A C B A C B: First Floor Lighting Layout Second Floor
A C B A C B: First Floor Lighting Layout Second Floor
A C B A C B: First Floor Lighting Layout Second Floor
WIRE
SINGLE PHASE, 230 V (LINE TO
GROUND SYSTEM)
3 3
h g h g
TOILET S-g,h TOILET S-g,h
40 AT
d e e e
OFFICE SPACE
COMMERCIAL SPACE
LO 1 15AT 15AT 2 LO
S-d,e,f
CO 3 20AT 20AT 4 SPARE
2 d
S-d,e,f
e
2 d d
S-a,b,c
c c f c c f
OFFICE SPACE
COMMERCIAL SPACE
9
8
7
SINGLE LINE DIAGRAM - GROUND FLOOR
b b 6 LP-GF b b LP-SF
5 2 2
4
3
ELECTRICAL SPECIFICATIONS
S-a,b,c S-a,b,c
2
1 a a
1
up 1 a a
1. ALL ELECTRICAL WORKS SHALL CONFORM TO THE NEW RULES AND REGULATIONS OF THE
NATIONAL ELECTRICAL CODE OF THE PHILIPPINES, CITY ORDINANCES AND ELECTRIC UTILITY
C A N O P Y
TOTAL 1910 8.304 8. SERVICE ENTRANCE CONDUCTOR SHALL BE INSTALLED IN FREE OR WITH A TEMPERATURE
lW = (l T x Demand Factor of 80%) + 25% LARGEST MOTOR LOAD
RATING OF 75 DEGREE CELCIUS
lW = (8.304 x 0.8) + (0.25 x 5.478) = 8.0127 Amps USE 2 - 14mm² THWN CU WIRE IN 25mmØ IMC
9. ALL WIRINGS SHALL BE CAREFULLY INSPECTED AND APPROVED BY A COMPETENT
l CB = (l W + 250% LARGEST MOTOR LOAD ELECTRICAL INSPECTOR BEFORE THE CURRENT IS TURNED ON, AND AN APPROVAL BY THE
l CB = 6.6432 + (2.5 x 5.478) = 20.3382 Amps USE 40 AT MAIN, 230 VOLTS, 2P, 60 HZ FIRE DEPARTMENT IS NEEDED.
PREPARED BY: PRC REG. NO.: PROJECT TITLE AND LOCATION: APPROVED : SHEET CONTENTS : SHEET NO.
PTR NO. :
PROPOSED TWO STOREY WITH ROOF DECK FIRST FLOOR LIGHTING LAYOUT
DATE ISSUED :
PLACE ISSUED : SECOND FLOOR LIGHTING LAYOUT
COMMERCIAL BUILDING LUCILLE L. LINGATONG SINGLE LINE DIAGRAM - GF E-1
NIJAGA STREET, BRGY. POBLACION, CALBAYOG CITY WESTERN SAMAR BUILDING OWNER SCHEDULE OF LOADS - GF 10 11
Professional Electrical Engineer TIN : ELECTRICAL SPECIFICATIONS