Dimensions: U-P3-RX
Dimensions: U-P3-RX
Dimensions
30
M20 x 1.5
11
80
65
ø5.3
16
65
80
Electrical connection
PE
Model Number RS 485 A
B
+
U-P3-RX PE
- 24 V DC
RXD
Base with serial interfaces RS 232 and RS 232 GND
RS 485 TXD
Cable gland
Features
• Protection degree IP67
• With serial interfaces RS 232 and
RS 485 Technical data
Electrical specifications
Function Rated operational voltage Ue 20 ... 30 V DC , ripple 10 %SS , PELV
Power consumption P0 max. 4 W with read/write head IPT*-FP
The base is used in combination with an Electrical isolation
upper part, the IPT*-FP read/write station. Operating voltage/interface functional insulation acc. to DIN EN 50178, rated insulation volt-
Either an RS 232- or an RS 485-interface is age 50 Veff
available. Interface
The read/write station is connected to a Physical RS 232/RS 485
higher-order control system via the serial Protocol ASCII
interface and receives the commands for Transfer rate 1200; 2400; 4800; 9600; 19200; 38400
writing and/or reading code or data carriers Cable length ≤ 15 m at RS 232
via this interface. ≤ 1200 m at RS 485
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Software Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Communication with the identification system
Protection degree IP67 according to EN 60529 with IPT*-FP
is very easy with the demo program
Connection screw terminals
IDENT 2005. It shows the system options
Interface cable 3 conductor, acc. to RS 232 or 2 acc. to RS 485
and simplifies commissioning.
110697_eng.xml
IPT-FP
Read/write station
IPT1-FP
Read/write station
KHD2-MTI-AB4
Release date: 2011-07-19 12:11
Accessories
RFIDControl
Software for RFID identification systems