0% found this document useful (0 votes)
67 views2 pages

Please Enter Under Options - Settings: PV SOL Expert 6.0 (R3)

This document summarizes the results of a simulation of a proposed 60.06 kWp solar photovoltaic system in Kutina, Croatia. The system would include 182 solar panels tilted at 30 degrees, with a total area of 384.9 square meters. It would use two 36 kW inverters to convert the DC power to AC. The simulation estimates the system would produce 83,650 kWh of electricity per year, with 80.6% of the maximum possible output, and offset over 73,990 kg of CO2 emissions annually.

Uploaded by

Bogdan Janković
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views2 pages

Please Enter Under Options - Settings: PV SOL Expert 6.0 (R3)

This document summarizes the results of a simulation of a proposed 60.06 kWp solar photovoltaic system in Kutina, Croatia. The system would include 182 solar panels tilted at 30 degrees, with a total area of 384.9 square meters. It would use two 36 kW inverters to convert the DC power to AC. The simulation estimates the system would produce 83,650 kWh of electricity per year, with 80.6% of the maximum possible output, and offset over 73,990 kg of CO2 emissions annually.

Uploaded by

Bogdan Janković
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Please enter under Options-> Settings

_ _Project Name: _Solar System Design _6.2.2017._Variant Reference: _System Variant_


___ __ _

7 182 x alfasolar 2 x Fronius International


AR 80P - 330 330 W FRONIUS CL 36,0
13
30°; 0° 36,0kW

Own Use

Location: Kutina
Climate Data Record: Kutina (1986-2017)
PV Output: 60,06 kWp
Gross/Active PV Surface Area: 384,89 / 385,26 m2

PV Array Irradiation: 664.155 kWh


Energy Produced by PV Array (AC): 83.650 kWh
Energy to Grid: 83.649,7 kWh
Direct Use of PV Energy: 0 kWh
Energy from Grid: 201,7 kWh

System Efficiency: 12,6 %


Performance Ratio: 80,6 %
Inverter Efficiency: 94,3 %
PV Array Efficiency: 13,3 %
Specific Annual Yield: 1.389 kWh/kWp
CO2 Emissions Avoided: 73.990 kg/a

The results are determined by a mathematical model calculation. The actual yields of the photovoltaic system
can deviate from these values due to fluctuations in the weather, the efficiency of modules and inverters, and other factors.
The System Diagram above does not represent and cannot replace a full technical drawing of the solar system.

PV*SOL Expert 6.0 (R3) 1


System in Grid Connected Operation
Location: Kutina PV Output: 60,06 kWp
Climate Data Record: Kutina Gross/Active PV Surface Area: 384,9 m2 / 385,3
m2
Number of Arrays: 1

Array 1: Array Name


Output: 60,06 kW Ground Reflection: 20,0 %
Gross/Active Solar 384,9 m2 / 385,3 m2 Output Losses due to...
Surface Area:
PV Module 182 x deviation from AM 1.5: 1,0 %
Manufacturer: alfasolar deviation from Manufacturer's 2,0 %
Specification:
Model: AR 80P - 330 in Diodes: 0,5 %
Nominal Output: 330 W due to Pollution: 0,0 %
Power Rating Deviation: 0% Inverter 2x
Efficiency (STC): 15,6 % Manufacturer: Fronius
International
No. of Modules in Series: 7 Model: FRONIUS CL 36,0
MPP Voltage (STC): 283 V Output: 36,00 kW
Orientation: 0,0 ° European Efficiency: 95,3 %
Inclination: 30,0 ° No. of MPP Trackers: 1
Mount: with Ventilation MPP Tracking: 230 V To 500 V
Shade: No

Individual Appliances Total Consumption: 0 kWh


Individual Appliance 1 Model: User-Independent Appl. 0 kWh

Simulation Results for Total System


Irradiation onto Horizontal: 579.934 kWh Own Use: 201,7 kWh
PV Array Irradiation: 664.155 kWh Energy Produced by PV Array: 88.462 kWh
Irradiation minus Reflection: 641.654 kWh Solar Fraction: 0,0 %
Energy from Inverter (AC): 83.650 kWh System Efficiency: 12,6 %
Energy to Grid: 83.650 kWh Performance Ratio: 80,6 %
Consumption Requirement: 0 kWh Final Yield: 3,8 h/d
Direct Use of PV Energy: 0 kWh Specific Annual Yield: 1.389 kWh/kWp
Energy from Grid: 202 kWh Array Efficiency: 13,3 %

Solar Energy Consumption as Percentage of Total Cosumption

8.000

6.000
kWh

4.000

2.000

0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Energy from Inverter (AC) 83.650 kWh
Grid Feed-in 83.650 kWh

You might also like