XY-WJ01 Programmable Relay: Description
XY-WJ01 Programmable Relay: Description
Description:
Power: 6-30VDC
Quiescent Current: ~15 mA
Working Current: ~50 mA
Timing Range: 0.01 sec~9999 min
Trigger Signal: High-level: 3.0V~24V, low-level:
0.0V~0.2V Relay: SPST-NO Isolated Contacts
Contacts: 10A/14VDC, or 5A/110VAC
Operating Temperature: -40~85 °C
Connections: Terminal Strip
Service life: More than 100,000 times
Size: W:71 H:39 D:25 mm WT: 45gm
Features:
1. Liquid Crystal Display, the operating mode and settings are clear at a glance
2. Supports High & Low Level Triggering
One-button pause function with reverse connection protection
3. Optocoupler isolation, enhanced anti-interference ability, industrial grade circuit
4. Wide voltage supply (6~30V)
5. Reverse Polarity Protected
6. Sleep mode. After enabling, if there is no operation for ~5 minutes, Backlight turns off
Any button wakes up;
7. Different OP, CL, LOP parameters can be set. These parameters are independent of
each other and are saved separately.
8. All setting parameters are automatically saved after power-off.
Panel Functions
Relay Contact Closed Status & Time
Increase Set
Decrease
Current Mode Pause/Trigger
35874-RL
XY-WJ01 Programmable Relay
LOP: Loop Cycles: 1-9999 times, ·---· stands for infinite loop
1) P0: When Triggered, The Relay will stay ON for the OP time, then turn OFF.
Another input will not retrigger until after relay times out (OP time).
2)) P1 When Triggered, The Relay will stay ON for the OP time, then turn OFF.
Another input will restart timing if it occurs during OP time.
3)) P2: When Triggered, The Relay will stay ON for the OP time, then turn OFF.
Another Input will reset, stop the timing and turn off the Relay if it occurs during OP time
4)) P3: When Triggered, The Relay will stay OFF for time CL and then turn ON.
5)) P4: When Triggered, Relay will stay ON for time OP, then relay will turn OFF for CL time; then repeats
(loops) the above action. if another trigger signal occurs during a loop; Module will reset, stop
timing and relay will stay in present state. The number of cycles (LOP) can be set.
Relay will stay OFF at end of loop(s).
6)) P5: When Triggered, Relay will stay OFF for time CL then relay stay ON for time OP and then repeats
(loops) the above action. If another trigger signal occurs during a loop; Module will reset, stop
timing and relay will stay in present state. The number of cycles (LOP) can be set.
Relay will stay ON at end of loop(s).
7)) P6: At power On the Relay will stay ON for time OP without receiving a trigger signal; then relay stay
OFF for time CL and then repeats the above action. The number of cycles (loops) (LOP) can be
set. Relay will stay OFF at end of loop(s).
Trigger is not functional in this mode
8)) P7: At power ON Relay will stay OFF for time CL without receiving a trigger signal; then relay stay ON
for time OP and then repeats the above action. The number of cycles (loops) (LOP) can be set.
Relay will stay ON it end loop(s).
Trigger is not functional in this mode
9)) P8: Signal Hold function. Continuous Trigger Signal will Reset delay time and the relay will stay ON;
Relay turns OFF after delay time OP when the Trigger signal is removed. If another trigger signal
occurs during timing (OP), Delay time is Reset and timing OP starts over.
10)
0) P9: Signal Hold function. Continuous Trigger Signal will Reset delay time and the relay will stay OFF;
Relay turns ON after delay time CL when the Trigger signal is removed. If another trigger signal
occurs during timing (OP), Delay time is Reset and timing CL starts over.
NOTE:
P0-P7 modes: When the module is not timing, a short press of Pause/Trigger Button will start
timing. If the module is already timing, it will stop, relay will turn off and display screen will show a
flashing OFF.
P8~P9 modes: When timing; the Pause button is a trigger. Short/Long push use is not available
35874-RL
XY-WJ01 Programmable Relay
Basic Connections
High Level Trigger
Pigtail Cable
Trigger Signal Common
Yellow High Level Trigger
Low Level Trigger Black Trigger Common
Red Low Level Trigger
6.0-30VDC
Power
35874-RL
XY-WJ01 Programmable Relay
6-30VDC
LOAD
LOAD
6-30VDC
POWER
SOURCE
If AC Power If AC Power
Neutral Line