CP2102 Ek
CP2102 Ek
CP2102 E V A L U A T I O N K I T U S E R S G U I D E
1. Kit Contents
The CP2102 Evaluation Kit contains the following items:
CP2102 Evaluation Board CP210x Virtual COM Port Drivers CD-ROM RS232 Serial Cable USB Cable CP2102 Evaluation Kit Users Guide (this document)
2. Installing Drivers
The CD-ROM included with the CP2102EK Evaluation Kit contains the Virtual COM Port Drivers for the CP210x family of devices. The following files are included on the CD-ROM:
Driver unpack utility (CP210x_Drivers.exe) Version information document (Readme.txt) Documentation Directory - CP2102 data sheet - CP2102 Evaluation Kit User's Guide - CP210x Customization Guide (AN144) - Software Directory CP210x Customization Software (AN144SW.zip)
10. Check "Specify a location" and press Next. 11. Press Browse to locate the slabw2k.inf driver installation file. The default location is the "C:\SiLabs\MCU\CP210x\WIN" directory. Once this file is selected press OK. 12. Verify that the correct path and filename are shown and press Next. 13. Press Finish to finish installing the "CP210x USB to UART Bridge Controller".
CP2102-EK
CP2102-EK
2.3. Virtual COM Port Driver Installation Windows XP
Follow these steps to install the Windows XP VCOM driver:
1. 2. 3. 4. 5. 6. 7. 8. 9. Connect the USB cable between the host computer and the CP2102 target device. Windows will open a Found New Hardware Wizard window. Select "Install from a list or specific location (Advanced)" and press Next. Select "Include this location in the search". Press Browse to locate the "C:\SiLabs\MCU\CP210x\WIN" directory. Once this directory is selected press OK. Verify that the correct path and filename are shown and press Next. Press Finish to finish installing the "CP210x USB Composite Device". Windows will open a second Found New Hardware Wizard window. Select "Install from a list or specific location (Advanced)" and press Next.
10. Select "Include this location in the search". 11. Press Browse to locate the "C:\SiLabs\MCU\CP210x\WIN" directory. Once this directory is selected press OK. 12. Verify that the correct path and filename are shown and press Next. 13. Press Finish to finish installing the "CP210x USB to UART Bridge Controller".
10. Select "Specify a location". 11. Press Browse to locate the "C:\SiLabs\MCU\CP210x\WIN" directory. Once this directory is selected press Next. 12. Verify that the correct path and filename are shown and press Next. 13. Press Finish to finish installing the "CP210x USB to UART Bridge Controller".
Rev. 0.1
CP2102-EK
3. CP2102 Hardware Interface
The evaluation board is connected to a PC as shown in Figure 1. 1. 2. 3. 4. Connect one end of the USB cable to a USB Port on the PC. Connect the other end of the USB cable to the USB connector on the CP2102 evaluation board. Connect one end of the RS232 serial cable to the DB-9 connector on the CP2102 evaluation board. Connect the other end of the RS232 serial cable to the target serial device.
RS232
Rev. 0.1
RS232
PC
USB
Serial Device
CP2102-EK
5. Target Board
The CP2102 Evaluation Kit includes an evaluation board with a CP2102 device pre-installed for evaluation and preliminary software development. Numerous input/output (I/O) connections are provided to facilitate prototyping using the evaluation board. Refer to Figure 2 for the locations of the various I/O connectors. J1 J2 J3 J4 D1 DB9 connector for RS232 interface UART signal access connector USB connector for USB interface Not used SUSPEND indicator LED
SUSPEND SUSPEND
SUSPEND
J4
J2
J3 CP2102
J1
Pin 1
Pin 2
Description
VBUS DD+ GND (Ground)
Rev. 0.1
CP2102-EK
5.2. UART Signals (J1, J2)
A RS232 transceiver circuit and DB-9 connector (J1) are provided on the evaluation board to connect the CP2102 virtual serial port to external serial devices. See Table 2 for the RS232 J1 pin descriptions. The J2 connector is provided to facilitate direct access to the CP2102s UART signals. Shorting blocks on J2 are required to connect the UART signals to J1. See Table 3 for J2 pin descriptions.
Signal
DCD RXD TXD DTR GND DSR RTS CTS RI
CP2102 Direction
Input Input Output Output Input Output Input Input
Description
Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Ground Data Set Ready Request to Send Clear to Send Ring Indicator
Signal
TXD RXD DTR RI DCD DSR CTS RTS
CP2102 Direction
Output Input Output Input Input Input Output
Description
Transmit Data Receive Data Data Terminal Ready Ring Indicator Data Carrier Detect Data Set Ready Clear to Send Request to Send
Rev. 0.1
6
CP2102
CP2102 SUSPEND LED
6. Schematic
CP2102-EK
Rev. 0.1
CP2102-EK
Notes:
Rev. 0.1
CP2102-EK
Contact Information
Silicon Laboratories Inc. 4635 Boston Lane Austin, TX 78735 Tel: 1+(512) 416-8500 Fax: 1+(512) 416-9669 Toll Free: 1+(877) 444-3032 Email: [email protected] Internet: www.silabs.com
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice. Silicon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Silicon Laboratories assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Silicon Laboratories products are not designed, intended, or authorized for use in applications intended to support or sustain life, or for any other application in which the failure of the Silicon Laboratories product could create a situation where personal injury or death may occur. Should Buyer purchase or use Silicon Laboratories products for any such unintended or unauthorized application, Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages. Silicon Laboratories and Silicon Labs are trademarks of Silicon Laboratories Inc. Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holders.
Rev. 0.1