FEATURES
• Type: Graphic
• Display format: 240 x 128 dots
• Built-in controller: Sanyo LC7981 (or equivalent)
• Duty cycle: 1/128
• + 5 V power supply
• Built-in N.V. (option)
• Compliant to RoHS directive 2002/95/EC
ELECTRICAL CHARACTERISTICS
STANDARD VALUE
ITEM SYMBOL CONDITION UNIT
MIN. TYP. MAX.
VDD L level 0.7 VDD - VDD
Input Voltage V
VIO H level - - 0.3 VDD
Supply Current IDD VDD = + 5 V 0 55 60 mA
- 20 °C - - -
0 °C 20.3 21.4 22.5
Recommended LC Driving
Voltage for Normal Temperature VDD to V0 25 °C 18.0 19.1 20.2 V
Version Module
50 °C 17.8 18.9 20.0
70 °C - - -
LED Forward Voltage VF 25 °C - 4.2 - V
LED Forward Current IF 25 °C - 900 1800 mA
CCFL Forward Voltage VF 25 °C - 250 590 VRMS
CCFL Forward Current IF 25 °C - - 5.5 mARMS
EL Power Supply Current IEL VEL = 110 VAC, 400 Hz - - 5.0 mA
OPTIONS
PROCESS COLOR BACKLIGHT
STN STN STN FSTN STN
TN None LED EL CCFL
Gray Yellow Blue B&W Color
x x x x x x x x
For detailed information, please see the “Product Numbering System” document.
DIMENSIONS in millimeters
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.