L, may be utilised
10 If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to special as required. These are installed in the areas designated for cable entry devices. The feed through
conditions for safe use specified in the schedule to this certificate. device comprises a threaded barrel with a central shaft secured with circlips at each end. The device is
11 This EC type-examination certificate relates only to the design and construction of the specified secured in the wall (or rear) of the enclosure by means of a locknut and optional thread sealing
equipment. If applicable, further requirements of this Directive apply to the manufacture and supply of washer. An optional external “O” ring seal around the shaft, outside the flamepath, can improve the IP
this equipment. rating. The feed through can be fitted with unspecified external operators, e.g. push-buttons.
The scope of this certificate covers a range of internal components which may be installed within the
12 The marking of the equipment shall include the following:
flameproof enclosure, including limitations with respect to their location. Typical internal equipment
For Types dA, dX and dT For Types dK and dN Breather drain installed comprises terminals, switches, contactors, relays and some intrinsically safe equipment. Although this
certificate allows the inclusion of this intrinsic safety equipment, it does not endorse their intrinsic
II 2 G D II 2 G D II 2 G D safety properties (see certificate conditions).
Ex db IIC T* Gb Ex db IIB + H2 T* Gb Ex db IIB+H2 T3 Gb
Variation 1
Ex tb IIIC T*°C Db Ex tb IIIC T*°C Db
Ta = -20°C to +*°C Ta = -20°C to +*°C Ta = -20°C to +55°C This variation introduced the following changes:
* The temperature markings are T6 and T80°C for an ambient temperature range of -20°C to +40°C or T5 and T95°C for an
ambient temperature range of -20°C to +55°C i. The company name was changed from Expo-Telektron Safety Systems Ltd. to Expo Technologies
Ltd. together with a change of company logo.
ii. The Minipurge Interface Unit Type MIU/d was allowed to be used in the presence of combustible
dust; the marking of the equipment to include the following:
Project Number 70006555 A C Smith
Certification Manager II 2 G D IP6X
This certificate and its schedules may only be
reproduced in its entirety and without change.
Sira Certification Service This certificate and its schedules may only be Sira Certification Service
Unit 6, Hawarden Industrial Park, reproduced in its entirety and without change.
Unit 6, Hawarden Industrial Park,
Hawarden, CH5 3US, United Kingdom
Page 1 of 4 Hawarden, CH5 3US, United Kingdom
Form 9400 Issue 1 Tel: +44 (0) 1244 670 900 Page 2 of 4 Tel: +44 (0) 1244 670 900
Fax: +44 (0) 1244 539 301 Form 9400 Issue1 Fax: +44 (0) 1244 539 301
Email: ukinfo@csagroup.org
Email: ukinfo@csagroup.org
Web: www.csagroupuk.org
Web: www.csagroupuk.org
SCHEDULE SCHEDULE
Issue 0
The drawings associated with this Issue were replaced by those listed in Issue 3.
Issue 1
The drawings associated with this Issue were replaced by those listed in Issue 3.
Issue 2
The drawings associated with this Issue were replaced by those listed in Issue 3.
Issue 3
Drawing No. Sheet Rev. Date Description
EP90-3dA 1 of 1 6 21 Nov 06 Ex d Boxes Dimensions Key
EP90-2dA 1 of 1 3 21 Nov 06 dA Box
EP90-8A 1 of 1 4 05 Feb 07 dA Box Contents
EP90-2dX 1 of 1 2 21 Nov 06 dX Box
EP90-8X 1 of 1 4 05 Feb 07 dX Box Contents
EP90-2dT 1 of 1 2 21 Nov 06 dT Box
EP90-8T 1 of 1 4 05 Feb 07 dT Box Contents
SD7528 1 of 1 1 22 Feb 07 Key to Dimensions dK and dN Boxes
SD7529 1 of 1 1 22 Feb 07 dK and dN Boxes Contents
EP90-5 1 of 1 4 05 Feb 07 Earthing and Other Details
SD7485 1 of 1 2 15 Mar 07 Ex d Box Sealing for Dust Certification
EP90-10 1 of 1 3 27 Feb 07 Linear Feedthrough C9L
EP90-4dA 1 to 9 5 20 Feb 07 d Series Boxes Data Sheets
EP90-6 1 of 1 6 20 Feb 07 Permitted Contents for MIU/d
SD7526 1 of 1 1 20 Feb 07 MIU/d Certification Label ATEX/IECEx
Issue 4
Drawing No. Sheets Rev. Date (Sira stamp) Title
SD7526 1 of 1 2 05 Oct 12 MIU/d Certification Label
Issue 5
Drawing Sheets Rev. Date (Sira stamp) Title
EP90-4dA 1 to 9 6 10 Apr 15 d-Series Boxes Data Sheets
SD7526 1 to 2 3 10 Apr 15 MIU/d Certification Label ATEX / IECEx
Issue 6
Drawing Sheets Rev. Date (Sira stamp) Title
EP90-4dA 1 to 9 7 30 Jul 2015 d-Series Boxes Data Sheets
SD7526 1 to 2 4 30 Jul 2015 MIU/d Certification Label ATEX/IECEx
This certificate and its schedules may only be Sira Certification Service
reproduced in its entirety and without change.
Unit 6, Hawarden Industrial Park,
Hawarden, CH5 3US, United Kingdom
Page 1 of 1 Tel: +44 (0) 1244 670 900
Form 9400 Issue 1 Fax: +44 (0) 1244 539 301
Email: ukinfo@csagroup.org
Web: www.csagroupuk.org
Certificado de Conformidade Certificado de Conformidade
Certificate of Compliance ♦ Certificado de Conformidad Certificate of Compliance ♦ Certificado de Conformidad
Certificado N.º: TÜV 12.1464 Revisão: 04 Válido até: 13/07/2021 Certificado N.º: TÜV 12.1464 Revisão: 04 Válido até: 13/07/2021
Certificate No. ♦ Certificado N.º: Review ♦ Revisión: Valid until ♦ Válido hasta: Certificate No. ♦ Certificado N.º: Review ♦ Revisión: Valid until ♦ Válido hasta:
Fabricante: EXPO TECHNOLOGIES LTD. A unidade de interface MiniPurge modelo MIU/d é formada por um invólucro “à prova de explosão” e por diversos
Manufacturer ♦ Fabricante: Unit 2, The Summit componentes/equipamentos que podem ser instalados internamente. Os invólucros utilizados são dos modelos dA, dX,
Hanworth Road, Sunbury on dT, dK ou dN, e possuem o mesmo formato básico, diferindo apenas no tamanho e nos componentes instalados.
Thames. TW16 5DB – UK Os invólucros são de perfil quadrado e possuem uma tampa circular, que forma uma junta roscada entre a tampa e o
invólucro, travada com a utilização de um parafuso. A instalação dos componentes é realizada com o auxílio de dois
Fornecedor / Representante Legal: Não aplicável. ou mais furos não-passantes na parede inferior do invólucro ou com a utilização de blocos de montagem.
Supplier / Legal Representative ♦ Proveedor / Opcionalmente, o invólucro pode ser fornecido com dois ou mais olhais de fixação.
Representante Legal:
O invólucro possui terminais de aterramento (M6 ou maior) na superfície externa do invólucro ou nos blocos de
montagem. Esses terminais possuem porcas, arruelas e pinos anti-rotação. Alternativamente ou adicionalmente,
Normas Técnicas / Regulamento: ABNT NBR IEC 60079-0:2013; podem ser fornecidos terminais de aterramento externos nos olhais de fixação. Opcionalmente, o invólucro pode ser
Standards / Regulation ♦ Normas / Reglamento: ABNT NBR IEC 60079-1:2009; fornecido com furos não-passantes entre os ressaltos anti-rotação dos terminais de aterramento. O aterramento
ABNT NBR IEC 60079-31:2014: interno é realizado através de um furo não-passante na face inferior interna do invólucro ou com a utilização de
Portaria INMETRO n° 179 de 18/05/2010.
conectores de aterramento montados em trilho nessa mesma face.
O invólucro pode ser fabricado em alumínio isento de cobre, ferro fundido (cinzento ou nodular), bronze fosforoso,
Esquema de Certificação: Modelo com Avaliação do Sistema de Gestão da Qualidade do latão vermelho (gunmetal) ou aço inoxidável e pode ser fornecido com um anel de vedação ‘o’ ring para proporcionar
Certification Scheme ♦ Esquema de Fabricante e Ensaios no Produto, conforme cláusula 6.1 do
Certificación: um grau de proteção adequado.
Regulamento de Avaliação da Conformidade, anexo à Portaria nº 179
O invólucro é fornecido com entradas roscadas nas paredes laterais e/ou na face traseira. A quantidade de entradas e
do INMETRO, publicada em 18 de maio de 2010.
a distância entre elas estão limitadas aos valores apresentados no documento nº EP90-4dA. As roscas permitidas são:
3/8” x 16 UNC, M20 x 1,5, M25 x 1,5, M32 x 1,5, M40 x 1,5 e M50 x 1,5.
Laboratório, N.º do Relatório de Ensaios e Sira Test & Certification. Para possibilitar o controle dos equipamentos internos, o invólucro pode ser fornecido com dispositivos de passagem
Data: Relatório de ensaios: GB/SIR/ExTR07.0032/00 de Março/2007.
Laboratory, Test Report No. and Date ♦
(feed-through) do modelo C9L. Este dispositivo é formado por uma bucha roscada e por um eixo interno, preso com
Relatório de ensaios: GB/SIR/ExTR07.0008 – emissão 02 de
Laboratorio, N.º del Informe de Prueba y Fecha: anéis de fixação em ambas as extremidades. O dispositivo é fixado à parede do invólucro com uma contraporca e com
27/11/2012.
uma arruela de vedação opcional. Este dispositivo de passagem pode ser fornecido com um anel de vedação ‘o’ ring -
instalado em volta do eixo e fora da passagem de chama - para proporcionar um grau de proteção adequado.
Certificado N.º: TÜV 12.1464 Revisão: 04 Válido até: 13/07/2021 Certificado N.º: TÜV 12.1464 Revisão: 04 Válido até: 13/07/2021
Certificate No. ♦ Certificado N.º: Review ♦ Revisión: Valid until ♦ Válido hasta: Certificate No. ♦ Certificado N.º: Review ♦ Revisión: Valid until ♦ Válido hasta:
As análises e os ensaios realizados encontram-se no relatório técnico n° AEX-13100. 1. Este Certificado de Conformidade é válido para os produtos de modelo e tipo idêntico ao protótipo ensaiado.
Qualquer modificação de projeto ou utilização de componentes e materiais diferentes daqueles descritos na
Documentação descritiva do produto: documentação deste processo, sem autorização prévia da TÜV Rheinland, invalidará o certificado.
− Relatório de ensaios nº GB/SIR/ExTR07.0032/00 de Março/2007; 2. É de responsabilidade do fabricante assegurar que os produtos fabricados estejam de acordo com as
− Relatório de ensaios nº GB/SIR/ExTR07/0008 – Emissão 02 de 27/11/2012; especificações do protótipo ensaiado, através de inspeções visuais e dimensionais.
− Relatório de ensaios nº GB/SIR/ExTR12.0251/01
Documento Descrição Rev. Data 3. Os produtos devem ostentar, na sua superfície externa e em local visível, a Marca de Conformidade e as
EP90-3dA Ex d Boxes Dimensions Key 6 21/11/2006 características técnicas da mesma de acordo com as especificações da ABNT NBR IEC 60079-0 /
EP90-2dA dA Box 3 21/11/2006 ABNT NBR IEC 60079-1 e Regulamento de Avaliação da Conformidade, anexo à Portaria nº 179 do INMETRO,
EP90-8A dA Box Contents 4 05/02/2007 publicada em 18 de Maio de 2010. Esta marcação deve ser legível e durável, levando-se em conta possível
EP90-2dX dX Box 2 21/11/2006 corrosão química.
EP90-8X dX Box Contents 4 05/02/2007
EP90-2dT dT Box 2 21/11/2006 4. Os produtos devem ostentar, em lugar visível e de forma indelével, as seguintes advertências:
EP90-8T dT Box Contents 4 05/02/2007
“ATENÇÃO – NÃO ABRA QUANDO ENERGIZADO”
SD7528 Key to Dimensions of dK & dN Boxes 1 22/02/2007
SD7529 dK & dN Boxes Contents 1 22/02/2007
“ATENÇÃO – A TEMPERATURA DOS CABOS PODE ULTRAPASSAR 70 ºC – UTILIZE CABOS
EP90-5 Earthing and Other Details 4 05/02/2007
ADEQUADOS”
SD7485 Ex d Box Sealing for Dust Certification 2 15/03/2007
EP90-10 Linear Feedthrough C9L 3 27/02/2007 5. Os bujões para fechar as aberturas não utilizadas e os dispositivos de entrada de cabos (prensa-cabos,
EP90-4dA d-Series Boxes Data Sheets (9 folhas) 5 20/02/2007 unidade seladora, etc.) devem ser certificados como à prova de explosão, adequados para as condições de
EP90-6 Permitted Contents for MIU/d 6 20/02/2007 uso e corretamente instalados.
SD7526 MIU/d Certification Label ATEX/IECEx 3 02/07/2015
SD7650 MIU/d TUV Certification Label 4 07/09/2015 6. As atividades de instalação, inspeção, manutenção, reparo, revisão e recuperação dos produtos são de
SD7651 MIU/d Portuguese Manual Extracts 4 13/07/2015 responsabilidade do usuário e devem ser executadas de acordo com os requisitos das normas técnicas
vigentes e com as recomendações do fabricante.
Marcação:
Modelos dK e dN:
Ex db IIB+H2 T5/T6 Gb
Ex tb IIIC T80 ºC /T95ºC Db
IP66
-20 ºC ≤ Ta ≤ +40 ºC (T6 /T80 ºC) Digitally signed by TUV RHEINLAND DO BRASIL LTDA:
01950467000165
-20 ºC ≤ Ta ≤ +55 ºC (T5 /T95 ºC) DN: c=BR, o=ICP-Brasil, st=SP, l=Santana de Parnaiba,
ou=Array, cn=TUV RHEINLAND DO BRASIL LTDA:
01950467000165
TÜV 12.1464 – Revisão 04 – 13/07/2018 – Página 3 de 4 TÜV 12.1464 – Revisão 04 – 13/07/2018 – Página 4 de 4
Reason: Digital Signature
Endereço Escritório: Rua Libero Badaró, 293, – 9º Andar, Conjunto B, Centro, São Paulo - SP CEP: 01009-000 / Location: Santana de Parnaiba/SP/BR Endereço Escritório: Rua Libero Badaró, 293, – 9º Andar, Conjunto B, Centro, São Paulo - SP CEP: 01009-000 /
Endereço Sede: Av. Netuno, 32 – 2º Andar, Sala 04, Alphaville, Santana de Parnaíba - SP, CEP: 06541-015 Date: 30.10.2018 18:33:25 +0000 Endereço Sede: Av. Netuno, 32 – 2º Andar, Sala 04, Alphaville, Santana de Parnaíba - SP, CEP: 06541-015
CNPJ: 01.950.467/0001-65 – Tel.: 55 11 3514.5700 – www.tuv.com/br – 700-CE-40-00 CNPJ: 01.950.467/0001-65 – Tel.: 55 11 3514.5700 – www.tuv.com/br – 700-CE-40-00
29/01/2018 RFPW7.E190061 - Purging and Pressurizing Controls and Accessories for Use in Hazardous Locations Certified for Canada 29/01/2018 RFPW.E190061 - Purging and Pressurizing Controls and Accessories for Use in Hazardous Locations
RFPW7.E190061 RFPW.E190061
Purging and Pressurizing Controls and Accessories for Use in Hazardous Purging and Pressurizing Controls and Accessories for Use in Hazardous
Locations Certified for Canada Locations
Purging and Pressurizing Controls and Accessories for Use in Hazardous Purging and Pressurizing Controls and Accessories for Use in Hazardous
Locations Certified for Canada Locations
See General Information for Purging and Pressurizing Controls and Accessories for Use in Hazardous Locations Certified for Canada See General Information for Purging and Pressurizing Controls and Accessories for Use in Hazardous Locations
Purge control units, Type X, for use in Class I, Groups A, B, C and D hazardous locations, Model** 1, 2, 3, 4, 5, 6 or 7 followed by X, followed Purge control units, Type X, for use in Class I, Groups A, B, C and D hazardous locations, Model** 1, 2, 3, 4, 5, 6 or 7 followed by X, followed
by CF, CFHP or LC, followed by BP, CS, SS or PM may be followed by one or more of the following: ET, IS, PO, AO, DS, DT, SS and MO. by CF, CFHP or LC, followed by BP, CS, SS or PM, may be followed by one or more of the following: ET, IS, PO, AO, DS, DT, SS and MO.
For the 'IS' option: intrinsically safe when installed in accordance with Control Drawing number EP80-2-11. For the 'IS' option: intrinsically safe when installed in accordance with Control Drawing number EP80-2-11.
Type Y for use in hazardous (classified) locations, Model** 1, 2, 3, 4, 5, 6 or 7 followed by Y, followed by CF, CFHP or LC, followed by BP, CS, Type Y for use in hazardous (classified) locations, Model** 1, 2, 3, 4, 5, 6 or 7 followed by Y, followed by CF, CFHP or LC, followed by BP, CS,
NM, PM, SS, may be followed by AO, DS, DT, IS, MO, NO, PO, SS. NM, PM, SS, may be followed by AO, DS, DT, IS, MO, NO, PO, SS.
Type Z for use in hazardous (classified) locations, Models** 1, 2, 3, 4, 5, 6 followed by Z, followed by CF, CFHP or LC, followed by BP, CS, PM, Type Z for use in hazardous (classified) locations, Models** 1, 2, 3, 4, 5, 6 followed by Z, followed by CF, CFHP or LC, followed by BP, CS, PM,
SS, may be followed by AO, DS, DT, IS, MO, NO, PO, SS. SS, may be followed by AO, DS, DT, IS, MO, NO, PO, SS.
Purge control accessory - Vent unit for use in hazardous (classified) locations, Model RLV followed by 25, 36, 52, 75, 104, 125, 150, or 200, Purge control accessory - Vent unit for use in hazardous (classified) locations, Model RLV followed by 25, 36, 52, 75, 104, 125, 150, or 200,
followed by CS or SS, may be followed by FS. followed by CS or SS, may be followed by FS.
** - Internal series identifier, precedes model number, which may contain one or more characters. ** - Internal series identifier, precedes model number, which may contain one or more characters.
Questions? Print this page Terms of Use Page Top Questions? Print this page Terms of Use Page Top
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product. Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non- Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory
with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in
the following format: "© 2018 UL LLC". the following format: "© 2018 UL LLC".
RFPW.E190061
Purging and Pressurizing Controls and Accessories for Use in Hazardous
Locations
Page Bottom
See General Information for Purging and Pressurizing Controls and Accessories for Use in Hazardous Locations
Purge control units, Type X, for use in Class I, Groups A, B, C and D hazardous locations, Model** 1, 2, 3, 4, 5, 6 or 7 followed by X, followed
by CF, CFHP or LC, followed by BP, CS, SS or PM, may be followed by one or more of the following: ET, IS, PO, AO, DS, DT, SS and MO.
For the 'IS' option: intrinsically safe when installed in accordance with Control Drawing number EP80-2-11.
Type Y for use in hazardous (classified) locations, Model** 1, 2, 3, 4, 5, 6 or 7 followed by Y, followed by CF, CFHP or LC, followed by BP, CS,
NM, PM, SS, may be followed by AO, DS, DT, IS, MO, NO, PO, SS.
Type Z for use in hazardous (classified) locations, Models** 1, 2, 3, 4, 5, 6 followed by Z, followed by CF, CFHP or LC, followed by BP, CS, PM,
SS, may be followed by AO, DS, DT, IS, MO, NO, PO, SS.
Purge control accessory - Vent unit for use in hazardous (classified) locations, Model RLV followed by 25, 36, 52, 75, 104, 125, 150, or 200,
followed by CS or SS, may be followed by FS.
** - Internal series identifier, precedes model number, which may contain one or more characters.
© 2018 UL LLC
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory
with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in
the following format: "© 2018 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=RFPW.E190061&ccnshorttitle=Purging+and+Pressurizing+… 1/1
NOIV.E203605 - Auxiliary Devices for Use in Hazardous Locations Page 1 of 1
NOIV.E203605
See General Information for Auxiliary Devices for Use in Hazardous Locations
Open type push button switches, Model XMPB followed by L or S, followed by 1, 2, 3 or 4, may
be followed by -N4 or -N4X.
Open type pilot lights , Cat. No. XMPL followed by ES, S or L followed by the letters A, B, G, R
or W *and followed by the numbers 12, 24 or 120.
Open type operator assemblies, Cat. No. XP followed by B, DB, IB, JMH, K2L, K2R, K2S, K3C,
K3L, K3R, K3S, MH, PM, PP, PTT, 2L, 2R, 2S, 3C, 3L, 3R, or 3S, may be followed by L or S, may
be followed by additional suffixes, may be followed by -N4.
This page and all contents are Copyright © 2005 by Underwriters Laboratories Inc.®
The appearance of a company's name or product in this database does not in itself assure that products so identified have
been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be
Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following
conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted
material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2005
Underwriters Laboratories Inc.®"
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage2.html?name=N
... 29/06/05
ML550 | v1 Page 60
FTRX.E181300 - Enclosure Accessories for Use in Hazardous Locations http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showp... NOIV.E203605 - Auxiliary Devices for Use in Hazardous Locations http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho...
NOIV.E203605
FTRX.E181300
Auxiliary Devices for Use in Hazardous Locations
Enclosure Accessories for Use in Hazardous Locations
Page Bottom
Page Bottom
See General Information for Enclosure Accessories for Use in Hazardous Locations
AKRON ELECTRIC INC E203605
1025 EAGON ST
AKRON ELECTRIC INC E181300 BARBERTON, OH 44203 USA
1025 EAGON ST
BARBERTON, OH 44203 USA
Class I, Groups B, C and D; Class II, Groups E, F and G.
Open type push button switches, Model XMPB followed by L or S, followed by 1, 2, 3 or 4, may be followed by -N4 or -N4X.
Class I, Groups B, C and D; Class II Groups E, F and G; Class III. Model XPL followed by LB or SB, followed by numbers, may be followed by N4.
Close-up plug, Cat. No. ZMPBP. Open type pilot lights , Cat. No. XMPL followed by ES, S or L followed by the letters A, B, G, R or W *and followed by the numbers 12, 24 or
120.
Pushbutton and selector assemblies, Cat. No. XP followed by B, BM, DB, JM, K2L, K2R, K2S, K3C, K3L, K3R, K3S, PP , T, 2L, 2R, 2S, 3C, 3L,
3R or 3S, may be followed by L or S, may be followed by additional suffixes, may be followed by -N4, -N4X. Class I, Groups B, C and D; Class II, Groups E, F and G; Class III.
Pushbutton assemblies, Cat. Nos. XRBL, XRBS. Open type operator assemblies, Cat. No. XP followed by B, DB, IB, JMH, K2L, K2R, K2S, K3C, K3L, K3R, K3S, MH, PM, PP, PTT, 2L, 2R, 2S,
3C, 3L, 3R, or 3S, may be followed by L or S, may be followed by additional suffixes, may be followed by -N4.
Reset operator, XMR followed by S or L, followed by 1, 2, 3 or 4, may be followed by -N4 or -N4X.
Open type selector switches , Cat. No. XMS followed by L or S, followed by 1, 2, or 4, may be followed by 2 through 12.
Selector assembly , Cat. No. XMS, followed by L or S, followed by 1, 2, or 4, may be followed by 2 through 12.
Last Updated on 2006-10-02
The Classification Mark of Underwriters Laboratories Inc. is the only method provided by Underwriters Laboratories Inc. to identify products
produced under its Classification and Follow-Up Series. See General Information Card of above guide designation.
Questions? Notice of Disclaimer Page Top
Last Updated on 2006-06-06
Page 61
Copyright © 2007 Underwriters Laboratories Inc.®
Questions? Notice of Disclaimer Page Top The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
Copyright © 2007 Underwriters Laboratories Inc.® UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc."
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format:
Service. Always look for the Mark on the product. "Copyright © 2007 Underwriters Laboratories Inc.®"
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc."
must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format:
"Copyright © 2007 Underwriters Laboratories Inc.®"
ML550 | v1
1 of 1 15/06/2007 10:23 1 of 1 15/06/2007 10:22
With
EU Declaration of European
Conformity Directives
MiniPurge Interface Units (MIU/d) are certified under SIRA Certification Service, Hawarden Industrial
Park, Hawarden CH5 3US, England, under EC Type-Examination Certificate SIRA 02ATEX1129, in
compliance with:
EN 60079-0 : 2012 + A11:2013 EN 60079-1 : 2014 EN 60079-31: 2014
MiniPurge Interface Units (MIU/d) - Type: /dA, /dX, /dT, /dK and /dN are rated and shall be marked as
follows: II 2 GD
MiniPurge Interface Units MIU/d systems are manufactured under Production Quality Assurance
Notification SIRA 99 ATEX M043, issued by SIRA Certification Service, Notified Body No 0518.
Issue 7
www.expoworldwide.com