WATER TANK PRESSURE

TANK

GENERAL NOTES: FROM EXISTING WATER SUPPLY


3000 3000 Republic of the Philippines
WP Department of Public Works
1. ALL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. Transportations and Communications
2. ALL INSTALLATION THEREIN SHALL BE DONE TO THE BEST PRACTICE OF THE PROFESSION SUPERVISED DURING CONSTRUCTION BY A LICENSED HB HB
OFFICE OF THE BUILDING OFFICIAL
HB HB
MASTER PLUMBER.
3. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATION. THE EMPLOYER'S REPRESENTATIVE SHALL BE NOTIFIED
IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN. HB
HB

4. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATIONS REQ'D FOR PROPER EXECUTION OF OTHER TRADE SHALL BE W/
PRIOR APPROVAL OF THE EMPLOYER'S REPRESENTATIVE.
HB
LAUNDRY AREA
5. IT IS NOT INTENDED THAT THE DRAWINGS SHALL SHOW EVERY PIPE, FITTING, VALVE AND APPLIANCE. ALL SUCH ITEMS WHETHER SPECIFICALLY HB District / City / Municipality
MENTIONED OR NOT, OR INDICATED ON THE DRAWINGS SHALL BE FURNISHED AND INSTALLED. IF NECESSARY, TO COMPLETE THE SYSTEM IN
ACCORDANCE WITH THE BEST PRACTICE OF THE PLUMBING TRADE AND TO THE SATISFACTION OF THE EMPLOYER'S REPRESENTATIVE.

4000
4000
HB

6. PIPING SHALL BE PROPERLY GRADED OR PITCHED TO ENSURE EASY DRAINAGE. THE MINIMUM SLOPES SHALL BE AS FOLLOWS: HB

a. SANITARY PIPES: FOR 80mm AND BELOW - 1:50


FOR 100mm AND LARGER - 1:100

7. EXACT LOCATION OF EXISTING UTILITIES ( WATERLINES, SEWER LINES, MANHOLES, AND STORM DRAINAGE LINES ) SHALL BE VERIFIED BY THE
CONTRACTOR AT JOBSITE.
LAND USE & ZONING
8. THE PROPOSED UTILITIES SHALL BE MADE TO CONFORM TO THE ACTUAL LOCATION, TAPPING POINT, DEPTH AND INVERT LEVELS OF ALL EXISTING
PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL GOVERNMENT / LOCAL CONSTRUCTION OPERATION PERMITS. OTHER PERMITS
REQUIRED BY ANY REGULATORY AGENCY.
Ø100 SEWAGE DISCHARGE PIPE TAP
10. EXTERIOR UNDERGROUND RAMP DISCHARGE PIPES SHALL BE HDPE PIPE & FITTINGS
TO CITY SEWER LINE
11. ALL WORKS SHALL BE DONE WITH UTMOST CARE AND HIGHEST LEVEL OF QUALITY AND SAFETY; WITH NO ADVERSE DISRUPTION TO EXISTING
UTILITIES AND / OR OPERATION.
LINE & GRADE
12. ANY EXISTING UTILITIES EQUIPMENT, PIPING OR PAVED AREAS AFFECTED SHALL BE RESTORED TO ORIGINAL CONDITION AND BE PROPERLY

13.
SCHEDULED PRIOR TO ACTUAL WORK WITH THE OWNER OR HIS AUTHORIZED REPRESENTATIVE.
ALL PIPES PENETRATING THRU WALLS, CEILING, FLOORS SHALL BE ACOUSTICALLY SEALED WITH STC FIRE RATED MATERIALS. FRO
1 COLD WATER LAYOUT 2 WASTE PIPE LAYOUT
ME
XIST P 1 SCALE
P 1 SCALE
14. EACH HORIZONTAL DRAINAGE PIPES SHALL BE PROVIDED WITH CLEANOUTS AS FOLLOWS: ING
WAT
ER
SUP
PLY
a. AT EVERY 15.0 METER LENGTH OR A FRACTION THEREOF,
b. AT EVERY CHANGE IN DIRECTION GREATER THAN 45 DEGREES,
WA
c. AT ITS UPPER TERMINAL TE
RT ARCHITECTURAL
AN
15. ALL VERTICAL PIPES IN THE CHASE (SHAFTS) SHALL BE ANCHORED IN WALLS OR COLUMNS. KPR
TAESS
WP NK UR
16. ALL SANITARY AND STORM DRAINAGE PIPES SHOWN IN THE DRAWINGS ARE LOCATED BELOW SLAB AND ALL PLUMBING, UNLESS OTHERWISE E
SPECIFIED.
17. ALL DIMENSIONS SHALL BE IN MILLIMETERS UNLESS OTHERWISE SPECIFIED IN THE DRAWING.
18. ALL PIPE SLEEVE LOCATIONS SHALL BE PROPERLY COORDINATED W/ STRUCTURAL DRAWING. H
HB B
71
19. WHERE SERVICES PENETRATE ANY FIRE RATED BARRIERS, THE CONTRACTOR SHALL SEAL THE PENETRATION WITH THE USE OF APPROPRIATE H
HB B
26
HB
MATERIALS TO ENSURE THE INTEGRITY OF THE FIRE BARRIER. H
HB
HB B
20. ALL PIPING PASS THRU-SEISMIC GAP SHALL BE PROVIDED W/ SUITABLE FLEXIBLE JOINT. LA
HB
HB STRUCTURAL
UN
DR
Y AR
EA
0.30m

LEGEND & SYMBOLS


SYMBOL DESCRIPTION
COLD WATER LINE PPR/HDPE
35
62 71 HOT WATER LINE PPR
26
WASTE PIPE PVC PIPE SERIES 1000
PLUMBING / SANITARY
35
2 6
SOIL PIPE PVC PIPE SERIES 1000
3 WATER METER DETAILS DIRECTION OF FLOW -
P 1 SCALE
FLOW DIRECTION -

PVC PIPE SERIES 1000 W/


CONDENSATE DRAIN
EXPANDED RUBBER INSULATION
COLD WATER LINE EQUIVALENT PIPE DIAMETER DRAIN PIPE PVC PIPE SERIES 1000

VENT PIPE PVC PIPE SERIES 1000


NOMINAL PIPE POLYPROPYLENE-RANDOM HIGH DENSITY POLYETHYLENE
DIAMETER (mm) (PPR) PIPE PN20 (mm) (HDPE) PIPE-PE 100/PN16 (mm) CONTINUOUS PIPE -

15 25 - EXISTING DRAIN PIPE -

20 32 -

25 40 -
EXISTING SOIL PIPE -
ELECTRICAL
PIPE UP -
32 50 -
Ø
TO 100 S
PIPE DOWN -
40 63 -
CITY EW FLOOR/GROUND CLEAN OUT BRASS
50 75 -

3 ISOMETRIC VIEW SEW AGE D CHECK VALVE BRASS


65 90 -
ER ISC GATE VALVE
75 110 -
P 1 SCALE LINE HAR
GE WATER METER ASSEMBLY (BY WATER PROVIDER)
100

150
-

-
125

180
PI PE T DRAIN PROVISION BRONZE

200 - 225
AP GREASE TRAP STAINLESS STEEL

SOIL STACK PVC PIPE SERIES 1000


MECHANICAL
VENT STACK PVC PIPE SERIES 1000

PROJECT TITLE OWNER SHEET NO.


SHEET CONTENTS

PLUMBING PLAN
LABADIVA LAUNDRY SHOP MS. JOANNA ALFONSO P
-
WATER LINE LAYOUT
WASTE PIPE LAYOUT
ISOMETRIC VIEW 1 1
PROFESSIONAL IN-CHARGE ADDRESS: ADDRESS:
PLUMBING
18A ROTC STREET, ROSARIO PASIG CITY 18A ROTC STREET, ROSARIO PASIG CITY PLAN