0% found this document useful (0 votes)
68 views

ECTE323 Power Engineering 2 - Tutorial 6: T e - Sin) T Sin (L R M V I 2 2 2

This document contains 6 questions related to power engineering concepts like rectifiers, voltage and current calculations, power factors, and resistor/capacitor filter design. The questions involve diode bridge rectifiers, half-wave rectifiers, calculating average and ripple voltages, conduction angles, resistor values for specific currents, reactive and apparent power values, and power factors.

Uploaded by

Akhilesh Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views

ECTE323 Power Engineering 2 - Tutorial 6: T e - Sin) T Sin (L R M V I 2 2 2

This document contains 6 questions related to power engineering concepts like rectifiers, voltage and current calculations, power factors, and resistor/capacitor filter design. The questions involve diode bridge rectifiers, half-wave rectifiers, calculating average and ripple voltages, conduction angles, resistor values for specific currents, reactive and apparent power values, and power factors.

Uploaded by

Akhilesh Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ECTE323 Power Engineering 2 UOWD

ECTE323 Power Engineering 2 – Tutorial 6

Q1 The voltage across a BJT during its 'turn on' period falls linearly from 200 V to 0 V in
1.0 µS. During the same period the current rises from 0 A to 100 A linearly. What is the
energy dissipated in the BJT during the turn on period? If the BJT is turned on and off at
a frequency of 5 kHZ what will be its switching power loss? Assume equal switching off
and switching on periods.

Q2 A single-phase half wave diode rectifier with an RL load (R=1 Ω and L=3.3 mH) is
supplied by a 240 V, 50 Hz supply. The extinction angle is 3.962 radians. Given that the
following expresses the current:

 t where   tan1 L
Vm   
i 
2 2 2 sin(t  )  sin .e  R
R  L  
 

Calculate:
(a) Average output voltage.
What would be the average output voltage for the following L and R values?
(b) For L = 0 and R = 1
(c) For R=0  and L = 3.3mH?

Q3 A battery charger is supplied by a 240 V, 50 Hz source. The charger consists of a single


diode and current limiting resistor (R) which is in series with the 12 V battery and a 4:1
step down transformer connected to the 240 V supply. The average charging (battery)
current required is 5 A. Calculate:
(a) Conduction angle of the diode
(b) Value of R (assuming a 5 A average current occurs when the battery is at 12 V).
(c) Power rating of R
(d) Rectifier efficiency

Q4 A single-phase half-wave rectifier is supplied from a 240 V, 50 Hz supply. The load


resistance is 500 . Design a C filter so that the ripple factor of the output voltage is less
than 5%. With the selected value of C what is the average value of the output voltage?
List any assumptions you make to do this problem. Check your solutions against
simulations where possible.

1
ECTE323 Power Engineering 2 UOWD

Q5 A three-phase diode bridge rectifier connected to a purely resistive load is supplied by


a three phase supply having a line voltage of VL = 415 V at 50 Hz. With the aid of
waveforms derive an expression for the average output voltage. What is the PIV of a
diode in this bridge?

Q6 A three-phase diode bridge rectifier supplies a highly inductive load. The supply line-
line voltage is 415 V and the real power drawn from it is 20 kW. Calculate the
following:
(a) Average load voltage.
(b) Average load current.
(c) Effective resistance of the load.
(d) Fundamental reactive volt-amperes drawn by the rectifier.
(e) Apparent volt-amperes drawn by the rectifier.
(f) AC supply side power factor.