0% found this document useful (0 votes)
34 views1 page

Ceiling Load Calculation - 1.958m

The document discusses the load calculation for a beam that is 1.958 meters long and 1.8 meters wide for a proposed 6-storey police building. It provides calculations for ceiling weight, total dead load, live load, factored live load, dead load shear at support, and live load shear at support.

Uploaded by

MohMohk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views1 page

Ceiling Load Calculation - 1.958m

The document discusses the load calculation for a beam that is 1.958 meters long and 1.8 meters wide for a proposed 6-storey police building. It provides calculations for ceiling weight, total dead load, live load, factored live load, dead load shear at support, and live load shear at support.

Uploaded by

MohMohk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PROPOSED CONSTRUCTION OF A 6-STOREY POLICE BUILDING WITH 2-BASEMENT ON MK17-10912V AT

Project :
TOA PAYOH LORONG 8 (TOA PAYOH PLANNING AREA).

Design code SS EN 1991-1-1 Job No. - Client


Designed Date 22/04/2022
Subject Load Calcualtion for Beam (L =1958mm)
Checked Rev: No. -

Load Calculation for Ceiling Load

L
Load Type 1

Span length, L = 1.958 m


Width, B = 1.80 m

Ceiling weight, SDL = 2.2 kN/m2


= 2.20 kN/m
B
Total dead load, W,DL = 1.98 kN/m
Live load, LL = 0.5 kN/m2
Factored live load, W,LL = 0.45 kN/m
L

DL Shear at Support, VDL = W,DL L/2


= 1.94 kN
LL Shear at Support, VLL = W,LL L/2
= 0.44 kN