This document provides information about the control system for a machine. It includes a diagram labeling the main components as the control box, safety remote, relay PCB, I/O unit, NC unit, and remote I/O unit. Lines connect the input and output ports between each component to show the signal flow through the system.

Uploaded by

Tensaiga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
237 views2 pages

Remote IO Connection Overview

This document provides information about the control system for a machine. It includes a diagram labeling the main components as the control box, safety remote, relay PCB, I/O unit, NC unit, and remote I/O unit. Lines connect the input and output ports between each component to show the signal flow through the system.

Uploaded by

Tensaiga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Serial No.

306138

CONTROL BOX SAFETY REMOTE


RELAY PCB(AP1) I/0 UNIT (AP30) NC UNIT(A5) 1
2 4

1 3

2 4

2
3

4 RI01

CJ31
1 3

2 4

RI03

XP2

XP1
1 3

AP1
(I) X1300-X131F RI02

CJ32
(O) Y1300-Y131F
RI04
SS SPEC./OP.WORK MEASUREMENT
AP41 RI05

RI06

RI07
OP.ROBOT I/F
RI08
Mazak

AP21
ROTARY SW
"7"
JUMPER AP41

d .
"1-2"
ST/WORK REST"2-3"

ve
(OP.ADDITIONAL M CODE (I) X1400-X141F
HIGH PRESSURE COOLANT (O) Y1400-Y141F REMOTE I/O AP51

er
AUTO DOOR/GL DOOR"2-3")
ROTARY SW AP21 UNIT(AP51) (I) X1500-X151F
"7"

s
ST SPEC./OP.WORK REST (I) X1200-X121F (O) Y1500-Y151F

re
(X 1) (X 2)

JUMPER
AP42 "2-3" (O) Y1200-Y121F
(X 3) (X 4)

ROTARY SW
(X 5) (X 6)

ts
"7"
(X 7) (X 8)

AP22
(C N1 ) (C N2 )

gh
JP
JUMPER SW.
"OFF"

ri
SW

(C N3 )
Mazak

ll
.A
ROTARY SW
"6" AP42

N
JUMPER (I) X1420-X143F
ROTARY SW
"6"
AP22

O
"1-2"
(OP.ADDITIONAL M CODE (O) Y1420-Y143F (I) X1220-X123F REMOTE I/O

TI
JUMPER
HIGH PRESSURE COOLANT
AUTO DOOR/GL DOOR"2-3")
"1-2"
(O) Y1220-Y123F UNIT(AP52) AP52
38

OP.ADDITIONAL M CODE
A (X 1) (X 2)

(I) X1520-X153F
R
61

(X 3) (X 4)

(X 5) (X 6)

(O) Y1520-Y153F
PO

AP43
(X 7) (X 8)
30

(X 9) (X 10 )

(X 11 ) (X 12 )
R

ROTARY SW
(X 13 ) (X 14 )
o.

"6"
O

(X 15 ) (X 16 )

(C N1 ) (C N2 )
N

JUMPER SW.
C

AP71
JP

"OFF"
REMOTE I/O
al

UNIT(AP71)
K

(I) X1700-X171F
SW

(C N3 )
ri

ZA

ROTARY SW (O) Y1700-Y171F


"5"
Se

(X 1) (X 2)

(X 3) (X 4)

AP43
A

JUMPER (X 5) (X 6)

ROTARY SW
"1-2" (X 7) (X 8)

"7"
IM

(OP.HIGH PRESSURE COOLANT (I) X1440-X145F (C N1) ( CN 2)

AUTO DOOR/GL DOOR"2-3") JUMPER SW. MAGAZINE OPERATING PANEL


(O) Y1440-Y145F
JP

"OFF"
AP53
K

SW

(C N3 )

OP.HIGH PRESS COOLANT


ZA

AP44
A
M

REMOTE I/O
YA

UNIT(AP72) AP72 ROTARY SW


(OP.)VISUAL TOOL ID
ROTARY SW.2
"5"
(I) X1720-X173F "36MG:0"
"72MG/110MG:1"
3

( X1 ) ( X2 )

(O) Y1720-Y173F JUMPER


01

( X3 ) ( X4 )

"1-2"
ROTARY SW
AP53
( X5 ) ( X6 )

"4" ( X7 ) ( X8 )
)2

ROTARY SW
AP44
( CN 1) ( CN 2)

JUMPER JP
"6" (I) X1540-X155F
"1-2"
(O) Y1540-Y155F
(c

(OP.AUTO FRONT DOOR (I) X1460-X147F JUMPER SW.


GL TOP&SIDE DOOR"2-3") ( CN 3)
SW

"ON"
(O) Y1460-Y147F
ht
ig

OP.AUTO FRONT DOOR or


GL TOP & SIDE DOOR REMOTE I/O
yr

UNIT(AP62)
AP62
AP45 #50 MAGAZINE ONLY
op

( X1 ) ( X2 )
(I) X1620-X163F REMOTE I/O
(O) Y1620-Y163F UNIT(AP63) AP63
C

( X3 ) ( X4 )
Mazak

( X5 ) ( X6 )

(I) X1640-X164F
( X7 ) ( X8 )

( X9 ) (X 10 ) (X 1) (X 2)

(X 11 ) (X 12 ) (X 3) (X 4)

(O) Y1640-Y164F
ROTARY SW
(X 13 ) (X 14 ) (X 5) (X 6)

"6
(X 15 ) (X 16 ) (X 7) (X 8)

ROTARY SW
(C N1 ) (C N2 ) ( CN 1) ( CN 2)

ROTARY SW
"3" AP45 JP JP
"5"

#40 MAZAGINE JUMPER SW.


JUMPER (I) X1480-X149F SW SW

"ON"
JUMPER SW.
( CN 3) (C N3 )

"1-2"
(OP.GL IF"2-3") (O) Y1480-Y149F "ON"
#50 MAGAZINE
JUMPER SW.
OP.GL I/F OP.GL CONVEYOR "OFF"
AP47 AP25/AP26
APR'D BY CHK'D BY DRWN BY TITLE
18/01/29 18/01/29 18/01/29 REMOTE I/O
CONNECTION
H.INAGAKI K.KINOSHITA M.KOBAYASHI
YAMAZAKI MAZAK CORPORATION DRWN NO.
1 MODIRIED 2018.04.02 M.KOBAYASHI A14081100351 For mat versio n 1.0

This product is subject to all the applicable Japanese Foreign Exchange and Foreign Trade Law.
本品は『外国為替及び外国貿易法』に該当しますので外国に輸出する場合には同法に基づく許可を必要とします。
Serial No. 306138

CONTROL BOX
SAFETY REMOTE
RELAY PCB(AP1) I/0 UNIT (AP30) NC UNIT(A5)
2 4
1
1

1
3
4

3
GL OPERATING BOX
RI03
AP18
2 4

CJ31
1 3

2 4
XP2

XP1
1 3

Mazak
RI01 NC OPERATING PANEL
OP.HAND PULSE BOX
RI02

CJ32
RI04 AP18
ROTARY SW (I) X11E0-X11EF
RI05
"0"
JUMPER"1-2" (O) Y11E0-Y11EF
AP11
(OP.ENERGY DASHBOARD
RI06 HAND PLUSE BOX "2-3") (I) X1100-X111F
(O) Y1100-Y111F
RI07
ENERGY DASHBOARD
RI08
AP17

NC OPERATING PANEL

.d
ve
s er
A2

re
(I) X1340-X13FF

ts
ROTARY SW
"1" (O) Y1340-Y13FF

gh
JUMPER
"1-2"
(OP.HAND PLUSE BOX"2-3")

ri
ll
.A
N
O
TI
38

A
R
61

PO
30

R
o.

O
N

C
al

K
ri

ZA
Se

A
IM
K
ZA
A
M
YA
3
01
)2
(c
ht
ig
yr
op
C

APR'D BY CHK'D BY DRWN BY TITLE


18/01/29 18/01/29 18/01/29 REMOTE I/O
CONNECTION 2
H.INAGAKI K.KINOSHITA M.KOBAYASHI
YAMAZAKI MAZAK CORPORATION DRWN NO.
1 MODIRIED 2018.04.02 M.KOBAYASHI A14081100361 For mat versio n 1.0

This product is subject to all the applicable Japanese Foreign Exchange and Foreign Trade Law.
本品は『外国為替及び外国貿易法』に該当しますので外国に輸出する場合には同法に基づく許可を必要とします。

You might also like