Pro-Watch Software Suite: Installation Guide
Pro-Watch Software Suite: Installation Guide
Pro-Watch Software Suite: Installation Guide
5.0
7-901073V17 | May 2020
Installation Guide
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in
this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes
have been made. The information in this publication does not represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential
damages resulting from the furnishing, performance, or use of this material. HII disclaims all responsibility for the selec-
tion and use of software and/or hardware to achieve intended results.
This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this doc-
ument may be photocopied, reproduced, or translated into another language without the prior written consent of HII.
Copyright 2020 Honeywell International Inc. All rights reserved.
Web Address: www.honeywellaidc.com
Other product names or marks mentioned in this document may be trademarks or registered trademarks of other compa-
nies and are the property of their respective owners.
For patent information, refer to www.hsmpats.com.
Copyright © 2020 Honeywell. All rights reserved.
Pro-Watch name and logo are registered trademarks of Honeywell. All other
product and brand names are the service marks, trademarks, registered
trademarks, or registered service marks of their respective owners. Printed in the
United States of America. Honeywell reserves the right to change any information
in this document at any time without prior notice.
Microsoft and Windows are registered trademarks of Microsoft Corporation.
Windows Server is a trademark of Microsoft Corporation.
Ordering Information
Feedback
Honeywell Access Systems appreciates your comments about this manual. Please
visit us on the web at http://www.honeywellintegrated.com/ to post your
comments.
Chapter 1 Preface
1.1 Purpose of this Document............................................................................ 1
1.2 Warning: Personal Data ................................................................................. 1
1.3 Audience ............................................................................................................... 2
1.4 Pro-Watch Documentation Set .................................................................. 2
1.5 Compliance ......................................................................................................... 2
iv www.honeywell.com
Preface
In this preface...
Purpose of this Document
Audience
Compliance
Microsoft Windows Server Windows Server 2012/2012 R2, Windows Server 2016, or Windows
Server 2019 commended for the Pro-Watch Server. Pro-Watch does NOT support Windows NT
4.0, Windows 7, Windows 2000 Server, Windows 2003 Server, Vista, Windows XP, Windows 10
Home Edition, or Windows Server 2008/2008 R2.
Windows 8.1 Professional, or Windows 10 Professional Build 1607 or higher is recommended for
the Pro-Watch Client. Pro-Watch does NOT support Windows 7 or Windows 10 Home Edition.
Personal data is protected by the General Data Protection Regulation (2016/679) in Europe and
therefore the owners of personal data have obtained certain rights thanks to this regulation.
We strongly advise you to be fully aware of these owner ("data subjects") rights as well as which
limitations you have to obey regarding the use and distribution of this data.
1.5 Compliance
To obtain applicable EU compliance Declaration of Conformities for this product, please refer to
our website, http://www.security.honeywell.com/hsce/international/index.html.
For any additional information regarding the compliance of this product to any EU-specific
requirements, please contact:
2 www.honeywell.com
Pro-Watch 5.0 Installation
In this chapter...
Overview
Installing .Net Framework 4.7.2
Runtime Requirements
Operating Systems Supported
Database Systems Supported
Pro-Watch Software Suite Installation
Complete Installation
Server-Only Installation
Client (Complete) Installation
Terminal Client Installation
Database Only Installation
Custom Installation
Installing Pro-Watch - Final Steps
Upgrade Installation Process
Pro-Watch 5.0 product upgrade with SoftKey License
Silent Installation
2.1 Overview
This guide documents the installation of the Pro-Watch 5.0 software. Note that after you install
this software, you will also need to complete the Pro-Watch licensing procedure documented in
the Pro-Watch 5.0 Software Keys Guide 800-08123V17.
If Pro-Watch is installed on a drive other than the C:\ drive, Pro-Watch still requires at least 1.5
GB of free space for temporary file storage.
4 www.honeywell.com
Installing .Net Framework 4.7.2
Installing .Net Framework 4.7.2
The setup file and installation instructions in this guide are valid only for Pro-Watch Version 5.0 or
greater. Pro-Watch Software Suite Release 3.81 or greater must be already installed if you are
upgrading to Release 5.0.
Note: For enabling TLS 1.2 with Pro-Watch servers and clients, please refer to the Appendix A.
2. Select the I have read and accept the license terms check box and then click Install to
display Installation Progress screen.
The installation screen displays a status bar showing the progress of the installation. The process
takes several minutes. When the installation process is finished the wizard displays the Installa-
tion Complete screen.
3. Click Finish to complete the installation.
6 www.honeywell.com
Operating Systems Supported
Operating Systems Supported
8 www.honeywell.com
Pro-Watch Software Suite Installation
Pro-Watch Software Suite Installation
Below are the configuration options for installing a new instance of Pro-Watch Software Suite as
described in the section “Installing Pro-Watch - Preliminary Steps“ on page 10.
• Complete Pro-Watch Installation – Installs all of the Pro-Watch components. Provides full
server and client functionality.
• Server-Only Pro-Watch Installation – Installs only the Pro-Watch Server and configures the
database.
Note: Configuring the Pro-Watch database involves either installing a new database or
upgrading a pre-existing database to function with this version of Pro-Watch.
• Pro-Watch Client (Complete) – Installs only the Pro-Watch client applications.
• Pro-Watch Terminal Client – Installs only the Pro-Watch client terminal application.
• Pro-Watch Database Only – Configures the Pro-Watch database.
Note: Configuring the Pro-Watch database involves either installing a new database or
upgrading a pre-existing database to function with this version of Pro-Watch.
• Custom Pro-Watch Installation – Allows the installation of Pro-Watch components custom
selected from a list.
Note: The Custom Pro-Watch Installation option should only be used by advanced users
who understand what components of Pro-Watch are compatible with one another.
In addition to all the above types, there is also a process to upgrade an existing version of Pro-
Watch. This is described separately in the section “Upgrade Installation Process“ on page 34.
10 www.honeywell.com
Pro-Watch Software Suite Installation
Pro-Watch Software Suite Installation
3. Click the radio button to confirm agreement with the licensing terms and click Next to
display the feature installation screen.
4. Select the Pro-Watch Software Suite check-box
Explanation of Features
Select the appropriate check box for the available feature installation choices described in the
table below:
Feature
Installation Description
Options
12 www.honeywell.com
Pro-Watch Software Suite Installation
Pro-Watch Software Suite Installation
3. After you select the desired configuration option, in the Select SQL Version field select the
version that matches your version and click Next to display the first screen for the
installation process you have chosen.
Note: To install Pro-Watch to a folder other than the default, click Browse and select an
appropriate folder.
3. Select from the drop-down list the SQL version running on your machine.
Note: If you do not have SQL installed, a message will appear as below:
To change the installation path, click Browse to find and redefine the path.
Note: If you want to upgrade the existing Pro-Watch database, select the Upgrade Database check
box.
14 www.honeywell.com
Complete Installation
Complete Installation
8. Enter the correct Password and click Next to display the Configure Pro-Watch Database
screen.
Note: When you select SQL Express 2016 as your database, Pro-Watch displays a DOS
dialog box while the SQL DB is downloaded. Allow 5 to 10 minutes for the DOS dialog box
to display and do not close it before your system finishes with downloading the SQL DB.
9. For manual configuration, select the Manually Configure Database (Advanced Users
Only) check box, then type in the Database Server name and select the Instance Name
(that is, the Pro-Watch Database name) from the drop-down list. If the SQL server you want
to use is not in the list, type its name manually. When you have completed this
configuration screen, go to Step 8.
Caution: Manual configuration is recommended only for advanced users.
16 www.honeywell.com
Complete Installation
Complete Installation
10.To use the local database server on your machine, select the Use Local Database Server
check box. This selection hides the Database Server field, select a instance name from the
Instance Name drop-down list.
Note: The name you enter for the service account at initial login is the account name that
will enable you to log in to Pro-Watch.
11.Define the Database Path where Pro-Watch Database files (.ldf and.mdf file) is copied.
Click Browse to find and redefine the path.
12.Click Next to display the continuation of the Configure Pro-Watch Database screen where
you can create a new database.
13.To configure an existing database, leave the check box blank and select a Pro-Watch
Database Name from the drop-down list
OR
Select the check box and type in the name of the new database that you’re creating.
Note: To install the sample reports, select the Install sample Reports check box OR leave
the check box blank.
14.Click Next to display the Ready to Install the Program screen and go to “Installing Pro-Watch
- Final Steps“ on page 30 to finish the installation process.
18 www.honeywell.com
Server-Only Installation
Server-Only Installation
3. To change the installation path, click Browse to find and redefine the path.
5. Click Next to display the Ready to Install the Program screen and go to “Installing Pro-
Watch - Final Steps“ on page 30 to finish the installation process:
20 www.honeywell.com
Client (Complete) Installation
Client (Complete) Installation
Note: For Client (Complete) installation the Upgrade Database check box is not available.
4. For automatic configuration, select a Pro-Watch Server from the drop-down list. Click
Refresh to refresh the server list. Pro-Watch populates the associated Database Server
name and the Pro-Watch Database Name in their respective fields.
Note: If the server you want to connect to is not in the list, or if the Pro-Watch Server is not
currently running on this server, you must either start it or use the manual configuration.
5. For manual configuration, select the Manually Configure Pro-Watch Client (Advanced
Users Only) check box. Select a Database Server from the drop-down list and enter the
Pro-Watch Database Name. If the server you want to use is not in the list, type its name
manually.
Caution: Manual configuration is recommended only for advanced users.
6. Click Next to display the Ready to Install the Program screen and go to “Installing Pro-
Watch - Final Steps“ on page 30 to finish the installation process.
Note: If the program displays the following error message during installation, be sure the
TCP/IP protocol is enabled in the SQL Server Network Configuration:
22 www.honeywell.com
Client (Complete) Installation
Client (Complete) Installation
9. If the TCP/IP protocol is not enabled by default, double-click the TCP/IP option to display
its Properties screen:
10.For the Enabled field, select Yes from the drop-down list.
11.Click Apply and OK.
12.Stop, and then restart the MS SQL service to activate your changes.
24 www.honeywell.com
Terminal Client Installation
Terminal Client Installation
Note: For Terminal Client installation the Upgrade Database check box is not available.
3. Click Next to display the Ready to Install the Program screen and go to “Installing Pro-
Watch - Final Steps“ on page 30 to finish the installation process.
Note: If you do not have SQL installed, a message will appear as below:
3. In the Select SQL Version field, select the desired version of Microsoft SQL.
Note: If you want to upgrade the existing Pro-Watch database, select the Upgrade
Database check box.
26 www.honeywell.com
Database Only Installation
Database Only Installation
4. Click Next to display the Configure Pro-Watch Database screen (Figure 2-8).
Note: When you select SQL Express 2016 as your database, Pro-Watch displays a DOS
dialog box while the SQL DB is downloaded. Allow 5 to 10 minutes for the DOS dialog box
to display and do not close it before your system finishes with downloading the SQL DB.
5. For manual configuration, select the Manually Configure Database (Advanced Users
Only) check box, then type in the Database Server name and select the Instance Name
(that is, the Pro-Watch Database name) from the drop-down list. If the SQL server you want
to use is not in the list, type its name manually.
Caution: Manual configuration is recommended only for the advanced users.
6. To use the local database server on your machine, select the Use Local Database Server
check box. (See Figure 2-9.) This selection disables the Database Server field, so you must
either type in a new database name or select a local database from the Instance Name
drop-down list.
7. Click Next to display the continuation of the Configure Pro-Watch Database screen
(Figure 2-10).
8. To configure an existing database, leave the check box blank and select a Pro-Watch
Database Name from the drop-down list
OR
To configure a new database, select the check box and type in the name of the new database. To
install the new Pro-Watch database to a folder on the SQL server other than the default one, click
Browse and select a new path.
9. Click Next to display the Ready to Install the Program screen. and go to “Installing Pro-
Watch - Final Steps“ on page 30 to finish the installation process.
3. Select from the drop-down list the SQL version running on your machine.
Note: When you select SQL Express 2016 as your database, Pro-Watch displays a DOS
dialog box while the SQL DB is downloaded. Allow 5 to 10 minutes for the DOS dialog box
to display and do not close it before your system finishes with downloading the SQL DB.
4. To change the installation path, click Browse to find and redefine the path.
Note: If you want to upgrade the existing Pro-Watch database, select the Upgrade
Database check box.
28 www.honeywell.com
Custom Installation
Custom Installation
6. In this step you choose which components to install. To modify how a component is
installed, click on the icon for that component to view the choices:
7. Review the components and select the ones you want to install, and click Next.
8. The order of the remaining screens depends on your choices of components to install. If
you want to install a server (that is, you did not X it out), perform the steps listed in
“Complete Installation“ on page 14. If you do not want to install a server, mark it as
unavailable to be installed and click Next to display the Configure Pro-Watch Client screen
(Figure 2-13). Perform the steps in “Client (Complete) Installation“ on page 21 for the rest
of the procedure.
9. Go to “Installing Pro-Watch - Final Steps“ on page 30.
2. Click Install to display a status bar showing the progress of the installation.
30 www.honeywell.com
Installing Pro-Watch - Final Steps
Installing Pro-Watch - Final Steps
3. When the installation process is finished, click Next to display the InstallShield Wizard
Complete screen.
4. Click Finish. A small pop-up informs you that you have to reboot the PC for the installation
to take effect.
c. At the Pro-Watch Server Properties dialog box, select a Startup Type of Automatic (Delayed
Start), and click OK. This ensures that the Pro-Watch Server service starts each time you start up
Pro-Watch.
32 www.honeywell.com
Installing Pro-Watch - Final Steps
Installing Pro-Watch - Final Steps
34 www.honeywell.com
Upgrade Installation Process
Upgrade Installation Process
If you are installing Pro-Watch Server, select the Apply Update to Database check box (if you are
installing Pro-Watch Client, the check box is grayed out).
5. Click Next to display the License Information screen:
36 www.honeywell.com
Upgrade Installation Process
Upgrade Installation Process
7. When the installation is complete, the software automatically displays the message that
the installation is successful.
8. Click Finish. A small pop-up informs you that you have to reboot the PC for the patch to
take effect.
START Button
11. At the Services screen, click the Start button to start the Pro-Watch Server service. Click
OK to exit.
38 www.honeywell.com
Pro-Watch 5.0 product upgrade with SoftKey License
Pro-Watch 5.0 product upgrade with SoftKey License
40 www.honeywell.com
Silent Installation
Silent Installation
42 www.honeywell.com
Silent Installation
Silent Installation
Table 4: Command Line Parameters for Pro-Watch Suite Patch Silent Installation
Value (if
Parameter Description
any)
UPDATEDB Database update
INSTALLSAMPLEREPORTS Installing sample reports
Note: The above parameters are optional and case sensitive (all in capital letter). Users can pass
the parameter based on the feature they want to install. Only /S is mandatory for silent installation.
44 www.honeywell.com
Appendix A: TLS 1.2 Support
In this appendix...
Overview
Introduction
Enable TLS 1.2 - Steps required on all Pro-Watch machines
Mandatory MS Driver installation
Troubleshooting and Workarounds
A.1 Overview
This appendix includes integration notes for TLS 1.2.
A.2 Introduction
1. To Enable TLS 1.2 in all PW servers and clients: Refer to section "Steps for Enabling TLS 1.2
in All Pro-Watch Machines.”
2. Install MSOLEDBSQL and sqlncli.msi on the Pro-Watch machines. Refer to the section
"Mandatory MS Driver installation in All Pro-Watch Machines.” NOTE: Not required on Pro-
Watch SQL Database if installed on separate machine).
3. Start the Pro-Watch service. NOTE: If it fails to start, refer to the Troubleshooting section in
this document.
4. Mobile App and Web UI: Older Web API/UI Services must be uninstalled. Only the PW 5.0
Web API/UI services have to eb used for the Mobile App/Web Application UI to work with
TLS 1.2.
5. Pro-Watch Integrations: The applications below require specific versions to work with TLS
1.2:
46 www.honeywell.com
Enable TLS 1.2 - Steps required on all Pro-Watch machines
Enable TLS 1.2 - Steps required on all Pro-Watch machines
A.2.1 Notes
• No need to apply the LobbyWorks or SPCI patch if Pro-Watch was upgraded to 5.0 but TLS
1.2 is not enabled on the system.
• New installations of below will fail if TLS 1.2 is already enabled on the Server system. Refer to
'Troubleshooting and Workarounds' section for more details and workaround.
• LobbyWorks
• HSDK
• HAPI
SSL 2.0
· Client: DisabledByDefault 1
· Client: Enabled 0
· Server: DisabledByDefault 1
· Server: Enabled 0
SSL 3.0
· Client: DisabledByDefault 1
· Client: Enabled 0
· Server: DisabledByDefault 1
· Server: Enabled 0
·
TLS 1.0
· Client: DisabledByDefault 1
· Client: Enabled 0
· Server: DisabledByDefault 1
· Server: Enabled 0
TLS 1.1
· Client: DisabledByDefault 1
· Client: Enabled 0
· Server: DisabledByDefault 1
· Server: Enabled 0
48 www.honeywell.com
Mandatory MS Driver installation
Mandatory MS Driver installation
1. MSOLEDBSQL
(Setup available in HF folder. File Name: msoledbsql_18.2.1.0_x64.msi)
Note: While installing the MSOLEDBSQL driver, "Client Components" and "OLE DB Driver for SQL
Server SDK" must be selected. [Refer to the below screen-shot.]
2. 2.sqlncli.msi
(Setup available in HF folder. File Name: sqlncli.msi)
Note: While installing the sqlncli.msi driver, "Client Components" and "SQL Server Native Client
SDK" must be selected. [Refer to the below screen-shot.]
1. Need to install the MS SQL server update in Database machine for TLS 1.2 support. Refer
to the below link to get the proper update and install it.
https://support.microsoft.com/en-us/help/3135244/tls-1-2-support-for-micro-
soft-sql-server
1. For MSOLEDBSQL driver support, user may need to install Windows update depending on
the operating system, please refer to below link to get the appropriate update:
50 www.honeywell.com
Troubleshooting and Workarounds
Troubleshooting and Workarounds
https://docs.microsoft.com/en-us/sql/connect/oledb/applications/support-
policies-for-oledb-driver-for-sql-server?view=sql-server-2017
2. Install the MSOLEDBSQL driver on Pro-Watch server and client machines. Setup is
available in HF folder. File Name: msoledbsql_18.2.1.0_x64.msi
1. Install the latest SQL native client in All Pro-Watch Server and Clients. Setup is available in
HF folder. File Name: Attached sqlncli.msi
2. Windows update must be installed in Window 8.1 and Server 2k12 R2. Setup is available in
HF folder. File Name: Windows8.1-kb3106993-x64.msu
3. Net 4.7.2 must be installed in all Pro-Watch machines 4.5 and higher.
52 www.honeywell.com
Honeywell
135 West Forest Hill Avenue
Oak Creek, WI 53154 Honeywell – Europe
(414) 766-1700 Ph Boeblingerstrasse 17 Specifications subject to change without notice.
(414) 766-1798 Fax 71101 Schonaich © Honeywell. All rights reserved.
www.honeywellintegrated.com Germany Document 7-901073V17