Connectors - Safety Requirements and Tests: Test Report IEC 61984
Connectors - Safety Requirements and Tests: Test Report IEC 61984
Connectors - Safety Requirements and Tests: Test Report IEC 61984
0
TRF Template 2017-05-17
TEST REPORT
IEC 61984
Connectors – Safety requirements and tests
Test specification:
Standard ......................................... : IEC 61984:2008
Test procedure .......................... : CB Scheme
Non-standard test method ............ : N/A
Test Report Form No. .................... : IEC61984C
Test Report Form(s) Originator .... : VDE Prüf - und Zertifizierungsinstitut GmbH
Master TRF ..................................... : Dated 2017-06
Copyright © 2017 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment
and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
Testreport-250148-TL6-1.DOCX
VDE File No. 257500-1431-0045/250148
Page 2 of 23 Report No.: 250148-TL6-1
Manufacturer .................................... : Weidmüller Interface GmbH & Co. KG; Klingenbergstraße 16;
32758 Detmold; Germany
Model/Type reference ...................... : BCZ 3.81 Buchsenteil / female part; SC 3.81 Stiftteil / male part
Ratings .............................................. : 160 V / 17,5 A
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
Complete test according to IEC 61984 VDE Testing and Certification Institute
Merianstrasse 28, 63069 Offenbach, Germany
BCZ 3.81
SC 3.81
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .. : Weidmüller Interface (Suzhou) Co., Ltd., OEM-Business; 81
Xiangyang Road Suzhou New District; 215011 SUZHOU CITY;
Jiangsu; China / Reference 30017348
6.2.3 Position for the contacts and protective earthing The definite marking of the P
contacts clearly indicated. contacts has to be guaranteed
Marking of protective earthing contacts applies by overprint or the build-in
conditions.
symbol or “PE”. This requirement is not
necessary for non rewirable connectors.
A2 DURABILITY OF MARKING
A5 INTERLOCK
7.3.4 The specimens are engaged by hand over their full N/A
engagement distance. All other contacts are wired
in series. The interlock contacts “make last and
break first”, before any other contact does.
A6 TERMINATIONS
6.6.1 g) Test acc. to: IEC 60999-1 or IEC 60999-2 or IEC N/A
60352-7 Screwless-type clamping units
6.6.1 h) Test acc. to: IEC 60999-1 or IEC 60999-2 Female part P
Screw-type clamping units
Test load shall be three times the specified insertion force of one contact: —
insertion force (mating) of one contact or the 3,4 N
specified insertion force of one contact plus 50 N, Test load 20 N
whichever is less. Minimum test load 20 N.
Covers mounted / contacts not connected See appended table A8.1 N/A
A9 MECHANICAL STRENGTH IMPACT (Only free Connectors and CBC): IEC 60512
Test 7b
Rest .................................................................... : 30 s
6.16 The upper limiting temperature specified for the See appended table C1 P
specimen is not exceeded
Supplementary information:
Supplementary information:
Supplementary information:
Supplementary information: