ESC Series Data Sheet
ESC Series Data Sheet
Applications
Railway Industry Automation
Semiconduc Network
tor Military
/ Telecom
Boat Aviation Medical
Years Warranty
Automobile Charger
Features
2:1 / 4:1 +70˚C EMC FILTER 2250 VDC MLCC ON / OFF 91 %
2” x 1.2” Wide input without
Built‐in Insulation
No life‐span
REMOTE
High
range derating constrained efficiency
MTBF METAL
≥1.9M hours
CASE UVLO OCP OVP OTP
@50˚C GB
Trim
Enable
ESC Dual Series Block Diagram
Electrical Specifications
(Typical @ Ta=+25°C under nominal line voltage conditions unless noted.)
Input Specifications
Parameter Notes and Conditions Min. Typ. Max. Unit
ESC012 models (100ms max) 50
ESC018 models (100ms max) 50
ESC024 models (100ms max) 50
Transient Input Voltage Ranges VDC
ESC036 models (100ms max) 80
ESC048 models (100ms max) 80
ESC110 models (100ms max) 180
ESC012 models 9 12 18
ESC018 models 9 18 36
ESC024 models 18 24 36
Operating Input Voltage Ranges VDC
ESC036 models 18 36 75
ESC048 models 36 48 75
ESC110 models 40 110 160
ESC012 models 8.5 9
ESC018 models 8.5 9
Under‐Voltage Lockout ESC024 models 17.5 18
VDC
Start up Voltage ESC036 models 17.5 18
ESC048 models 35 36
ESC110 models 38 40
ESC012 models 7 8
ESC018 models 7 8
Under‐Voltage Lockout ESC024 models 16 17
VDC
Shutdown Voltage ESC036 models 16 17
ESC048 models 32 34
ESC110 models 35 37
Output Specifications
Parameter Notes and Conditions Min. Typ. Max. Unit
Output Voltage Accuracy VNOM 50% Load ±1.5 %
Line Regulation Low Line to High Line ±0.3 %
Load Regulation 10% to 100% Load ±0.5 %
Single output 0 %
Minimum Load
Dual output 10 %
Bandwidth 20MHz
3.3V & 5V 75/100 m Vp‐p
and with 1uF MLCC
Output Ripple & Noise Voltage
Output Capacitor each
All others 1 1.5 %Vpk‐pk
output
Temperature Drift ±0.04 % /˚C
Transient Recovery Time 25% load step change 800 µSec.
Transient Peak Deviation ΔIo/Δt=2.5A/us ±2 %Vo
Start‐Up Time When use Enable Function 20 mSec.
Trimming Output Voltage VNOM 10% Load ±10 %
Over Voltage Protection VNOM 10% Load 120 %
Output Power Protection VNOM (Current limit / Hiccup Mode) 120 %
Standards Compliance
Parameter Standard Test Conditions Performance Criteria
Environmental Compliance Reach; RoHS PASS
EMI EN55022 Class B
±4 kV Air Discharge
ESD EN61000‐4‐2 Crit. A
±4 kV Contact Discharge
Radiated Immunity EN61000‐4‐3 Level 2, 3 V/m Crit. A
Fast Transient EN61000‐4‐4 ±2 kV Applied Crit. A
Surge EN61000‐4‐5 ±2 kV Applied Crit. A
Conducted Immunity EN61000‐4‐6 Level 2, 3 V rms Crit. A
It is recommended to protect the input by fuses or other protection devices.
The standard modules meet EN55032 Class A and Class B standard with external components.
The information and specifications contained in this data sheet are believed to be correct at time of publication. All
specifications are subject to change without notice. No rights under any patent accompany the sale of any such
products or information contained herein.
Conducted EMI
Input terminal value (typ.) ESC110050-S-1-P50 @Vin = 110VDC, Iout = 10A
The fundamental switching frequency of the module is 260 kHz.
1.2
6
1 0.4
0.6 [10.16] 0.4
[15.24] 2 [10.16] Side View
0.4
Bottom View 5
[10.16] 0.4 0.04 [1.02]
[10.16] 0.2
3
4 1.8 [45.72]
(Metal Case –Flat)
Shape – P (Groove Cover/Heat Sink)
1.2
6
1 0.4
0.6 [10.16] 0.5
[15.24] 2 [12.70] Side View
0.4
Bottom View 5
[10.16] 0.4
0.04 [1.02]
3 [10.16]
4 0.2
1.8 [45.72]
(Metal case shell with Heat‐Sink)
Shape – B (BasePlate)
M3 Screw*4 1.33[38.78]
1.6
1.4
1 6
0.2 0.4
[5.08] [10.16] 0.45
2 Side View
0.4
Bottom View 5 [11.40]
[10.16] 0.4
[10.16] 0.04 [1.02]
3 4 0.18
1.8[45.72]
2.0 [50.80]
(Metal case shell with Heat‐Sink)
Pin Assignments:
Pin# Single Dual Note:
Pin Pitch tolerance: ±0.01 [0.25]
1 +Vin +Vin Pin Dimensions: .XX±0.02 [ .X±0.5mm]
2 ‐Vin ‐Vin Pin Material: Copper Alloy
3 Enable Enable Pin Plating: Gold
Dimensions in inches [mm]
4 Trim ‐Vout
Tolerances: .XX±0.02 [ .X±0.5mm]
5 ‐Vout Comm .XXX±0.001 [ .X±0.025mm]
6 +Vout +Vout
90 90
80
80
70
70
Efficiency(%)
60
Efficiency(%)
50 60
40 50
30
40
20
30
10
0 20
10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 % 100 %
69.76 81.24 82.46 84.70 86.50 87.63 87.90 87.73 87.66 87.56 10
40Vin
110Vin 64.66 78.56 83.88 86.50 87.88 88.68 89.16 89.46 89.63 89.59
0
160Vin 55.14 69.92 76.53 80.20 82.39 83.87 84.90 85.64 86.02 86.31 40 48 64 75 96 110 120 130 140 160
Efficiency VS.Output Load Efficiency VS. Input Voltage(V)
Figure 1 : Efficiency at Minimum, Nominal Figure 2 : Efficiency VS. Input Voltages
and Maximum Input voltages VS. Output load. at 100% rated power
120 120
100 100
Case Temperature(°C)
Output Power (%)
80 80
60 60
40 40
20 20 20LFM(horizontal)
20LFM(horizontal)
100LFM
100LFM 200LFM
200LFM
0 0
-40 -20 0 20 40 60 80 100 120 0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature (°C) Output Load(%)
Figure 3 : Ambient Temperature VS. Output Power
Figure 4 : Case Temperature VS. Output rated Power
Derating Curves
Figure 5 : CH1 = Vout, CH3 = Nominal Input Figure 6 : CH1 = Vout, CH3 = Enable Pin
Typical Start‐up waveform at Full load. Typical Start‐up waveform. Input voltage pre‐applied
Figure 7 : Transient Response at Output step load Figure 8 : Output Voltage Ripple & Noise at full load.
( Vin: Typical ,50~75% of output current; ΔIo/Δt =1A/μS ) ( Vin: Typical, With Output Capacitor to add 1uF MLCC )
Note:
※ Trim adjustments higher than the specified range can have an adverse effect on the converter’s performance
and are not recommended.
※ If the trim function is not used, leave the trim pin open.
Figure 1. Trim Connections To increase Output Figure 2. Trim Connections To Decrease Output
Voltages Using Fixed Resistors Voltages Using Fixed Resistors
Trim up resistor value(KΩ) Trim down resistor value(KΩ)
Vout 1% 2% 3% 4% 5% 6% 7% 8% 9% 10% Vout ‐1% ‐2% ‐3% ‐4% ‐5% ‐6% ‐7% ‐8% ‐9% ‐10%
3.3 75 34 20.6 13.7 9.6 6.9 4.9 3.5 2.3 1.4 3.3 83 37 21.9 14.3 9.7 6.7 4.5 2.9 1.6 0.6
5 112.2 51.1 30.7 20.5 14.4 10.4 7.5 5.3 3.6 2.2 5 139.8 63.5 38.1 25.4 17.8 12.7 9.0 6.3 4.2 2.5
12 267.8 121.9 73.3 49.0 .34.4 24.6 17.7 12.5 8.4 5.2 12 342.5 155.9 93.7 62.6 44.0 31.5 22.7 16.0 10.8 6.7
15 332.9 151.5 91 60.7 42.6 30.5 21.8 15.4 10.3 6.3 15 454.5 205 125.8 84.7 60.1 43.6 31.9 23.1 16.2 10.7
24 542 247 149 100 70.7 51.1 37.1 26.6 18.4 11.9
24 592 266 158 104 70.9 49.2 33.7 22.1 13.0 5.8
Enable Control Function Output Ripple Noise
The primary‐side, Enable Control function can be specified to The two copper strips simulate real‐world PCB impedances between
operate with either positive or negative polarity. Positive‐polarity the converter and its load. Scope measurements should be made
devices are enabled when the enable pin is left open or is pulled using BNC connectors or The probe ground should be less than 1/2
high . See “Enable Function Input. inch and soldered directly to the fixture.
Positive‐polarity devices are disabled when the enable pin is pulled All external capacitors should have appropriate voltage ratings and
low (under +1.0V with respect to –input). Negative‐polarity devices be located as close to the converter as possible.
are off when the enable pin is high/open and on when the enable Temperature variations for all relevant parameters should be taken
pin is pulled low. See Figure 3. into consideration. The most effective combination of external I/O
capacitors will be a function of line voltage and source impedance,
as well as particular load and layout conditions. See Figure 4.
+Vin +Vout
+Vin
+
ENABLE Vin Load
C_in MLCC To Scope
-Vin -Vin -Vout
50mm
Figure 3. Driving the Enable Control pin
Figure 4. Measuring Output Ripple/Noise(20MHz bandwidth)