Programmable
Thermostat RTH8500
Owner’s Manual
Installation is Easy
1. Label wires and remove your old thermostat
2. Install and wire your new thermostat
3. Set your new thermostat to match your heating/cooling system
• This thermostat works with virtually all System Types
• It is preset for the most common system
Customer assistance
For assistance with this product, please visit
http://yourhome.honeywell.com.
Or call Honeywell Customer Care toll-free at
1-800-468-1502.
2
Table of contents
Installation Programming and operation
Installation.............................................3 Setting the clock..................................14
Advanced Installation..........................10 Adjusting program schedules..............15
Overriding schedules temporarily.......15
About your new thermostat Overriding schedules permanently.....16
Controls and Home screen Filter reminder.....................................17
quick reference....................................13 Special features..................................18
Preset energy-saving schedules.........14 Replace batteries................................18
Appendices
Troubleshooting...................................19
Limited warranty..................................20
or
3
2 Remove Old Thermostat
Remove old thermostat but leave wallplate with wires attached.
If you have an older thermostat with a
Do not remove wallplate yet sealed mercury tube, turn to page 2
for proper disposal instructions.
Terminal C
designation C
MCR33823
Wire Labels
MCR31537
M28100 Terminal designation
+ +
M28334
Wallplate
4
5 Mount Wallplate
Mount the new wallplate using the included screws and anchors.
M27514
6 Connect Wires
Simply match wire labels.
If labels do not match letters on the thermostat, check “Alternate Wiring
(Conventional Systems)” on page 6 and connect to terminal as shown here
(see notes, below).
We are here to help. Call 1-800-468-1502 for wiring assistance.
SCREW
INSERT WIRES
THEN TIGHTEN SCREWS
LABELED WIRES
CONVENTIONAL CONVENTIONAL
WIRE HOLE
Y2 RC
Remove metal jumper
R
R
if you have both R
W
W and Rc wires.
Y
W2 Y
G
C
M27515
5
Alternate Wiring (Conventional Systems)
If labels do not match terminals, connect wires as shown here (see notes,
below).
RC Rc 2
R R 2
W W
Y Y
G G
C C 3
Y2 Y2
W2
W2
MCR28076
Remove metal jumper connecting R and Rc only if you must connect both
R and Rc wires.
If your old thermostat had both R and RH wires, remove metal jumper.
Connect the R wire to the Rc terminal, and the RH wire to the R terminal.
If your old thermostat had only 1 C or C1 wire, connect it to the C terminal.
If your old thermostat had 2 C or C1 wires, wrap each separately with
electrical tape and do not connect them.
SCREW
INSERT WIRES
THEN TIGHTEN SCREWS
LABELED WIRES
HEAT PUMP WIRE HOLE HEAT PUMP NOTE: If E and Aux do not
each have a wire connected,
RC use a small piece of wire to
L R connect them to each other.
R
O
E O/B
Aux
AUX Y
G
C
M27516
6
Alternate Wiring (For Heat Pumps Only)
3 5
4 6
MCR28077
7
7 Install Batteries
Install three AAA alkaline batteries and remove tab.
Remove tab
M28336
M28335
Back of thermostat
8 Install Thermostat onto Wallplate
Install thermostat onto the wallplate on the wall.
M28337
or
8
10 Set Time and Date
1. Press s or t to set date.
2. Press s or t to set month.
3. Press s or t to set year, then press DONE.
4. Press s or t to set time, then press DONE to save and exit.
TUE TUE
15
2006 6 1:00 PM 6
DONE DONE
M28338 M28339
If you are not sure of your system type or if you have other
questions, call us toll-free at 1-800-468-1502.
This thermostat works on 24 volt or 750 mV systems. It will NOT work on multi-
stage conventional systems.
9
Advanced Installation
Enter System Setup
1. Press SYSTEM.
2. Press and hold blank center key until the screen changes (approximately
5 seconds).
TUE
TUE
70
FAN
Inside Set To
70
70
FAN
AUTO
AUTO
Inside
Following
Set To
70
SYSTEM Schedule
SYSTEM
HEAT Outside
436:01
HEAT
6:01 AM
AM
70
FAN
Changing Settings
1. Press the s or t button to select
AUTO
Function
Inside Set To
Setting
70
function.
2. Press the s or t button to change
setting.
3. Press DONE to save & exit. 0120 20
NOTE: Some functions in the following
pages may not appear due to previous DONE
10
Function Description Setting
Press the s or t button to change the setting.
0170 Select System Type 1 Heat/cool: Gas, oil or electric heating with central air
conditioning.
2 Heat pump: Heat pump without backup or auxiliary heat.
3 Heat only: Gas, oil or electric heat without central air
conditioning.
4 Heat only with fan: Gas, oil or electric heat without central air
conditioning.
5 Hot water heat only (no fan): Gas, oil or hot water heat
without central air conditioning.
6 Cool only: Central air conditioning only.
7 Heat pump: Heat pump with backup or auxiliary heating.
8 Heat/Cool Multiple stages: 2 heat stages (wires on W and
W2), 2 cooling stages (wires on Y and Y2).
9 Heat/Cool Multiple stages: 2 heat stages (wires on W and
W2), 1 cooling stage (wire on Y).
10 Heat/Cool Multiple stages: 1 heat stage (wire on W), 2
cooling stages (wires on Y and Y2).
0180 Heating Fan Control 0 Gas or oil heat: Use this setting if you have a gas or oil
heating system (system controls fan operation).
1 Electric heat: Use this setting if you have an electric heating
system (thermostat controls fan operation).
0190 Heat Pump Changeover Valve 0 Cooling changeover valve: Use this setting if you connected
(for heat pumps only) a wire labeled “O” to the O/B terminal (see page 6).
1 Heating changeover valve: Use this setting if you connected
a wire labeled “B” to the O/B terminal (see page 7).
0240 Heating Cycle Rate 5 Gas or oil furnace: Standard gas/oil furnace (less than 90%
efficiency).
9 Electric furnace: Electric heating systems.
3 Heat pump, hot water or high-efficiency furnace: Hot water
system or gas furnace (more than 90% efficiency).
1 Gas/oil steam or gravity system: Steam or gravity heat
systems.
Settings 5, 9, 3, or 1 recommended. Other settings: 2, 4, 6, 7,
8, 10, 11, 12. The number indicates how frequently the system
cycles on and off to maintain the set temperature. A higher
number means the system is on and off for shorter amounts
of time, a lower number means longer on and off times. When
these settings are set to match the system type, the thermostat
controls temperature more accurately.
0270 Emergency Heat Cycle Rate 9 Electric furnace: Electric heating systems.
(heat pumps only)
0300 Manual/Auto Changeover 0 Manual changeover (Heat/Cool/Off).
1 Automatic changeover (Heat/Cool/Auto/Off). Automatically
turns on Heat or Cool based on room temperature. Note:
System maintains minimum 3°F difference between heat and
cool settings.
0320 Temperature Format (°F/°C) 0 Fahrenheit
1 Celsius
0330 Daylight Saving Time On/Off 0 Off: No adjustment for daylight saving time.
1 On: Auto-change to daylight saving time (for areas that do
not use the new 2007 DST calendar).
2 On: Auto-change to daylight saving time (2007 and beyond,
for areas that use the new 2007 DST calendar).
11
Function Description Setting
Press the s or t button to change the setting.
0500 Furnace Filter Change Reminder 0 Off (no reminder)
1 Reminder in about 1 month
2 Reminder in about 3 months
3 Reminder in about 6 months
4 Reminder in about 9 months
5 Reminder in about 1 year
6 Reminder in about 3 years
0530 Smart Response® Technology 1 On
0 Off
0640 Clock Format 12 12-hour clock (i.e., “3:30 pm”)
24 24-hour clock (i.e., “15:30”)
12
Thermostat controls
Press day(s) to set program schedule (see page 14).
Press FAN to select: Arrow keys
Auto: Fan runs only MON TUE WED THU FRI SAT SUN
Press to adjust
OK TO PICK MULTIPLE DAYS
when heating or cooling temperature or to make
70
FAN
system is on.
On: Fan runs
AUTO
Inside Set To
70 selections from screen
menus.
continuously. SYSTEM Following
Schedule
Clock
Press DONE to exit HEAT
Press to set clock.
and save settings. 6:01 AM
Screen
SCHED HOLD CLOCK SCREEN MORE
Press to lock keypad
M28373 for 30 seconds to clean
Press SYSTEM to select: screen.
Heat: Heating system control.
Cool: Cooling system control.
Auto: Thermostat automatically selects Hold More
heating or cooling depending on the Press to override Press for more options
indoor temperature. program schedule. (select models only).
Off: All systems off.
Em Heat: Emergency & Auxiliary Heat
control. Compressor is locked out.
Sched
(Select models only.)
Press to set program schedule.
Press DONE to exit and save settings.
Display screen
Current inside temperature. Current day of week. Temperature setting.
WED
70
FAN
AUTO
Inside Set To
70
SYSTEM Following
Schedule
Program schedule on
HEAT
Recovery
(does not display when off)
Current time. 6:01 AM
13
WED
70
FAN
AUTO
Inside Set To
70
Clock setting
1. To set the current time display,
press CLOCK, then press s or t
to adjust the time. Press and hold
6:01 WED
AM
70
FAN
s or t to advance the time more
quickly. AUTO
Inside
SCHED HOLD CLOCK Set
SCREEN
To
70
MORE
M28375
2. Press DONE to save & exit (or press
CANCEL to exit without changing the
time).
NOTE: The real-time clock should 6:02 AM
information.
NOTE: To change the current week
day display, see see System Setup in
your Installation Guide.
Program Schedule
You can program four time periods each day, with different settings for
weekdays and weekends. We recommend the pre-set settings (shown in the
table below), since they can reduce your heating/cooling expenses.
Wake - Set to the time you Heat Cool
awaken and the temperature you
want during the morning, until
you leave for the day.
Wake
(6:00 am) 70 ° 75 °
Leave - Set to the time you leave
home and the temperature you
Leave
(8:00 am) 62 ° 83 °
want while you are away (usually
an energy-saving level).
Return
(6:00 pm) 70 ° 75 °
Return - Set to the time you
return home and the temperature
you want during the evening,
Sleep
(10:00 pm) 62 ° 78 °
until bedtime.
Sleep - Set to the time you go to bed and the temperature you want overnight
(usually an energy-saving level).
NOTE: Leave and Return periods can be canceled on weekends.
14
70 70
Inside Set To
AUTO
WED
Following
Schedule
70
FAN
6:00 AM
Set To
70
Following
1. Press SCHED, then EDIT. SCHED HOLD CLOCK
Schedule
SCREEN MORE
2. Press day buttons (MON-SUN) to select
day(s). 6:00 AM M28379
you’ve programmed for the current SCHED HOLD CLOCK SCREEN MORE
15
Program schedule override (permanent)
Press HOLD to permanently adjust WED
the temperature. This will turn off the
program schedule.
70
FAN
Hold
SCHED HOLD CLOCK SCREEN MORE
CANCEL
M28383
70
FAN
schedule for extended periods of time.
Press s or t to set the temperature you
AUTO
Inside Set To
55
want, then press s or t to set the time SYSTEM
70
FAN
If you return earlier than expected, press SCHED HOLD CLOCK SCREEN MORE
CANCEL
CANCEL (or SCHED) to cancel “Hold” and M28385
resume the program schedule.
16
WED
SCREEN LOCKED
70
FAN
AUTO
Inside Set To
70
Screen cleaning Following
Schedule
M28387
70
FAN
furnace filter reminder alerts you when
it is time to replace your filter.
AUTO
Inside Set To
55
Press RESET after changing the filter, to SYSTEM RESET
DONE
M28389
17
Special features
Smart Response Technology: This feature allows the thermostat to
®
“learn” how long the furnace and air conditioner take to reach programmed
temperature settings, so the temperature is reached at the time you set. For
example: Set the Wake time to 6 am, and the temperature to 70°. The heat will
come on before 6 am, so the temperature is 70° by the time you wake at 6.
The message “Recovery” is displayed when the system is activated before a
scheduled time period.
Compressor Protection: This feature forces the compressor to wait a few
minutes before restarting, to prevent equipment damage. During the wait time,
the message “Wait” is displayed on screen.
Auto Changeover: This feature is used in climates where both air conditioning
and heating are used on the same day. When the system is set to Auto,
the thermostat automatically selects heating or cooling depending on the
indoor temperature. Heat and cool settings must be at least 3 degrees apart.
The thermostat will automatically adjust settings to maintain this 3-degree
separation.
CAUTION: To avoid possible compressor damage, do not use Auto
Changeover if the outside temperature drops below 50°F (10°C).
M28391
18
Troubleshooting
If you have difficulty with your thermostat, please try the following suggestions.
Most problems can be corrected quickly and easily.
Display is blank • Check circuit breaker and reset if necessary.
• Make sure power switch at heating & cooling system is on.
• Make sure furnace door is closed securely.
• Make sure fresh AAA alkaline batteries are correctly installed.
Temperature Make sure heating and cooling temperatures are set to acceptable
settings do not ranges:
change • Heat: 40° to 90 °F (4.5° to 32 °C).
• Cool: 50° to 99 °F (10° to 37 °C).
Heating or • Press SYSTEM to set system to Heat. Make sure the temperature
cooling system is set higher than the Inside temperature.
does not respond • Press SYSTEM to set system to Cool. Make sure the temperature
is set lower than the Inside temperature.
• Check circuit breaker and reset if necessary.
• Make sure power switch at heating & cooling system is on.
• Make sure furnace door is closed securely.
• Wait 5 minutes for the system to respond.
Cannot change • Check Function 0170: System Type to make sure it is set to
system setting match your heating and cooling equipment.
to Cool
Fan does not • Check Function 0180: Heating Fan Control to make sure it is set
turn on when to match your heating equipment.
heat is required
Heating system • Check Function 0170: System Type to make sure it is set to
is running in cool match your heating and cooling equipment.
mode
Red light is on • If thermostat is in Emergency Heat mode the red light is normal.
It shows that the thermostat is in emergency heat mode.
• If thermostat is not in Emergency Heat mode, contact a qualified
service contractor for repair.
“Wait” appears • Compressor protection feature is engaged. Wait 5 minutes for the
on the screen system to restart safely, without damage to the compressor.
Heat pump • Check Function 0190: Heat Pump Changeover Valve to make
issues cool air sure it is properly configured for your system.
in heat mode, or
warm air in cool
mode
For assistance with this product, please visit http://yourhome.honeywell.com or
call Honeywell Customer Care toll-free at 1-800-468-1502.
19
1-year limited warranty
Honeywell warrants this product, excluding battery, to be free from defects in the
workmanship or materials, under normal use and service, for a period of one (1) year
from the date of purchase by the consumer. If at any time during the warranty period the
product is determined to be defective or malfunctions, Honeywell shall repair or replace it
(at Honeywell’s option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it; or
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the
determination whether the product should be returned to the following address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN
55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply
if it is shown by Honeywell that the defect or malfunction was caused by damage which
occurred while the product was in the possession of a consumer.
Honeywell’s sole responsibility shall be to repair or replace the product within the terms
stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE
OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY,
EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states
do not allow the exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. This warranty gives you specific legal rights, and you may
have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Honeywell Customer
Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.
Services à la clientèle
Pour obtenir de l’aide avec ce produit, veuillez
consulter le site
http://yourhome.honeywell.com.
ou vous adresser aux Services à la clientèle de
Honeywell en composant le 1-800-468-1502.
2
Table des matières
Installation Programmation et fonctionnement
Installation.............................................3 Réglage de l’horloge...........................14
Guide d’installation avancé.................10 Réglage des programmes...................15
Dérogation temporaire
À propos du thermostat de la programmation...........................15
Aide-mémoire sur les commandes Dérogation permanente
et l’écran d’accueil..............................13 de la programmation...........................16
Programmes d’économie Changer le filtre...................................17
d’énergie préconfigurés......................14 Caractéristiques spéciales..................18
Remplacement des piles.....................18
Annexes
Dépannage..........................................19
Garantie limitée...................................20
ou
Disjoncteur Interrupteur
M31535
d’alimentation du système
de chauffage/refroidissement
3
2 Retirer l’ancien thermostat
Retirer l’ancien thermostat, mais laisser en place la plaque murale et les fils
sans les détacher.
Si vous possédez un thermostat plus ancien à tube
Laisser la plaque de mercure scellé, allez à la page 2 pour les
de montage en instructions de mise au rebut correctes.
place
Désignation de C
la borne C
Étiqueter les fils au fur et à mesure qu’ils sont débranchés à l’aide des
étiquettes fournies, puis retirer l’ancienne plaque murale. La couleur des fils ne
correspondra peut-être pas avec les étiquettes.
Étiquettes de fils
MCR31537
M28100 Désignation de la borne
+ +
M28334
Plaque de montage
4
5 Installer la plaque
Installer la nouvelle plaque murale à l’aide des vis et des chevilles d’ancrage
fournies.
M27514
VIS
Y2 RC
Retirer le cavalier
R
R
en métal s’il y a
W
W2 Y
G
C
MF27515
5
Câblage alternatif (systèmes classiques)
Si les étiquettes ne correspondent pas aux bornes, les raccorder comme
l’indique l’explication ci-dessous (voir les notes ci-dessous).
RC Rc
ou 2
R R 2
ou ou ou
W W
ou ou
Y Y
ou ou
G G
ou
C C
ou ou ou 3
Y2 Y2
W2
W2
MFCR28076
Câblage (Thermopompe)
Si les étiquettes ne correspondent pas aux lettres marquées sur le thermostat,
se reporter à la page 7.
VIS
à l’autre.
O
E O/B
Aux
AUX Y
G
C
MF27516
6
Autre option de câblage (pour thermopompes seulement)
ou
2
ou ou
3
ou ou
ou ou
ou
3 5
ou ou
5
ou
6
ou ou
4 6
ou ou ou
MFCR28077
7
7 Installer les piles
Installer 3 piles alcalines AAA à l’arrière du thermostat et retirer l’onglet.
Retirer
l’onglet.
M28336
M28335
Dos du thermostat
M28337
ou
Disjoncteur InterrupteurM31544
d’alimentation
du système de chauffage/
refroidissement
8
10 Régler l’heure et date
1. Appuyer sur s ou t pour régler la date.
2. Appuyer sur s ou t pour régler le mois.
3. Appuyer sur s ou t pour régler l’année, puis appuyer sur DONE.
4. Appuyer sur s ou t pour régler l’heure puis appuyer sur DONE pour
sauvegarder et quitter.
TUE TUE
15
2006 6 1:00 PM 6
DONE DONE
M28338 M28339
9
Guide d’installation avancé
Entrer les réglages du système
1. Appuyer sur SYSTEM.
2. Appuyer sur la touche du centre blanche et continuer à le faire jusqu’à ce
que l’affichage change (environ 5 secondes).
TUE
TUE
70
FAN
Inside Set To
70
70
FAN
AUTO
AUTO
Inside
Following
Set To
70
SYSTEM Schedule
SYSTEM
HEAT Outside
436:01
HEAT
6:01 AM
AM
Paramètre
70
la fonction.
2. Appuyer sur s ou t pour modifier les
paramètres.
3. Appuyer sur DONE pour sauvegarder et 0120 20
quitter.
REMARQUE : Certaines fonctions décrites DONE
M28341
dans les pages suivantes peuvent ne pas
apparaître en raison des choix faits aux
étapes précédentes.
10
Fonction Description Réglage
Appuyer sur s t pour modifier les paramètres.
0170 Type de système 1 Chauff./Clim. : Gaz, mazout ou chauffage électrique avec
climatisation.
2 Thermopompe : 1 chauffage (sans de chauffage aux.).
3 Chauff. seulement : Gaz, mazout ou chauffage électrique
sans climatisation.
4 Chauffage seulement avec ventilateur (gaz, mazout ou
chauffage électrique).
5 Chauff. eau chaude sans ventilateur (gaz, mazout ou
chauffage eau chaude).
6 Climatisation centrale seulement.
7 Thermopompe (avec chauffage aux.).
8 Multi-étages : 2 étages de chauffage (fils W et W2), 2 étages
de climatisation (fils Y et Y2).
9 Multi-étages : 2 étages de chauffage (fils sur W et W2), 1
étage de climatisation (fil Y).
10 Multi-étages : 1 étage de chauffage (fil W), 2 étages de
climatisation (fils Y et Y2).
0180 Commande du ventilateur de 0 Chauffage gaz/mazout : Système gaz/mazout (Le système
chauffage commande le fonctionnement du ventilateur).
1 Chauffage électrique : (Le thermostat commande le
fonctionnement du ventilateur).
0190 Vanne d’inversion (pour 0 Vanne de climatisation : Utiliser ce réglage si le fil étiqueté
thermopompes seulement) «O» a été raccordé à la borne O/B (voir la page 6).
1 Vanne de chauffage : Utiliser ce réglage si le fil étiqueté «B» a
été raccordé à la borne O/B (voir la page 7).
0240 Longueur des cycles de 5 Système de chauffage standard au gaz ou au mazout -
chauffage efficacité à moins de 90 %
9 Systèmes de chauffage électriques
3 Thermopompe, système de chauffage à eau chaude ou au
gaz - efficacité à plus de 90 %.
1 Système de chauffage au gaz ou au mazout : Vapeur ou
gravité
Réglages recommandés 5, 9, 3 ou 1. Autres réglages : 2, 4,
6, 7, 8, 10, 11, 12. Le nombre indique la fréquence à laquelle
le système effectue un cycle marche et arrêt pour maintenir la
température réglée. Un chiffre plus haut signifie que le système
fonctionne et s’arrête pour de plus courtes périodes de
temps, un chiffre plus bas signifie de plus longues périodes de
fonctionnement et d’arrêts. Lorsque ces réglages sont adaptés
au type de système, le thermostat contrôle la température de
façon plus efficace.
0270 Longueur des cycles de 9 Systèmes de chauffage électriques
chauffage de secours
(thermopompes seulement)
0300 L’inversion manuel ou 0 L’inversion manuel (Heat/Cool/Off).
automatique 1 L’inversion automatique (Heat/Cool/Auto/Off). Remarque : le
système maintient un écart minimal de 3 ˚F entre les réglages
du chauffage et du refroidissement.
0320 Format de la température 0 Fahrenheit
(°F/°C) 1 Celsius
11
Fonction Description Réglage
Appuyer sur s t pour modifier les paramètres.
0330 Changement horaire été 0 OFF : L’horaire d’été est désactivé.
1 ON : Changement automatique à l’heure avancée (pour
les zones qui n’utilisent pas le nouveau calendrier d’heure
avancée de 2007)
2 ON : Changement automatique à l’heure avancée (pour les
zones qui utilisent le nouveau calendrier d’heure avancée de
2007 et des années subséquentes)
0500 Rappel de changement du filtre 0 Arrêt (pas de rappel de changement de filtre du système de
du système de chauffage chauffage).
1 Rappel après 1 mois.
2 Rappel après 3 mois.
3 Rappel après 6 mois.
4 Rappel après 9 mois.
5 Rappel après 1 an.
6 Rappel après 3 ans.
0530 Technologie Smart Response ®
1 Marche
(marche/arrêt) 0 Arrêt
0640 Format de l’heure 12 Horloge 12 heures (3:30 pm)
24 Horloge 24 heures (15:30)
À propos du thermostat
Félicitations! Vous venez d’acheter le thermostat le plus perfectionné et le plus
facile à utiliser du monde. Il est conçu pour vous procurer de nombreuses
années de service fiable et assurer la régulation de la température ambiante
avec facilité par écran tactile.
• Programmes de 7 jours maximisant confort et économie.
• Programmation tout confort : il suffit de retirer le thermostat du mur pour
établir les programmes.
• Dérogations aux réglages de température prévus à tout moment à l’aide
d’une seule touche.
• Réglage précis de la température maintenant la température à 1 ˚F du point
de consigne.
• Rappels qui avisent l’utilisisateur de vérifier ou de changer les filtres et les
piles.
• Grand affichage à touches tactiles rétro-éclairé facile à lire, même dans
l’obscurité.
12
Commandes de thermostat
Appuyer sur les jours pour programmer les réglages (voir page 14).
Appuyer sur FAN pour Boutons de flèches
sélectionner : MON TUE WED THU FRI SAT SUN
Appuyer sur ces
OK TO PICK MULTIPLE DAYS
Auto: Ventilateur touches pour régler la
70
FAN
fonctionne seulement quand
le système de chauffage ou
AUTO
Inside Set To
70 température, ou pour faire
des choix à partir des
de refroidissement est en SYSTEM Following
Schedule
menus affichés à l’écran.
marche. HEAT
Clock
On: Le ventilateur Appuyer pour régler
fonctionne sans interruption. 6:01 AM
l’horloge.
Appuyer sur DONE pour SCHED HOLD CLOCK SCREEN MORE Screen
enregistrer les modifications M28373
Appuyer pour verrouiller
et quitter le mode de le clavier numérique
réglage. pendant 30 secondes afin
de nettoyer l’écran.
Appuyer sur SYSTEM pour sélectionner :
Heat : Commande le système de chauffage. Hold More
Cool : Commande le système de Appuyer pour Appuyer pour obtenir
refroidissement. déroger au d’autres options (certains
Auto : Le thermostat sélectionne programme. modèles seulement).
automatiquement le chauffage ou la climatisation
en fonction de la température intérieure. Sched
Off : Tous les systèmes sont à l’arrêt. Appuyer pour programmer
Em Heat : Commande le fonctionnement du système de les réglages.
chauffage d’urgence et du système de chauffage d’appoint. Le
compresseur est mis sous sécurité. (Certains modèles seulement.)
Appuyer sur DONE pour enregistrer les modifications et quitter le mode de réglage.
Écran d’affichage
Température intérieure Jour de la semaine en cours. Réglage du point de
actuelle. consigne.
WED
70
FAN
AUTO
Inside Set To
70
SYSTEM Following
Schedule
Programme en cours (ne
HEAT
Recovery
s’affiche pas lorsqu’il n’est
pas en fonctionnement).
Heure actuelle. 6:01 AM
70
FAN
AUTO
Inside Set To
70
Réglage de l’horloge
1. Pour régler l’affichage de l’heure
actuelle, appuyer sur CLOCK, puis
sur s ou t pour modifier l’heure.
6:01 AM
WED
70
FAN
Appuyer sur les touches s ou t
et maintenez-les enfoncées pour AUTO
Inside
SCHED HOLD CLOCK Set
SCREEN
To
70
MORE
M28375
avancer l’heure plus rapidement.
2. Appuyer sur DONE pour sauvegarder
et quitter (ou appuyer sur CANCEL
pour quitter sans modifier l’heure). 6:02 AM
Dérogation au programme
Vous pouvez programmer quatre périodes de temps par jour avec des
réglages différents pour les jours de semaine et les fins de semaine. Nous
recommandons ces préréglages (illustrés dans le tableau ci-dessous) puisqu’ils
peuvent réduire les dépenses de chauffage et de refroidissement.
Wake (Lever) - Réglez à l’heure du
lever et à la température voulue le Chauffage Climatisation
matin, jusqu’à votre départ.
Leave (Départ) - Réglez à l’heure
du départ de la maison et à la
Lever
(06:00) 70 ° 78 °
température voulue durant votre
absence (en règle générale, un
Départ
(08:00) 62 ° 85 °
niveau d’économie d’énergie).
Return (Retour) - Réglez à l’heure
Retour
(18:00) 70 ° 78 °
de votre retour à la maison et à
la température que vous voulez
durant la soirée, jusqu’au coucher.
Sommeil
(22:00) 62 ° 82 °
Sleep (Sommeil) - Réglez à
l’heure du coucher et à la température voulue durant votre sommeil (en règle
générale, un niveau d’économie d’énergie).
REMARQUE : Les périodes de départ et de retour peuvent être annulées les
fins de semaine.
14
70 70
Inside Set To
AUTO
WED
Following
Schedule
6:00
AUTO
Inside
AM
Set To
70
Following
1. Appuyer sur SCHED, puis sur EDIT. SCHED HOLD CLOCK
Schedule
SCREEN MORE
2. Appuyer sur les touches des jours (MON-
SUN) pour sélectionner les jours. 6:00 AM M28379
consigne de chacune.
6. Appuyer sur DONE pour sauvegarder
6:00 AM
78 COOL
15
Dérogation au programme (permanente)
Appuyer sur HOLD pour modifier WED
le point de consigne de manière
permanente et suspendre le
70
FAN
Hold
reprendre le programme. SCHED HOLD CLOCK SCREEN MORE
CANCEL
M28383
fois sur HOLD, et appuyer ensuite sur s SCHED HOLD CLOCK SCREEN MORE
ou t pour sélectionner le nombre de
70
FAN
jours. AUTO
Inside Set To
55 CANCEL
M28384
16
WED
SCREEN LOCKED
70
FAN
AUTO
Inside Set To
70
Nettoyage de l’écran Following
Schedule
70
FAN
l’installation, la fonction de rappel de
remplacement du filtre de l’appareil
AUTO
Inside Set To
55
de chauffage sera activée lorsque le SYSTEM RESET
temps sera venu de remplacer le filtre. HEAT
17
Caractéristiques spéciales
Technologie Smart Response : Permet au thermostat «d’apprendre»
®
M28391
18
Dépannage
Si vous éprouvez des difficultés, nous vous proposons d’essayer les solutions
suivantes. La plupart des problèmes peuvent être corrigés rapidement et
facilement.
Rien n’apparaît à • S’assurer que le coupe-circuit n’est pas déclenché et le remettre en position
l’écran de marche au besoin.
• S’assurer que le bouton de marche-arrêt du système de chauffage ou de
refroidissement est à la position de marche.
• S’assurer que la porte de l’appareil de chauffage est bien fermée.
• S’assurer qu’il y a bien des piles alcalines AAA neuves en place.
Le thermostat S’assurer que les températures de chauffage et de refroidissement sont réglées
ne réagit pas quand à l’intérieur des seuils de température permis :
on appuie sur les • Chauffage : 4,5 à 32 °C (40 à 90 °F).
touches (ou la • Refroidissement : 10 à 37 °C (50 à 99 °F).
température ne
change pas).
Le système de • Appuyer sur SYSTEM pour régler le système en mode de chauffage. S’assurer
chauffage ou de que le point de consigne est plus élevé que la température ambiante.
refroidissement ne • Appuyer sur SYSTEM pour régler le système au mode de refroidissement.
répond pas S’assurer que le point de consigne est moins élevé que la température
ambiante.
• S’assurer que le coupe-circuit n’est pas déclenché et le remettre en position
de marche au besoin.
• S’assurer que le bouton de marche-arrêt du système de chauffage ou de
refroidissement est à la position de marche.
• S’assurer que la porte de l’appareil de chauffage est bien fermée.
• Le message «Wait» à l’afficheur indique que la minuterie de protection du
compresseur est en marche. Attendre 5 minutes pour que le système se
remette en marche en toute sécurité sans endommager le compresseur.
Impossible de • Vérifier la Fonction 170 : Type d’installation pour s’assurer que le réglage
changer le réglage correspond aux systèmes de chauffage et de climatisation.
du système à
climatisation
Ventilateur ne • Vérifier la Fonction 180 : Commande du ventilateur de chauffage pour
démarre pas lors de s’assurer que le réglage correspond au système de chauffage.
l’appel de chauffage
Chauffage • Vérifier la Fonction 170 : Type de système pour s’assurer que le réglage
fonctionne en mode correspond aux systèmes de chauffage ou de climatisation.
climatisation
Le voyant rouge est • Si le thermostat est en mode de la chaleur de secours la lumière rouge est
allumé normale. Elle prouve que le thermostat est en mode de la chaleur de secours.
• Si le thermostat n’est pas en mode de la chaleur de secours, entrez en
contact avec un entrepreneur qualifié de service pour la réparation.
« Wait » apparaît sur • La fonction de protection du compresseur est engagée. Attendre 5 minutes
l’écran pour que le système redémarre sans risque d’endommager le compresseur.
Thermopompe • Vérifier la Fonction 190 : Vanne d’inversion de la thermopompe pour
émet de l’air froid s’assurer qu’elle est configurée pour convenir au système.
en mode chauffage
et de l’air chaud en
mode climatisation