E01-CA272 - Komatsu Error Code

This document provides troubleshooting information for a failure code related to an open error in the PCV1 circuit of a supply pump. It lists the possible causes as a defective supply pump, disconnection in the wiring harness, or a ground fault in the wiring harness. For each possible cause, it gives the standard value measurements that should be present in the circuit when operating normally to aid in troubleshooting. A circuit diagram related to the supply pump PCV1 is also provided.

Uploaded by

Hari Hara Suthan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
6K views1 page

E01-CA272 - Komatsu Error Code

This document provides troubleshooting information for a failure code related to an open error in the PCV1 circuit of a supply pump. It lists the possible causes as a defective supply pump, disconnection in the wiring harness, or a ground fault in the wiring harness. For each possible cause, it gives the standard value measurements that should be present in the circuit when operating normally to aid in troubleshooting. A circuit diagram related to the supply pump PCV1 is also provided.

Uploaded by

Hari Hara Suthan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SEN00790-02 40 Troubleshooting

Failure code [CA272] IMV/PCV1 Open Error


Action code Failure code IMV/PCV1 Open Error
Trouble
E11 CA272 (Engine controller system)
Contents of
• Open error was detected in PCV1 circuit of supply pump.
trouble
Action of
• None in particular.
controller
Problem that
appears on
machine
Related
information

Cause Standard value in normal state/Remarks on troubleshooting


aPrepare with starting switch OFF, then carry out troubleshooting with-
out turning starting switch ON.
Defective supply pump PCV1 (male) Resistance
1 PCV1
(Internal disconnection) Between (1) – (2) 2.3 – 5.3 z
Between (1), (2) –
Min. 1 Mz
chassis ground
aPrepare with starting switch OFF, then carry out troubleshooting with-
Disconnection in wiring out turning starting switch ON.
harness
Wiring harness between ENG (female) (4) – Resis-
2 (Disconnection in wiring or Max. 1 z
PCV1 (female) (1) tance
defective contact in con-
nector) Wiring harness between ENG (female) (5) – Resis-
Possible causes Max. 1 z
PCV1 (female) (2) tance
and standard
value in normal aPrepare with starting switch OFF, then carry out troubleshooting with-
state out turning starting switch ON.
Ground fault in wiring har- Between wiring harness of ENG (female) (4) –
Resis-
ness PCV1 (female) (1) and chassis ground and Max. 1 Mz
3 tance
(Short circuit with GND cir- chassis ground
cuit) Between wiring harness of ENG (female) (5) –
Resis-
PCV1 (female) (2) and chassis ground and Max. 1 Mz
tance
chassis ground
aPrepare with starting switch OFF, then carry out troubleshooting with-
out turning starting switch ON.
ENG (female) Resistance
4 Defective engine controller
Between (4) – (5) 2.3 – 5.3 z
Between (4), (5) –
Min. 1 Mz
chassis ground

Circuit diagram related to supply pump PCV1