3920b Analog and Digital Radio Test Platform Data Sheets en
3920b Analog and Digital Radio Test Platform Data Sheets en
Data Sheet
VIAVI
3920B
Analog and Digital Radio Test Platform
General Specifications
RF Signal Generator <1% (1 kHz rate, 30 to 70% AM, 6 kHz deviation
THD
FM, 300 Hz to 3 kHz BW, Sine)
Frequency
Internal FM
10 MHz to 1.05 GHz (Standard) (Usable from 100
kHz) Deviation
Range ±0.001 to ±150 kHz, OFF
10 MHz to 2.7 GHz (392XOPT058) (Usable from 100 Range
kHz)
3% (From ±1 kHz to ±100 kHz deviation, 20 Hz to
Accuracy
Resolution 1 Hz 15 kHz rate)
Accuracy Frequency standard ±1 count Resolution 1 Hz
Output Level Deviation Rate 20 Hz to 20 kHz
T/R Port: -130.0 to -30 dBm (-30 dBm max for CW Internal AM
or FM; -35 dBm max for AM modulations; -40 dBm
Modulation
max for complex modulation) 0 to 100%
Range Range
GEN Port: -130.0 dBm to +10.0 dBm (+10 dBm max
for CW or FM; +5 dBm max for AM modulations; 0 1% (Modulation from 10% to 90% 20 Hz to 15 kHz
Accuracy
dB max for complex modulation) rate)
Resolution 0.1 dB Resolution 0.1%
1.0 dB for levels >-110 dBm (Typical better than 0.6 Rate 20 Hz to 20 kHz
dB) Internal SSB
Accuracy
1.5 dB for levels <-110 dBm (Typical better than 1.0
dB) Modulation
Upper SideBand (USB) or Lower SideBand (LSB)
Selection
Spectral Purity
Modulation
Residual FM <5 Hz (300 Hz to 3 kHz bandwidth) 0 to 100%
Range
Residual AM <0.1% RMS (300 Hz to 3 kHz bandwidth) Resolution 0.1%
<-25 dBc (Typically -30 dBc, RF level set at +10 Rate 300 Hz to 20 kHz
Harmonics
dBm)
External AM / FM / SSB
<-55 dBc (all freq. except Crossovers)
<-35 dBc (at 2nd order crossover frequency) With 1 Vrms, AM / FM / SSB have same
(10 MHz to 1 GHz: Crossover = 1400 MHz - Gen characteristics as internal sources, ±10% of
Non- Audio Inputs indicated setting. (Audio 1 or Audio 2 input from 20
freq.)
Harmonics Hz to 15 kHz [300 Hz to 3 kHz SSB] unbalanced). 8
(1 GHz to 2.7 GHz: Crossover = 3400 MHz - Gen
freq.) Vrms maximum modulation input level.
(Tracking Gen: Crossover = 3410.7 MHz - Gen freq.) With 50 mVrms, AM / FM / SSB have same
<-110 dBc / Hz @ 10 kHz offset, RF <500 MHz Microphone characteristics as internal sources, ±10% of
Phase Noise <-106 dBc / Hz @ 10 kHz ofset, RF <1000 MHz Input indicated setting. (MIC Input from 100 Hz to 15 kHz
<-95 dBc / Hz @ 10 kHz offset, RF >1000 MHz [300 Hz to 3 kHz SSB]).
OFF, AM, FM, FM50µs, FM75µs, FM750µs, AM USB, Sample Rate <1.89 Msamples / sec
Selections
AM LSB, IQGEN Size <3.8 million samples
Waveforms Sine, Square, Triangle, Ramp, DCS, DTMF Source File created by IQCreator
RF Receiver RF Error Meter
RF Receiver 0 to ±2.5 MHz from receiver frequency (6 MHz IF
Range
BW)
Demod AM, FM, FM50µs, FM75µs, FM750µs, AM USB, AM
Selections LSB Resolution 1 Hz
10 MHz to 1.05 GHz (Standard) (Usable from 100 Accuracy Frequency standard ±1 count
Frequency kHz)
T/R Port: -10 to +50 dBm
Range 10 MHz to 2.7 GHz (392XOPT058) (Usable from 100 Level Range
ANT Port: -60 to +10 dBm
kHz)
Signal CW, FM, AM <70% modulation
<-100 dBm (10 dB SINAD, FM, 25 kHz, 1 kHz rate,
6 kHz FM Deviation, 300 Hz to 3.4 kHz AF Filter, Demodulation Measurements
Pre-amp OFF) RF Characteristics
Sensitivity
<-113 dBm (10 dB SINAD, FM, 25 kHz, 1 kHz rate,
6 kHz FM Deviation, 300 Hz to 3.4 kHz AF Filter, 10 MHz to 1.05 GHz (Standard) (Usable from 100
Pre-amp ON) Frequency kHz)
Range 10 MHz to 2.7 GHz (392XOPT058) (Usable from 100
Demod Output Level kHz)
Nominally 1 Vrms (for deviation ±1/4 of selected T/R Port: -10 to +50 dBm
FM Input RF Level
BW; 25 kHz BW same output level as 30 kHz BW) ANT Port: -80 to +10 dBm
AM Nominally 2 Vrms (100% AM) Demod Counter
RF Measurements 20 Hz to 20 kHz (1 to 100 kHz FM Deviation, IF BW
RF Power Meter (Broadband) set appropriately for the received modulation BW)
Range
20 Hz to 10 kHz (30 to 90% AM, IF BW set
10 MHz to 1.05 GHz (Standard) (Usable from 2
appropriately for the received modulation BW)
Frequency MHz)
Range 10 MHz to 2.7 GHz (392XOPT058) (Usable from 2 Resolution 0.1 Hz
MHz) Accuracy ±50 ppm (±10 ppm typical)
Level Range 100 mW to 125 W (Usable from 10 mW) Waveform Sine or Square
Resolution 4 digits for W or 0.1 dB FM Deviation Meter
Accuracy 10%, 1 digit Range 0 to 150 kHz
Signal CW, FM, C4FM, 4FSK Resolution 10 Hz
RF Power Meter (Inband) ±3% plus source residual, ±1 count (1 to 150 kHz FM
10 MHz to 1.05 GHz (Standard) (Usable from 100 Accuracy deviation, IF BW set appropriately for the received
Frequency kHz) modulation BW)
Range 10 MHz to 2.7 GHz (Freq Ext Opt) (Usable from 100 Filter
kHz) Characteristic 0.01 dB (15 kHz low pass audio filter) above 20 Hz
T/R Port: -60 to +51 dBm Response
Lowest reading is receiver BW dependent Meter Flatness 0 dB
(Narrower bandwidths can measure lower levels)
Level Range 20 Hz to 20 kHz (IF BW set appropriately for the
ANT Port: -100 to +10 dBm FM Rate
Lowest reading is receiver BW dependent received modulation BW)
(Narrower bandwidths can measure lower levels) AM Deviation Meter
Resolution 0.1 dB Range 0 to 100%
±1 dB (Input level above minimum for selected BW Resolution 0.1%
Accuracy
[display not yellow], typically better than 0.6 dB)
±3% + source residual, ±1 count (30 to 90% AM, IF
AM Filter BW 6.25, 8.33, 10, 12.5, 25, and 30 kHz Accuracy BW set appropriately for the received modulation
FM Filter BW 6.25, 10, 12.5, 25, 30, 100, and 300 kHz BW)
Signal CW, FM, AM, C4FM, 4FSK, OPSK, QAM 20 Hz to 15 kHz (IF BW set appropriately for the
AM Rate
received modulation BW)
RF Counter
Audio and Modulation Measurements
10 MHz to 1.05 GHz (Standard) (Usable from 100
kHz, Auto-tune) Audio Input
Range Characteristics AF Counter, AF Level Meter, SINAD Meter,
10 MHz to 2.7 GHz (392XOPT058) (Usable from 100
kHz, Auto-tune) for the Distortion Meter, Hum and Noise Meter, Signal-to-
following Noise Meter
Resolution 1 Hz meters
Accuracy Frequency standard ±1 count Audio 1 or Audio 2 (unbalanced, chassis reference)
Front Panel
Level Range for T/R Port: -10 to +50 dBm (Find level is selectable) Audio 1 and Audio 2 (balanced, 600 Ω differential
Audio Inputs
Auto-tune ANT Port: -60 to +10 dBm (Find level is selectable) input)
Signal CW, FM, AM <70% modulation Hi-Z (>10 kΩ) - Unbalanced input
Audio Input 600 Ω - Unbalanced Input (8 Vrms MAX input)*
Impedance 600 Ω - Balanced input (Audio 1 and 2)
(Audio 1 and 2) *Note - 600 Ω unbalanced will auto-switch to Hi-Z
@ 8 Vrms
300, 600, 1200, 2400, 4800, 9600, 19.2k, 38.4k, 57.6k, EMC EN 61329, Class 2
Baud Rates
115.2k >8,000 hour calculated MTBF (MIL-HDBK-217F,
Reliability
Stop Bits 1 or 2 notice 2)
Connector Type 25 position, female D-sub Internal 30 GByte hard disk available for user
Disk Storage
storage
Function Printer interface
USB P25 (Optional System)
Twin USB standard connection (rear panel) RF Signal Generator
Connector Type
Single USB standard connection (front panel)
Frequency
Function IEEE-488, 1-1997
Range 10 MHz to 1.05 GHz (Standard) (Usable from
Test Port 100 kHz)
Connector Type 15 position, female 3 tier D-sub 10 MHz to 2.7 GHz (392XOPT058) (Usable
from 100 kHz)
Programmable I/O and voltage output (optional
Function Resolution 1 Hz
interface)
Auxiliary IF Input Accuracy Frequency standard ±1 count
Function External digital receiver input (optional interface) Range T/R Port: -138.0 to -30.0 dBm for C4FM and
H-CPM modulations (-40.0 for all other
AC Power Requirements modulations)
Mains Supply GEN Port: -130.0 to +10.0 dBm for C4FM and
110 V to 220 VAC ±10% H-CPM modulations (+0.0 dBm for all other
Voltage
modulations)
83362 390XOPT114 TETRA Energy Economy Mode 83355 390XOPT059 Auto-Test II Environment for Analog
(Requires Opt110) Radio Systems
83360 390XOPT111 TETRA BS (Base Station Testing) 83387 390XOPT603 TIA / EIA-603 FM Land Mobile Test
Software (Requires Opt059)
83361 390XOPT112 TETRA DM (Direct Mode Testing)
138575 390XOPT624 Collins Aerospace 721S Blade Auto-
83363 390XOPT200 P25 Conventional Operation (with Test (Requires Opt059, 061)
DES OFB Type III)
TETRA Radios
83364 390XOPT201 P25 Trunking Operation VHF / UHF /
700 / 800 MHz (Requires Opt200) 85543 390XOPT115 Auto-Test II Environment for TETRA
Radio Systems
83369 390XOPT212 Explicit Mode Trunking (UHF / VHF
only) (Requires Opt201) 90676 390XOPT611 Motorola TETRA MS Auto-Test
Software - Includes Opt054 as standard (Requires
83370 390XOPT213 Unit to Unit Call (Requires Opt212)
Opt110, 115)
83371 390XOPT214 Adjacent Channel Broadcast Message
90943 390XOPT621 Motorola TETRA MTS (Requires
(Requires Opt201)
Opt115, 111)
83372 390XOPT215 Secondary Control Channel Broadcast
Message (Requires Opt201) P25 Radios
84412 390XOPT260 P25 Performance Test Triggers 83373 390XOPT218 Auto-Test II Environment for P25
(Requires Opt200 and Opt201) Radio Systems (Requires Opt200)
83365 390XOPT204 LSM Generate and Receive / Analysis 87371 390XOPT607 BK Technologies DPHX5102X Series
(Requires Opt200) Auto-Test and Alignment Software (Requires
Opt218, 061)
83366 390XOPT206 P25 Control Channel Logger Option
(Requires Opt200) 91956 390XOPT627 BK Technologies KNG Command
Series Auto-Test and Alignment Software;
82566 390XOPT230 Off Air Monitor Software for P25 Portables Only (Requires Opt218, 061)
Message Logging - Protocol Analysis Tool (Requires
Opt206) 139148 390XOPT636 BK Technologies KNG S-Series
(Portables only) Auto-Test and Alignment Software
83367 390XOPT207 SMARTNET / SmartZone Option
(Requires Opt218, 061)
(Requires Opt200)
62377 390XOPT209 KVL 3000 & 4000 Keyloader Option 87372 390XOPT606 EF Johnson ES Series Auto-Test and
(Requires Opt200) Alignment Software (Requires Opt218, 061)
90532 390XOPT220 Phase 2 Two-Slot Time Division 112997 390XOPT633 EF Johnson Viking Series Auto-Test
Multiple Access Physical Layer (Requires Opt200) and Alignment Software (Requires Opt218, 061)
67444 390XOPT240 P25 AES Encryption (Requires 90966 390XOPT616 L3Harris P25 Series Auto-Test and
Opt200) Alignment Software (Requires Opt218, 061)
83378 390XOPT250 Occupied Bandwidth for P25 91955 390XOPT625 L3Harris P25 ADVANCED Series Auto-
(Requires Opt200) Test and Alignment Software (Requires Opt616)
83383 390XOPT400 DMR (MOTOTRBO) ETSI 102-361 140637 390XOPT637 L3Harris XL Series Auto-Test and
Alignment Software (Requires Opt218, 061)
84413 390XOPT402 DMR XML Channel Logger Option
(Requires Opt400) 87370 390XOPT605 Icom P25 Auto-Test and Alignment
Software (Requires Opt218, 061)
84414 390XOPT420 dPMR - ETSI 102-658
90946 390XOPT608 Kenwood 5x10 Series Auto-Test and
90533 390XOPT422 dPMR Control Channel Logger Option
Alignment Software (Requires Opt218, 061)
(Requires Opt420)
91959 390XOPT630 Kenwood 5x20 Series Auto-Test and
84416 390XOPT440 NXDN
Alignment Software (Requires Opt218, 061)
104218 390XOPT442 NXDN XML Channel Logger (Requires
141437 390XOPT641 Kenwood Viking 5/6/7000 Series
Opt440)
Auto-Test and Alignment Software (Requires
84418 390XOPT460 ARIB T98 Opt218, 061)
140219 390XOPT462 ARIB T98 Channel Logger (Requires 83385 390XOPT600 Motorola ASTRO 25 XTS / XTL Series
Opt460) Auto-Test and Alignment Software (Requires
Opt218, 061)
140899 390XOPT645 Motorola APX “B” Series Auto-Test 90322 3920 6U Rack Mount Kit
and Alignment Software (Requires Opt604) 67442 Kit, 10 / 20 dB Pads, TNC
390XOPT646 390XOPT646 Motorola APX NEXT™ Series Auto- 67411 Scope Probe Kit
Test and Alignment Software (Requires 604) 10456 3920 Front / Rear Cover
91958 390XOPT629 Tait P25 Series Auto-Test ONLY 63928 DC to AC Converter, 12 VDC to 110-120 VAC
(Requires Opt218, 061)
9149 Antenna (BNC) (50 MHz)
DMR Radios 82556 Attenuator (6 dB / 150 Watts), 1.5 GHz
83384 390XOPT401 Auto-Test II Environment for DMR 82557 Attenuator (10 dB / 150 Watts), 1.5 GHz
Radio Systems (Requires Opt400) 58520 50 Ohm 250 Watts 5 GHz Termination
91705 390XOPT626 DMR Repeater Auto-Test Software 140309 3920 Return Loss Bridge Kit
(Requires Opt401, 061) 64009 3920 Microphone
91957 390XOPT628 Hytera DMR Series Auto-Test and 63351 RF Cable for AutoAlignment (COAX ASSY, RG223,
Alignment Software (Requires Opt401, 061) 36.0, BNC, M, ST / BNC, M, ST)
141994 390XOPT642 Hytera DMR Repeater Auto-Test 63927 Survey Technologies Inc (STI) Site Survey Package
(Requires Opt628) (Software & GPS Antenna)
Multi-Protocol Radios
Languages