Rhombic Antenna
Rhombic gain 8-10dBd
Un-Terminated Rhombic
<<<----->>> directions
Bidirectional
Terminated Rhombic
------->>> direction
Unidirectional
"A" 70 "B" 110
"A" 57 "B" 123
"A" 47 "B" 133
"R" = 800
Electrical
1
2
2
2
3
3
3
4
4
4
Freq. MHz.
"C"
"Y"
"X"
"C"
"Y"
"X"
"C"
"Y"
"X"
1.900
477.9
955.7
1096.2
1565.8
1433.6
1367.9
2519.8
1911.4
2606.8
2796.2
3.800
238.9
477.9
548.1
782.9
716.8
684.0
1259.9
955.7
1303.4
1398.1
7.200
126.1
252.2
289.3
413.2
378.3
361.0
664.9
504.4
687.9
737.9
10.100
89.9
179.8
206.2
294.6
269.7
257.3
474.0
359.6
490.4
526.0
14.250
63.7
127.4
146.2
208.8
191.1
182.4
336.0
254.9
347.6
372.8
18.135
50.1
100.1
114.8
164.1
150.2
143.3
264.0
200.3
273.1
293.0
21.300
42.6
85.3
97.8
139.7
127.9
122.0
224.8
170.5
232.5
249.4
24.910
36.4
72.9
83.6
119.4
109.3
104.3
192.2
145.8
198.8
213.3
28.500
31.9
63.7
73.1
104.4
95.6
91.2
168.0
127.4
173.8
186.4
29.600
30.7
61.3
70.4
100.5
92.0
87.8
161.7
122.7
167.3
179.5
52.100
209.1
418.2
479.7
685.2
627.4
598.6
1102.7
836.5
1140.8
1223.7
52.100
17.4
34.9
40.0
57.1
52.3
49.9
91.9
69.7
95.1
102.0
146.500
74.4
148.7
170.6
243.7
223.1
212.9
392.2
297.5
405.7
435.2
146.500
6.2
12.4
14.2
20.3
18.6
17.7
32.7
24.8
33.8
36.3
223.000
48.9
97.7
112.1
160.1
146.6
139.9
257.6
195.4
266.5
285.9
223.000
4.1
8.1
9.3
13.3
12.2
11.7
21.5
16.3
22.2
23.8
435.000
25.0
50.1
57.5
82.1
75.1
71.7
132.1
100.2
136.6
146.6
435.000
2.1
4.2
4.8
6.8
6.3
6.0
11.0
8.3
11.4
12.2
445.000
24.5
49.0
56.2
80.2
73.4
70.1
129.1
97.9
133.6
143.3
906.000
12.0
24.1
27.6
39.4
36.1
34.4
63.4
48.1
65.6
70.4
1268.000
8.6
17.2
19.7
28.2
25.8
24.6
45.3
34.4
46.9
50.3
2401.000
4.5
9.1
10.4
14.9
13.6
13.0
23.9
18.2
24.8
26.6
5668.000
1.9
3.8
4.4
6.3
5.8
5.5
10.1
7.7
10.5
11.2
NOTE: The gray shaded box can be changed by the user to any frequency with no impact to the data algorithm.
2
3
4
by N6JSX/8
File: Ant-Math-03.xls
Page 1 of 2
feet & 10ths
feet & 10ths
feet & 10ths
feet & 10ths
feet & 10ths
feet & 10ths
feet & 10ths
feet & 10ths
feet & 10ths
feet & 10ths
inches & 10ths
feet & 10ths
inches & 10ths
feet & 10ths
inches & 10ths
feet & 10ths
inches & 10ths
feet & 10ths
inches & 10ths
inches & 10ths
inches & 10ths
inches & 10ths
inches & 10ths
06/2007
Rhombic termination resistor
Termination resistor needs to be near 800
Resistors must be carbon resistance - not inductive.
Increased parallel resistor stages will increase overall input Wattage.
All resistors are carbon 5W, creating 10W max dissipation per leg.
Input W
10W
30W
50W
100W
300W
R1a/b
400
1200
2000
4000
12000
by N6JSX/8
File: Ant-Math-03.xls
R2a/b
none
1200
2000
4000
12000
R3a/b
none
1200
2000
4000
12000
R#a/b
none
none
2000
4000
12000
R# = 5
R# = 10
R# = 30
9dB ERP
80W
240W
400W
800W
2400W
Page 2 of 2
06/2007