Connectors: UIC Series Inter-Car Jumpers To UIC 558 VE Catalogue F120.en
Connectors: UIC Series Inter-Car Jumpers To UIC 558 VE Catalogue F120.en
UIC Series
Inter-car jumpers
to UIC 558 VE
Catalogue F120.en
More information
schaltbau.com
schaltbau.com Seite 2
Backshell
Insert
Subject to change
Seite 3 schaltbau.com
Layout
Contact cavities:
implemented
empty
Contact arrangement 8 13 8 13 20 21
9 18 9 14 19 8 9 10 22
Contact identification marked on insert 7 11 7 11 7 1 2 11
6 10 12 6 10 12
5 1 18 6 3 12
Pin insert: front view 3 16
5
3
1
17 17 5 4 13
Socket insert: rear view 4 2 4
15
2 16 15 14
Approvals
*1 Current rating of individual contacts with replacement insert: maximum temperature rise 70 K at 10 A, exceeding by far the 30 K at 1 A according to UIC 558 VE.
*2 Contact resistance with replacement insert: after climate test < 200 mΩ typ.
*3 Standard is nickel. Silver or gold plated contacts upon request (not available for BT, CA).
Subject to change
schaltbau.com Seite 4
Example: UIC SL 18P ER D2 Lxxxx Ag
Series
UIC Inter-car jumpers
to UIC 558 VE
Plug / receptacle / dummy / empty
SK Plug 13 pole, pre-assembled with connector cable and cable harness
SL Plug, pre-assembled with connector cable
VK Connector cable, double ended, pre-assembled
ST Plug
DK Socket insert 13 pole, pre-assembled with connector cable and harness
DL Socket insert, pre-assembled with connector cable
BT Replacement insert, requiring CA *
CA Crimp adapter, requiring BT *
KD Receptacle *
BD Dummy receptacle with insert, no contacts
LD Empty receptacle, no insert implemented
KK Cable gland Pg21 for through hole mounting
Insert: Number of / type of contacts / finish
13P Plug: 13 pole pin, nickel plated
18P Plug: 18 pole pin, nickel plated
22P Plug: 22 pole + PE pin, nickel plated
13S Receptacle: 13 pole socket, nickel plated
18S/P Replacement insert: 18 pole socket on both ends, nickel plated
18S Receptacle: 18 pole socket, nickel plated
22S Receptacle: 22 pole + PE socket, nickel plated
130-180-220 Dummy receptacle: with insert, no contacts implemented
00 Empty receptacle: no insert implemented
Colour of shell
E for plug: black
R for plug: red
C for receptacle: RAL 7035, light grey, acc. to standard
D for receptacle: RAL 3020, traffic red
F for receptacle: RAL 7012, basalt grey
G for receptacle: RAL 5022, night blue
T for receptacle: RAL 7022, umbra grey
0 for socket insert: black
Colour marking
R red: only for 18 pole jumpers, acc. to standard
B blue: only for 22 pole +PE jumpers
0 none
Cable gland
D1 only plug: for cable diameters 12.5 ... 15.5 mm
D2 only plugs: for cable diameters 16.5 ... 18.5 mm
Connector cable
Cable length (for assembled cable sets only with the length you require)
Lxxxx
Length in mm
Special designs
Ag Silver plated instead of nickel plated, on request (no option for BT and CA)
Au Gold plated instead of nickel plated, on request (no option for BT and CA)
S1 Switching contact, receptacle only
F4 M6 earthing bolt, only with receptacle, dummy and empty receptacle
ZW Empty receptacle with centring guide, only with replacement insert
* For ordering a pre-assembled receptacle with replacement insert and crimp adater, see page 5 under stock items and page 8 also.
Note:
This catalogue shows only stock items. For some variants minimum quantities apply.
Please ask for the conditions.
Special variant:
If you need a special variant of the connector, please do not hesitate to contact us. Maybe
the type of connector you are looking for is among our many special designs. If not, we can
also supply customized designs. In this case, however, minimum ordering quantities apply.
Subject to change
Seite 5 schaltbau.com
● UIC SL 18P ER Lxxxx Connector cable, single ended ● UIC VK 18P ER Lxxxx Connector cable, double ended
● Receptacle with insert and connector cable, ● Receptacle with replacement insert, adapter and connector cable,
including: including:
1 2 1 2a 2b
● UIC ST 18P ER D2 Plug ● UIC KD 18S CR Receptacle
UIC Series
UIC Series
ST Plug
KD Receptacle
18P 18 pole, pins, nickel plated
18S 18 pole, sockets, nickel plated
E Colour of backshell: black
C RAL 7035, light grey
R Colour marking of backshell: red
R Colour marking of shell: red
D2 Cable gland Ø 16.5 ... 18.5 mm
Subject to change
schaltbau.com Seite 6
● UIC SK 13P E0 Lxxxx 13 pole plug with single ended connector cable and cable harness
13x pin contacts Backshell
13 screen
3 yellow
7 yellow
11 yellow
white
white
10 white
red
100±5
4 black
8 black
red
5 red
9 red
1
2
12
11
115 ~40 121 (11 x 11)
54 Lxxxx 180 53
Single ended connector cable with 13 pole plug and cable harness, pre-assembled with the length you require
Cable length Lxxxx Tolerance
Layout Ordering code Colour # of contacts Length ≤ 2,000 mm ± 20 mm
> 2,000 mm, ≤ 4,000 mm ± 30 mm
black, Cable length Lxxxx > 4,000 mm, ≤ 10,000 mm ± 60 mm
UIC SK 13P E0 Lxxxx 13 pins > 10,000 mm ± 80 mm
no colour marking in mm
Note:
13 pole plug, with 18 wire connector cable (5 wires not used)
● UIC SL 18P ER Lxxxx 18 pole plug with single ended connector cable
18x pin contacts Colour marking Backshell
115 ~40
54 Lxxxx
Single ended connector cable with 18 pole plug, pre-assembled with the length you require
Layout Ordering code Colour # of contacts Length Cable length Lxxxx Tolerance
≤ 2,000 mm ± 20 mm
> 2,000 mm, ≤ 4,000 mm ± 30 mm
black, Cable length Lxxxx > 4,000 mm, ≤ 10,000 mm ± 60 mm
UIC SL 18P ER Lxxxx 18 pins
red colour marking in mm > 10,000 mm ± 80 mm
● UIC VK 13P E0 Lxxxx, UIC VK 18P ER Lxxxx 18 pole double ended connector cables with 2 plugs
18x pin contacts Colour marking Backshell
Double ended connector cables with plugs, pre-assembled with the length you require
Cable length Lxxxx Tolerance
Layout Ordering code Colour # of contacts Length ≤ 2,000 mm ± 20 mm
> 2,000 mm, ≤ 4,000 mm ± 30 mm
black, Cable length Lxxxx > 4,000 mm, ≤ 10,000 mm ± 60 mm
UIC VK 13P E0 Lxxxx 13 pins > 10,000 mm ± 80 mm
no colour marking in mm
Note:
13 pole plug, with 18 wire connector cable (5 wires not used)
● 13 pole receptacle with socket insert and single ended connector cable with cable harness, including:
yellow
yellow
yellow
white
white
white
100±5
black
black
black
red
red
red
13
12
11
10
9
8
7
6
5
4
3
2
1
65
125
45
11
121 (11 x 11)
83 53 180 Lxxxx
Empty receptacle, see Fig. Socket insert with single ended connector cable and cable harness,
pre-assembled with the length you require, see Fig.
Ordering code Colour Layout Ordering code # of contacts Length Cable length Lxxxx Tolerance
≤ 2,000 mm ± 20 mm
UIC LD 130 C0
RAL 7035, + UIC DK 13S 00 Lxxxx 13 sockets
Cable length Lxxxx
> 2,000 mm, ≤ 4,000 mm ± 30 mm
> 4,000 mm, ≤ 10,000 mm ± 60 mm
light grey in mm > 10,000 mm ± 80 mm
Note:
13 pole socket insert with 18 wire connector cable (5 wires not used)
● 18 pole receptacle with socket insert and single ended connector cable, including:
125
45
83 Lxxxx
Empty receptacle, see Fig. Socket insert with single ended connector cable and cable harness,
pre-assembled with the length you require, see Fig.
Ordering code Colour Layout Ordering code # of contacts Length Cable length Lxxxx Tolerance
≤ 2,000 mm ± 20 mm
RAL 7035, > 2,000 mm, ≤ 4,000 mm ± 30 mm
UIC LD 180 CR
light grey + UIC DL 18S 00 Lxxxx 18 sockets
Cable length Lxxxx > 4,000 mm, ≤ 10,000 mm ± 60 mm
> 10,000 mm ± 80 mm
Colour marking: in mm
red
Ø39.2
65
125
83 45
● 18 pole receptacle with replacement insert, crimp adapter and single ended connector cable, including:
125
45
Empty receptacle Replacement insert 18 pole Crimp adapter 18 pole with single ended connector cable,
Table Table pre-assembled with the length you require, see Table
Ordering code Colour Layout Ordering code Layout Ordering code # of contacts Length
UIC LD 180 CR ZW
RAL 7035, light grey + UIC BT 18S/P
+ UIC CA 18P 00 Lxxxx 18 pins
Cable length Lxxxx
Colour marking: red in mm
Pin contacts Colour marking Backshell Cable gland Ordering code # of contacts Colour Cable gland
cable diameter
D1: 12.5 ... 15.5 mm for cable Ø
D2: 16.5 ... 18.5 mm UIC ST 13P E0 D1 13 black
12.5 ... 15.5 mm
black for cable Ø
UIC ST 18P ER D2 18
Colour marking: red 16.5 ... 18.5 mm
black for cable Ø
UIC ST 22P EB 22
Colour marking: blue 16.5 ... 18.5 mm
approx. Note:
54 115 40
● All pin contacts included in delivery
● For other options, such as different shell colours, refer to Ordering code, p. 4, or contact us
65
Receptacle Empty receptacle
with socket insert no socket insert 52
and crimp contacts no crimp contacts
43
see table 1 see table 3
Dummy receptacle 28
with socket insert
no crimp contacts
see table 2 R115
65
65
125
45
45
30
M6 earthing bolt, 6.6
83 for special design 83
F4 only
UIC KD 13S C0 13 UIC BD 130 C0 13 UIC LD 130 C0 --- RAL 7035, light grey
● Pg21 antikink cable glands: Mounting wall Nut Strain relief bushing Tensioning screw
PA 6 GF30 PA 6 GF30 PA 6 GF30
Mounting hole Mounting wall black Spring disc Supporting ring black black
Pg 21
Ø30
D2
36 0 ... 8
Ordering code Description
24 39.5+1
UIC KK D1 Cable diameter 12.5 ...15.5 mm
Delivery:
Kit including the parts mentioned above. UIC KK D2 Cable diameter 16.5 ...18.5 mm
All parts individually packed.
Cable 18pole cable connectors, single and double ended UIC series
Both single and double ended 18 pole cable connectors comply with Wire train bus (WTB) Screen
the EN 45545 standard and are delivered by the metre. 17 white wire train bus (WTB)*
18 black Cu braid
17
Ordering code: UIC558 adapter cable 18-pin Group 4 Group 1
14 18 1
14 1
● Train bus: 1 x 2 x 18 AWG, wires 17, 18 15 white with white with 2
16 numbering 20 16 4 3 numbering 3
15 2
● Signal cable: 4 x 4 x 17 AWG, wires 1 ... 12, 14 ... 16 20* 4
25
* *
45
Ø 6.5
* Diameter for all fixing and securing elements, such as screw
heads: 12.5 mm max.
Hole for M6 earthing bolt,
for special design F4 only Dimensions in mm / Subject to change
Seite 11 schaltbau.com
The UIC Series inter-car jumpers dealt with in this catalogue are in- maintenance of or tampering with electric equipment can cause serious
tended for use with low-voltage systems and special installations. They or fatal injury to the user or others, and the appliance or other property
are designed and tested in compliance with the generally recognised can be damaged.
state of the art. However, the improper use, operation, handling,
Due to our continuous improvement programme, the Electrical hazards: Any exposure to the connector‘s live
design of our products can be modified at any time. parts. Risk of electrical shock!
So some features may differ from the descriptions, specifi Observe all applicable national provisions, all safety,
cations and drawings in the catalogue. accident prevention and environmental regulations as
You can download the latest update of the catalogue at well as the recognized technical rules for safe and proper
schaltbau.info/download1en. The updated catalogue working.
renders the previous issue invalid.
● Only authorized and trained personnel are allowed to plan and carry ● Make sure that there is no undue strain, pressure, flexing and torsion
out all mechanical and electrical installations, transport, commission- on the cable connection.
ing, as well as maintenance and repair work. ● For optimum protection of the cable connection make sure the
● This applies to the observation of the general installation and safety connector is supplied with a strain relief.
regulations for low-voltage systems as well as the proper use of tools ● According to IEC 61984 connectors used as intended must not be
approved for this purpose. Electric equipment requires protection engaged or disengaged when live or under load.
from moisture and dust during installation, operation and storage.
● Crimp connections have to be manufactured according to
● Electrical hazards: Any exposure to the connector‘s live parts. Risk of IEC 60352-2 – Solderless Connections.
electrical shock!
● When disengaging a connector, pull the plug and never the cable.
● Work on electric equipment may only be performed by a qualified
● A connector that does not engage easily requires special attention:
electrician or trained personnel working under the direction and
Check for the correct orientation, pollution or if contacts got bent.
supervision of a qualified electrician according to the applicable rules
Remedy the cause without delay. Never use force! The connector
of electrical engineering.
should always engage easily.
● Observe all applicable national provisions, all safety, accident preven-
● In order to meet the requirements of the protection class and to
tion and environmental regulations as well as the recognized techni-
protect the connectors against the entry of dirt or moisture, make
cal rules for safe and proper working.
sure that, when not mated,
● Carry out regular inspections of all protection and safety devices to
● the plug is always inserted into a dummy receptacle
see if they work properly.
● the hinged lid of receptacles is closed, according to its
● Work on electric equipment may only be performed by a qualified intended use
electrician or trained personnel working under the direction and
● Use the connector only according to its intended use. Replace or
supervision of a qualified electrician according to the applicable
repair damaged parts exclusively with original parts. Any other usage
rules of electrical engineering.
of or tampering with the connector is considered contrary to its
● The connectors supply power and signals. They are intended for intended use. No liability is assumed for damages and accidents
plug-in and detachable connections of components, devices and caused due to non-compliance with the instructions or improper
systems only. use of the connector.
● In order to comply with IEC 61984 make sure that always the live side ● The connectors are constructed for specific ambient conditions.
of the connector – no matter whether plug or receptacle – is fitted Operate the connectors only under the ambient conditions, like
with socket contacts. Crimp connections have to be manufactured temperature ranges and IP protection classes as defined in our
according to IEC 60352-2 – Solderless Connections. catalogue on page 3 “Specifications“.
Visual inspections
Be sure to make visual inspections regularly. Improper handling of the
connector, e.g. when hitting the floor with some impact, can result in
breakage, visible cracks and deformation.
Subject to change
Schaltbau GmbH with compliments:
Schaltbau GmbH
Hollerithstrasse 5
81829 Munich
Germany
RoHS
Phone +49 89 9 30 05-0 2011/65/EC
Fax +49 89 9 30 05-350
Internet www.schaltbau.com
Schaltbau GmbH The production facilities Certified to Certified to
e-Mail [email protected] manufactures in of Schaltbau GmbH have DIN EN ISO 14001 DIN EN ISO 9001
compliance been IRIS certified since since 2002. For the most since 1994. For the most
with RoHS. 2008. recent certificate visit recent certificate visit
our website. our website.