OI - Controller - JAB S1Controller Short Guide - v3

This document provides a summary of the controller software specification for compressor and machine controls. It outlines the user interface functions including start, stop, reset, navigation, and display symbols. It describes the menu mode navigation and structure. The menu structure includes pages for operational data, error logs, configuration, and diagnostic information. It lists the configurable settings and parameters that can be adjusted.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
229 views6 pages

OI - Controller - JAB S1Controller Short Guide - v3

This document provides a summary of the controller software specification for compressor and machine controls. It outlines the user interface functions including start, stop, reset, navigation, and display symbols. It describes the menu mode navigation and structure. The menu structure includes pages for operational data, error logs, configuration, and diagnostic information. It lists the configurable settings and parameters that can be adjusted.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Author: JAB/Lew

Date: 28.12.2011

Compressor and Machine Controls


CONTROLLER SOFTWARE SPECIFICATION

ONLY FOR PRELIMINARY INFORMATION


20210614/RHe

J.A.BECKER
Software Specification
S1JABBS.E13

SHORT GUIDE
Version 3.0

S1 CONTROLLER

page 1 of 6
Author: JAB/Lew
Date: 28.12.2011

Compressor and Machine Controls


CONTROLLER SOFTWARE SPECIFICATION

User Interface

START: Enter STARTED condition


STOP: Exit STARTED condition
RESET: Reset and clear fault conditions
ENTER: Confirm selection or value adjustments
MINUS/DOWN: Scroll down through menu, menu item options or decrement value
PLUS/UP: Scroll up through menu, menu item options or increment value
ESCAPE (C): Step back one menu navigation level

Display

°F
°C
bar
psi
kPa
p

Operational Display Symbols:

Motor Running

Loaded

Amount of time, timer


p Filter, differential pressure (optional function)

Pressure set point indication (upper and lower set point indicators displayed independently)

Condensate drain active (optional function)

Power failure auto restart enabled (optional function)

page 2 of 6
Author: JAB/Lew
Date: 28.12.2011

Compressor and Machine Controls


CONTROLLER SOFTWARE SPECIFICATION

Remote load or remote pressure regulation active

Remote start/stop

Normal Operational: selected item locked as temporary default display


Menu Mode: page item locked (adjustment inhibited)

Fault Display Symbols:

General fault Lubrication, oil, oil level

Emergency stop Dewpoint

Excess pressure Motor

Power failure Service due, maintenance

Above set temperature limit p Filter differential, filter service

Menu Mode Navigation:

Page 0 Page 1

Page 2
Item 1 Value
Item 2 Value Page 3 Item 1 Value
Item 3 Value Item 2 Value
Page 4
Item 4 Value Item 3 Value
Item 5 Value Page 5 Item 4 Value
Item 6 Value Item 5 Value

Page 0 Page 1

Page 2
Item 1 Value
Item 2 Value Page 3 Item 1 Value
Item 3 Value Item 2 Value
Page 4
Item 4 Value Item 3 Value
Item 5 Value Page 5 Item 4 Value
Item 6 Value Item 5 Value

page 3 of 6
Author: JAB/Lew
Date: 28.12.2011

Compressor and Machine Controls


CONTROLLER SOFTWARE SPECIFICATION

Menu Structure
D1 digital input 1
D2 digital input 2
D3 digital input 3
P00: PI inlet pressure * P06: D4 digital input 4
User Td delivery air temperature ** Diagnostic D5 digital input 5
H1 total running hours D6 digital input 6
H2 service hours D7 digital input 7
C> compressor status D8 digital input 8
R1 relay output 1
R2 relay output 2
R3 relay output 3
* only shown if internal pressure function enabled R4 relay output 4
** only shown if temperature sensor used R5 relay output 5 *
R6 relay output 6 *
A1 analogue input 1
A2 analogue input 2
Access Code >0009 A3 analogue input 3
Ao analogue output 1 *

* S1-20 only
User level

du unload pressure
dL load pressure
Iu Inlet pressure high star/delta time
IL Inlet pressure low Ls load source
Ct Control type/mode SS start req. source setting
P01: Bt blow down time Ad network address
P> press. units bar/psi/kPa IS indication field
Operation o o
T> temp. units C/ F P07: At auto restart delay time
do drain open time *** Configuration Ao analogue output select
dt drain interval time *** On Oil pressure on time
di drain initial opening *** Of Oil pressure off time
RL Run limit time
Rm Max run time
*** only shown if drain function is enabled Ot Intermediate stop time
Dt Dryer time
Ts Temperature sensor used
01 logged error # 1 Ip Inlet pressure used
P02: to Ed error 0135 delay time
Error Log 15 logged error # 15 Vd valve time
Vt valve type
Ar automatic regulation

Access Code
Access >0100
level 1 //only for service staff//

P03: Td air temp. high level


Shutdown Pd delivery press. high level

do delivery press. offset


P08: dr delivery press. range
Calibration Io internal press. offset
SD service due timer Ir internal press. range
P04:
Alarm Td delivery temp. high level
Pd delivery press. high level

Access Code >XXXX //only for service staff//


Access level 2

Rt reset to factory defaults


P05: Td delivery air temp. low level dr delivery P.senor range
P09: Ir internal P.senor range
Start/Run Inhibits Configuration Er error log reset
Access level 2 H1 running hours edit
Td temp sensor type

page 4 of 6
Author: JAB/Lew
Date: 28.12.2011

Compressor and Machine Controls


CONTROLLER SOFTWARE SPECIFICATION

Led Indicators
STATUS: Green, adjacent to Start and Stop buttons
FAULT: Red, adjacent to Stop and Reset buttons

Indicator States:

ON: Illuminated continuously.


FF: Fast Flash: on/off four times per second.
SF: Slow Flash: on/off once per second.
IF: Intermittent Flash: on/off every four seconds.
OFF: Extinguished continuously.

Machine State Number Machine State Status Fault

1 Shutdown Error OFF FF


2 Startup Init OFF OFF **
3 Start Inhibit Check OFF OFF **
Start inhibit condition SF
4 Ready to Start OFF OFF **
5 Blowdown if (load_request) FF OFF **
else IF
6 Standby IF OFF **
7 Start Motor in Star/Delta if (load_request) FF OFF **
else IF
8 Load ON OFF **

** SF for Alarm condition

page 5 of 6
Author: JAB/Lew
Date: 28.12.2011

Compressor and Machine Controls


CONTROLLER SOFTWARE SPECIFICATION

Fault Messages
Er:0010 E emergency stop
Er:0020 E oil pressure fault
Er:0030 E phase error
Er:0050 E stage pressure fault
Er:0060 E stage temperature fault
Er:0070 E universal fault
Er:0080 E motor fault (fault relay contact, overload device contact or PTC thermistor)

Er:0115 E delivery pressure sensor fault


Er:0119 E delivery pressure high fault
Er:0125 E delivery temperature sensor fault
Er:0129 E delivery temperature high fault
Er:0133 E inlet pressure low fault
Er:0135 E inlet pressure sensor fault
Er:0139 E inlet pressure high fault

Er:0821 E low resistance, short circuit or short circuit to earth condition exists on an analogue input or
digital input (incorrect connection, cable fault or sensor fault)
Er:0836 E PLL unlocked fault (due to extreme EM interference).
Er:0846 E Delivery pressure sensor range is set too low for default pressure settings to be applied.
Er:0856 E Inlet pressure sensor range is set too low for default pressure settings to be applied.

Er:2118 A delivery pressure high alarm


Er:2128 A delivery temperature high alarm
Er:2814 A Compressor run time exceeded
Er:2816 A power failure occurred while compressor was in the Started state

Er:4804 A service hours time expired, service due (reset service hours countdown timer)

Er:3123 R delivery temperature Td below the set low temperature run inhibit level, controller will allow
motor start when temperature increases above the set level