Expt No: Date:: Load Test On Pelton Wheel
Expt No: Date:: Load Test On Pelton Wheel
Expt No: Date:: Load Test On Pelton Wheel
Expt No:
Date:
LOAD TEST ON PELTON WHEEL
AIM
To find the operating characteristic curves of Pelton Wheel at constant speed
and constant head and plot the following graphs
1. Efficiency Vs Output
2. Discharge Vs Output
3. Input Vs Output
APPARATUS
Pelton wheel fitted with loading arrangements, a pumping unit to supply water
at the required head, discharge measuring arrangements, tachometer, and gauges
PRINCIPLE
The turbine is run at constant speed and head specified by manufacturer and
efficiency of the turbine is determined by measuring the output torque of the machine
from zero to the rated maximum. The power output can be determined by measuring
the torque output of the turbine using rope brake arrangement.
Calculate the maximum value of (W-S) correspond to rated power. This can
be divided in to 6 equal parts approximately, and the machine can be loaded each time
with the corresponding load.
Maximum load calculation
Rated power in KW = 2πN(W-S)R
60 x 1000
N - Speed in rpm
W - Load on the pan in N
S - Spring balance reading in N
R - Effective Brake drum radius in Meter
PROCEDURE
1. Keep the nozzle at about 3/8th open position
2. Prime the pump if necessary
3. Keep the turbine in unloaded position. (No load on spring)
4. Close the delivery gate valve completely and start the pump
5. Open the delivery gate valve until the venturimeter pressure gauges indicate a
differential pressure of about 0.6Kg/sq.cm-this correspond to design flow rate
6. Note the turbine inlet pressure and keep at a constant head of 4.6Kg/sq.cm of water
in the pressure gauge fixed in the nozzle bend.
7. Keep the speed constant at the rated value
8. Note the venturimeter pressure gauge readings.
9. Load the turbine by adding weights to the hanger.
10. Repeat the experiment for different loads, keeping the speed constant by adjusting
the delivery gate valve.
11. Release the load simultaneously closing the delivery valve and then switch off the
Pump.
x 10 m of
+T0 -+S) x
.0055 x h0.5
h=(P1-P2)
T=(T1-T2
of water
9.81 N
water
CALCULATIONS
1. TO DETERMINE DISCHARGE
Pressure difference, h = (P1-P2) x 10 m of water
where
P1, Venturimeter line pressure gauge readings in. kg/sq.cm
P2, Venturimeter throat pressure gauge reading in kg/sq.cm
= ………………..
Graphs
Plot
1. Efficiency Vs Output
2. Discharge Vs Output
3. Input Vs Output
Q
η
I/P
Q η I/P
Output
Warning
1. Do not start the motor without priming the pump.
2. Do not start the motor without closing the delivery gate valve completely.
RESULT
INFERENCE